首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The analysis of variations in stable isotope composition is becoming an essential approach for evaluating enzymatic and abiotic reactions of organic contaminants in soils and aquatic systems. Different, sometimes complementary analytical techniques are currently used and developed to determine stable isotope ratios in individual organic compounds. Anticipating an increasing demand for compound-specific isotope analysis, this survey compiles information for choosing the most promising analytical approach to an isotope-related problem. To this end, we review the principles of instrumentation for compound-specific isotope analysis and show how they can be exploited to assess contaminant transformation processes. Using chlorinated solvents and triazine herbicides as illustrative examples, we discuss how the isotope-sensitive techniques impact the investigation of stable isotope fractionation in environmental chemistry and microbiology.  相似文献   

2.
Pitfalls in compound-specific isotope analysis of environmental samples   总被引:1,自引:0,他引:1  
In the last decade compound-specific stable isotope analysis (CSIA) has evolved as a valuable technique in the field of environmental science, especially in contaminated site assessment. Instrumentation and methods exist for highly precise measurements of the isotopic composition of organic contaminants even in a very low concentration range. Nevertheless, the determination of precise and accurate isotope data of environmental samples can be a challenge. Since CSIA is gaining more and more popularity in the assessment of in situ biodegradation of organic contaminants, an increasing number of authorities and environmental consulting offices are interested in the application of the method for contaminated site remediation. Because of this, it is important to demonstrate the problems and limitations associated with compound-specific isotope measurements of environmental samples. In this review, potential pitfalls of the analytical procedure are critically discussed and strategies to avoid possible sources of error are provided. In order to maintain the analytical quality and to ensure the basis for reliable stable isotope data, recommendations on groundwater sampling, and sample preservation and storage are given. Important aspects of sample preparation and preconcentration techniques to improve sensitivity are highlighted. Problems related to chromatographic resolution and matrix interference are discussed that have to be considered in order to achieve accurate gas chromatography/isotope ratio mass spectrometry measurements. As a result, the need for a thorough investigation of compound-specific isotope fractionation effects introduced by any step of the overall analytical method by standards with known isotopic composition is emphasized. Finally, we address some important points that have to be considered when interpreting data from field investigations. Figure CSIA Principal (Carbon)  相似文献   

3.
4.
Liu X  Bi X  Mai B  Sheng G  Fu J 《Talanta》2005,66(2):487-494
A method using a thin layer chromatography (TLC) for compound-specific stable carbon isotope analysis of polycyclic aromatic hydrocarbons (PAHs) with four to seven rings was developed in this study. Five aerosol samples were used as test samples. Two stationary phases and eight developing systems were tested. The results indicated: (1) silica gel is superior to aluminum oxide and the silica gel precoated plate developed with hexane:chloroform (45:5, v/v) can give the best separation effect; (2) individual PAHs associated with aerosols can be effectively separated from unresolved complex mixture (UCM) by this procedure. The carbon isotope composition of PAHs can be measured with a standard deviation (S.D.) < 0.5‰, n = 4. No significant isotopic fractionation was observed during the TLC procedure. And this technique can be used as a potential tool for source identification of PAHs in the aerosols.  相似文献   

5.
Compound-specific stable isotope analysis (CSIA) using gas chromatography-isotope ratio mass spectrometry (GC/IRMS) has developed into a mature analytical method in many application areas over the last decade. This is in particular true for carbon isotope analysis, whereas measurements of the other elements amenable to CSIA (hydrogen, nitrogen, oxygen) are much less routine. In environmental sciences, successful applications to date include (i) the allocation of contaminant sources on a local, regional, and global scale, (ii) the identification and quantification of (bio)transformation reactions on scales ranging from batch experiments to contaminated field sites, and (iii) the characterization of elementary reaction mechanisms that govern product formation. These three application areas are discussed in detail. The investigated spectrum of compounds comprises mainly n-alkanes, monoaromatics such as benzene and toluene, methyl tert-butyl ether (MTBE), polycyclic aromatic hydrocarbons (PAHs), and chlorinated hydrocarbons such as tetrachloromethane, trichloroethylene, and polychlorinated biphenyls (PCBs). Future research directions are primarily set by the state of the art in analytical instrumentation and method development. Approaches to utilize HPLC separation in CSIA, the enhancement of sensitivity of CSIA to allow field investigations in the µg L–1 range, and the development of methods for CSIA of other elements are reviewed. Furthermore, an alternative scheme to evaluate isotope data is outlined that would enable estimates of position-specific kinetic isotope effects and, thus, allow one to extract mechanistic chemical and biochemical information.Abbreviations BTEX benzene, toluene, ethylbenzene, xylenes - MTBE methyl tert-butyl ether - PAHs polycyclic aromatic hydrocarbons - VOCs volatile compounds - PCBs polychlorinated biphenyls - CSIA compound-specific (stable) isotope (ratio) analysis - GC-IRMS, GC/IRMS or GCIRMS gas chromatography-isotope ratio mass spectrometry - GC-C-IRMS, GC/C/IRMS or GCC-IRMS gas chromatography-combustion-isotope ratio mass spectrometry - irmGC/MS isotope ratio monitoring gas chromatograph-mass spectrometry - GC/P/IRMS gas chromatography-pyrolysis-isotope ratio mass spectrometry (used for D/H) - KIE kinetic isotope effect - PSIA position-specific isotope analysis (for intramolecular isotope distribution) - SNIF-NMR site-specific natural isotopic fractionation by nuclear magnetic resonance spectroscopy  相似文献   

