首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objectives of this study, were the development and validation of an analytical method for the determination of 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA) and pentachloroanisole (PCA) in red wine by headspace solid-phase microextraction and GC-MS as well as the application of the optimized and validated method for the quatification of chloroanisoles in different red wines from Navarra. To carry out this study, the extraction variables have been optimized. The fiber and the experimental design selected permit the determination of low analyte concentrations (ng/L) with good accuracy (<5%). Moreover, an analytical method for the determination of TCA and TeCA in wine by GC-MS has been validated. The results obtained in the validation step, recovery values, detection and quantitative limits, and precision were acceptable for all the analytes in the ranges of concentration studied (<5% and <10% for TCA and TeCA, respectively). This method has been used as an analytical method for the quantification of TCA and TeCA in red wine samples that were selected for this study, yielding good results.  相似文献   

2.
An analytical procedure based on headspace solid-phase microextraction (SPME) followed by gas chromatography coupled to mass spectrometry in the electron impact mode has been developed for the determination of low-molecular-mass sulfides and disulfides in wastewater. Parameters affecting to the extraction of these volatile alkyl sulfides (VASs) with the SPME, such as the extraction temperature, sample volume, pH and the NaCl addition to the matrix, have been optimised using a polydimethylsiloxane-Carboxen fibre. The linear dynamic range was close to three orders of magnitude for all the studied compounds. Detection limits of 4 ng l(-1) for dimethyl sulfide, 0.7 ng l(-1) for ethylmethyl sulfide, 5 ng l(-1) for diethyl sulfide and 1 ng l(-1) for dimethyl disulfide were achieved, with a relative standard deviation between 4 and 6%. The developed analytical methodology was applied to determine those VASs in different wastewaters.  相似文献   

3.
A method for the determination of trace amounts of the herbicide oxadiazon was developed using headspace solid-phase microextraction (HS-SPME), gas chromatography-mass spectrometry (GC-MS) and selected ion monitoring. It was applied to determine oxadiazon in ground water, agricultural soil, must, wine and human urine samples. To determine oxadiazon in liquid samples, a response surface methodology generated with a Doehlert design was applied to optimize the HS-SPME conditions using a 100 microm polydimethylsiloxane fibre. For the analysis of soil samples, they were mixed with water and the SPME fibre suspended in the headspace above the slurry. Ground water, human urine and must show linear concentration range of application of 0.5-50 ng ml(-1)' with detection limits < or =0.02 ng ml(-1). HS-SPME-GC-MS analysis yielded good reproducibility (RSD values between 6.5 and 13.5%). The method validation was completed with spiked matrix samples. The developed analytical procedure is solvent free, cost effective and fast.  相似文献   

4.
A method is described for the determination of volatile compounds in Magnolia bark using microwave-assisted extraction coupled to headspace solid-phase microextraction (MAE-HS-SPME), followed by gas chromatography with mass spectrometry (GC-MS). Parameters affecting the extraction efficiency, such as sampling time and temperature, microwave irradiation power and desorption time, were investigated to achieve the optimal conditions. The result obtained was compared with that of steam distillation; only small differences existed between these two methods. Therefore, the proposed method seems to be a feasible and relatively simple, fast and solvent-free procedure for identification of essential oils in Magnolia bark.  相似文献   

5.
This paper describes the development of a headspace solid-phase microextraction gas chromatography-mass spectrometry (HS-SPME-GC-MS) method for determining phthalates in wine. The HS-SPME conditions were thoroughly studied: first, the performance of six fibres at three temperature values and two sample volumes was surveyed by means of a 6 x 3 x 2 multi-factor categorical experimental design. From this study, three fibres - carbowax-divinylbenzene (CW-DVB), polyacrylate (PA) and polydimethylsiloxane-divinylbenzene (PDMS-DVB) - were selected. Then, temperature, sample volume and sodium chloride concentration were optimised using a central composite design and the overall desirability function for each fibre. The optimal values were 70 degrees C, a NaCl concentration of 2.6, 3.6 and 5.5M for PA, CW-DVB and PDMS-DVB fibres, respectively, and sample volumes of 4.0, 3.5 and 3.0 mL. Next, the performance characteristics of the three fibres were obtained and compared. PDMS-DVB fibre showed the best repeatability values followed by CW-DVB. PA fibre was not suitable for diethylhexylphthalate extraction and showed poor repeatability for the heavier phthalates, and was therefore discarded. Finally, the performance of CW-DVB and PDMS-DVB fibres was checked for red, white and rosé wines.  相似文献   

