首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A Mycobacterium tuberculosis (MTB) bacilli are still widely spreading and have to be diagnosed fast and efficiently. Therefore, a new simple and rapid method was proposed to detect MTB by the impedance properties of MTB suspensions using interdigitated microelectrodes. As a result, MTB suspensions in deionized (DI) water with different cell concentrations generated different electrical impedance spectral responses. Whereas MTB suspensions in 0.9 wt. % NaCl solution did not produce any significant differences in the impedance spectra in response to different cell concentrations. In DI water suspensions, the impedance at 1 kHz decreased with increasing cell concentrations. The impedance of MTB suspension in DI water has been discussed; it was found to be resulted from the cell wall charges and release of ions from the cells. There was a linear relationship between the impedance and logarithmic value of the cell concentration in the cell concentration range of 102 to 108 cfu/mL, which can be expressed by the regression equation of Z (kΩ) =–456lnN (cfu/mL) + 9717 with R2 = 0.99. Detection limit was calculated as 104 cfu/mL, which is comparable with many label-free immunosensors for detecting pathogenic bacteria reported in the literature. This work demonstrated that MTB concentration can be determined through measuring the impedance of MTB suspensions in DI water. This new detection mechanism can be an alternative for current impedance methods available for detecting bacterial cells.  相似文献   

2.
Supported liquid membranes (SLMs), prepared by immobilising the room temperature ionic liquids (RTILs) [CnMIM]PF6 (n = 4 and 8) and [C10MIM]BF4 in a polyvinylidene (PVDF) supporting membrane, were prepared and characterised by electrochemical impedance spectroscopy (IS). This non-invasive technique allows the determination of the electrical properties of a given sample, such as the electrical resistance and capacitance under working conditions, i.e., in contact with saline solutions.

Bearing in mind that the water content of the ionic liquids can drastically affect their physicochemical properties, impedance measurements of the SLMs, placed between two aqueous solutions, were carried out at regular time intervals, in order to assess the impact of the presence of water inside the RTILs on the electrical properties of supported ionic liquid membranes. The electrical resistance of the SLMs and its variation during long-term operation was also used as a physical parameter to identify the presence/loss of ionic liquid from the pores of the support. Additionally, the comparison of the IS results obtained for the SLMs with those obtained for the supporting membrane was carried out, in order to gather information about electrical changes associated with the presence of ionic liquid in the pores.  相似文献   


3.
A MEMS‐based impedance biosensor was designed, fabricated, and tested to effectively detect the presence of bacterial cells including E. coli O157:H7 and Salmonella typhimurium in raw chicken products using detection region made of multiple interdigitated electrode arrays. A positive dielectrophoresis based focusing electrode was used in order to focus and concentrate the bacterial cells at the centerline of the fluidic microchannel and direct them toward the detection microchannel. The biosensor was fabricated using surface micromachining technology on a glass substrate. The results demonstrate that the device can detect Salmonella with concentrations as low as 10 cells/mL in less than 1 h. The device sensitivity was improved by the addition of the focusing electrodes, which increased the signal response by a factor between 6 and 18 times higher than without the use of the focusing electrodes. The biosensor is selective and can detect other types of pathogen by changing the type of the antibody immobilized on the detection electrodes. The device was able to differentiate live from dead bacteria.  相似文献   

4.
Composite polymeric electrolytes of PEO-LiClO4-Al2O3 and PEO-LiClO4-EC were prepared and the ionic conductivity by a.c. impedance was calculated using four different methods, and three kinds of representations of a.c. impedance spectra were adopted. The first is based on the Nyquist impedance plot of the imaginary part (Z″) versus the real part (Z′) of the complex impedance. The second and the third correspond to the plots of imaginary impedance Z″ as a function of frequency (f), and the absolute value (|Z|) and phase angle (θ) as a function of f, respectively. It was found that the values of the ionic conductivity calculated using the three representations of a.c. impedance spectra are basically identical. Electronic Publication  相似文献   

