首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Utilizing linear solvation free energy relationship methodology, a novel pyridinium bromide surface confined ionic liquid (SCIL) stationary phase was characterized under normal phase high-performance liquid chromatographic conditions. A limited set of neutral aromatic probe solutes were utilized to rapidly assess the utility of the LSER model, using mobile phases of hexane modified with 2-propanol. The excellent correlation of the global fit across the mobile phase composition range used in this study for the experimental and calculated retention values (R(2)=0.994) indicates that the LSER model is an appropriate model of characterizing this polar bonded phase under normal phase conditions. For a limited subset of compounds, retention on the pyridinium bromide SCIL stationary phase is more highly correlated with that obtained on a cyano column than on a diol column under NP conditions.  相似文献   

2.
We recently introduced a mixed-mode reversed-phase/weak anion-exchange type separation material based on silica particles which consisted of a hydrophobic alkyl strand with polar embedded groups (thioether and amide functionalities) and a terminal weak anion-exchange-type quinuclidine moiety. This stationary phase was designed to separate molecules by lipophilicity and charge differences and was mainly devised for peptide separations with hydroorganic reversed-phase type elution conditions. Herein, we demonstrate the extraordinary flexibility of this RP/WAX phase, in particular for peptide separations, by illustrating its applicability in various chromatographic modes. The column packed with this material can, depending on the solute character and employed elution conditions, exploit attractive or repulsive electrostatic interactions, and/or hydrophobic or hydrophilic interactions as retention and selectivity increments. As a consequence, the column can be operated in a reversed-phase mode (neutral compounds), anion-exchange mode (acidic compounds), ion-exclusion chromatography mode (cationic solutes), hydrophilic interaction chromatography mode (polar compounds), and hydrophobic interaction chromatography mode (e.g., hydrophobic peptides). Mixed-modes of these chromatographic retention principles may be materialized as well. This allows an exceptionally flexible adjustment of retention and selectivity by tuning experimental conditions. The distinct separation mechanisms will be outlined by selected examples of peptide separations in the different modes.  相似文献   

3.
Adopting a stationary phase convention circumvents problematic definition of the boundary between the stationary and the mobile phase in the liquid chromatography, resulting in thermodynamically consistent and reproducible chromatographic data. Three stationary phase definition conventions provide different retention data, but equal selectivity: (i) the complete solid phase moiety; (ii) the solid porous part carrying the active interaction centers; (iii) the volume of the inner column pores. The selective uptake of water from the bulk aqueous‐organic mobile phase significantly affects the volume and the properties of polar stationary phases. Some polar stationary phases provide dual‐mode retention mechanism in aqueous‐organic mobile phases, reversed‐phase in the water‐rich range, and normal‐phase at high concentrations of the organic solvent in water. The linear solvation energy relationship model characterizes the structural contributions of the non‐selective and selective polar interactions both in the water‐rich and organic solvent‐rich mobile phases. The inner‐pore convention provides a single hold‐up volume value for the retention prediction on the dual‐mode columns over the full mobile phase range. Using the dual‐mode monolithic polymethacrylate zwitterionic micro‐columns alternatively in each mode in the first dimension of two‐dimensional liquid chromatography, in combination with a short reversed‐phase column in the second dimension, provides enhanced sample information.  相似文献   

4.
A novel organic‐silica hybrid monolith was prepared through the binding of histidine onto the surface of monolithic matrix for mixed‐mode per aqueous and ion‐exchange capillary electrochromatography. The imidazolium and amino groups on the surface of the monolithic stationary phase were used to generate an anodic electro‐osmotic flow as well as to provide electrostatic interaction sites for the charged compounds at low pH. Typical per aqueous chromatographic behavior was observed in water‐rich mobile phases. Various polar and hydrophilic analytes were selected to evaluate the characteristics and chromatographic performance of the obtained monolith. Under per aqueous conditions, the mixed‐mode mechanism of hydrophobic and ion‐exchange interactions was observed and the resultant monolithic column proved to be very versatile for the efficient separations of these polar and hydrophilic compounds (including amides, nucleosides and nucleotide bases, benzoic acid derivatives, and amino acids) in highly aqueous mobile phases. The successful applications suggested that the histidine‐modified organic‐silica hybrid monolithic column could offer a wide range of retention behaviors and flexible selectivities toward polar and hydrophilic compounds.  相似文献   

