首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
This paper reports an analytical method for separating, identifying, and quantifying sulfur-containing compounds in crude oil fraction (IBP-360 degrees C) samples based on comprehensive two-dimensional gas chromatography coupled with a sulfur chemiluminescence detector. Various sulfur-containing compounds and their groups were analyzed with one direct injection. 3620 peaks were detected including 1722 thiols/thioethers/ disulfides/1-ring thiophenes, 953 benzothiophenes, 704 dibenzothiophenes, and 241 benzonaphthothiophenes. The target sulfur compounds and their groups were identified based on the group separation feature and structured retention of comprehensive two-dimensional gas chromatography as well as standard substances. The quantitative analysis of major sulfur-containing compounds and total sulfur was based on the linear response of the sulfur chemiluminescence detector using the internal standard method. The sulfur contents of target sulfur compounds and their groups in 4 crude oil fractions were also determined. The recoveries for standard sulfur-containing compounds were in the range of 90-102%. The quantitative result of total sulfur in the Oman crude oil fraction sample was compared with those from ASTM D 4294 standard method (total S by X-ray fluorescence spectrometry), the relative deviation (RD%) was 4.2% and the precision of the method satisfactory.  相似文献   

3.
The present investigation is focused on a simple flow modulator (FM), for comprehensive two-dimensional gas chromatography (GC×GC). The interface is stable at high temperatures, and consists of a metallic disc (located inside the GC oven) with seven ports, which are connected to an auxiliary pressure source via two branches, to the first and second dimension, to a waste branch (linked to a needle valve) and to an exchangeable modulation loop (2 ports). The ports are connected via micro-channels, etched on one of the inner surfaces of the disc. Modulation is achieved using a two-way electrovalve, connected on one side to the additional pressure source, and to the two metal branches, on the other. An FM enantio-GC×polar-GC method (using a flame ionization detector) was optimized (a 40-μL loop was employed), for the analysis of essential oils. As an example, an application on spearmint oil is shown; the method herein proposed was subjected to validation. Finally, an FM GC×GC diesel experiment was carried out, using an apolar-polar column combination, to demonstrate the effectiveness of the modulator in the analysis of a totally different sample-type.  相似文献   

4.
Multidimensional gas-chromatographical analysis of various tensides of natural or synthetic origin in cosmetic products is demonstrated. Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry allows the qualitative and quantitative determination of alkyl polyglucosides (AG), fatty alcohol ethoxylates (FAEO), fatty alcohol sulfates (FAS), fatty alcohol ether sulfates (FAES) and cocamidopropyl betaines (CAPB) in shower gel and cleaning agents. The samples were aliquoted in two parts. The first part was silylated, diluted and analysed; then, in order to detect anionic tensides (FAES, FAS) too, the second aliquot was hydrolysed before being silylated for analysis. Because of their amphoteric character, the betaines can only be analysed by gas chromatography after thermal decomposition in the injector, which leads to the corresponding amidoamines among other products.  相似文献   

5.
User-friendly and easy-to-use laboratory-written programs for visualisation and interpretation of comprehensive two-dimensional chromatographic data were developed. The programs that are not tied to any particular commercial instrument, and data obtained either by comprehensive two-dimensional liquid (LC × LC) or gas (GC × GC) chromatography can be analysed. Operations of the programs allow visualisation of 2D and 3D plots, comparison of two 2D plots at a time, as well as determination of retention times and peak heights and volumes.  相似文献   

6.
Many modulation systems in comprehensive 2D GC (GC×GC) are based on cryogenic methods. High trapping temperatures in these systems can result in ineffective trapping of the more volatile compounds, whilst temperatures that are too low can prevent efficient remobilisation of some compounds. To better understand the trapping and release of compounds over a wide range of volatilities, we have investigated a number of different constant temperature modulator settings, and have also examined a constant temperature differential between the cryo‐trap and the chromatographic oven. These investigations have led us to modify the temperature regulation capabilities of the longitudinally modulated cryogenic system (LMCS). In contrast to the current system, where the user sets a constant temperature for the cooling chamber, the user now sets the temperature difference between the cryo‐trap and the chromatographic oven. In this configuration, the cooling chamber temperature increases during the chromatographic run, tracking the oven temperature ramp. This produces more efficient, volatility‐dependent modulation, and increases the range of volatile compounds that can be analysed under optimal trap‐and‐release conditions within a single analytical run. This system also reduces cryogenic fluid consumption.  相似文献   

