首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

A novel SBA-15-based fluorescent sensor, SBA-PI: mesoporous SBA-15 structure modified with iminostilbene groups, was designed, synthesized, and characterized by Fourier transform-infrared spectroscopy (FT-IR), ultraviolet–visible spectroscopy, field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), thermogravimetric analysis (TGA), low-angle X-ray diffraction techniques (low-angle XRD), and N2 adsorption–desorption techniques. The SBA-PI as a sensor with a selective behavior for detection of Cu2+ comprises iminostilbene carbonyl as the fluorophore group. The SBA-PI sensor displays an excellent fluorescence response in aqueous solutions and the fluorescence intensity quenches remarkably upon addition of Cu2+. Other common interfering ions even at high concentration ratio showed either no or very small changes in the fluorescence intensity of SBA-PI in the absence of Cu2+. A limit of detection of 8.7 × 10−9 M for Cu2+ indicated that this fluorescence sensor has a high sensitivity and selectivity toward the target copper (II) ion. The fabricated Cu2+ sensor was successfully applied for the determination of the Cu2+ in human blood samples without any significant interference. With the selective analysis of Cu2+ ions down to 0.9 nM in blood, the sensor is a promising and a novel detection candidate for Cu2+ and can be applied in the clinical laboratory. A reversibility and accuracy in the fluorescence behavior of the sensor was found in the presence of I¯ that was described as a masking agent for Cu2+.

Graphical abstract

  相似文献   

2.

Graphite electrodes were modified with triangular (AuNTrs) or spherical (AuNPs) nanoparticles and further modified with fructose dehydrogenase (FDH). The present study reports the effect of the shape of these nanoparticles (NPs) on the catalytic current of immobilized FDH pointing out the different contributions on the mass transfer–limited and kinetically limited currents. The influence of the shape of the NPs on the mass transfer–limited and the kinetically limited current has been proved by using two different methods: a rotating disk electrode (RDE) and an electrode mounted in a wall jet flow-through electrochemical cell attached to a flow system. The advantages of using the wall jet flow system compared with the RDE system for kinetic investigations are as follows: no need to account for substrate consumption, especially in the case of desorption of enzyme, and studies of product-inhibited enzymes. The comparison reveals that virtually identical results can be obtained using either of the two techniques. The heterogeneous electron transfer (ET) rate constants (kS) were found to be 3.8 ± 0.3 s−1 and 0.9 ± 0.1 s−1, for triangular and spherical NPs, respectively. The improvement observed for the electrode modified with AuNTrs suggests a more effective enzyme-NP interaction, which can allocate a higher number of enzyme molecules on the electrode surface.

The shape of gold nanoparticles has a crucial effect on the catalytic current related to the oxidation of D-(-)-fructose to 5-keto-D-(-)-fructose occurring at the FDH-modified electrode surface. In particular, AuNTrs have a higher effect compared with the spherical one.

  相似文献   

3.

The cyanate anion (CNO), formed spontaneously within cells from urea and carbamoyl phosphate, usually functions as a biomarker of some diseases such as chronic kidney disease. Therefore, accurate determination of CNO is highly demanded. Herein, a 3-amino-2-naphthoic acid-based “turn-on” fluorescence probe was developed for specific detection of CNO. Upon the addition of sodium cyanate, the weak-fluorescent 3-amino-2-naphthoic acid could react with CNO, which triggered intense emission of green fluorescence. And up to 9-fold fluorescence enhancement was observed. The fluorescence enhancement ratios displayed a good linear relationship with the concentrations of CNO in the range of 0.5–200 μM. The high selectivity and sensitivity for CNO detection were investigated with the detection limit as low as 260 nM. The probe was further successfully applied to determine CNO in real samples such as tap water, human urine and serum samples, which offered a promising approach in practical applications.

Graphical abstract

  相似文献   

4.

A novel rhodamine–tryptamine conjugate–based fluorescent and chromogenic chemosensor (RTS) for detection of Hg2+ present in water was reported. After gradual addition of Hg2+ in aqueous methanol solution of RTS, a strong orange fluorescence and deep-pink coloration were observed. The probe showed high selectivity towards Hg2+ compared to other competitive metal ions. The 1:1 binding stoichiometry between RTS and Hg2+ was established by Job’s plot analysis and mass spectroscopy. Initial studies showed that the synthesized probe RTS possessed fair non-toxicity and effectively passed through cell walls of model cell systems, viz., human neuroblastoma (SHSY5Y) cells and cervical cells (HeLa) to detect intercellular Hg2+ ions, signifying its utility in biological system. The limit of detection (LOD) was found to be 2.1 nM or 0.42 ppb by fluorescence titration. Additionally, the potential relevance of synthesized chemosensor for detecting Hg2+ ions in environmental water samples has been demonstrated.