5.
Immobilized artificial membranes (IAMs) prepared from phosphatidylcholine analogs are used as stationary phases in liquid chromatography systems to model drug partitioning between an aqueous phase (mobile phase) and a cell membrane (IAM column). Two different chromatographic models, which describe retention as a function of solute and column-mobile phase properties, have been applied to characterization of an IAM and two reversed phase C18 columns (Waters XTerra MSC18 and XTerra RP18) with acetonitrile-water mobile phases. The comparison of the results shows that the phosphatidylcholine group makes IAM column more polar than both XTerra columns, specially in terms of hydrogen-bond acceptor ability. XTerra RP18 is slightly more polar than XTerra MSC18 because of the presence of the embedded carbamate polar group.  相似文献   

6.
In this study, the retention behavior of selected hydrophobic and polar bases on a minimally modified silica hydride phase was investigated. From these results and the associated retention plots, significant differences in the chromatographic dependencies of these two classes of basic compounds were evident. The polar bases exhibited strong retention with mobile phases of high organic solvent content, but displayed weak retention with mobile phases of high water content. In contrast, the hydrophobic bases showed “U‐shape” retention dependencies, indicative of the interplay of both RP and normal‐phase retention characteristics. These studies have demonstrated that hydrophobic and polar bases can be simultaneously separated on the same column either under typical RP‐like or aqueous normal‐phase‐like conditions, respectively, with distinctive selectivity. Finally, the effects of temperature on the RP and aqueous normal phase modality of separations with these analytes were investigated, where discrete changes in retention behavior were also observed.  相似文献   

7.
Summary Fourier-transform infrared spectrometry (FTIR) was utilized as a detection system for high-performance liquid chromatography of polar compounds on a normal bonded-phase system. In addition to FTIR, UV (254 nm) and refractive index detection were employed in the separation of model compounds containing oxygen and nitrogen atoms in their molecules (phenols, alcohols, neutral and weakly basic nitrogen compounds). A polar amino-cyano (PAC) bonded-phase column was employed with a binary mobile phase (98:2 CDCl3:CH3CN). The separations and the information gained from each detector is discussed, including interactions between sample material and mobile phase. A polar fraction of a coal-derived product is also chromatographed under identical conditions. The results based on FTIR detection and chromatographic retention behavior suggest the exclusive presence of hindered and unhindered phenols.  相似文献   

8.
The aim of this study was to evaluate the applicability of ODS-AQ packing material as a stationary phase in capillary electrochromatography (CEC). The electroosmotic flow created on an ODS-AQ stationary phase was measured at different mobile phase compositions and at different column temperatures. It was observed that the electroosmotic flow generated in the column increased by 50% when the temperature of the system was raised from 20 degrees C to 60 degrees C, while all other conditions were kept constant. The electroosmotic flow produced by the ODS-AQ stationary phase was found to be comparable to the flow generated in a column packed with Nucleosil bare-silica material. In addition, a set of polar compounds (D-lysergic acid diethylamide derivatives) was utilized to determine the influence of temperature and mobile phase composition on their chromatographic behavior on an ODS-AQ stationary phase in a CEC mode. A linear relationship between the solute retention factor and column temperatures was seen over the temperature range studied (20 degrees C to 60 degrees C). A quadratic function was used to describe the changes in the solute retention factors with variation of acetonitrile concentration in the mobile phase.  相似文献   