6.
The performance of a gas chromatography-combustion-isotope ratio mass spectrometry system (GC-C-IRMS) with respect to the dependence of delta(13)C values on the amount of sample is presented. Particular attention is paid to the localization of the amount-dependent isotopic fractionation within the system. Injection experiments with varying amounts of gases (CO(2), n-hexane, and toluene) revealed that neither the detector unit nor the combustion reactor, but rather the conditions in the split/splitless injector, contributed to this effect. Although optimization of injector parameters was performed and a reduction of this adverse effect from 3 to 1 per thousand was achieved, it was not possible to eliminate isotopic fractionation completely. Consequently, additional injector parameters have to be considered and adjusted to achieve injection conditions free of fractionation. For routine analysis of the compound-specific delta(13)C analysis of different biomarkers in many environmental samples, perfect optimization may not always be reached. Therefore, in order to prevent systematic errors in the measured delta(13)C values due to different sample concentrations, it is suggested that correction for the remaining unknown amount-dependent fractionation can be made by means of co-analyzing standards of varying analyte concentrations and known delta(13)C values. Residual overall amount-dependent isotope-fractionation can thus be corrected mathematically.  相似文献   

7.
8.
Follow-up of stable isotope analysis of organic versus conventional milk   总被引:1,自引:0,他引:1  
Analysis of the stable isotope ratio of carbon (δ 13C) and α-linolenic acid (C18:3ω3) content in milk fat is a useful indicator of organic milk production. Referring to corresponding measurements, further analyses of stable isotope ratios were performed in 120 samples of conventionally and organically produced whole milk collected from German retailers during a period of 18 months. Conventional milk predominantly exhibited higher δ 15N values than organic milk, the latter of which never exceeded a maximum δ 15N threshold value of 5.50‰. Measurements of δ 34S did not differ significantly between organic and conventional milk. Because δ 13C, in general, is related to maize consumption, δ 13C in milk protein and δ 13C in milk fat were equally suited for authentication of organic milk. Thus, a high correlation (r = 0.99) was established between δ 13C in milk protein and lipids. Although occurring on different levels in organic and conventional milk, the relatively constant fractionation of carbon isotopes between protein and fat will allow for the advanced detection of adulteration in processed milk products, such as fraudulent combinations of organic milk fat and conventional skim milk. In addition to the strong correlation between C18:3ω3 and δ 13Cprotein (r = −0.91), a mutual dependence was identified between both δ 13Cprotein and δ 15N (r = 0.66) and C18:3ω3 and δ 15N (r = −0.61). Thus, multi-variable analyses are useful to increase robustness and reduce the number of exceptions in organic milk authentication. Future work involving multivariate statistical analysis can possibly further improve milk authentication in various respects including differentiating between brands of retail milk.  相似文献   

