首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Chromium speciation implies the quantitative determination of Cr(III) and Cr(VI). However, the presence of hydrolytic forms of Cr(III) and the instability of tracer level Cr(VI) in acid media complicates this speciation. The present work describes the stability of several monomeric Cr(III) species formed in the acid reduction of51Cr(VI). The distribution of Cr(VI) and Cr(X)n(H2O) 6–n (3–n)+ as a function of time was followed by paired cationic and anionic exchange analyses. The distributions and their time dependences are functions of the initial concentrations of both Cr(VI) and acid. The Cr(III) species eventually level to the hexaaquo form.  相似文献   

2.
The coordination reactions of bromopyrogallol red (BPR) with tri- and hexavalent chromium in the presence of cetyltrimethylammonium bromide (CTAB) have been studied by absorption spectrometry. Results show that the reactions of Cr(VI) and Cr(III) with BPR in the absence or presence of CTAB have different temperature dependences. The reaction mechanism of Cr(VI) is that Cr(VI) is first reduced by BPR to Cr(III) and then the Cr(III) produced reacts with BPR. Based on the study on the coordination reactions and the effects of surfactants upon them, a simple, rapid, sensitive and accurate method for Cr speciation has been developed. Over the range of 0–8 g Cr(VI) or 0–12g Cr(III) per 25ml final volume, the calibration curve is linear with a detection limit of 3.5 × 10–7 mol/1 for Cr(VI) or 4.4 × 10–7 mol/1 for Cr(III).  相似文献   

3.
Summary 2-Oximinodimedone dithiosemicarbazone reacts with Cr(VI) in strongly acid medium. The orange colour obtained has been used to propose a spectrophotometric method of Cr(VI) determination in the concentration range 0.40–9.5g ml–1 (=5600 mole–1-cm–1 at 485 nm). The stoichiometry of the reaction is 32 (reagentCr(VI)) which is in accordance with the oxidation reaction of the reagent by Cr(VI). The method has been applied to the determination of Cr(VI) and Fe(III) in ceramic materials.
Eine Studie zur Cr(VI)-2-oximinodimedondithiosemicarbazon-Reaktion und die simultane Bestimmung von Cr(VI) und Fe(III)
Zusammenfassung 2-Oximinodimedonedithiosemicarbazon reagiert in stark saurem Milieu mit Cr(VI). Die orange Farbe kann im Konzentrationsbereich von 0.4–9,5g/ml zur spektrophotometrischen Cr(VI)-Bestimmung verwendet werden (=5600 1 mol–1cm–1bei 485 nm). Die Stöchiometrie der Reaktion ist 32 (Reagens: Cr(VI)) und entspricht der Oxidation des Reagens durch Cr(VI). Die Methode wurde zur Bestimmung von Cr(VI) und Fe(III) in keramischen Materialien eingesetzt.
  相似文献   

4.
Summary The pyrolysed graphite L'vov platform of a tube furnace is considered as an electrode for the electrodeposition and speciation of chromium by electrothermal atomisation atomic absorption spectrometry (ETA-AAS). Firstly, a preliminary study of the Cr(VI)/Cr(III) voltammetric behavior at pH 4.70 on a glassy-carbon electrode is carried out. Secondly, the L'vov platform is used as a cathodic macro-electrode for the selective preconcentration of Cr(VI)/Cr(III) on a mercury film. Speciation of Cr(VI)/Cr(III) is carried out on the basis of the electrolysis potential (Ee): at pH 4.70 and Ee=–0.30 V, only Cr(VI) is reduced to Cr(III) and accumulated as Cr(OH)3 by adsorption on a mercury film; at Ee=–1.80 V both Cr(VI) and Cr(III) are accumulated forming an amalgam with added mercury(II) ions. Once the film has been formed, the platform is transferred to a graphite tube to atomise the element. The reliability of the method was tested for the speciation of chromium in natural waters and it proves to be highly sensitive thanks to the electroanalytical step. In all samples, the Cr(VI) concentration was less than the detection limit (0.15 ng ml–1), and the concentration of Cr(III) agrees with those of total chromium. The analytical recovery of Cr(VI) added to water samples [3.50 ng ml–1 of Cr(VI)] was 105±6.2%.  相似文献   

5.
Summary Chromium can be present in aqueous solution as Cr(VI) or in monomeric, dimeric, trimeric and higher polymeric forms of Cr(III). Many monomeric forms of Cr(III) are possible, with the water molecules of Cr(H2O) 6 3+ substituted by anionic or neutral species. This proliferation of Cr(III) species makes the complete speciation of chromium a continuing challenge to the analyst. A simple and effective cation exchange procedure for the separation of various of these species uses a small glass column containing 1 mL of pre-treated cation exchange resin (Na+ form). Stepwise elution with solutions of perchloric acid, Ca2+ (pH=2) and La3+ (pH=2) separates Cr(VI) and seven Cr(III) species from CrX3 to tetramer. Radiometric (Cr-51), spectrophotometric and other detection methods can be employed; the use of radiochromium gives the lowest detection limit.  相似文献   

