1.
A generalized preparation procedure of open tubular (OT) molecule imprinted polymer (MIP) columns is proposed for a number of templates with acidic functionality such as profen drugs and others. The template (S‐enantiomer) was mixed with methacrylic acid, ethylene glycol dimethacrylate and 4‐styrenesulfonic acid, dissolved in a porogen mixture of ACN/2‐propanol (9/1), and incubated in a pretreated and silanized fused silica capillary by the thermal non‐covalent polymerization procedure. The whole preparation procedure was exactly the same for all the MIP capillaries except for the selection of template. Nevertheless, the morphologies of the MIP layers were markedly variant depending upon the choice of template. The separation efficiency of each OT‐MIP column for chiral separation of R‐ and S‐enantiomers was examined and tuned to obtain the best separation efficiency by changing the chromatographic parameters such as eluent composition and pH. Different optimized conditions were obtained for different OT‐MIP columns. Nevertheless, a unified eluent could be used to obtain still quite satisfactory results. Non‐chiral separation of the MIP columns were also examined in the unified eluent with two sets of test mixtures, that is, a mixture of alkylbenzenes and a mixture of small polar solutes. The chiral and non‐chiral separation of this study resulted in very good separation efficiencies. This work is the very first study for the generalization of preparation of OT‐MIP columns for a number of templates.  相似文献   

2.
A monolithic molecularly imprinted polymer (MIP) column was prepared as the stationary phase for the capillary electrochromatographic (CEC) separation of a group of structurally related compounds including dopamine (DA), (±)-epinephrine (EP), (-)-isoproterenol (ISO), (±)-norepinephrine (NE), (±)-octopamine (OCT), and (±)-synephrine (SYN). Here, (-)-NE was used as the template. Either methacrylic acid (MAA) or itaconic acid (IA) together with a mixture of ethylene glycol dimethacrylate (EDMA) and α,α'-azobis(isobutyronitrile) (AIBN) in N,N-dimethylformamide (DMF) was introduced into a pre-treated, silanised, fused-silica capillary by a thermal non-covalent polymerisation procedure. Optimised conditions for the polymerisation reaction were assessed by the separation efficiency of the template. Both the template/monomer/cross linker molar ratio and the compositions of the functional monomer, cross-linker, and porogen affected polymerisation. The optimum in situ polymerisation reaction was performed at 65 °C for 17 min. By varying CEC parameters like eluent composition and pH, we observed that the addition of SDS to the eluent clearly improved the CEC separations. With a mobile phase of citrate buffer (10 mM, pH 3)/SDS (40 mM)/acetonitrile (2/2/1, v/v/v) solution and an applied voltage of 10 kV, the six related structures of the template and their enantiomeric mixtures were satisfactorily separated at 30 °C.  相似文献   

3.
Enhanced chiral separation performance has been observed for ketoprofen enantiomers in capillary electrochromatography (CEC) with an open-tubular (OT) column prepared with a specific molecule imprinted polymer (MIP) on the innerwall of 50mum ID capillary. The column was prepared by in situ thermal polymerization inside the pretreated and silanized fused silica capillary. A specific diluted monomer mixture composed of S-ketoprofen, methacrylic acid (MAA, functional monomer), ethylene glycol dimethacrylate (EDMA, cross-linker), and 4-styrenesulfonic acid (4-SSA) dissolved in 9/1 (v/v) acetonitrile/2-propanol was used to fabricate the OT-MIP layer. 4-SSA was added to form a MIP layer capable of stable and strong electro-osmotic flow (EOF) over the pH range of this study securing CEC elution of ketoprofen having partial negative charge near the optimized pH. Various parameters such as buffer pH, organic modifier composition, salt concentration, and applied potential have been optimized for CEC chiral separation of ketoprofen enantiomers. Very good separation selectivity and efficiency were observed, thus the chromatographic resolution of ketoprofen enantiomers was as high as 10.5, and the number of theoretical plates of R-ketoprofen, 156,000/m (40,000/m for S-ketoprofen), which proves that the OT-MIP-CEC type approach is a promising strategy in MIP study.  相似文献   

