共查询到20条相似文献,搜索用时 0 毫秒
1.
The system based on coupling a headspace sampler to a mass spectrometer (HS-MS), which is considered one kind of electronic nose, is an emergent technique for ensuring and controlling quality in industry. It involves injecting the headspace of the sample into the ionization chamber of the mass spectrometer where the analytes are fragmented. The result is a complex mass spectrum for each sample analyzed. When several samples are analyzed the data matrix generated is processed with chemometric techniques to compare and classify the substances from their volatile composition, in other words, to compare and classify their flavor. So far, information from electronic nose applications has mainly been qualitative. In this paper we present a quantitative study that uses a multivariate calibration. We analyzed several white wines using HS-MS to determine 2,4,6-tricholoranisole (TCA). This is an off-flavor that is a serious problem for the wine industry. The method is simple because it does not require sample preparation, only addition of sodium chloride being necessary for sample conditioning. Also, it provides a fast screening (10 min/sample) of the quantity of TCA in wines at ultratrace (sub microg L(-1)) levels. 相似文献
2.
Multiple headspace solid-phase microextraction (MHS-SPME) with gas chromatography–mass spectrometry is proposed for quantification of nine volatile oak compounds in aged wines. These compounds are formed and extracted by wine when it is matured in oak barrels and are responsible for particular organoleptic properties and the high quality of these wines. Some important variables of the extraction process, for example volume of sample and extraction time, were studied. Extraction of 50 μL wine was performed with a divinylbenzene–Carboxen–polydimethylsiloxane fibre at 55 °C for 60 min. For calibration the same conditions were used, except that the wine was substituted by 50 μL of a standard solution in synthetic wine. The linearity, detection limits, and repeatability of the method were determined by use of standard solutions in synthetic wine. Detection limits were between 0.01 and 10 μg L−1 (for eugenol and furfural, respectively) and repeatability, expressed as relative standard deviation, was from 2 to 6%. The method was used to analyse six red wines and the concentrations obtained were statistically compared with those obtained by the standard addition method for the same wines. 相似文献
3.
A novel method based on the coupling of membrane-supported headspace single-drop microextraction with gas chromatography?mass spectrometry (GC–MS) is developed for the determination of chlorobenzenes in water samples. For the determination of five chlorobenzenes, a 15 μL toluene microdrop was placed inside the plastic membrane and exposed for 10 min for headspace extraction while stirring at 1000 rpm. The microdrop was then picked up by a microsyringe and directly injected into the injector block of the GC–MS instrument. Under the optimized operation conditions, the calculated calibration curves gave a high level of linearity for all targets with correlation coefficients range from 0.9945 to 0.9987. The limits of detection range from 0.01 to 0.05 μg/L and the RSDs for most of chlorobenzenes were below 7%. The method is simple, sensitive, and stable for single drop microextraction. Its applicability is demonstrated by the determination of chlorobenzenes in tap water samples. 相似文献
4.
Contamination by Brettanomyces is a frequent problem in many wineries that has a dramatic effect on wine aroma and hence its quality. The yeast Brettanomyces/Dekkera is involved in the formation of three important volatile ethylphenols—4-ethylphenol, 4-ethylguaiacol and 4-ethylcatechol—that
transmit an unpleasant aroma to wine that has often been described as ‘medicinal’, ‘stable’ or ‘leather’. This study proposes
an in situ derivatisation and headspace solid-phase microextraction– gas chromatography coupled to mass spectrometry method
to determine the three ethylphenols in red Brettanomyces-tainted wines. The most important variables involved in the derivatisation (acetic anhydride and base concentration) and
the extraction (extraction temperature and salt addition) processes were optimised by experimental design. The optimal conditions
using 4 mL of wine in 20-mL sealed vials were 35 μL of acetic anhydride per millilitre of wine, 1 mL of 5.5% potassium carbonate
solution and 0.9 g of sodium chloride and the extraction was performed with a divinylbenzene–carboxen–poly(dimethylsiloxane)
fibre at 70 °C for 70 min. Then, the performance characteristics were established using wine samples spiked with the ethylphenols.
For all compounds, the detection limits were below the odour threshold reported in the literature and they were between 2
and 17 μg L−1 for 4-ethylguaiacol and 4-ethylphenol, respectively. Intermediate precision (as relative standard deviation) was acceptable,
with values ranging from 0.3 to 12.1%. Finally, the method was applied in the analysis of aged Brettanomyces-tainted wines. 相似文献
5.
6.