5.
Mass transfer phenomena in membrane fuel cells are complex and diversified because of the presence of complex transport pathways including porous media of very different pore sizes and possible formation of liquid water. Electrochemical impedance spectroscopy, although allowing valuable information on ohmic phenomena, charge transfer and mass transfer phenomena, may nevertheless appear insufficient below 1 Hz. Use of another variable, that is, back pressure, as an excitation variable for electrochemical pressure impedance spectroscopy is shown here a promising tool for investigations and diagnosis of fuel cells.  相似文献   

6.
Low-density protein microarrays are emerging tools in diagnostics whose deployment could be primarily limited by the cost of fluorescence detection schemes. This paper describes an electrical readout system of microarrays comprising an array of gold interdigitated microelectrodes and an array of polydimethylsiloxane microwells, which enabled multiplexed detection of up to thirty six biological events on the same substrate. Similarly to fluorescent readout counterparts, the microarray can be developed on disposable glass slide substrates. However, unlike them, the presented approach is compact and requires a simple and inexpensive instrumentation. The system makes use of urease labeled affinity reagents for developing the microarrays and is based on detection of conductivity changes taking place when ionic species are generated in solution due to the catalytic hydrolysis of urea. The use of a polydimethylsiloxane microwell array facilitates the positioning of the measurement solution on every spot of the microarray. Also, it ensures the liquid tightness and isolation from the surrounding ones during the microarray readout process, thereby avoiding evaporation and chemical cross-talk effects that were shown to affect the sensitivity and reliability of the system. The performance of the system is demonstrated by carrying out the readout of a microarray for boldenone anabolic androgenic steroid hormone. Analytical results are comparable to those obtained by fluorescent scanner detection approaches. The estimated detection limit is 4.0 ng mL−1, this being below the threshold value set by the World Anti-Doping Agency and the European Community.  相似文献   

7.
Xiao F  Zhang N  Gu H  Qian M  Bai J  Zhang W  Jin L 《Talanta》2011,84(1):204-211
Sudan I monoclonal antibodies (Mabs) were prepared by hybridoma technique and firstly used to develop a Sudan I immunosensor by immobilizing the Mabs on a gold electrode. o-Mercaptobenzoic acid (MBA) was covalently conjugated on the gold electrode to form a self-assembled monolayer (SAM). The immobilization of Sudan I Mabs to the SAM was carried out through a stable acyl amino ester intermediate generated by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydrosuccinimide (NHS), which could condense antibodies reproducibly and densely on the SAM. The changes of the electrode behavior after each assembly step were investigated by cyclic voltammetric (CV) technique. The Sudan I concentration was measured through the increase of impedance values in the corresponding specific binding of Sudan I and Sudan I antibody. A linear relationship between the increased electron-transfer resistance (Ret) and the logarithmic value of Sudan I concentrations was found in the range of 0.05-50 ng mL−1 with the detection limit of 0.03 ng mL−1. Using hot chili as a model sample, acceptable recovery of 96.5-107.3% was obtained. The results were validated by conventional HPLC method with good correlation. The proposed method was proven to be a feasible quantitative method for Sudan I analysis with the properties of stability, highly sensitivity and selectivity.  相似文献   

8.
A method for performing neutron radiography and locally resolved impedance spectroscopy simultaneously in situ in an operating polymer electrolyte fuel cell (PEFC) is presented. The new method provides concurrently spatially resolved information about the local cell performance, the locally limiting processes, and the liquid water distribution. Information about the impact of water on cell performance and limiting processes can be gained in situ on a local scale in an operating PEFC. The method was applied to a PEFC operated on pure H2/O2 in co-flow mode under low humidity operating conditions. The results show that in co-flow mode strong flooding and severe drying can occur at the very same time in different sections of a PEFC.  相似文献   

