1.
Two different approaches were used to improve the capabilities of solid sampling (SS) electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICP-OES) for the direct analysis of powdered rice. Firstly, a cooling step immediately before and after the vaporization step in the ETV temperature program resulted in a much sharper analyte signal peak. Secondly, point-by-point internal standardization with an Ar emission line significantly improved the linearity of calibration curves obtained with an increasing amount of rice flour certified reference material (CRM). Under the optimized conditions, detection limits ranged from 0.01 to 6 ng g−1 in the solid, depending on the element and wavelength selected. The method was validated through the quantitative analysis of corn bran and wheat flour CRMs. Application of the method to the multi-elemental analysis of 4-mg aliquots of real organic long grain rice (white and brown) also gave results for Al, As, Co, Cu, Fe, Mg, Se, Pb and Zn in agreement with those obtained by inductively coupled plasma mass spectrometry following acid digestion of 0.2-g aliquots. As the analysis takes roughly 5 min per sample (2.5 min for grinding, 0.5–1 min for weighing a 4-mg aliquot and 87 s for the ETV program), this approach shows great promise for fast screening of food samples.  相似文献   

2.
A novel method for the determination of trace elements in microliter samples using the tantalum filament electrothermal vaporization/low-pressure inductively coupled plasma (ETV/LP-ICP) atomic emission spectrometry has been developed. An improved tantalum filament ETV was directly coupled with LP-ICP system for efficient vaporization of microliter samples and further quantitative analysis. The experimental parameters including ETV current, rf power and mass flow rate of argon carrier gas were optimized using the copper emission signal produced by 5 μl of standard solution (5 μg/ml). Under the optimized condition, the analytical performances including linearity, precision and detection limit for the developed system were investigated. Absolute detection limits in the range of 22–391 pg for selected eight elements (Fe, Cu, Cr, Mn, Pb, K, Zn and Mg) were obtained with satisfactory precision (<8.9% RSD). The feasibility of the developed system has been demonstrated by analyzing wheat gluten NIST standard sample.  相似文献   

3.
Two digestion-free methods for trace analysis of boron nitride based on graphite furnace atomic absorption spectrometry (GFAAS) and electrothermal vaporization inductively coupled plasma spectrometry optical emission (ETV-ICP-OES) using direct solid sampling have been developed and applied to the determination of Al, Ca, Cr, Cu, Fe, Mg, Mn, Si, Ti and Zr in four boron nitride materials in concentration intervals of 1–23, 54–735, 0.05–21, 0.005–1.3, 1.6–112, 4.5–20, 0.03–1.8, 6–46, 38–170 and 0.4–2.3 μg g− 1, respectively. At optimized experimental conditions, with both methods, effective in-situ analyte/matrix separation was achieved and calibration could be performed using calibration curves measured with aqueous standard solutions. In solid sampling GFAAS, before sampling, the platform was covered with graphite powder and, for determination of Si, also the Pd/Mg(NO3)2 modifier was used. In the determination of all analyte elements by solid sampling ETV-ICP-OES, Freon R12 was added to argon carrier gas. For solid sampling GFAAS and ETV-ICP-OES, the achievable limits of detection were within 5 (Cu)–130 (Si) ng g− 1 and 8 (Cu)–200 (Si) ng g− 1, respectively. The results obtained by these two methods for four boron nitride materials of different purity grades are compared each with the other and with those obtained in analysis of digests by ICP-OES. The performance of the two solid sampling methods is compared and discussed.  相似文献   

4.
Pierre Masson 《Talanta》2007,71(3):1399-1404
The present work demonstrates the capability of electrothermal vaporization (ETV) to become an important tool of solid sample introduction in ICP-AES for plant sample analysis. Direct determination of Al, Ca, Fe, K, Mg, Mn, Na and Zn was investigated in powdered plant samples. Obtaining good results for major elements in plant samples was governed by some special operating conditions. The sensitivity of the method necessitated the use of ICP in radial view configuration. The behavior of elements during vaporization was studied between 500 and 2600 °C. External calibration was carried out using solid external (cellulose) spiked with aqueous standard solutions. However, performances of the analytical method were found dependent of argon flow rates. Analytical accuracy of the method was tested in three reference materials. Analytical results agreed with certified values when cellulose was used in calibration. However, K could not be determined because of excessive sensitivity. Without cellulose, it was found that Fe results were underestimated and Zn results overestimated. Relative standard deviations varied from 3 to 23%. Limits of detection varied from 1 to 80 ng g−1 from one element to the other for a typical mass sample of 2 mg.  相似文献   