  相似文献   

5.

The i-motif is a biologically relevant non-canonical DNA structure formed by cytosine-rich sequences. Despite the importance of the factors affecting the formation/stability of such a structure, like pH, cation type and concentration, no systematic study that simultaneously analysed their effect on the i-motif in vitro has been carried out so far. Therefore, here we report a systematic study that aims to evaluate the effect of these factors, and their possible interaction, on the formation of an i-motif structure. Our results confirm that pH plays the main role in i-motif formation. However, we demonstrate that the effect of the cation concentration on the i-motif is strictly dependent on the pH, while no significant differences are observed among the investigated cation types.

Graphical abstract

  相似文献   

6.

In this label-free surface-enhanced Raman scattering (SERS) study of genomic DNA, we demonstrate that the cancer-specific DNA methylation pattern translates into specific spectral differences. Thus, DNA extracted from an acute myeloid leukemia (AML) cell line presented a decreased intensity of the 1005 cm−1 band of 5-methylcytosine compared to normal DNA, in line with the well-described hypomethylation of cancer DNA. The unique methylation pattern of cancer DNA also influences the DNA adsorption geometry, resulting in higher adenine SERS intensities for cancer DNA. The possibility of detecting cancer DNA based on its SERS spectrum was validated on peripheral blood genomic DNA samples from n = 17 AML patients and n = 17 control samples, yielding an overall classification of 82% based on the 1005 cm−1 band of 5-methylcytosine. By demonstrating the potential of SERS in assessing the methylation status in the case of real-life DNA samples, the study paves the way for novel methods of diagnosing cancer.

Graphical abstract

  相似文献   

7.

We report a novel, fast, and automatic SPME-based method capable of extracting a small molecule-drug conjugate (SMDC) from biological matrices. Our method relies on the extraction of the drug conjugate followed by direct elution into an electrospray mass spectrometer (ESI-MS) source for qualitative and quantitative analysis. We designed a tool for extracting the targeting head of a recently synthesized SMDC, which includes acetazolamide (AAZ) as high-affinity ligand specific to carbonic anhydrase IX. Specificity of the extraction was achieved through systematic optimization. The design of the extraction tool is based on noncovalent and reversible interaction between AAZ and CAII that is immobilized on the SPME extraction phase. Using this approach, we showed a 330% rise in extracted AAZ signal intensity compared to a control, which was performed in the absence of CAII. A linear dynamic range from 1.2 to 25 μg/ml was found. The limits of detection (LOD) of extracted AAZ from phosphate-buffered saline (PBS) and human plasma were 0.4 and 1.2 μg/ml, respectively. This with a relative standard deviation of less than 14% (n = 40) covers the therapeutic range.

Graphical abstract

  相似文献   

8.

A biomass nitrogen and sulfur codoped carbon dots (NS-Cdots) was prepared by a simple and clean hydrothermal method using leek, and was employed as efficient fluorescent probes for sensitive detection of organophosphorus pesticides (OPs). The leek-derived NS-Cdots emitted blue fluorescence, but was quenched by H2O2. Due to acetylcholinesterase/choline oxidase–based cascade enzymatic reaction that produces H2O2 and the inhibition effect of OPs on acetylcholinesterase activity, a NS-Cdots-based fluorescence “off-on” method to detect OPs-dichlorvos (DDVP) was developed. More sensitivity and wider linear detection range were achieved from 1.0 × 10−9 to 1.0 × 10−3 M (limit of detection = 5.0 × 10−10 M). This developed method was applied to the detection of DDVP in Chinese cabbage successfully. The average recoveries were in the range of 96.0~104.0% with a relative standard deviation of less than 3.3%. In addition, the NS-Cdots fluorescent probes were also employed successfully in multicolor imaging of living cells, manifesting that the NS-Cdots fluorescent probes have great application potential in agricultural and biomedical fields.

Graphical Abstract

  相似文献   

9.

A multichannel chip containing 16 microchambers was developed for fast and sensitive immunoassays. In each chamber, antibody-functionalized nonmagnetic beads were applied as the solid phase to capture target antigens. Four types of IgGs (human, rabbit, chicken, and mouse) could be detected simultaneously by our combining this microchip with a sandwich immunoassay technique. A three-layer chip structure was investigated for integration of multiple processes, including washing, immune reaction, and detection, in one microchip. Moreover, the proposed chip design could improve batch-to-batch repeatability and avoid interferences between different channels without the preparation of complex microvalves. The total operation time of this system was less than 30 min, with a desirable detection limit of 0.2 pg/mL. The results indicate that the microfluidic platform is promising for the immunoassay of multiple clinical biomarkers.