9.
Compound-specific isotope analysis (CSIA) has been established as a useful tool in the field of environmental science, in particular in the assessment of contaminated sites. What limits the use of gas chromatography/isotope ratio mass spectrometry (GC/IRMS) is the low sensitivity of the method compared with GC/MS analysis; however, the development of suitable extraction and enrichment techniques for important groundwater contaminants will extend the fields of application for GC/IRMS. So far, purge and trap (P&T) is the most effective, known preconcentration technique for on-line CSIA with the lowest reported method detection limits (MDLs in the low microg/L range). With the goal of improving the sensitivity of a fully automated GC/IRMS analysis method, a commercially available P&T system was modified. The method was evaluated for ten monoaromatic compounds (benzene, toluene, para-xylene, ethylbenzene, propylbenzene, isopropylbenzene, 1,2,3-trimethylbenzene, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene, fluorobenzene) and ten halogenated volatile organic compounds (VOCs) (dichloromethane, cis-1,2-dichloroethene, trans-1,2-dichloroethene, carbon tetrachloride, chloroform, 1,2-dichloroethane, trichloroethene, tetrachlorethene, 1,2-dibromoethane, bromoform). The influence of method parameters, including purge gas flow rates and purge times, on delta13C values of target compounds was evaluated. The P&T method showed good reproducibility, high linearity and small isotopic fractionation. MDLs were determined by consecutive calculation of the delta13C mean values. The last concentration for which the delta13C value was within this iterative interval and for which the standard deviation was lower than +/-0.5 per thousand for triplicate measurements was defined as the MDL. MDLs for monoaromatic compounds between 0.07 and 0.35 microg/L are the lowest values reported so far for continuous-flow isotope ratio measurements using an automated system. MDLs for halogenated hydrocarbons were between 0.76 and 27 microg/L. The environmental applicability of the P&T-GC/IRMS method in the low-microg/L range was demonstrated in a case study on groundwater samples from a former military air field contaminated with VOCs.  相似文献   

10.
Analysis of stable and radioactive isotopes from bone collagen provides useful information to archaeologists about the origin and age of bone artifacts. Isolation and analysis of single amino acids from the proteins can provide additional and more accurate information by removing contamination and separating a bulk isotope signal into its constituent parts. In this paper, we report a new method for the separation and isolation of underivatized amino acids from bone collagen, and their analysis by isotope ratio MS and accelerator MS. RP chromatography is used to separate the amino acids with nonpolar side chains, followed by an ion pair separation to isolate the remaining amino acids. The method produces single amino acids with little or no contamination from the separation process and allows for the measurement of accurate stable isotope ratios and pure samples for radiocarbon dating.  相似文献   

11.
Solid-state urea clathrate formation (SSUCF) as a chemical separation method prior to stable carbon isotope fingerprinting of diesel fuel contaminations was studied. The stable carbon isotope ratios (δ13C) of n-alkanes in diesel fuel can be used to trace the origin of a contamination. The accurate measurement of the stable isotopic composition of individual compounds requires baseline separation from any other co-eluting compounds. For this purpose silica gel column chromatography (SGCC) and SSUCF were applied. Detailed optimisation of SSUCF was performed: different activators, clathrate formation temperatures, activator volumes, clathrate formation times and sample capacity were investigated. The main benefits of the developed method are reduced clathrate formation time and increased recoveries for lower molecular weight n-alkanes. The recoveries of the developed SSUCF method ranged between 63 and 100% for C10–C24 n-alkanes with relative standard deviation no more than 7%. The precision of the gas chromatography-isotope ratio mass spectrometry measurement was acceptable with a standard deviation of the δ13C values ranging between 0.08 and 0.15‰. The absence of isotopic fractionation was also investigated.

The robustness of the method was tested within a model experiment. Nine different water samples including distilled water, tap water, river water, industrial wastewaters and groundwater samples were spiked with the same diesel fuel. The water samples were extracted with n-hexane and after purification with both SGCC and SSUCF n-alkanes were measured. The δ13C values of n-alkanes were found to be similar for all samples. The importance of sample purification prior to compound-specific isotope analysis (CSIA) was also demonstrated within this model experiment by analysing samples from different stages of the sample preparation.