5.
A new compact, aluminum electrothermal vaporization cell was constructed for inductively coupled plasma-optical emission spectrometry analysis. This cell is compact enough to fit within the space occupied by the spray chamber and fits directly to the quartz torch without extraneous tubing through the use of a simple Compression fitting. Sample volumes as low as 10 μL were analyzed with an automated control program for efficient vaporization. Twelve elements were analyzed utilizing a time resolved acquisition method so that real-time data could be generated over a period of 10 s with an average improvement factor of 14 for elements over a wavelength range of 193–445 nm.  相似文献   

6.
A method is developed for the direct determination of carbon in soft drinks by electrothermal vaporization inductively coupled plasma atomic emission spectrometry. A tungsten coil is used as the electrothermal vaporizer, and is extracted from a commercially produced 150 W, 15 V microscope bulb. The standard additions method is employed to correct any matrix effects from the samples. Carbon emission is monitored at 193.091 nm. Carbon content determined for the samples was in the range of 13 to 60 g in one 8 fl oz serving, and these values agreed with the label values in the range 93 to 137% (except for one sample, Orange Fanta, which provided a 200% recovery. This was likely due to non-carbohydrate carbon-containing species in that sample). The precision of the technique was always better than 20% relative standard deviation (n = 10). The detection limits for carbon range from 0.4 to 3 mg L− 1, and absolute detection limits range from 12 ng to 90 ng for a 30 μL aliquot of sample on the coil. This method could be an alternative approach for determining the carbon content of nonvolatile compounds, and complement HPLC–ICP-AES determination of those same species.  相似文献   

7.
A method has been developed for the determination of cobalt, copper and manganese in green coffee using direct solid sampling electrothermal atomic absorption spectrometry (SS-ET AAS). The motivation for the study was that only a few elements might be suitable to determine the origin of green coffee so that the multi-element techniques usually applied for this purpose might not be necessary. The three elements have been chosen as test elements as they were found to be significant in previous investigations. A number of botanical certified reference materials (CRM) and pre-analyzed samples of green coffee have been used for method validation, and inductively coupled plasma optical emission spectrometry (ICP OES) after microwave-assisted acid digestion of the samples as reference method. Calibration against aqueous standards could be used for the determination of Mn and Co by SS-ET AAS, but calibration against solid CRM was necessary for the determination of Cu. No significant difference was found between the results obtained with the proposed method and certified or independently determined values. The limits of detection for Mn, Cu and Co were 0.012, 0.006 and 0.004 μg g−1 using SS-ET AAS and 0.015, 0.13 and 0.10 μg g−1 using ICP OES. Seven samples of Brazilian green coffee have been analyzed, and there was no significant difference between the values obtained with SS-ET AAS and ICP OES for Mn and Cu. ICP OES could not be used as a reference method for Co, as essentially all values were below the limit of quantification of this technique.  相似文献   

8.
A new method for the direct analysis of coal using electrothermal vaporization inductively coupled plasma mass spectrometry and direct solid sample analysis was developed, aiming at the determination of Br and Cl. The procedure does not require any significant sample pretreatment and allows simultaneous determination of both elements to be carried out, requiring small mass aliquots of sample (about 0.5 mg). All operating parameters, including carrier gas flow-rate and RF power, were optimized for maximum sensitivity. The use of modifiers/aerosol carriers (Pd, Pd + Al and Pd + Ca) was evaluated, and the mixture of Pd and Ca was chosen, allowing pyrolysis and vaporization temperatures of 700 °C and 1900 °C, respectively. Chlorine was accurately determined using calibration against solid standards, whereas Br could also be determined using calibration against aqueous standard solutions. The limits of quantification were 0.03 μg g−1 for Br and 7 μg g−1 for Cl, and no spectral interferences were observed.  相似文献   