9.
黄酮醇异构体的超临界流体色谱法分离   总被引:9,自引:0,他引:9  
刘志敏  赵锁奇  王仁安  杨光华 《色谱》1997,15(4):288-291
用超临界流体色谱法进行了黄酮醇异构体的分离研究。考察了温度、压力、流动相组成、柱条件等对分离的影响。在实验的温度范围40~60℃和压力范围15~30MPa内,这组化合物都能得到很好的分离;流动相组成是影响色谱分离的最显著的因素,磷酸的加入大大改变了各物质的保留行为;考察了三种硅胶基质键合相对分离的影响,发现苯基柱用于这组异构体的分离最为合适。  相似文献   

10.
硅胶色谱柱的亲水作用保留机理及其影响因素   总被引:1,自引:0,他引:1  
李瑞萍  袁琴  黄应平 《色谱》2014,32(7):675-681
亲水作用色谱(HILIC)是替代反相色谱(RPLC)分离强极性及亲水性化合物的另一色谱模式,其分离机理与RPLC有很大不同,具有和RPLC互补的选择性。在HILIC模式中,采用正相色谱(NPLC)中的极性固定相及含高浓度有机溶剂(通常为乙腈)的水溶液为流动相。硅胶是开发最早、研究最为深入及应用最为广泛的HILIC固定相,本文介绍了硅胶色谱柱的HILIC保留机理,详细概述了操作条件如硅胶柱类型、流动相组成及柱温对HILIC分离的影响,并对硅胶填料色谱柱的HILIC模式的发展方向与应用前景进行了展望。  相似文献   

11.
Quantification of neurotransmitters as biologically active analytes in neurological samples is of high interest for studying their effect on multiple targets. This work is part of a strategy involving two-dimensional liquid chromatography (2D LC) system with mass spectrometry (MS) detection. The concept of the on-line LC system is the coupling of reversed phase liquid chromatography (RPLC, the second separation dimension) to ion-exchange chromatography (IEC, the first dimension). Our objective in this study is to find the appropriate second dimension column, ensuring that samples of neurotransmitters are refocused and separated on it. Silica-based columns designed specifically to retain polar compounds were tested in LC conditions and compared with results obtained with a porous graphitic carbon (PGC, Hypercarb) column. These polar embedded, polar endcapped, and high-density alkyl chain columns successfully separated analytes in question using mobile phase systems with high percentage of water, or even pure water. Only Hypercarb column provided efficient retention of the most polar neurotransmitters and could be used for trapping and preconcentrating the compounds without rapid breakthrough.  相似文献   

12.
L. Szepesy  V. Háda 《Chromatographia》2001,54(1-2):99-108
Summary Eight commercially available reversed-phase (RP) columns of widely different characteristics were evaluated and compared using the linear solvation energy relationships (LSER). Retention factors of 32 solutes of different types were determined under isocratic conditions using an acetonitrile-water (30∶70) mobile phase. Stationary phase properties were compared by the fitting coefficients of the LSER-based regression equations which are characteristic of the individual stationary phases and represent the extent of various molecular interactions contributing to the retention process. The good agreement between the calculated and measured logk values for different type of compounds support the adequacy and applicability of the LSER model to describe chromatographic retention. Characterization of column performance for the separation of various type of compounds was established by the determination of the different selectivity factors representing hydrophobic selectivity, polar selectivity and specific selectivity.  相似文献   

13.
The retention behaviour of several triacylglycerols (TAGs) and fats on Hypercarb, a porous graphitic carbon column (PGC), was investigated in liquid chromatography (LC) under isocratic elution mode with an evaporative light scattering detector (ELSD). Mixtures of chloroform/isopropanol were selected as mobile phase for a suitable retention time to study the influence of temperature. The retention was different between PGC and non-aqueous reversed phase liquid chromatography (NARP-LC) on octadecyl phase. The retention of TAGs was investigated in the interval 30-70 degrees C. Retention was greatly affected by temperature: it decreases as the column temperature increases. Selectivity of TAGs was also slightly influenced by the temperature. Moreover, this chromatographic method is compatible with a mass spectrometer (MS) detector by using atmospheric pressure chemical ionisation (APCI): same fingerprints of cocoa butter and shea butter were obtained with LC-ELSD and LC-APCI-MS. These preliminary results showed that the PGC column could be suitable to separate quickly triacylglycerols in high temperature conditions coupled with ELSD or MS detector.  相似文献   