6.
A method using headspace solid-phase microextraction (HS-SPME) then gas chromatography–mass spectrometry with selected ion monitoring (GC–MS, SIM) has been developed for determination of trace amounts of the fungicides pyrimethanil and kresoxim-methyl in soil and humic materials. Both fungicides were extracted on to a fused-silica fibre coated with 85 m polyacrylate (PA). Response-surface methodology was used to optimise the experimental conditions. For soil samples the linear dynamic range of application was 0.004–1.000 g g–1 for pyrimethanil and 0.013–1.000 g g–1 for kresoxim-methyl. The detection limits were 0.001 g g–1 and 0.004 g g–1 for pyrimethanil and kresoxim-methyl, respectively. HP-SPME–GC–MS analysis was highly reproducible—relative standard deviations (RSD) were between 6.7 and 12.2%. The method was validated by analysis of spiked matrix samples and used to investigate the presence of pyrimethanil and kresoxim-methyl above the detection limits in soil and humic materials.  相似文献   

7.
Wang G  Tang H  Chen D  Feng J  Li L 《色谱》2012,30(2):135-140
建立了香水中5种合成麝香的顶空固相微萃取-气相色谱-质谱联用分析方法。实验选用65 μm的聚二甲基硅氧烷-二乙烯基苯(PDMS-DVB)萃取纤维,在磁力搅拌600 r/min条件下,考察了萃取温度、平衡时间、萃取时间、解吸时间、进样口温度和盐效应6个方面对实验结果的影响。优化后的条件为: 10 mL顶空瓶中加入适量用水稀释过的样品,于60 ℃平衡3 min后,顶空萃取20 min,随即插入气相色谱进样口,于250 ℃解吸3 min进行定性、定量分析。5种合成麝香在0.05~1.00 μg/g范围内线性关系良好,检出限(LOD)为0.6~2.1 ng/g。空白样品在3个浓度加标水平下(0.05, 0.50, 1.00 μg/g)的回收率为82.0%~103.3%,相对标准偏差(RSD)为1.8%~9.4%。本方法简便、准确、快速、灵敏,适用于香水中合成麝香的分析检验工作。  相似文献   

8.
刘敬科  张爱霞  李少辉  赵巍  张玉宗  邢国胜 《色谱》2017,35(11):1184-1191
为全面了解小米黄酒风味成分的构成和气味特征,优化了85μm聚丙烯酸酯(PA)、100μm聚二甲基硅氧烷(PDMS)、75μm碳分子筛(CAR)/PDMS、50/30μm二乙烯基苯(DVB)/CAR/PDMS萃取头提取小米黄酒风味成分的条件,采用顶空固相微萃取(headspace solid phase microextraction,HS-SPME)-气相色谱-质谱法(GC-MS)对风味成分进行定性、定量分析,并计算气味活性值(odor active value,OAV),同时利用OAV分析风味成分的气味特征和气味强度。结果显示:不同萃取头的最优萃取条件为样品量8 mL、萃取时间40 min、萃取温度60℃、NaCl添加量1.5 g。小米黄酒风味成分由醇、酯、含苯化合物、烃、酸、醛、酮、烯、酚和杂环类化合物构成,醇为主要风味成分。通过OAV确定了苯乙醇、苯乙烯、2-甲基萘、1-甲基萘、苯甲醛、苯乙醛、2-甲氧基-苯酚为小米黄酒气味特征成分,苯基乙醇、苯乙醛对气味贡献最大。PA和PDMS萃取头分别对极性和非极性化合物具有较好的吸附效果,CAR/PDMS和DVB/CAR/PDMS萃取头对中等极性化合物具有较好的吸附效果。该研究全面了解了小米黄酒风味成分的构成,为其产品开发及品质控制提供理论了依据。  相似文献   