Graphical abstract

  相似文献   

10.

In this work, a straightforward analytical approach based on headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry was developed for the analysis of salivary volatile organic compounds without any prior derivatization step. With a sample volume of 500 μL, optimal conditions were achieved by allowing the sample to equilibrate for 10 min at 50 °C and then extracting the samples for 10 min at the same temperature, using a carboxen/polydimethylsiloxane fibre. The method allowed the simultaneous identification and quantification of 20 compounds in sample headspace, including short-chain fatty acids and their derivatives which are commonly analysed after analyte derivatization. The proof of applicability of the methodology was performed with a case study regarding the analysis of the dynamics of volatile metabolites in saliva of a single subject undergoing 5-day treatment with rifaximin antibiotic. Non-stimulated saliva samples were collected over 3 weeks from a nominally healthy volunteer before, during, and after antibiotic treatment. The variations of some metabolites, known to be produced by the microbiota and by bacteria that are susceptible to antibiotics, suggest that the study of the dynamics of salivary metabolites can be an excellent indirect method for analysing the gut microbiota. This approach is novel from an analytical standpoint, and it encourages further studies combining saliva metabolite profiles and gut microbiota dynamics.

Graphical abstract

  相似文献   

11.

Testosterone in human serum is commonly tested in clinical laboratories using immunoassay methods as well as liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. To standardize and ensure the accuracy of the measurement results, reference procedures with higher metrological order are required. A simple measurement procedure based on one-step liquid-liquid extraction (LLE) and liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) was developed for total testosterone in human serum. The procedure involved serum spiked with 13C3-testosterone, equilibration for 2 h, and extraction with an organic solvent. Testosterone certified reference material (CRM) was used as the calibration standard to ensure the traceability to the International System of Units (SI). Testosterone in serum CRMs from the National Institute for Standards and Technology (NIST) and LGC were used to validate the accuracy of the newly developed method. The deviations of the obtained values from the NIST and LGC certified values ranged from −0.55% to 0.45%. Similarly, the coefficient of variations (CVs) of the replicate measurements were in the range of 0.55% and 0.78%, respectively. The relative expanded uncertainties were comparable with those of the certified materials. The newly developed LC-IDMS/MS procedure demonstrated adequate trueness and precision, and was simple to perform. The method can be used for value assignment of testosterone in external quality assessment (EQA) materials as well as certification of CRMs in the future.

Graphical abstract

  相似文献   

12.

Choosing an appropriate ion source is a crucial step in liquid chromatography mass spectrometry (LC/MS) method development. In this paper, we compare four ion sources for LC/MS analysis of 40 pesticides in tomato and garlic matrices. We compare electrospray ionisation (ESI) source, thermally focused/heated electrospray (HESI), atmospheric pressure photoionisation (APPI) source with and without dopant, and multimode source in ESI mode, atmospheric pressure chemical ionisation (APCI) mode, and combined mode using both ESI and APCI, i.e. altogether seven different ionisation modes. The lowest limits of detection (LoDs) were obtained by ESI and HESI. Widest linear ranges were observed with the conventional ESI source without heated nebuliser gas. In comparison to HESI, ESI source was significantly less affected by matrix effect. APPI ranked second (after ESI) by not being influenced by matrix effect; therefore, it would be a good alternative to ESI if low LoDs are not required.

Graphical abstract

  相似文献   

13.

A high-precision exact-matching quadruple isotope dilution method (ID4MS) was employed for the quantitation of nitrate in an air-dried spinach powder Certified Reference Material (CRM). The analyte was extracted in hot water following addition of 15NO\({}_{3}^{-}\) internal standard. The blend was then treated with sulfamic acid to remove nitrite and with triethyloxonium tetrafluoroborate to promote aqueous conversion of nitrate into volatile EtONO2. The derivative was analyzed by headspace GC–MS with 3-min elution time. The method performance was validated with a series of tests which demonstrated adequate selectivity and ruggedness. This method supported the development of novel SPIN-1 CRM giving a modest contribution to its uncertainty (uchar = 0.85%). With respect to previous attempts, the SPIN-1 was proven stable, homogeneous (uhom = 0.44%), and suitable for spinach monitoring under EU regulations. On dried basis, the nitrate content of SPIN-1 was found to be 22.53 ± 0.43 mg/g (Uc = 1.9%, k = 2). The material was also used in an inter-laboratory study where four laboratories employed a total of ten measurement methods.