9.
Fly ash samples of cement works were analysed using slurry nebulization inductively coupled plasma atomic emission spectrometric (ICP-AES). Because of the influence of the experimental factors on the signal intensity, the optimal conditions of the analysis circumstances were determined. Control analyses (wet digestion followed by ICP-AES, and XRF of dry powders (pressed pellets)) were also carried out to compare the results. Based on the result, it was concluded that the slurry nebulization method using slurry standard of same type reference material for calibration can be applied for rapid but less precise (RSD 5–10%) determination of the elements in fly ash.  相似文献   

10.
Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) has been applied to determine Ga, Ge, As, Se and Sb in fly ash samples. The influences of instrument operating conditions and slurry preparation on the ion signals were reported. Pd and ascorbic acid were used as the mixed modifiers to enhance the ion signals. This method has been applied to determine Ga, Ge, As, Se and Sb in NIST SRM 1633a and 1633b coal fly ash reference materials and a fly ash sample collected locally. Since the sensitivities of the elements studied in slurry solution and aqueous solution were different slightly, analyte addition technique was used for the determination of Ga, Ge, As, Se and Sb in these samples. The As and Se analysis results of the reference materials agreed with the certified values. The results for which no certified value was available were also found to be in good agreement between the ETV-ICP-MS results and the reference values. The reference value was obtained by digesting the samples and analyzing the digested sample solutions by pneumatic nebulization Dynamic Reaction Cell™ (DRC) ICP-MS. The method detection limits estimated from analyte addition curves were about 0.23, 0.13, 0.17, 0.25 and 0.11 μg g−1 for Ga, Ge, As, Se and Sb, respectively, in original fly ash samples.  相似文献   

11.
Based on the formation of a volatile 1-(2′-pyridylazo)-2-naphthol (PAN) chelate, a novel method was described for the determination of trace ytterbium by electrothermal vaporization (ETV)-inductively coupled plasma atomic emission spectrometry (ICP-AES). It was found that in the presence of PAN, the trace Yb was quantitatively vaporized from a graphite furnace into ICP at a low temperature of 1100 °C. The main factors affecting the formation and vaporization of the Yb-PAN chelate were investigated in detail. Under the optimized conditions, the 3σ detection limit of Yb for this method was 0.4 ng ml−1 and the relative standard deviation (R.S.D.) for 0.1 μg ml−1 Yb was 3.7% (n=9, v=10 μl). The linear range of calibration spanned three orders of magnitude. The content of Yb in the standard reference material (shrub, GBW 07603) determined by the proposed method was in good agreement with the certified value.  相似文献   

12.
Ultrasonic slurry sampling electrothermal vaporization dynamic reaction cell inductively coupled plasma mass spectrometry (USS–ETV–DRC–ICP–MS) for the determination of Cr, Cd and Pb in several plastic samples, using NH4NO3 as the modifier, is described. The influences of the instrumental operating conditions and the slurry preparation technique on the ion signals are investigated. A reduction in the intensity of the background at signals corresponding to chromium masses (arising from matrix elements) was achieved by using NH3 as the reaction cell gas in the DRC. The method was applied to determine Cr, Cd and Pb in two polystyrene (PS) samples and a polyvinyl chloride (PVC) sample using two different calibration methods, namely standard addition and isotope dilution. The results were in good agreement with those for digested samples analyzed by ultrasonic nebulization DRC–ICP–MS. The precision between sample replicates was better than 17% with the USS–ETV–DRC–ICP–MS method. The method detection limits, estimated from standard addition curves, were about 6–9, 1–2 and 8–11 ng g−1 for Cr, Cd and Pb, respectively, in the original plastic samples.  相似文献   