Determination of cannabinoids in hemp food products by use of headspace solid-phase microextraction and gas chromatography–mass spectrometry 总被引:4,自引:0,他引:4
Lachenmeier DW Kroener L Musshoff F Madea B 《Analytical and bioanalytical chemistry》2004,378(1):183-189
A fully automated procedure using alkaline hydrolysis and headspace solid-phase microextraction (HS-SPME), followed by on-fiber derivatization and gas chromatographic–mass spectrometric (GC–MS) detection has been developed for determination of cannabinoids in hemp food samples. After addition of a deuterated internal standard, the sample was hydrolyzed with sodium hydroxide and submitted to direct HS-SPME. After absorption of analytes for on-fiber derivatization, the fiber was placed directly into the headspace of a second vial containing N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA), before GC–MS analysis. Linearity was good for
9-tetrahydrocannabinol (THC), cannabidiol, and cannabinol; regression coefficients were greater than 0.99. Depending on the characteristics of the matrix the detection limits obtained ranged between 0.01 and 0.17 mg kg–1 and the precision between 0.4 and 11.8%. In comparison with conventional liquid–liquid extraction this automated HS-SPME–GC–MS procedure is substantially faster. It is easy to perform, solvent-free, and sample quantities are minimal, yet it maintains the same sensitivity and reproducibility. The applicability was demonstrated by analysis of 30 hemp food samples. Cannabinoids were detected in all of the samples and it was possible to differentiate between drug-type and fiber-type Cannabis sativa L. In comparison with other studies relatively low THC concentrations between 0.01 and 15.53 mg kg–1 were determined. 相似文献
7.
Ina Kristiana Anna Heitz Cynthia Joll Arumugam Sathasivan 《Journal of chromatography. A》2010,1217(38):5995-6001
Sulfide and polysulfides are strong nucleophiles and reducing agents that participate in many environmentally significant processes such as the formation of sulfide minerals and volatile organic sulfur compounds. Their presence in drinking water distribution systems are of particular concern and need to be assessed, since these species consume disinfectants and dissolved oxygen, react with metal ions to produce insoluble metal sulfides, and cause taste and odour problems. The analysis of sulfide and polysulfides in drinking water distribution systems is challenging due to their low concentrations, thermal instability and their susceptibility to undergo oxidation and disproportionation reactions. This paper reports on the development and optimisation of a rapid, simple, and sensitive method for the determination of sulfide and polysulfides in drinking water distribution systems. The method uses methyl iodide to derivatise sulfide and polysulfides into their corresponding dimethyl(poly)sulfides, which are then extracted using solid-phase microextraction in the headspace mode and analysed by gas chromatography–mass spectrometry. Good sensitivity was achieved for the analysis of dimethyl(poly)sulfides, with detection limits ranging from 50 to 240 ng L−1. The method also demonstrated good precision (repeatability: 3–7%) and good linearity over two orders of magnitude. Matrix effects from raw drinking water containing organic carbon (3.8 mg L−1) and from sediment material from a drinking water distribution system were shown to have no interferences in the analysis of dimethyl(poly)sulfides. The method provides a rapid, robust, and reliable mean to analyse trace levels of sulfides and polysulfides in aqueous systems. The new method described here is more accessible and user-friendly than methods based on closed-loop stripping analysis, which have been traditionally used for the analysis of these compounds. The optimised method was used to analyse samples collected from various locations in a drinking water distribution system. Some of the samples were shown to contain inorganic polysulfides, and their presence was associated with high sediment density in the system and the absence of disinfectant residual in the bulk water. 相似文献
8.
Tse-Tsung Ho Chung-Yu Chen Zu-Guang Li Thomas Ching-Cherng Yang Maw-Rong Lee 《Analytica chimica acta》2012
A new microextraction technique based on ionic liquid solid-phase microextraction (IL-SPME) was developed for determination of trace chlorophenols (CPs) in landfill leachate. The synthesized ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]), was coated onto the spent fiber of SPME for extraction of trace CPs. After extraction, the absorbed analytes were desorbed and quantified using gas chromatography–mass spectrometry (GC/MS). The term of the proposed method is as ionic liquid-coated of solid-phase microextraction combined with gas chromatography–mass spectrometry (IL-SPME-GC/MS). No carryover effect was found, and every laboratory-made ionic liquids-coated-fiber could be used for extraction at least eighty times without degradation of efficiency. The chlorophenols studied were 2,4-dichlorophenol (2,4-DP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP), and pentachlorophenol (PCP). The best results of chlorophenols analysis were obtained with landfill leachate at pH 2, headspace extraction for 4 min, and thermal desorption with the gas chromatograph injector at 240 °C for 4 min. Linearity was observed from 0.1 to 1000 μg L−1 with relative standard deviations (RSD) less than 7% and recoveries were over 87%. The limit of detection (LOD) for pentachlorophenol was 0.008 μg L−1. The proposed method was tested by analyzing landfill leachate from a sewage farm. The concentrations of chlorophenols were detected to range from 1.1 to 1.4 μg L−1. The results demonstrate that the IL-SPME-GC/MS method is highly effective in analyzing trace chlorophenols in landfill leachate. 相似文献
9.