Our results show that the proposed method can remarkably improve the precision of compound-specific stable carbon isotope analysis of n-alkanes originating from diesel contamination of the aquatic environment.  相似文献   


12.
Spreading sewage sludge on agricultural lands has been actively promoted by national authorities as an economic way of recycling. However, as by-product of wastewater treatment, sewage sludge may contain toxic substances, which could be incorporated into agricultural products or be distributed in the environment. Moreover, sediments can be contaminated by the discharge of wastewater effluents into rivers. This article reviews the determination of emerging contaminants (surfactants, flame retardants, pharmaceuticals and personal care products) in environmental solid samples (sludge, soil and sediment). Sample preparation, including extraction and clean-up, as well as the subsequent instrumental determination of contaminants are discussed. Recent applications of extraction techniques, such as Soxhlet extraction, ultrasound assisted extraction, pressurised liquid extraction, microwave assisted extraction and matrix solid-phase dispersion to the analysis of emerging contaminants in environmental solid samples are reviewed. Determination of these contaminants, generally carried out by gas chromatography and liquid chromatography coupled with different detectors, especially mass spectrometry for the identification and quantification of residues, is also summarised and discussed.   相似文献   

13.
A simple, quick and sensitive method for the compound-specific stable chlorine isotope analysis of chlorinated solvents by conventional quadrupole gas chromatography/mass spectrometry (GC/MS) is presented. With this method, compound-specific stable chlorine isotope ratios of typical chlorinated solvents like tetrachloroethene (PCE) and trichloroethene (TCE) can be determined quantitatively within 30 min by direct injection. The chlorine isotope ratios of target substances are calculated from the peak areas of several selected molecular ions and fragment ions of the substances, using a set of unique mathematical equations. The precision of the method was demonstrated through reproducibility tests. An internal precision of +/-0.4 per thousand to +/-1.1 per thousand was obtained when analyzing PCE and TCE in the 10-1000 pmol range. The validity of the method was further demonstrated by determining the chlorine isotopic fractionation factor during the reductive dechlorination of TCE in a batch experiment using zero-valent iron. The chlorine isotopic fractionation factor was calculated as 0.9976 +/- 0.0011 with a correlation coefficient of 0.9469 (n = 38). The high correlation coefficient indicates that compound-specific stable chlorine isotope analysis can be performed with sufficient accuracy using conventional quadrupole GC/MS when significant fractionation takes place during a reaction. For the first time, the chlorine isotope fractionation factor of TCE during an abiotic anaerobic dechlorination process was determined using quadrupole GC/MS, without offline sample preparation.  相似文献   

14.
A simple and effective method for the conversion of organic carbon into carbon dioxide for analysis of stable carbon isotopes (delta(13)C) in samples of various organic substances, soils, sedimentary rocks, oils and volatile organic liquids is presented. The conversion of organic carbon of the samples is carried out in a quartz reactor connected to a vacuum line for CO(2) freezing and purification. A solid organic sample mixed with CuO is placed at the reactor bottom and the reactor is subsequently filled with granular CuO. One end of the CuO column is preheated to 850 degrees C while the other end of the column in contact with the sample is kept at ambient temperature. Heating of the sample (850 degrees C) and the remainder of the column is then performed. The preheated part of the column provides efficient conversion of carbon into CO(2). The reactor for the conversion of volatile liquid organic compounds is filled with granular CuO. The column of CuO is heated to 850 degrees C. Samples of volatile liquids are introduced into the reactor through a septum using a microsyringe. Complete conversion takes 10 min for solid samples and 3 min for volatile liquids. The precision of the delta(13)C analysis for solid and volatile liquid organic substances is +/-0.1 per thousand and +/-0.04 per thousand, respectively.  相似文献   

15.
A novel method has been developed for compound-specific isotope analysis for acetone via DNPH (2,4-dinitrophenylhydrazine) derivatization together with combined gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Acetone reagents were used to assess delta13C fractionation during the DNPH derivatization process. Reduplicate delta13C analyses were designed to evaluate the reproducibility of the derivatization, with an average error (1 standard deviation) of 0.17 +/- 0.05 per thousand, and average analytical error of 0.28 +/- 0.09 per thousand. The derivatization process introduces no isotopic fractionation for acetone (the average difference between the predicted and analytical delta13C values was 0.09 +/- 0.20 per thousand, within the precision limits of the GC/C/IRMS measurements), which permits computation of the delta13C values for the original underivatized acetone through a mass balance equation. Together with further studies of the carbon isotopic effect during the atmospheric acetone-sampling procedure, it will be possible to use DNPH derivatization for carbon isotope analysis of atmospheric acetone.  相似文献   