6.
A procedure is described for the determination of51Cr(III) in51Cr(VI) samples having a51Cr(VI) to51Cr(III) ratio of 105, by means of a single zinc hydroxide coprecipitation at apH of ca. 13. Acceptable precision (standard deviation of 10–15%) is possible with solid51Cr(VI) samples containing 10 ppm of51Cr as51Cr(III).  相似文献   

7.
The speciation of the products from the reaction of51Cr(VI) with concentrated perchloric and trifluoromethanesulfonnic acids was carried out by ion chromatography, using HCIO4 and Ca(CIO4)2 as eluents. The reaction (1 h) of high specific activity51Cr(VI) with 99% CF3SO3H produces 47.6% of the51Cr as a 3+ species (hexaaquochromium(III), 27.6% as a 2+ species and 1.7% as a 1+ species. The reaction with 70% HClO4 gave 82.5% of the51Cr as a 3+ species, 14.0% as a 2+ species and 2.9% as a 1+ species. The 1+ and 2+ species undergo slow reactions to give the hexaaquo form.  相似文献   

8.
The interaction of Cr(VI) and Nitrotetrazolium Blue has been examined. A 12 NTB (CrO3Cl)2 ion-associate is formed and is extractable into 1,2-dichloroethane. The optimum conditions have been established. The molar absorptivity at 260 nm was (8.2 ± 0.06) × 104L mol–1cm–1. Beer's law was obeyed in the range 0.01–0.4 g ml–1 Cr(VI). A sensitive and selective method for determination of micro-quantities of Cr(VI) in soils and steels is suggested.  相似文献   

9.
A chemometric approach to the determination of the components of a redox couple without their preseparation was proposed. The approach is based on the transformation of a potentiometric curve obtained by the multiple addition method to a direct regression line with a cotangent numerically equal to the analyte concentration. The approach was tested on simulated and experimental data for the reversible Fe(III)–Fe(II) system and applied to the determination of Cr(VI) in model solutions using excess solution of the Mohr's salt as an auxiliary reducing agent. In real determinations of Fe(III, II) and Cr(VI) in concentration ranges from 1 × 10–3to n× 10–5and from 2 × 10–3to 5 × 10–4M, RSD varied from 0.2 to 8% and from 3 to 12%, respectively.  相似文献   

10.
Summary Several different configurations for simultaneous and sequential photometric speciation of Cr(VI) and Cr(III) based on the reversed flow injection analysis and completely continuous modes are proposed in this paper. The determination of these species at theg · ml–1 level is achieved with sampling frequencies between 30 and 100 h–1 and an r.s.d. of less than ±1% for simultaneous methods and of less than ±3% for the sequential method. The proposed methods are suitable for chromium speciation in waters. A simulation of the continuous monitoring of Cr(VI) and periodical of Cr(III) in natural and waste waters has been performed. The most frequent interferents in these types of samples have been investigated.
Simultane und sequentielle Bestimmung von Chrom(VI) und Chrom(III) durch unsegmentierte Durchflußmethoden
Zusammenfassung Verschiedene Arten der simultanen und sequentiellen photometrischen Cr(III)- und Cr(VI)-Bestimmung nach der Technik der reversed-flow Injektionsanalyse werden beschrieben. Die relative Standardabweichung für die Bestimmung dieser Chromspezies im g/ml-Bereich bei einer Probenfrequenz von 30 bis 100 je Stunde beträgt weniger als +1% für die Simultan- und weniger als +3% für die sequentiellen Methoden. Eine simulierte kontinuerliche Überwachung von Chrom(VI) sowie eine periodische von Chrom(III) in natürlichem Wasser und Abwasser wird beschrieben. Die häufigsten Störungen werden diskutiert.
  相似文献   

11.
Doğutan M  Filik H  Tor I 《Talanta》2003,59(5):1053-1060
A new melamine based polymeric sequestering resin was prepared for preconcentration and separation of hexavalent chromium from water, and its sequestering action was investigated. The water-insoluble, cross-linked sequestering resin was formed by reaction with bromosuccinic acid and cross-linking of melamine. The active sequestering group on the resin is NH-(Succinic acid) or salt thereof. The resulting chelating resin was characterized by infrared spectra. The newly prepared resin quantitatively retained Cr(VI) at pH 2.0-4.0 when the flow rate was maintained between 1 and 5 ml min−1. The retained Cr(VI) was instantaneously eluted with 25 ml of 0.1 M NaOH. The chromium species were determined by a flame atomic absorption spectrometer. The limits of detection for Cr(VI) and Cr(III) were found to be 5.3 and 4.2 μg l−1, respectively. The precision and accuracy of the proposed procedure was checked by the use synthetic and reference steel samples. The established preconcentration method was successfully applied to the determination and selective separation of Cr(VI) in electroplating industry wastewater. Total concentrations determined by the spectrophotometric method (110.3±0.6 g l−1 Cr(VI) and 1.2±0.3 g l−1 Cr(III)) are compared with those found by FAAS and the obtained results (110.4±1.8 g l−1 Cr(VI) and 1.4±0.5 g l−1 Cr(III)) show good agreement.  相似文献   