SPIN-1 Certified Reference Material for nitrate in spinach powder

  相似文献   

14.
Qu  Qi  Lv  Yaying  Liu  Lingling  Row  Kyung Ho  Zhu  Tao 《Analytical and bioanalytical chemistry》2019,411(28):7489-7498

Hydrophilic and hydrophobic deep eutectic solvents (DESs) as “green” solvents were applied in this study for the microextraction of environmental samples. A series of DESs (five hydrophilic and three hydrophobic) were synthesized and characterized by Fourier transform infrared spectroscopy. Physicochemical property parameters of eight DESs including water solubility, density, conductivity, and freezing point were assessed. Compared with the performance of five hydrophilic DESs in water phase, the three hydrophobic DESs were more suitable for application in dispersive liquid-liquid microextraction for the determination of sulfonamides in water sample. In dispersive liquid-liquid microextraction process, analytical parameters including type and volume of extraction solvent, extraction time, and pH of water sample were investigated. Under optimum conditions, 60 μL of hydrophobic DESs was used for extraction for 2 min in pH = 7.0 sample. The linear ranges were 0.05–5.0 μg/mL for the four sulfonamides with the correlation coefficients in the range of 0.9991–0.9999. The limits of detection were in the range of 0.0005–0.0009 μg/mL and the limits of quantification were in the range of 0.0019–0.0033 μg/mL. The recoveries of the analytes of the proposed method for the spiked samples were 80.17–93.5%, with the relative standard deviation less than 6.31%. The results indicated that three hydrophobic DESs showed commendable performance for extraction of sulfonamides, and hydrophobic DES-based microextraction method was successfully applied for monitoring sulfonamides in water samples.

Graphical abstract

  相似文献   

15.
16.

A phonon band calculation scheme based on our previously proposed coarse-graining theory under periodic boundary conditions was formulated. Starting with a simple one-dimensional, one-body periodic system, we introduced the basis set of a phase-shift coordinate system that can easily afford the discrete Fourier transformation of vectors and matrices with infinite dimensions. When the unit cell contains two or more bodies, the basis set of the phase-shift coordinate system is represented with tensors. By choosing an appropriate tensor basis set of a coarse-grained space, we can approximately block-diagonalize the dynamical matrix. Then, we can obtain the inertia and stiffness matrices represented by the given coarse-grained coordinate system, upon which the application of the mass-weighted Hessian equation affords a set of angular frequencies (ω) as functions of the wavenumber (k). Thus, the phonon band structure (kω plot) is obtained based on the coarse-graining approximation. When this approximation is applied to molecular assemblies comprising hydrogen bonding, the computational error resulting from this scheme is expected to be a maximum of a few cm?1.

Graphical abstract
  相似文献   

17.

A new class of magnetic ionic liquids (MILs) with metal-containing cations was applied in in situ dispersive liquid–liquid microextraction (DLLME) for the extraction of long and short double-stranded DNA. For developing the method, MILs comprised of N-substituted imidazole ligands (with butyl-, benzyl-, or octyl-groups as substituents) coordinated to different metal centers (Ni2+, Mn2+, or Co2+) as cations, and chloride anions were investigated. These water-soluble MILs were reacted with the bis[(trifluoromethyl)sulfonyl]imide anion during the extraction to generate a water-immiscible MIL capable of preconcentrating DNA. The feasibility of combining the extraction methodology with anion-exchange high-performance liquid chromatography with diode array detection (HPLC-DAD) or fluorescence spectroscopy was studied. The method with the Ni2+- and Co2+-based MILs was easily combined with fluorescence spectroscopy and provided a faster and more sensitive method than HPLC-DAD for the determination of DNA. In addition, the method was compared to conventional DLLME using analogous water-immiscible MILs. The developed in situ MIL-DLLME method required only 3 min for DNA extraction and yielded 1.1–1.5 times higher extraction efficiency (EFs) than the conventional MIL-DLLME method. The in situ MIL-DLLME method was also compared to the trihexyl(tetradecyl)phosphonium tris(hexafluorocetylaceto)nickelate(II) MIL, which has been used in previous DNA extraction studies. EFs of 42–99% were obtained using the new generation of MILs, whereas EFs of only 20–38% were achieved with the phosphonium MIL. This new class of MILs is simple and inexpensive to prepare. In addition, the MILs present operational advantages such as easier manipulation in comparison to hydrophobic MILs, which can have high viscosities. These MILs are a promising new class of DNA extraction solvents that can be manipulated using an external magnetic field.