Perdivara I Deterding L Moise A Tomer KB Przybylski M 《Analytical and bioanalytical chemistry》2008,391(1):325-336
Using the bottom-up approach and liquid chromatography (LC) in combination with mass spectrometry, the primary structure and
sequence microheterogeneity of a plaque-specific anti-β-amyloid (1–17) monoclonal antibody (clone 6E10) was characterized.
This study describes the extent of structural information directly attainable by a high-performance LC–tandem mass spectrometric
method in combination with both protein database searching and de novo sequence determination. Using trypsin and chymotrypsin
for enzymatic digestion, 95% sequence coverage of the light chain and 82% sequence coverage of the heavy chain of the 6E10
antibody were obtained. The primary structure determination of a large number of peptides from the antibody variable regions
was obtained through de novo interpretation of the data. In addition, N-terminal truncations of the heavy chain were identified
as well as low levels of pyroglutamic acid formation. Surprisingly, pronounced sequence microheterogeneities were determined
for the CDR 2 region of the light chain, indicating that changes at the protein level derived from somatic hypermutation of
the Ig VL genes in mature B-cells might contribute to unexpected structural diversity. Furthermore, the major glycoforms at the conserved
heavy chain N-glycosylation site, Asn-292, were determined to be core-fucosylated, biantennary, complex-type structures containing
zero to two galactose residues.
Figure Primary structure and sequence microheterogeneities of a β-amyloid plaque-specific monoclonal antibody were identified by
high-performance LC-tandem-mass spectrometry. Sequence heterogeneities of the light chain CDR2 reveal unexpected diversity
from VL-gene hypermutations.
Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users. 相似文献
10.
Li Zhou Minjie Zhao Ali Khalil Christophe Marcic Françoise Bindler Eric Marchioni 《Analytical and bioanalytical chemistry》2013,405(28):9125-9137
Headspace solid-phase microextraction (HS-SPME) followed by gas chromatography–mass spectrometry analysis (GC-MS) was used to investigate the volatile compounds from oxidised phosphatidylcholine molecular species. 1-stearoyl-2-oleoyl-sn-glycero-3-phosphocholine (SOPC) and 1-stearoyl-2-linoleoyl-sn-glycero-3-phosphocholine (SLPC) were chosen as models. The influence of several parameters on the efficiency of volatile oxidised compounds (VOCs) microextraction, such as type of fibre, extraction duration and temperature were studied. The best results were obtained with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre used at 50 °C during 25 min. The effect of oxidation temperature on the yield of VOCs from SOPC and SLPC was investigated. Oxidative kinetics of SOPC and SLPC were investigated by measuring both the production of VOCs and the degradation of starting materials. More than 30 VOCs were detected by means of the reference mass spectra of the National Institute of Standards and Technology mass spectral library, and most of them were further confirmed by comparing their mass spectra and retention time with those obtained from authentic reference compounds under the same analytical conditions. Moreover, the origins of VOCs from oxidised PLs were studied by comparing those obtained from their corresponding triacylglycerides under the same experimental conditions. The main VOCs identified from oxidised SOPC were (E)-2-decenal, nonanal and octanal and from oxidised SLPC were (E)-2-heptenal, (E)-2-octenal and (E, E)-2,4-decadienal. The proposed method was applied to a real food sample, soy lecithin. Figure
Production of volatiles from oxidised phospholipid 相似文献
11.
12.
Jung PG Kim B Park SR So HY Shi LH Kim Y 《Analytical and bioanalytical chemistry》2004,380(5-6):782-788
We propose isotope-dilution mass spectrometry as a candidate reference method for determination of serum cortisol. The method uses liquid chromatography–mass spectrometry (LC–MS), interfaced with electrospray ionization, and selective monitoring of the [M+H]+ ions of cortisol and isotopically labeled cortisol. The isotope-dilution–liquid chromatography–mass spectrometry (ID–LC–MS) method simplifies sample-preparation, because samples are processed by simple solvent extraction without further clean-up and derivatization. We studied the time required for complete equilibration of endogenous cortisol and labeled cortisol spiked into serum and found it to be less than 1 h. The repeatability and the reproducibility of the method were evaluated and found to be 0.55% of the measurement value. CRM 192 and 193 from the Bureau Communautaire de Reference were analyzed for verification of the method. The results obtained from the ID–LC–MS method agreed with the certified values. The relative uncertainty of measurement results for samples in the range of a few tens of micrograms per kilogram to several hundred micrograms per kilogram was evaluated and found to be 0.56%. Immunoassay carried out by three independent clinical laboratories produced results more than 15% higher than this ID–LC–MS method, suggesting the presence of bias in the immunoassay methods. 相似文献
13.