14.
Li Y  Feng Y  Chen T  Zhang H 《Journal of chromatography. A》2011,1218(35):5987-5994
An imidazoline was prepared by solvent-free microwave-assisted organic synthesis and immobilized on porous silica particles by polymerization. The resulting material was composed of both hydrophobic alkyl ester chains and hydrophilic imidazoline rings, which gave it both hydrophilic interaction and reversed-phase characteristics. The titration curve suggests that the new material has buffering capacity and acquires increasing positive charge over the pH range 9-4, and is "zwitterionic" in the upper part of this pH range. Through investigating the effect of column temperature, the water content, pH and ion strength of mobile phase on the retention time of polar compounds in highly organic eluents, it was found that the new material could be used as a hydrophilic interaction liquid chromatography (HILIC) stationary phase which involved a complex retention process consisting of partitioning, surface adsorption and electrostatic interactions. In addition, the retention behavior of aromatic compounds in different mobile phase conditions was also studied, which showed the new material mainly exhibited a partitioning mechanism in the reversed-phase liquid chromatography (RPLC) mode. The separation of six water-soluble vitamins and five aromatic compounds were achieved by using the new material in the HILIC and RPLC modes, respectively.  相似文献   

15.
Li Y  Li J  Chen T  Liu X  Zhang H 《Journal of chromatography. A》2011,1218(11):1503-1508
The mixed sulfated/methacryloyl polysaccharide derivative was prepared and successfully immobilized onto the surface of porous silica particles by polymerization. Polysaccharide derivative was calculated as 10.33% in the stationary phase prepared. The new stationary phase (PMSP) showed both hydrophilic interaction (HILIC) and per aqueous liquid chromatography (PALC) characteristics. The effects of column temperature, the water content, pH and ion strength of mobile phase on the retention time of test compounds in highly aqueous eluents were investigated to evaluate the PALC features of PMSP. The column efficiency is about 31,000 plates/m for benzoic acid in water/ACN (97/3, v/v) mobile phase at a flow rate of 1.0 mL/min. Compared with C18 column, the PMSP had shorter retention time for weak polar and non-polar compounds, but also showed stronger retention for strong polar compounds. It indicated that PALC was a suitable mode of chromatography as replacement of HILIC and complementarity of reversed-phase liquid chromatography (RPLC).  相似文献   

16.
以2-溴异丁酰溴为引发剂,CuCl/CuC12/Me6TREN为催化体系,在室温条件下采用原子转移自由基聚合(ATRP)法将单体6-O-甲基丙烯酰基-1,2,3,4-双-O-亚异丙基-α-D-吡喃半乳糖苷(6-O-methacryloyl-1,2,3,4-di-O-isopropylidene-α-D-galactop...  相似文献   

17.
Summary The influence of the alcohol content of the mobile phase and water, acetic acid and aniline as mobile phase additives on the generation and shape of two additional changes of the streaming current, generated inside the liquid chromatography column by injection of any sample and recorded before the responses of retained solutes, was studied in a normal-phase system using silica gel as the stationary phase. The mobile phases were based on a n-heptane-1-propanol mixtures. Under the same conditions the relationships between the column interparticle volume, the column void volume and the total liquid volume in the column and the retention volumes of these two streaming current responses, having the form of chromatographic peaks, were studied. The column void volume was identified with the retention volume of n-octane. The total liquid volume in the column (column hold-up) was calculated from the weight loss of the column wetted with water at first and then dried in nitrogen stream. The retention volume of the first streaming current response equals the column interparticle volume disregarding the mobile phase composition. If the 95∶5 n-heptane-1-propanol mobile phase contains water up to 80% of its saturated concentration (up to 0.114% by vol.), the retention volume of the second response agrees with the total volume of the liquid in the silica gel column, with a precision better than 2%. At a higher relative water saturation the retention volume of the second response increases, while the column void volume decreases. Both changes are explained by the spontaneous formation of a highly polar stagnant liquid in the pores of the silica gel.  相似文献   