Magnetic ionic liquids with metal-containing cations are applied in in situ dispersive liquid–liquid microextraction for the extraction of long and short double-stranded DNA

  相似文献   

18.

This paper reports on the use of a novel microcapillary system for solid contact electrochemical measurements. The probe is made of moveable micropipettes, with orifice of 1–30-μm radii, filled with a conducting hydrogel, which forms a thin-gelled meniscus at the pipette end. The hydrogel is made of 2 % (w/v) agarose and water solutions, containing KCl or KNO3 as supporting electrolytes. The micropipette can be brought in contact with a conducting substrate to form a microcell, which allows performing voltammetric measurements confined within limited contact regions. The suitability of the proposed probe for local electrochemical measurements are tested using two electroactive species, dissolved in the hydrogel, namely [Fe (CN6)]4- and Ag+ ions. Mass transport characteristics of the two species, in bulk hydrogel and at micropipette meniscuses of different radii, are examined in detail in the frame of existing theory. For comparison, voltammetric measurements are also performed with micropipettes filled with the corresponding aqueous solutions. It is shown that the gel-filled micropipette, at variance with the aqueous one, prevents the spreading and leakage of solution on the sample surface. The microprobe developed here can be useful to perform electrochemical measurements on surfaces, which suffer from direct contact with liquid electrolytes. A proof-of-concept hydrogel-capillary measurement is performed to distinguish the presence of metallic silver deposited on a graphite-on-paper–based material, realized through simple pencil strokes.

Graphical abstract

  相似文献   

19.
Shen  Xing  Zhang  Haiting  He  Xiaolong  Shi  Honglan  Stephan  Chady  Jiang  Hua  Wan  Cuihong  Eichholz  Todd 《Analytical and bioanalytical chemistry》2019,411(21):5531-5543

Single cell-inductively coupled plasma-mass spectrometry (SC-ICP-MS) is an emerging technology. In this work, we have developed a novel SC-ICP-MS method to quantify metal ions in individual cells of a toxic cyanobacterial species, Microcystis aeruginosa (M. aeruginosa), without complicated post-dosing sample preparation, and applied this method to study the treatment effectiveness of copper-based algaecides (cupric sulfate and EarthTec®) on the toxic algae M. aeruginosa. The developed SC-ICP-MS method uses new intrinsic metal element magnesium to determine real transport efficiency and cell concentration. The cell viability and microcystin-LR release by algaecide treatment were studied by flow cytometry and ultra-fast liquid chromatography-tandem mass spectrometry, respectively. The results showed that this novel method was very rapid, highly sensitive (detection limits of intracellular copper and magnesium were 65 ag/cell and 98 ag/cell, respectively), and reproducible (relative standard deviation within 12%). The algaecide effectiveness study further demonstrated that copper in the forms of cupric sulfate and copper-based algaecide EarthTec® successfully diminished M. aeruginosa populations. The higher the copper concentration used to treat the cells, the faster the speeds of copper uptake and cell lysis in the copper concentrations ranged from 0 to 200 μg/L of copper-based algaecide. The cells exhibit obvious heterogeneity in copper uptake. The result suggests that M. aeruginosa cells uptake and cumulate copper followed by cellular lysis and microcystin-LR release. These novel results indicated that though the copper-based algaecides could control this type of harmful algal bloom, further treatment to remove the released algal toxin from the treated water would be needed.

Graphical abstract

  相似文献   

20.
Zhang  Xue  Yu  Hong  Cai  Ya-qi 《Analytical and bioanalytical chemistry》2019,411(16):3427-3434

An ion chromatography and solid-phase extraction method has been applied for the separation and detection of morpholinium cations in environmental water samples. The water samples were purified and enriched by a UF-SCX sulfonic acid extraction column and eluted with 0.5 mol L−1 phosphoric acid/sodium dihydrogen phosphate buffer solution/55% methanol. The target compounds were separated on a carboxylic acid cation exchange column with 5.0 mmol L−1 methane sulfonic acid/2% acetonitrile as the mobile phase and direct conductivity detection. The method has been successfully applied to extract morpholinium cations from spiked water samples of Songhua River, Hulan River, East Lake, and Mopanshan Reservoir in China with the recoveries ranging from 75.0% to 98.3%. The relative standard deviations of intraday precision and interday precision are 2.1% and 5.9% or less, respectively. Using this method it is possible to preconcentrate water samples to 0.01–0.04 mg L−1. The results show that the method is applicable to detection of morpholinium ionic liquid cations in environmental water samples and provides a new approach for monitoring ionic liquids in environmental water.

The analysis procedure of morpholinium ionic liquids in environmental water samples.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号