14.
José Luis Pérez Pavón Miguel del Nogal Sánchez María Esther Fernández Laespada Bernardo Moreno Cordero 《Analytical and bioanalytical chemistry》2009,394(5):1463-1470
A sensitive method for the fast analysis of filbertone in spiked olive oil samples is presented. The applicability of a headspace
(HS) autosampler in combination with a gas chromatograph (GC) equipped with a programmable temperature vaporizer (PTV) and
a mass spectrometric (MS) detector is explored. A modular accelerated column heater (MACHTM) was used to control the temperature of the capillary gas chromatography column. This module can be heated and cooled very
rapidly, shortening total analysis cycle times to a considerable extent. The proposed method does not require any previous
analyte extraction, filtration and preconcentration step, as in most methods described to date. Sample preparation is reduced
to placing the olive oil sample in the vial. This reduces the analysis time and the experimental errors associated with this
step of the analytical process. By using headspace generation, the volatiles of the sample are analysed without interference
by the non-volatile matrix, and by using injection in solvent-vent mode at the PTV inlet, most of the compounds that are more
volatile than filbertone are purged and the matrix effect is minimised. Use of a liner packed with Tenax-TA? allowed the compound
of interest to be retained during the venting process. The limits of detection and quantification were as low as 0.27 and
0.83 μg/L, respectively, and precision (measured as the relative standard deviation) was 5.7%. The method was applied to the
determination of filbertone in spiked olive oil samples and the results revealed the good accuracy obtained with the method. 相似文献
15.
Jennilee M. A. Gavina Jessica Priem Carla M. Wood Chao Wu Xiao Yong-Lai Feng 《Analytical and bioanalytical chemistry》2013,405(8):2643-2651
Consumption and nutritional supplementation of soy and soy-based products have been linked to health benefits such as lower cholesterol and triglyceride levels, and decreased incidence of cardiovascular disease and diabetes. In this study, we have developed a sensitive, specific, and robust method using high-performance liquid chromatography–tandem mass spectrometry (HPLC-MS/MS) for determination of serum isoflavones. A new highly efficient pentafluorophenyl phase core–shell column was first used to separate all isoflavones within 3 min, a separation time which is comparable to ultra-pressure liquid chromatography (UPLC) and micro-HPLC. A two-enzyme hydrolysis system with sulfatase and β-glucuronidase has also been developed to improve the efficiency of deconjugation of conjugated isoflavones in serum. The corresponding conjugated isoflavones were used to evaluate recoveries. In addition to duplicates, the method of standard addition was also applied in sample analysis for quality control. The developed method was applied to the analysis of 32 serum samples and was shown to be specific, sensitive and reproducible. 相似文献
16.
Paglia G Hrafnsdóttir S Magnúsdóttir M Fleming RM Thorlacius S Palsson BØ Thiele I 《Analytical and bioanalytical chemistry》2012,402(3):1183-1198
Here we present an ultra-performance liquid chromatography–mass spectrometry (UPLC–MS) method for extracellular measurements
of known and unexpected metabolites in parallel. The method was developed by testing 86 metabolites, including amino acids,
organic acids, sugars, purines, pyrimidines, vitamins, and nucleosides, that can be resolved by combining chromatographic
and m/z dimensions. Subsequently, a targeted quantitative method was developed for 80 metabolites. The presented method combines
a UPLC approach using hydrophilic interaction liquid chromatography (HILIC) and MS detection achieved by a hybrid quadrupole–time
of flight (Q–ToF) mass spectrometer. The optimal setup was achieved by evaluating reproducibility and repeatability of the
analytical platforms using pooled quality control samples to minimize the drift in instrumental performance over time. Then,
the method was validated by analyzing extracellular metabolites from acute lymphoblastic leukemia cell lines (MOLT-4 and CCRF-CEM)
treated with direct (A-769662) and indirect (AICAR) AMP activated kinase (AMPK) activators, monitoring uptake and secretion
of the targeted compound over time. This analysis pointed towards a perturbed purine and pyrimidine catabolism upon AICAR
treatment. Our data suggest that the method presented can be used for qualitative and quantitative analysis of extracellular
metabolites and it is suitable for routine applications such as in vitro drug screening. 相似文献
17.