16.
A new analytical method is presented for the compound-specific carbon and nitrogen isotope ratio analysis of a thermo-labile nitramine explosive hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by gas chromatograph coupled to an isotope ratio mass spectrometer (GC-IRMS). Two main approaches were used to minimise thermal decomposition of the compound during gas chromatographic separation: programmed temperature vaporisation (PTV) as an injection technique and a high-temperature ramp rate during the GC run. δ15N and δ13C values of RDX measured by GC-IRMS and elemental analyser (EA)-IRMS were in good agreement within a standard deviation of 0.3‰ and 0.4‰ for nitrogen and carbon, respectively. Application of the method for the isotope analysis of RDX during alkaline hydrolysis at 50°C revealed isotope fractionation factors ε carbon?=??7.8‰ and ε nitrogen?=??5.3‰.  相似文献   

17.
Off-line pyrolysis was used to liberate lignin moieties from dung and soil and, after trimethylsilylation, the delta(13)C values of these derivatives were determined by gas chromatography-combustion-isotope ratio mass spectrometry. Initial delta(13)C values determined for 4-vinylphenol, syringol, 4-vinylguaiacol, 4-acetylsyringol, 4-vinylsyringol, 4-(2-Z-propenyl)syringol, 4-(2-E-propenyl)syringol and 4-(2-propenone)syringol pyrolysis products of the lignin polyphenol structure from C(4) (delta(13)C(bulk) = -12.6%) and C(3) (delta(13)C(bulk) = -30.1 per thousand) dung confirmed the robust and reproducible nature of the off-line preparation technique. C(4) dung was used as a treatment in a randomised field experiment to assess the short-term sequestration of dung carbon in managed grasslands. Since lignin was on average 3.5 per thousand depleted in (13)C compared with bulk dung delta(13)C values, this may have resulted in an under-estimation of dung C incorporation based on bulk delta(13)C values. Therefore, an investigation of the compound-specific delta(13)C values of dung-derived lignin moieties extracted from soils sampled up to 372 days was undertaken. Delta(13)C values between lignin moieties extracted from treated and untreated soils showed that dung-derived lignin was not especially resistant to degradation and suggested that individual moieties of the lignin macromolecule must: (i) move into soil, (ii) be degraded, or (iii) be transformed diagenetically at different rates. This adds to a gathering body of evidence that lignin is not particularly stable in soils, which has considerable significance for the perceived role of different biochemical components in the cycling of C in soils.  相似文献   

18.
Compound-specific stable carbon isotope analysis by gas chromatography/combustion/isotope ratio mass spectrometry is an important method for the detection of steroid abuse in athletes. However, steroids in their natural form exhibit poor chromatographic resolution, while derivatization adds carbon thereby corrupting the starting stable isotopic composition. Hydropyrolysis is a new approach, which defunctionalizes steroids but leaves their carbon skeleton intact. The process improves chromatography, allowing the faithful measurement of carbon isotope ratios and enabling a more effective apportionment for the source of steroids and their metabolites.  相似文献   

19.
Chemical measurements often constitute the basis for informed decision-making at different levels in society; sound decision-making is possible only if the quality of the data used is uncompromised. To guarantee the reliability and comparability of analytical data an intricate system of quality-assurance measures has to be put into effect in a laboratory. Reference materials and, in particular, certified reference materials (CRMs) are essential for achieving traceability and comparability of measurement results between laboratories and over time. As in any other domain of analytical chemistry, techniques used to monitor the levels and fate of contaminants in the environment must be calibrated using appropriate calibration materials, and the methods must be properly validated using fit-for-purpose matrix-matched CRMs, to ensure confidence in the data produced. A sufficiently large number of matrix CRMs are available for analysis of most elements, and the group of chemicals known as persistent organic pollutants, in environmental compartments and biota. The wide variety of analyte/level/matrix/matrix property combinations available from several suppliers enables analysts to select CRMs which sufficiently match the properties of the samples they analyse routinely. Materials value-assigned for the so-called emerging pollutants are scarce at the moment, though an objective of current development programmes of CRM suppliers is to overcome this problem.  相似文献   

20.
Compound-specific stable carbon isotope analysis by gas chromatography/combustion/isotope ratio mass spectrometry is an effective and risk-free means of investigating fatty acid metabolism. Straightforward analysis, however, leads to poor chromatographic resolution, while derivatization adds carbon thereby corrupting the starting stable isotopic composition. Hydropyrolysis is a new approach which defunctionalizes fatty acids to yield the corresponding n-alkanes thus retaining the carbon skeleton intact and improving chromatography, allowing the faithful measurement of carbon isotope ratios.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号