18.
This paper presents a systematic study of the retention behavior of a model bisdioxopiperazine drug, dexrazoxane (DEX) and its three polar metabolites (two single open-ring intermediates-B and C and an EDTA-like active compound ADR-925) on different stationary phases intended for hydrophilic interaction liquid chromatography (HILIC). The main aim was to estimate advantages and limitations of HILIC in the simultaneous analysis of a moderately lipophilic parent drug and its highly polar metabolites, including positional isomers, under MS compatible conditions. The study involved two bare silica columns (Ascentic Express HILIC, Atlantis HILIC) and two stationary phases with distinct zwitterionic properties (Obelisc N and ZIC HILIC). The chromatographic conditions (mobile phase strength and pH, column temperature) were systematically modified to assess their impact on retention and separation of the studied compounds. It was found that the bare silica phases were unable to separate the positional isomers (intermediates B and C), whereas both columns with zwitterionic properties (Obelisc N and ZIC HILIC) were able to separate these structurally very similar compounds. However, only ZIC HILIC phase allowed appropriate separation of DEX and all its metabolites to a base line within a single run. A mobile phase composed of a mixture of ammonium formate (0.5 mM) and acetonitrile (25:75, v/v) was suggested as optimal for the simultaneous analysis of DEX and its metabolites on ZIC HILIC. Thereafter, HILIC-LC-MS analysis of DEX and all its metabolites was performed for the first time to obtain basic data about the applicability of the suggested chromatographic conditions. Hence, this study demonstrates that HILIC could be a viable solution for the challenging analysis of moderately polar parent drug along with its highly polar metabolites including the ability to separate structurally very similar compounds, such as positional isomers.  相似文献   

19.
成晓东  张铮 《应用化学》2019,36(6):726-732
利用异氰酸丙基三乙氧基硅烷与L-异亮氨酸反应合成了一种新型的硅烷偶联剂,并进一步将其与硅胶反应制得键合有L-异亮氨酸的亲水色谱固定相。 通过核磁共振氢谱表明亮氨酸功能化硅烷偶联剂的成功合成、元素分析表征证明亮氨酸已成功键合到硅胶表面。 将其作为亲水模式下的固定相填料填装在150 mm×4.6 mm不锈钢色谱柱中,以一系列经典的极性小分子作为探针,考察了这些探针分子在固定相上的色谱行为。 极性化合物的保留时间随着流动相中有机溶剂含量提高而逐渐增大,表现出典型的亲水保留特征。 进一步研究了流动相中乙腈含量、缓冲盐pH值及缓冲盐浓度等因素对分析物在固定相上的保留的影响。 在优化了相关参数后,将固定相应用于碱性化合物、水溶性维生素以及核苷类极性物质的分离当中。 在等度洗脱下,5种碱性化合物、6种水溶性维生素和8种核苷类物质分别在8、18及25 min内被成功分离。 分离结果表明了合成的L-异亮氨酸键合亲水色谱固定相具有较好的色谱性能,在极性化合物的分离上具有良好的应用前景。  相似文献   

20.
High-performance liquid chromatography enantioseparation of vesamicol and six novel azaspirovesamicols (amino alcohols) was accomplished on different chiral stationary phases (CSPs) by using an optical rotation based chiral detector for identification of the resolved enantiomers. The Pirkle-type column Reprosil Chiral-NR was found to be most suitable for chiral resolution in normal phase (NP) mode; all compounds could be enantioseparated successfully. Also the cellulose-based column Reprosil Chiral-OM showed appropriate separation properties by using NP conditions. The amylose-type column Reprosil Chiral-AM-RP was most suitable for enantioseparation in reversed phase (RP) mode; five out of seven compounds were resolved. This CSP showed a considerably higher capability for chiral recognition of vesamicol derivatives in RP mode than the corresponding cellulose-based column Reprosil Chiral-OM-RP. Enantioseparation with the teicoplanin aglycone-based column Reprosil Chiral-AA was successful under polar ionic mobile phase conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