A novel geometry configuration based on sorbent-coated glass microfibers packed within a glass capillary is used to sample volatile organic compounds, dynamically, in the headspace of an open system or in a partially open system to achieve quantitative extraction of the available volatiles of explosives with negligible breakthrough. Air is sampled through the newly developed sorbent-packed 2 cm long, 2 mm diameter capillary microextraction of volatiles (CMV) and subsequently introduced into a commercially available thermal desorption probe fitted directly into a GC injection port. A sorbent coating surface area of ~5?×?10?2 m2 or 5,000 times greater than that of a single solid-phase microextraction (SPME) fiber allows for fast (30 s), flow-through sampling of relatively large volumes using sampling flow rates of ~1.5 L/min. A direct comparison of the new CMV extraction to a static (equilibrium) SPME extraction of the same headspace sample yields a 30 times improvement in sensitivity for the CMV when sampling nitroglycerine (NG), 2,4-dinitrotoluene (2,4-DNT), and diphenylamine (DPA) in a mixture containing a total mass of 500 ng of each analyte, when spiked into a liter-volume container. Calibration curves were established for all compounds studied, and the recovery was determined to be ~1 % or better after only 1 min of sampling time. Quantitative analysis is also possible using this extraction technique when the sampling temperature, flow rate, and time are kept constant between calibration curves and the sample. 相似文献
18.
A rapid, sensitive, and environmental-friendly multi-residue method has been developed for the simultaneous determination of seven neonicotinoid insecticides (dinotefuran, nitenpyram, thiamethoxam, imidacloprid, clothianidin, acetamiprid, and thiacloprid) residues in eel samples. Subcritical water extraction was investigated as a novel and alternative technology for the extraction of neonicotinoids from eel matrices and the results were compared with the conventional ultrasonic and shaking extraction. The target compounds were identified and quantitatively determined by ultra-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC–MS/MS) operated in multiple reaction monitoring mode. Under the current optimized chromatographic conditions, each LC run was completed in 5 min. Average recoveries of the seven analytes from fortified samples ranged between 84.6% and 102.0%, with relative standard deviations (RSD) lower than 10.8%. The limits of detection (LODs) and quantification (LOQs) for neonicotinoids were in the ranges of 0.12–0.36 μg kg−1 and 0.42–1.12 μg kg−1, respectively. The proposed method is fast, sensitive, easy to perform, water-based thus more environmentally acceptable, making it applicable for high-throughput monitoring of insecticides residues in aquatic products. 相似文献
19.
Jin F 《Analytical and bioanalytical chemistry》2011,400(9):2881-2887
A rapid, sensitive, and selective liquid chromatography–tandem mass spectrometry method for the detection of tandospirone
in human plasma is described. It was employed in a pharmacokinetic study. The analyte and internal standard diphenhydramine
were extracted from plasma using liquid–liquid extraction, then separated on a Zorbax XDB C18 column using a mobile phase of methanol–water–formic acid (80:20:0.5, v/v/v). The detection was performed with a tandem mass
spectrometer equipped with an electrospray ionization source. Linearity was established in the concentration range of 10.0-5,000 pg/ml.
The lower limit of quantification was 10.0 pg/ml. The intraday and interday relative standard deviation across three validation
runs over the entire concentration range was less than 13%. Accuracy determined at three concentrations (25.0, 200, and 4,000 pg/ml
for tandospirone) ranged from 94.4 to 102.1%. Each plasma sample was chromatographed within 3.4 min. The method proved to
be highly selective and suitable for bioequivalence evaluation of different formulations containing tandospirone and clinical
pharmacokinetic investigation of tandospirone. 相似文献
20.
Zhao F Ponnaiyan TK Graham CM Schall CA Varanasi S Anderson JL 《Analytical and bioanalytical chemistry》2008,392(7-8):1271-1275
The application of ionic liquids (ILs) as nonderivatizing solvents for the pretreatment and regeneration of cellulose is a growing area of research. Here we report the development of a rapid and simple method for the determination of residual ethanol content in two hydrophilic ILs, 1-butyl-3-methylimidazolium chloride and 1-ethyl-3-methylimidazolium acetate. The method utilizes headspace solid-phase microextraction coupled with gas chromatography at elevated extraction temperatures, resulting in rapid equilibration times. The effect of IL water content on the ethanol extraction efficiency is presented. Recovery experiments carried out in real samples gave recoveries ranging from 96.8 to 98.2%. 相似文献