4.
Porous zirconia monolith (ZM) modified with cellulose 3,5-dimethylphenylcarbamate (CDMPC) was used as chiral stationary phase to separate basic chiral compounds in capillary electrochromatography. The electroosmotic flow behavior of bare and CDMPC-modified zirconia monolithic (CDMPC-ZM) column was studied in ACN/phosphate buffer eluents of pH ranging from 2 to 12. The CDMPC-ZM column was evaluated by investigating the influences of pH, the type and composition of organic modifier of the eluent on enantioseparation. CEC separations at pH 9 provided the best resolutions for the analytes studied, which are better than those observed on CDMPC-modified silica monolithic columns under similar chromatographic conditions. No appreciable decline in retention and resolution factors after over 200 injections, and run-to-run and day-to-day repeatabilities of the column of less than 3% indicate the stability of the zirconia monolithic column in basic media.  相似文献   

5.
The separation of chlorthalidone enantiomers in capillary electrochromatography on an achiral stationary phase when adding a chiral selector, hydroxypropyl-β-cyclodextrin, to the mobile phase, was optimised. The goal was to investigate the feasibility of modelling retention times and resolution when during the optimisation procedure regular replacement of columns is required due to their fragility. Therefore, it is essential that the packing procedure delivers reproducible columns. The optimisation of an existing chlorthalidone separation was chosen as case study. The influence of two factors, chiral selector concentration and organic modifier content, on the responses was modelled. The experiments performed prior to modelling were defined by a central composite design. Results on different columns, obtained under identical experimental conditions, were found comparable and thus modelling was possible in situations where several columns were required to complete a design. A second-order polynomial model was built for both responses. Optimal separations were also predicted using Derringer’s desirability functions. The optimum was found at 33 mM cyclodextrin and 16% (v/v) acetonitrile on two types of columns (with different packing times) leading to a strong reduction in analysis time for an equally good separation compared to the initial conditions. Measured and predicted responses were found comparable, indicating that acceptable models were obtained.  相似文献   

6.
《Electrophoresis》2017,38(8):1179-1187
This investigation demonstrates the application of a new peak sharpening technique to improve the separation of difficult‐to‐resolve racemic mixtures in capillary electro‐chromatography. Molecularly imprinted porous layer open tubular (MIP‐PLOT) capillaries, prepared by a layer‐on‐layer polymerization approach with Z‐l ‐Asp‐OH as the template, were selected to validate the approach. SEM revealed that the polymer film thickness can be varied by changes in both the polymer composition and the layer‐on‐layer regime. Capillaries made with methacrylic acid as the functional monomer could not separate the Z‐Asp‐OH racemate, due to weak interactions between the MIP‐PLOT material and the target analytes. In contrast, MIP‐PLOT capillaries prepared with 4‐vinylpyridine as the functional monomer resulted in increased ionic interactions with the target analytes. Separation of the enantiomers could be enhanced when a peak zone sharpening effect was exploited through the use of specific BGE compositions and by taking advantage of eigenpeak phenomena. In this manner, the position of a sharpening zone and the peak shape of the sample analytes could be fine‐tuned, so that when the sharpening zone and the target analyte co‐migrated the separation of the Z‐l ‐Asp‐OH enantiomer from its d ‐enantiomer in a racemic mixture could be achieved under overloading conditions.  相似文献   

7.
Currently, small proteins imprinting are more reported since large proteins molecular imprinting faces challenge due to their bulk size and complex structure. In this work, bovine serum albumin (BSA) surface-imprinted magnetic polymer was successfully synthesized based on atomic transfer radical polymerization (ATRP) method in the presence of common monomer (N-isopropylacrylamide) with the assistant of basic functional monomer (N-[3-(dimethylamino)propyl]-methacrylamide), which provides a achievable attempt for imprinting larger target proteins based on the ATPR with the mild reaction conditions. The BSA-imprinted polymer exhibited higher adsorption capacity and selectivity to BSA over the non-imprinted polymer. Competitive adsorption tests indicated the BSA-imprinted polymer had better selective adsorption and recognition properties to BSA in the mixture. The obtained BSA-imprinted polymer was applied to bovine serum, which also showed selectivity to BSA. In addition, a conventional aqueous two-phase solution of PEG/sulphate was used as elution for adsorbed BSA, which was compared with common NaCl elution.  相似文献   