13.
Inductively coupled plasma mass spectrometry coupled with ultrasonic slurry sampling electrothermal vaporization (USS-ETV-ICP-MS) has been applied to determine Pd, Rh, Pt and Au in 0.5% m/v slurries of several road dust samples. 2% m/v ammonium pyrrolidine dithiocarbamate (APDC) was used as the modifier to enhance the ion count. The influence of instrument operating conditions, slurry preparation and interferences on the ion count was reported. This method has been applied to the determination of Pd, Rh, Pt and Au in BCR 723 Road Dust and NIST SRM 2709 San Joaquin Soil reference materials and two road dust samples collected locally. The analysis results of the standard reference materials agreed with the certified values. Precision between sample replicates was better than 10% for all the determinations. The method detection limits estimated from standard addition curves were 0.9, 0.4, 0.6 and 0.4 ng g−1 for Pd, Rh, Pt and Au, respectively, in original dust samples.  相似文献   

14.
Arslan Z 《Talanta》2005,65(5):1326-1334
A method is developed for determination of trace elements, including Ag, As, Cd, Co, Cr, Cu, Mn, Ni, Se, Tl and Zn, in fish otoliths by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Hydrofluoric acid was used to precipitate calcium resulting from acid dissolution of otolith calcium carbonate. Initial acidity of the sample solution influenced the precipitation efficiency of calcium fluoride. Up to 99.5% of Ca was precipitated in solutions that contained less than 2% (v/v) HNO3. Recoveries of the elements obtained from spiked artificial otolith solutions were between 90 and 103%. Stabilization of the elements within the ETV cell was achieved with 0.3 μg Pd/0.2 μg Rh chemical modifier that also afforded optimum sensitivity for multielement determination. The method was validated by the analysis of a fish otolith reference material (CRM) of emperor snapper, and then applied to the determination of the trace elements in otoliths of several fish species captured in Raritan Bay, New Jersey. Results indicated that fish physiology and biological processes could influence the levels of Cu, Mn, Se and Zn in the otoliths of fish inhabiting a similar aqueous environment. Otolith concentrations of Cr and Ni did not show any significant differences among different species. Concentrations for Ag, As, Cd, Co and Tl were also not significantly different, but were very low indicating low affinity of otolith calcium carbonate to these elements.  相似文献   

15.
In this article, the advantages and the disadvantages of solid sampling-graphite-furnace-based methods are critically examined, taking into account the latest research. A discussion of the different situations for which these methods are best suited within analytical chemistry is presented, together with a general methodology intended to maximize their advantages. The topics discussed include achieving a selective atomization/vaporization of the analyte, calibration, the use of alternative working conditions, and data treatment as a function of the specific goals of the analysis. The purpose of the article is to offer a critical, but tutorial, evaluation of the possibilities of these methods, making it easier for new users to approach them and take advantage of their possibilities.  相似文献   

16.
Cadmium in the urine samples of patients with age-related disease forms a complex with a chelating agent, ammonium pyrrolidine dithio-carbamate, and the complex is extracted with methyl isobutyl ketone. One milliliter of urine provides three separate 200-μl aliquots of extract, so a preconcentration factor of 5/3 is observed. In this manner, the Cd is effectively separated from the complex urine matrix. An internal standard, Bi, is added to improve both precision and accuracy. The extracts are analyzed by inductively coupled plasma atomic emission spectrometry using a tungsten-coil as an electrothermal vaporizer. A 20-μl aliquot of the extract is injected directly onto the coil. Two Cd atomic emission lines are observed simultaneously: 228.8 nm and 226.5 nm. The limits of detection at these wavelengths are 0.04 and 0.2 μg/l, respectively. Without the extraction technique, the detection limit is 0.4 μg/l at the 228.8-nm line. With the internal standard technique, the accuracy as measured with a urine standard reference material is 98%. Six urine samples collected from patients with age-related diseases are found to contain Cd levels in the range 0.9 to 4.1 μg/l. The precision associated with the measurement of these real samples is 6.2% relative standard deviation. The technique provides off-wavelength background correction and simultaneous determination at two different wavelengths, so samples that are limited in volume can still be analyzed with a high degree of confidence.  相似文献   