7.
A high-temperature ionic liquid, trihexyl(tetradecyl)phosphonium bis(trifluoromethane)sulfonamide, was used as the primary column stationary phase for comprehensive two-dimensional gas chromatography (GC × GC). The ionic liquid (IL) column was coupled to a 5% diphenyl/95% dimethyl polysiloxane (HP-5) secondary column. The retention characteristics of the IL column were compared to polyethylene glycol (DB-Wax) and 50% phenyl/50% methyl polysiloxane (HP-50+). A series of homologous compounds that included hydrocarbons, oxygenated organics, and halogenated alkanes were analyzed with each column combination. This comparison showed that the ionic liquid is less polar than DB-Wax but more polar than HP-50+. The most unique feature of the IL × HP-5 column combination is that alkanes, cyclic alkanes, and alkenes eluted in a narrow band in the GC × GC chromatogram; whereas, these compounds occupied a much larger portion of the DB-Wax × HP-5 and the HP-50+ × HP-5 chromatograms. Each column combination was used to analyze diesel fuel. The IL × HP-5 chromatogram displayed narrow bands for three major compound classes in diesel fuel: saturates, monoaromatics, and diaromatics. The IL column was used at temperatures as high as 290 °C for several months without any noticeable changes in column performance.  相似文献   

8.
Summary Headspace solid-phase micro-extraction (HS SPME), comprehensive two-dimensional GC (GC×GC), and flame ionization detection (FID) have been examined for their suitability and compatibility for rapid sampling, separation, and detection of garlic flavour volatiles. This approach (HS-SPME-GC×GC-FID) is distinctly superior to use of one-dimensional GC, i. e., HS-SPME-GC-FID. Direct comparison of the experimental results showed that a 10–50-fold increase in sensitivity is obtained, separating power is substantially enhanced, and the peak capacity is up to ten times higher. As a consequence, much more detailed flavour analysis can be performed; this results in better information about the aroma-active compounds.  相似文献   

9.
The modulator is the key point of comprehensive two-dimensional gas chromatography (GC×GC). This interface ensures the sampling and transfer of the sample from the first to the second dimension. Many systems based on different principles have been developed. However, to our knowledge, almost only cryogenic modulators are used in the petroleum industry. Nevertheless cryogenic fluids represent some disadvantages in term of safety, cost and time consuming. This paper reports a comparative study between differential flow and cryogenic liquid modulators for the detailed analysis of hydrocarbons in middle distillates type light cycle oil (LCO). Optimization of geometrical dimensions of a set of columns was carried out on the differential flow modulator system in order to reproduce the quality of separation of cryogenic modulation. Then a comparative study was investigated on sensibility and resolution (separation space and peak capacity) between the two systems.  相似文献   

10.
气相色谱近年的发展   总被引:1,自引:0,他引:1  
傅若农 《色谱》2009,27(5):584-591
简要阐述了近几年气相色谱(GC)的发展和特点。GC是一个成熟的技术,广泛地应用于各个领域,近几年GC的发展除了继续研究新的固定相和高性能的毛细管色谱柱之外,主要在全二维气相色谱(GC×GC)、快速GC、便携式GC仪和微型GC仪几个方面。近几年新研究的GC固定相主要集中在常温离子液体和各种环糊精的衍生物。现在GC研究者趋向于使用商品化的GC毛细管柱,而商品化的GC毛细管柱应用最多的是以含5%苯基的聚甲基硅氧烷为固定相的色谱柱。GC×GC发展迅猛,特别是关于调制器的研究,已开发出十多种调制模式,并广泛地应用于各个领域。为了适应大量样品的分析和现场分析,研究和开发了多种快速GC方法和仪器以及便携式GC仪。为了仪器的小型化和专属性检测,μGC仪的研究也稳步地发展起来。  相似文献   

11.
The separation characteristics of alkylchloroformate-derivatised amino acids (AAs) by using comprehensive two-dimensional gas chromatography (GC×GC) is reported. The use of a low-polarity/polar column set did not provide as good a separation performance as that achieved with a polar/non-polar column set, where the latter appeared to provide less correlation over the separation space. The degree of component correlation in each column set was estimated by using the correlation coefficient (r2; for 1tR and 2tR data) with the low-polarity/polar and polar/low-polarity sets returning correlation coefficients of 0.86, and 0.00 respectively, under the respective conditions employed for the experiments. The 1.5-m non-polar 2D column (0.1-mm ID; 0.1-m film thickness) gave peak halfwidths of the order of 50–80 ms. Linearity of detection was good, over a three order of magnitude concentration range, with typical lower detection limit of ca. 0.01 mg L–1, compared with 0.5 mg L–1 for normal GC operation with splitless injection. The method was demonstrated for analysis of AAs in a range of food and beverage products, including wine, beer and honey. The major AA in these samples was proline. The Heineken beer sample had a relatively more complex and more abundant AA content compared with the other beer sample. The wine and honey samples also gave a range of AA compounds. Repetition of the sample preparation/analysis procedure for the honey sample gave acceptable reproducibility for individual AAs.  相似文献   