12.
Summary Estimation of Cr(VI) in Water, Tannery and Plating Wastes A zirconium tellurite membrane exhibits good selectivity for CrO4 2– or CrO7 2– ions at pH 3–6 and 8–11. Membrane electrode can be used to determine the activity of Cr(VI) ions in the concentration range 10–1 to 7×10–5 M at specified pH. The response time is 30 s and a large number of anions and cations do not interfere with the functioning of this assembly. It has been tried for the estimation of Cr(VI) in plating and tannery waste.  相似文献   

13.
Airborne particulate matter has been sampled at a location close to a metallurgical plant in North-Rhine-Westphalia, Germany, and first results on the chromium(VI) content in the collected dust are presented. A special procedure using a scrubber as sampling device was used to preserve Cr(VI) during the sampling procedure. The scrubber solution which consisted of 0.1 mol L–1 TRIS-buffer solution was adjusted to a slightly alkaline pH of 8.6 to reduce the oxidation potential of Cr(VI) and to avoid possible oxidation of Cr(III) to Cr(VI), for example by oxygen (or ozone at ambient concentrations). After sampling Cr(VI) was pre-concentrated on an anion-exchange material and eluted with aqueous 0.6 mol L–1 sodium perchlorate solution. After elution, a species-selective complex of Cr(VI) with diphenylcarbazide (DPC) was prepared; this was extracted into n-hexanol and quantified by UV–visible spectrophotometry. A detection limit of 0.9 ng m–3 for Cr(VI) in ambient aerosols can be achieved with this method.  相似文献   

14.
In this study, a new method for selective determination of Cr(VI) in water samples at pH 4 is presented using raffinose capped silver nanoparticles (Ag/Raff NPs) as an optical sensor. The method is based on the variation of LSPR absorption band intensity as a result of electrostatic interaction between the negatively charged Ag/Raff NPs and positive Cr(III) ions, in-situ produced by chemical reduction of Cr(VI) with ascorbic acid, combined with the fast kinetics of Cr(III) coordination to the –OH groups of the capping agent on the nanoparticle surface, further causing the nanoparticle aggregation. The calibration curve for Cr(VI) is linear in the range 2.5–7.5 μmol L−1, the limit of quantification achieved is 1.9 μmol L−1, and values of relative standard deviation vary from 3 to 5% for concentration level 1.9–7.5 μmol L−1. The interference studies performed in the presence of various metal ions show very good selectivity of Ag/Raff NPs toward Cr(VI) species. The added–found method is used to confirm the accuracy and precision of developed analytical approach.  相似文献   

15.
An adsorptive stripping voltammetric method for speciation analysis of chromium in natural water samples has been developed. Ethylenediaminetetraacetic acid (EDTA) and diethylenetriaminepentaacetic acid (DTPA) were used as complexing agents for Cr(III) present in the sample and formed as products of Cr(VI) reduction, respectively. Under optimum experimental conditions linear relations in the range from 1×10?6 to 3×10?5 mol L?1 without accumulation and from 1×10?9 to 1×10?7 at 30 s accumulation time were obtained for Cr(III) and Cr(VI), respectively. For samples in which Cr(III) concentration is higher than 1×10?6 mol L?1 the Cr(III) and Cr(VI) were determined simultaneously in one voltammetric cell. For samples in which Cr(III) concentration is below 1×10?6 mol L?1 only Cr(VI) was selectively determined in the presence of Cr(III), which did not influence the Cr(VI) signal. The determination of Cr(III) and Cr(VI) was successful with the application of the proposed procedure in the presence of common foreign ions. The presented method was applied for the speciation of chromium in spiked tap and river water samples with satisfactory results.  相似文献   