17.
de Lima BB  Conte RA  Nunes CA 《Talanta》2003,59(1):89-93
Inductively coupled plasma optical emission spectrometry (ICP-OES) was applied to the analysis of major and minor elements of Ni-Nb alloys obtained by aluminothermic reduction process. Digestion of samples was made using a mixture of HF+HNO3. Minor and trace elements were determined without matrix separation. The precision for all constituents was <3%. Recoveries for the analyte-spiked samples were 95%.  相似文献   

18.
Elemental determinations are usually performed on plant samples for agronomic or environmental studies. Direct solid sampling is possible when electrothermal vaporization (ETV) is used as a method of sample introduction in inductively coupled plasma atomic emission spectrometry (ICP-AES). ETV-ICP-AES was applied for elemental determinations in plant samples. The first application aimed at Cd determinations in very small size plant material samples. Several reference plant materials were used to validate the accuracy of the method. Quality control included the systematic analysis of a reference sample in each batch of unknown samples. The performance of the method in time was illustrated by a control chart. The second application aimed at the content of Si in plant materials. Quantification of Si in plant samples was carried out using samples issued from an inter-laboratory test. Detection limit of 30 μg g− 1 was achieved for Si. In all cases, quantification was accomplished easily by means of aqueous standard solutions deposited on cellulose support.  相似文献   

19.
Slurry sampling electrothermal vaporization (ETV) inductively coupled plasma mass spectrometry (ICP-MS) has been applied to determine As and Se in soil and sludge samples. The influences of instrument operating conditions and slurry preparation on the ion signals were reported. Pd and ascorbic acid were used as mixed modifiers to enhance the ion signals. The effectiveness of ETV sample introduction technique for alleviating various spectral interferences in ICP-MS analysis has been demonstrated. This method has been applied to determine As and Se in NIST SRM 2709 San Joaquin soil reference material and NIST SRM 2781 domestic sludge reference material and a farmland soil sample collected locally. Since the sensitivities of As and Se in slurry solution and aqueous solution were different, analyte addition technique was used to determine As and Se in these samples. The As and Se analysis results of the reference materials agreed with the certified values. The precision between sample replicates was better than 5% for all determinations. The method detection limit estimated from analyte addition curves was about 0.03 and 0.02 μg g−1 for As and Se, respectively, in original soil and sludge samples.  相似文献   

20.
Uptake of trace elements into fish otoliths is governed by several factors such as life histories and environment in addition to stock and species differences. In an attempt to elucidate the elemental signatures of rare earth elements (REEs) in otoliths, a solid phase extraction (SPE) protocol was used in combination with electrothermal vaporization (ETV) as a sample introduction procedure for the determinations by inductively coupled plasma quadrupole mass spectrometry (ICP-MS). Effects of various parameters, such as carrier gas flow rate, atomization temperature and chemical modification, were examined for optimization of the conditions by ETV-ICP-MS. Atomization was achieved at 2800 °C. Lower temperatures (i.e. 2600 °C) resulted in severe memory problems due to incomplete atomization. Palladium was used as a chemical modifier. It was found that an increase in Pd concentration up to 0.5 μg in the injection volume (70 μl) led up to four-fold enhancement in the integrated signals. This phenomenon is attributed to the carrier effect of Pd rather than the stabilization since no significant losses were observed for high temperature drying around 700 °C even in the absence of Pd. Preconcentration was performed on-line at pH 5 by using a mini-column of Toyopearl AF-Chelate 650M chelating resin, which also eliminated the calcium matrix of otolith solutions. After preconcentration of 6.4 ml of solution, the concentrate was collected in 0.65 ml of 0.5% (v/v) HNO3 in autosampler cups, and then analyzed by ETV-ICP-MS. The method was validated with the analysis of a fish otolith certified reference material (CRM) of emperor snapper, and then applied to samples. Results obtained from otoliths of fish captured in the same habitat indicated that otolith rare earth element concentrations are more dependent on environmental conditions of the habitat than on species differences.  相似文献   