12.
A laboratory-made cryogenic modulator for comprehensive two-dimensional gas chromatography (GCxGC) was constructed and evaluated. Analytes were trapped with carbon dioxide and desorbed with heated GC oven air. The GCxGC system included a non-polar first-dimension column and a semi-polar second-dimension column connected to a flame ionisation detector. A laboratory-written Matlab-based program was used for the data analysis. Peak widths at half height for n-alkanes, obtained with use of new modulator, were at narrowest 60 ms.  相似文献   

13.
Coal is a non renewable fossil fuel, used mainly as a source of electrical energy and in the production of coke. It is subjected to thermal treatment, pyrolysis, which produces coke as a main product, in addition to a condensed liquid by-product, called tar. Tar is a complex mixture of organic compounds which contains different chemical classes, presenting aromatic and sulphur heterocyclic compounds. In general, identification of these compounds requires steps of isolation and fractionation, mainly due to co-elution of these compounds with polyaromatic hydrocarbons (PAH). The objective of this work is to characterize the sulphur compounds present in the coal tar obtained via pyrolysis, using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry detector (GC×GC/TOFMS). Coal samples from the State of Paraná, Brazil were subjected to laboratorial scale pyrolysis. Several experimental conditions were tested, such as sample weight (5, 10 and 15g), heating ramp (10, 25 and 100°C/min) and final temperature (500, 700 and 900°C). Samples were analyzed by one dimensional gas chromatography (1D-GC) coupled to a quadrupole mass spectrometry detector (GC/qMS) and two-dimensional gas chromatography with time-of-flight mass spectrometry detector (GC×GC/TOFMS). The higher amount of sulphur compounds was obtained at a final temperature of 700°C and a heating ramp of 100°C/min. The main classes observed in the color plot were thiophenes, benzothiophenes and alkylated dibenzothiophenes. GC×GC/TOFMS allowed the identification of the greater number of compounds and the separation of several sulphur compounds from one another. Moreover, separation of sulphur compounds from polyaromatic hydrocarbons and phenols was achieved, which was not possible by 1D-GC. Comparing GC×GC/TOFMS and 1D-GC (SIM mode) also showed that 1D-GC, one of the most employed quantification tools for sulphur compounds, can be misleading for detection, identification and quantification, as the number of isomers of sulphur compounds found was greater than theoretically possible.  相似文献   

14.
The estimation of physicochemical parameters such as distillation points and relative densities still plays an important role in the quality control of gasoline and similar fuels. Their measurements according to standard ASTM procedures demands specific equipments and are time and work consuming. An alternative method to predict distillation points and relativity density by multivariate analysis of comprehensive two-dimensional gas chromatography with flame ionization detection (GC×GC-FID) data is presented here. Gasoline samples, previously tested according to standard methods, were used to build regression models, which were evaluated by external validation. The models for distillation points were built using variable selection methods, while the model for relativity density was built using the whole chromatograms. The root mean square prediction differences (RMSPD) obtained were 0.85%, 0.48%, 1.07% and 1.71% for 10, 50 and 90% v/v of distillation and for the final point of distillation, respectively. For relative density, the RMSPD was 0.24%. These results suggest that GC×GC-FID combined with multivariate analysis can be used to predict these physicochemical properties of gasoline.  相似文献   

15.
The analysis of organic biomarkers in chert samples offers key information about the environmental conditions in which these samples were formed, and this information can be used to track the lithic materials of many archaeological artifacts. Since the content of the organic fraction is very low and the complexity of the organic extracts is quite high, we have optimized the GC×GC separation of these mixtures. Making use of mixture of C(16)H(34)-C(44)H(90)n-alkane standards, a central composite design was carried out taking into account the carrier flow in the first and second columns, the modulation period and the discharge time. Regarding the measured responses, though the initially considered one was the peak volume, we have also evaluated the effects on the number of modulated peaks per analyte, the symmetry of the modulated peaks and the number of detected compounds. The final optimum conditions were defined as follows: a hydrogen flow of 1.2 mL/min in the first column and 18 mL/min in the second one, a modulation period of 1.4 s and a discharge time of 0.1 s and under these conditions all the response variables showed optimum values. Based on this optimized method several chert samples obtained from different stratigraphic levels in an ancient quarry were studied and we were able to distinguish them on the basis of the different constituents of organic biomarkers, such as mono-methylated alkanes, cyclic n-alkanes, branched alkanes, steranes and hopanes.  相似文献   