16.
Competitive alkali metal cation transport across polymer inclusion membranes (PIMs) containing sym-(alkyl)dibenzo-16-crown-5-oxyacetic acid carriers provides excellent selectivity for Na+ transport with the total fluxes being strongly influenced by the length of the alkyl chain that is attached geminal to the functional side arm in the lariat ether. Removal of chromium(VI) anions by PIMs from acidic aqueous phases was also investigated. Using tri-n-octylamine (TOA) as the ion carrier, Cr(VI) was removed by a PIM to decrease the source phase metal concentration from 1.0 to 0.010 ppm after 30 hours of transport. Competitive transport of Cr(VI) and Cr(III) ions from acidic source phases through PIMs and supported liquid membranes (SLMs) containing TOA and tri-n-octylphosphine oxide (TOPO) as carriers was evaluated and a very high Cr(VI)/Cr(III) separation ratio of 4800 was achieved with a PIM containing TOA. Competitive transport of Zn(II), Cd(II), and Cr(VI) from acidic aqueous solutions through PIMs containing TOA was investigated. The selectivity order for metal ion transport was: HCrO4 >CdCl4 2–+CdCl3 >ZnCl4 2–+ ZnCl3 . Non-contact atomic force microscopy was used to obtain images of the pores in cellulose triacetate membranes containing a plasticizer.  相似文献   

17.
A highly sensitive, selective and simple kinetic method was developed for the determination of dissolved chromium species based on the catalytic effect of Cr(III) and/or Cr(VI) on the oxidation of 2-amino-5-methylphenol (AMP) with H2O2. The fixed time and initial rate variants were used for kinetic spectrophotometric measurements by tracing the oxidized product at 400 nm for 10 min after starting the reaction. Boric acid and Tween-40 exerted pronounced activating and micellar sensitizing effects on the studied redox reaction, respectively. The optimum reaction conditions were: 3.0 mmol l−1 AMP, 0.45 mol l−1 H2O2, 0.50 mol l−1 boric acid, 4 v/v% Tween-40, 10 mmol l−1 phosphate buffer and pH 6.45 ± 0.02 at 35 °C. Both Cr(III) and Cr(VI) ions exerted the same catalytic effect on the studied reaction. Linear calibration graphs were obtained for the determination of up to 6.0 ng ml−1 Cr with detection limits of 0.054 and 0.10 ng ml−1 Cr; following the fixed time and initial rate methods, respectively. The proposed method was successfully applied to the speciation and determination of trace levels of dissolved Cr(III) and Cr(VI) in natural and effluents of industrial waste water. The total dissolved Cr(III) and Cr(VI) species was determined first. In a second run, Cr(VI) was determined alone after precipitation of Cr(III) ions in presence of Al(OH)3 collector, where Cr(III) is then determined by difference. Moreover, published catalytic-spectrophotometric methods for chromium determination were reviewed.  相似文献   

18.
Summary Simultaneous Determination of Chromium(VI) and Chromium(III) by Flame Atomic Absorption Spectrometry with a Chelating Ion-Exchange Flow Injection System A simple method is described for the simultaneous determination of chromium(VI) and chromium(III) in a flow injection system comprising chelating ion-exchange and flame atomic absorption spectrometry. Sampling rates for 2001 and 1 ml sample volumes were 120 and 60 h–1 (240 and 120 speciations per hour), respectively. Typical relative standard deviations were 0.52% for Cr(VI) (0.50g ml–1 and 0.67% for Cr(III) (0.10,g ml–1) and the corresponding limits of detection were 85 ng ml–1, and 16 ng ml–1, respectively.On leave from University of Belgrade.  相似文献   

19.
In this work, polyacrylonitrile/aminated polymeric nanosphere (PAN/APN) nanofibers were prepared by electrospinning of monodispersed aminated polymeric nanospheres (APNs) for removal of Cr(VI) from aqueous solution. Characterization results showed that obtained PAN/APNs possessed nitrogen functionalization. Furthermore, the adsorption application results indicated that PAN/APN nanofibers exhibited a high adsorption capacity of 556 mg/g at 298 K for Cr(VI) removal. The kinetic data showed that the adsorption process fits the pseudo-second order. A thermodynamic study revealed that the adsorption of Cr(VI) was spontaneous and endothermic. The coexisting ions Na+, Ca2+, K+, Cl, NO3 and PO43− had little influence on Cr(VI) adsorption, while SO42− in solution dramatically decreased the removal performance. In the investigation of the removal mechanism, relative results indicated that the adsorption behavior possibly involved electrostatic adsorption, redox reaction and chelation. PAN/APN nanofibers can detoxify Cr(VI) to Cr(III) and subsequently chelate Cr(III) on its surface. The unique structure and nitrogen functionalization of PAN/APN nanofibers make them novel and prospective candidates in heavy metal removal.  相似文献   

20.
Summary The catalytic adsorptive stripping voltammetric determination of chromium using diethylenetriaminepentaacetic acid (DTPA) is only possible when chromium(III) is preliminarily oxidized to chromium(VI) which can be accomplished by UV-irradiation of the oxygen saturated solution at pH 6.0–7.0. A chromium(III)-chromium(VI) speciation can be performed in the range 10–10 mol/l upto 10–6 mol/l employing the coprecipitation of chromium(III) with Al(OH)3. The interference of other metal ions was also studied.  相似文献   