9.
顶空气相色谱-质谱法测定玩具中的10种挥发性有机物   总被引:1,自引:0,他引:1  
吕庆  张庆  康苏媛  白桦  王超 《色谱》2010,28(8):800-804
建立了检测玩具中10种挥发性有机物(VOC)残留量的顶空气相色谱-质谱(HS-GC-MS)方法。样品经140 ℃、45 min静态顶空后,通过DB-624色谱柱分离和质谱检测,外标法定量。该方法对于不同VOC的定量限(LOQ)均在0.66 mg/kg以下,线性范围为0.001~2.0 μg,平均回收率在79%~106%之间,相对标准偏差(RSD)在0.4%~5.6%之间。该方法具有准确灵敏、简单快速等特点,将其应用于实际玩具样品的检测取得了良好效果。  相似文献   

10.
11.
A method for determination of trace amounts of the fungicides pyrimethanil and kresoxim-methyl in green groceries, previous headspace solid-phase microextraction (HSSPME), was developed using gas chromatography-mass spectrometry and selected ion monitoring (GC-MS, SIM). Both fungicides were extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, extraction and desorption times as well as the extraction temperature were studied. The linear concentration range of application was 12.5-250 ng g(-1) for both compounds, with detection limits of 1.8-2.0 ng g(-1) for pyrimethanil and 2.8-3.1 ng g(-1) for kresoxim-methyl. SPME/GC-MS analysis yielded good reproducibility (RSD between 7.4 and 15.0%). It was applied to check the eventual existence of pyrimethanil and kresoxim-methyl above the detection limits on grapes, strawberries, tomatoes and ketchup samples. The method validation was completed with spiked matrix samples. It can be applied as a monitoring tool in grapes, strawberries, tomatoes and ketchup samples.  相似文献   

12.
This paper describes a rapid and solvent-free method, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for the extraction of six commonly used synthetic polycyclic musks: galaxolide (HHCB), tonalide (AHTN), celestolide (ADBI), traseolide (ATII), cashmeran (DPMI) and phantolide (AHMI) from water samples prior to their determination using gas chromatography-mass spectrometry (GC-MS). The effects of various extraction parameters for the quantitative extraction of these analytes by MA-HS-SPME were systematically investigated and optimized. The analytes in a 20-mL water sample (in a 40-mL sample-vial containing 4 g of NaCl) were efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the system was microwave irradiated at 180 W for less than 4 min. The limits of detection (LODs) ranged from 0.05 to 0.1 ng/L, and the limits of quantification (LOQs) were less than 0.2 ng/L. A preliminary analysis of wastewater samples revealed that HHCB and AHTN were the two most commonly detected synthetic polycyclic musks; using a standard addition method, their concentration were determined to range from 1.2 to 37.3 ng/L with relative standard deviation (RSD) ranging from 2 to 6%. The results obtained using this approach are better than those from the conventional oil-bath HS-SPME.  相似文献   

13.
This investigation evaluates headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) to determine trace levels of organotins in water. The organotins were derivatized in situ with sodium tetraethylborate and adsorbed on a poly(dimethysiloxane) (PDMS)-coated fused silica fiber. The SPME experimental procedures to extract organotins in water were at pH 5, with extraction and derivatization simultaneously at 45 degrees C for 30 min in a 2% sodium tetraethylborate solution and a sample solution volume in the ratio of 1:1, and desorption in the splitless injection port of the GC at 260 degrees C for 2 min. Detection limits are determined to be in the low ng/L range. According to the analysis, the linearity range is from 10 to 10,000 ng/L with R.S.D. values below 12% except triphenyltin (24%). The proposed method was tested by analyzing surface seawater from the harbors on the Taiwanese coast for organotins residues. Some organotins studied were detected in the analyzed samples. Results of this study demonstrate the adequacy of the headspace SPME-GC-MS method for analyzing organotins in sea water samples.  相似文献   