8.
The influence on the enantiomeric resolution of the nature of the cationic BGE component (sodium, ammonium or potassium) and that of the anionic component (chloride, formate, methanesulfonate or camphorsulfonate) as well as the concentration of heptakis(2,3-di-O-methyl-6-O-sulfo)-beta-cyclodextrin (HDMS-beta-CD), the selected chiral selector, was studied in nonaqueous capillary electrophoresis (NACE). For this purpose, two D-optimal designs with 33 and 26 experimental points were applied. Three beta-blockers (atenolol, celiprolol and propranolol) and three local anesthetics (bupivacaine, mepivacaine and prilocaine) were selected as basic model compounds. Both cationic and anionic BGE components were found to have a deep impact on the enantiomeric resolution of the investigated analytes but it is the cationic component that has shown the strongest influence. Indeed, in some cases, the change of the latter led to a complete loss of enantioresolution. Based on the observed results, two NACE systems were recommended, namely ammonium formate and potassium camphorsulfonate in a methanolic solution containing HDMS-beta-CD and acidified with formic acid, in order to separate efficiently the enantiomers of basic drugs.  相似文献   

9.
A ligand with a terminal halogen (4‐chloromethylphenyl isocyanate) was chemically bound on the inner surface of pretreated silica capillary with 50 μm internal diameter and 58 cm total and 50 cm effective length in the presence of dibutyl tin dichloride as a catalyst through isocyanate‐hydroxyl reaction. Attachment of initiator (sodium diethyl dithiocarbamate) to the bound ligand was carried out and followed by in situ polymerization. Reversible addition‐fragmentation chain transfer polymerization was used for the immobilization of N‐phenylacrylamide‐styrene copolymer on the inner surface of capillary column. The resultant open tubular column showed excellent separation performance for derivatized saccharide isomers in capillary electrochromatography. d ‐Glucose was separated into α‐ and β‐anomers while five structural isomers were separated for derivatized maltotriose with separation efficiency above one million theoretical plates per meter. The effects of pH and acetonitrile composition on the electrochromatographic performance of the derivatized saccharides were studied and the optimized elution condition was found to be 90:10 v/v% acetonitrile/30 mM sodium acetate at pH 6.6. UV absorption at 214 nm was used as detection mode in open tubular capillary electrochromatography separations.  相似文献   

10.
A specially designed long open tubular capillary column (50 μm internal diameter and 112 cm effective length) was prepared by fabrication of a thin three‐component co‐polymer layer on the inner surface of silica capillary. A pretreated silica capillary was reacted with 4‐(chloromethyl)phenyl isocyanate in the presence of dibutyltin dichloride as catalyst followed by sodium diethyl dithiocarbamate. Then a thin polymer layer was made on the inner surface of capillary by reversible addition‐fragmentation transfer polymerization of styrene, N‐phenylacrylamide, and methacrylic acid. A carefully adjusted formulation of reaction mixture and elaborated procedures were adopted to secure formation of the co‐polymer layer of enhanced separation performance. The co‐polymer immobilized open tubular capillary column was used for the separation of a synthetic mixture of five peptides and excellent separation efficiency (over 1.7 million per column) was obtained in the capillary electrochromatography mode. Such excellent separation efficiencies of ca. 1 m column have not been obtained in the isocratic elution mode so far. The column was also used for separation of the peptides in the liquid chromatography mode to show very good separation efficiency (average 286 700 per column).  相似文献   

11.
The enantiomeric separation of 9‐fluorenylmethoxycarbonyl chloride (FMOC)‐homocysteine (Hcy) by CE was investigated using γ‐CD and the chiral ionic liquid (R)‐(1‐hydroxybutan‐2‐yl)(trimethyl)azanium‐bis(trifluoromethanesulfon)imidate (also called (R)‐N,N,N‐trimethyl‐2‐aminobutanol‐bis(trifluoromethane‐sulfon)imidate) (EtCholNTf2) as chiral selectors. Using 2 mM γ‐CD and 5 mM EtCholNTf2 in 50 mM borate buffer (pH 9), FMOC‐Hcy enantiomers were separated with a resolution value of 3.8. A reversal in the enantiomer migration order in comparison with the single use of γ‐CD in the separation buffer was obtained. Then, NMR experiments were carried out to elucidate the interactions taking place in the enantiomeric separation of FMOC‐Hcy. NMR analyses highlighted the formation of an inclusion complex since the hydrophobic group of FMOC‐Hcy was inserted into the γ‐CD cavity. Moreover, interactions between EtCholNTf2 and γ‐CD were also observed, suggesting that the chiral ionic liquid would also enter the cavity of the γ‐CD.  相似文献   