16.
Comprehensive two-dimensional gas chromatography (GC×GC) is a powerful technology for separating complex samples. The typical goal of GC×GC peak detection is to aggregate data points of analyte peaks based on their retention times and intensities. Two techniques commonly used for two-dimensional peak detection are the two-step algorithm and the watershed algorithm. A recent study [4] compared the performance of the two-step and watershed algorithms for GC×GC data with retention-time shifts in the second-column separations. In that analysis, the peak retention-time shifts were corrected while applying the two-step algorithm but the watershed algorithm was applied without shift correction. The results indicated that the watershed algorithm has a higher probability of erroneously splitting a single two-dimensional peak than the two-step approach. This paper reconsiders the analysis by comparing peak-detection performance for resolved peaks after correcting retention-time shifts for both the two-step and watershed algorithms. Simulations with wide-ranging conditions indicate that when shift correction is employed with both algorithms, the watershed algorithm detects resolved peaks with greater accuracy than the two-step method.  相似文献   

17.
18.
高儇博  常振阳  代威  童婷  张万峰  何生  朱书奎 《色谱》2014,32(10):1058-1065
对石油地质样品的化学组成进行全面准确的剖析,可以获得丰富的地球化学信息,为油气勘探工作提供科学依据。然而,该类样品除了组成复杂之外,还易受到各种物理(如蒸发、乳化、扩散、溶解和吸附)、化学(如光降解)和生物(如微生物降解)过程的影响。这些特点给样品的分析研究工作带来了极大的困难,传统的一维气相色谱/质谱技术很难对其进行理想的分离。全二维气相色谱(GC×GC)作为新发展起来的一种分离技术,在复杂样品分析方面具有独特的优势,虽然在石油地质样品分析中的应用相对较晚,但也日益受到关注。本文主要综述了近5年来GC×GC在石油地质方面国内外的研究进展以及存在的主要问题,并对今后的研究进行了展望。  相似文献   

19.
王楠  张艺  李响  童应鹏  孔宏伟  许国旺 《色谱》2010,28(4):329-335
建立了川芎挥发油的全二维气相色谱/飞行时间质谱(GC×GC/TOF MS)指纹图谱,并结合聚类分析评价了川芎药材的质量。4种萜类和苯酞类物质在DB-Petro×DB-17柱系统上实现了明显的族组分分离。从新都市的1个样品中分离出375种组分,其中相似度、反相似度皆大于800的化合物215个;根据质谱库检索和保留指数验证,或参照标准化合物及文献报道,从中定性了43个化合物。结合偏最小二乘法-判别分析,可以很好地将4个产区的挥发油样品加以区分,并找出20种差异最大的化合物,其中包括4种苯酞类物质。在此基础上,进一步应用正交偏最小二乘法,关联化学成分和抗氧化活性,结果发现,苯酞类物质(如藁本内酯、川芎内酯A和新蛇床内酯)对川芎挥发油样品地区差异的影响最大,其中彭州产川芎样品中苯酞类物质的含量最高。本文通过高分辨色谱技术研究了相邻产地的药物化学组成差异,并将化学指纹及生物学活性相关联,建立了系统的中药质量评价及活性化合物筛选研究模式。  相似文献   

20.
A new approach for target quantitative analysis for comprehensive two-dimensional gas chromatography (GC × GC), interval Multi-way Partial Least Square (iNPLS) is presented and evaluated in this paper. In iNPLS, the two-dimensional chromatogram is split in small sections; each of these pieces is treated as an independent new chromatogram. Separated conventional NPLS calibration models for the concentration of the target analyte are built for each of the pieces of the whole chromatogram, and the best model is selected for quantitative analysis. An algorithm for iNPLS running on MatLab platform was written, preliminarily evaluated with using solutions of model compounds with different chemical properties and subsequently applied to quantify some allergens in perfume samples. The results were found to be adequate, and good precision and accuracy was obtained even for poorly resolved peaks.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号