9.
A simple assay based on electrochemical impedance spectroscopy (EIS) for detection of telomerase activity is developed, and it is demonstrated that the label-free EIS method is capable of detecting the telomerase activity in HeLa cells with a detection limit of 1000 HeLa cells without using any amplification technique.  相似文献   

10.
A label-free sensing assay for ethanolamine (EA) detection based on G-quadruplex-EA binding interaction is presented by using G-rich aptamer DNA (Ap-DNA) and electrochemical impedance spectroscopy (EIS). The presence of K+ induces the Ap-DNA to form a K+-stabilized G-quadruplex structure which provides binding sites for EA. The sensing mechanism was further confirmed by circular dichroism (CD) spectroscopy and EIS measurement. As a result, the charge transfer resistance (RCT) is strongly increased as demonstrated by using the ferro/ferricyanide ([Fe(CN)6]3−/4−) as a redox probe. Under the optimized conditions, a linear relationship between ΔRCT and EA concentration was obtained over the range of 0.16 nM and 16 nM EA, with a detection limit of 0.08 nM. Interference by other selected chemicals with similar structure was negligible. Analytical results of EA spiked into tap water and serum by the sensor suggested the assay could be successfully applied to real sample analysis. With the advantages of high sensitivity, selectivity and simple sensor construction, this method is potentially suitable for the on-site monitoring of EA contamination.  相似文献   

11.
The detection and identification of dilute bacterial samples by surface-enhanced Raman spectroscopy has been explored by mixing aqueous suspensions of bacteria with a suspension of nanocolloidal silver particles. An estimate of the detection limit of E. coli was obtained by varying the concentration of bacteria. By correcting the Raman spectra for the broad librational OH band of water, reproducible spectra were obtained for E. coli concentrations as low as approximately 103 cfu/mL. To aid in the assignment of Raman bands, spectra for E. coli in D2O are also reported. Figure Light scattering apparatus used to detect bacteria  相似文献   

12.
Different isolated tomato fruit cuticular membranes (ripe and green tomato cuticles and the cutin of these membranes) were studied by impedance spectroscopy measurements when the membranes were in contact with NaCl solutions at different concentrations. Remarkable differences in the impedance plots and the equivalent circuits associated to each membrane sample were obtained: the ripe tomato cuticle and the cutin, only present a relaxation process, but for the green tomato cuticle two relaxation processes were obtained. Using the equivalent circuits as models, electrical and electrochemical parameters for each membrane were determined. These results permit us to assign the relaxation processes to the different components of the tomato membrane (polyester matrix, carbohydrates and pigments), obtaining in this way a detailed picture of the different environments of the plant interface. Variation with NaCl concentration for the different electrical parameters was also studied, and the electrical resistance of the biopolymer matrix was obtained.  相似文献   

13.
The use of electrochemical impedance spectroscopy for biosensing   总被引:1,自引:0,他引:1  
This review introduces the basic concepts and terms associated with impedance and techniques of measuring impedance. The focus of this review is on the application of this transduction method for sensing purposes. Examples of its use in combination with enzymes, antibodies, DNA and with cells will be described. Important fields of application include immune and nucleic acid analysis. Special attention is devoted to the various electrode design and amplification schemes developed for sensitivity enhancement. Electrolyte insulator semiconductor (EIS) structures will be treated separately. Figure An alternating current which is forced to pass an interface is sensitive to surface changes and will detect impedance changes due to biomolecule immobilisation or formation of a recognition complex. This can be used for the construction of biosensor electrodes  相似文献   

14.
We describe the experimental methods used in carrying out high resolution infrared spectroscopy of molecular beams using bolometric thermal detection. The main applications of this technique are also described and include: studies on molecular internal vibrational relaxation, radiationless transition after “visible” excitation, photodissociation spectroscopy of van der Waals molecules, the study of coherent excitation of molecules in the infrared, multiphoton infrared spectroscopy, overtone spectroscopy and the study of large molecular clusters.  相似文献   