14.
This study proposes the use of deuterated phthalates as internal standards for the accurate determination of phthalates in wine by headspace solid-phase microextraction followed by gas chromatography-mass spectrometry. Unlike other internal standards proposed previously such as benzyl benzoate, deuterated phthalates enabled matrix-error free determinations to be performed without standard addition because statistically equal slopes were obtained for synthetic, white, rose and red wines. The relative standard deviation values under intermediate precision conditions ranged from 0.24 to 4.6%, and detection limits below 35 ng L(-1) were obtained. Recovery values were around 100% in most of cases and the method provided similar results to standard addition. Finally, the method was used to screen phthalate levels in 10 wine samples.  相似文献   

15.
16.
A relatively noninvasive method consisting of a face mask sampling device, solid-phase microextraction (SPME) fibers, and a gas chromatography-mass spectrometry (GC-MS) for the identification of volatile organic compounds (VOCs) in bovine breath was developed. Breath of three morbid steers with respiratory tract infections and three healthy steers were sampled seven times in 19 days for 15 min at each sampling. The breath VOCs adsorbed on the divinylbenzene (DVB)-Carboxen-polydimethyl siloxane (PDMS) 50/30 microm SPME fibers were transported to a laboratory GC-MS system for separation and identification with an in-house spectral library of standard chemicals. A total of 21 VOCs were detected, many of them for the first time in cattle breath. Statistical analyses using Chi-square test on the frequency of detection of each VOC in each group was performed. The presence of acetaldehyde (P < or = 0.05) and decanal (P < or = 0.10) were associated more with clinically morbid steers while methyl acetate, heptane, octanal, 2,3-butadione, hexanoic acid, and phenol were associated with healthy steers at P < or = 0.10. The results suggest that noninvasive heath screening using breath analyses could become a useful diagnostic tool for animals and humans.  相似文献   

17.
A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.  相似文献   

18.
The possibility of quantitative analysis of aromatic hydrocarbons in oil-based asphalt release agents was investigated using headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). The target analytes studied were benzene, toluene, ethylbenzene, p-, m-, and o-xylene (BTEX) and 1,3,5-trimethylbenzene and 1,2,4-trimethylbenzene. Experimental parameters influencing HS-SPME efficiency were studied (equilibration time between sample and headspace and between headspace and SPME fiber, sample amount and sample matrice effects). A HS-SPME method using hexadecane as a surrogate matrice was developed. The detection limit was estimated as 0.03-0.08 ppm (w/w) for the target analytes investigated. Good linearity was observed (R2 > 0.999) for all calibration curves at high, medium and low concentration level. The repeatability of the method (RSD, relative standard deviation) was found to be less than 10% (generally less than 5%) in triplicate samples and approximately 2% at eight consecutive tests on one and the same sample. The accuracy of the method given by recovery of spiked samples was between 85 and 106% (generally between 95 and 105%). The HS-SPME method developed was applied to four commercially available asphalt release agents. External calibration and standard addition approaches were investigated regarding accuracy. The results showed that standard addition generates higher accuracy than external calibration. The contents of target aromatic hydrocarbons in the asphalt release agents studied varied greatly from approximately 0.1-700 ppm. The method described looks promising, and could be a valuable tool for determination of aromatic hydrocarbons in different types of organic matrices.  相似文献   

19.
采用顶空固相微萃取和气相色谱 质谱单离子监测技术,以己二酸二(1 丁基戊基)酯为内标,对水中的己二酸二乙酯、己二酸二异丁酯、己二酸二丁酯、己二酸二(2 丁氧基乙基)酯、己二酸二(乙基己基)酯进行了测定,考察了盐效应、萃取温度、萃取时间和热解吸时间等因素对方法灵敏度的影响。该方法对5种己二酸酯的检测限量为0.0220~5.49μg L,回收率为86.9%~102.0%,相对标准偏差为1.5%~7.3%。  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号