15.
An electrochemical sensing system for oxytetracycline (OTC) detection was developed using ssDNA aptamer immobilized on gold interdigitated array (IDA) electrode chip. A highly specific ssDNA aptamer that bind to OTC with high affinity was employed to discriminate other tetracyclines (TCs), such as doxycycline (DOX) and tetracycline (TET). The immobilized thiol-modified aptamer on gold electrode chip served as a biorecognition element for the target molecules and the electrochemical signals generated from interactions between the aptamers and the target molecules was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV). The current decrease due to the interference of bound OTC, DOX or TET was analyzed with the electron flow produced by a redox reaction between ferro- and ferricyanide. The specificity of developed EC-biosensor for OTC was highly distinguishable from the structurally similar antibiotics (DOX and TET). The dynamic range was determined to be 1-100 nM of OTC concentration in semi-logarithmic coordinates.  相似文献   

16.
Chen Z  Li L  Zhao H  Guo L  Mu X 《Talanta》2011,83(5):4039-1506
A simple, highly sensitive, and label-free electrochemical impedance spectroscopy (EIS) aptasensor based on an anti-lysozyme-aptamer as a molecular recognition element, was developed for the detection of lysozyme. Improvement in sensitivity was achieved by utilizing gold nanoparticles (AuNPs), which were electrodeposited onto the surface of a gold electrode, as a platform for immobilization of the aptamer. To quantify the amount of lysozyme, changes in the interfacial electron transfer resistance (Ret) of the aptasensor were monitored using the redox couple of an [Fe(CN)6]3−/4− probe. The Ret increased with lysozyme concentration. The plot of Ret against the logarithm of lysozyme concentration is linear over the range from 0.1 pM to 500 pM with a detection limit of 0.01 pM. The aptasensor also showed good selectivity for lysozyme without being affected by the presence of other proteins.  相似文献   

17.
We have developed a specific compartment to increase the sensitivity of a routine FT-IR spectrometer. A high performance MCT detector has been included in the system. The SNR of the spectrometer has been improved by a factor of 10.  相似文献   

18.
食品污染是危害公众健康和安全的重要问题,探究灵敏、快速、简单的技术,以便在痕量水平上检测污染物,对保障食品质量安全和风险评价具有十分重要的意义.表面增强拉曼光谱(SERS)是利用光与金、银等纳米结构材料相互作用产生很强的表面等离子激元共振效应,可显著增强吸附在纳米结构表面上分子的拉曼信号,以超灵敏获取样品自身或拉曼探针...  相似文献   

19.
This work presents a microfluidic device, which was patterned with (i) microstructures for hydrodynamic capture of single particles and cells, and (ii) multiplexing microelectrodes for selective release via negative dielectrophoretic (nDEP) forces and electrical impedance measurements of immobilized samples. Computational fluid dynamics (CFD) simulations were performed to investigate the fluidic profiles within the microchannels during the hydrodynamic capture of particles and evaluate the performance of single‐cell immobilization. Results showed uniform distributions of velocities and pressure differences across all eight trapping sites. The hydrodynamic net force and the nDEP force acting on a 6 μm sphere were calculated in a 3D model. Polystyrene beads with difference diameters (6, 8, and 10 μm) and budding yeast cells were employed to verify multiple functions of the microfluidic device, including reliable capture and selective nDEP‐release of particles or cells and sensitive electrical impedance measurements of immobilized samples. The size of immobilized beads and the number of captured yeast cells can be discriminated by analyzing impedance signals at 1 MHz. Results also demonstrated that yeast cells can be immobilized at single‐cell resolution by combining the hydrodynamic capture with impedance measurements and nDEP‐release of unwanted samples. Therefore, the microfluidic device integrated with multiplexing microelectrodes potentially offers a versatile, reliable, and precise platform for single‐cell analysis.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号