首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Earlier liquid-chromatographic methods for the determination of gossypol, based on highly acidic methanolic solvents, provide broad tailing peaks. The use of acetonitrile with aqueous phosphoric acid/tri-n-butylammonium phosphate at pH 3.5 and a high-resolution radial-compression column gave greatly improved performance and excellent peak shape.  相似文献   

2.
An ultra high‐performance liquid chromatographic (UHPLC) system was developed and optimized for the separation of porphyrins of clinical interest. Optimum conditions for the simultaneous separation of uroporphyrin, hepta‐, hexa‐, penta‐carboxylic acid porphyrins and coproporphyrin and their type I and III isomers on a Thermo Hypersil BDS C18 column (2.4 µm particle size, 100 × 2.1 mm i.d.) using a gradient elution with 10% (v/v) acetonitrile in 1.0 m ammonium acetate buffer (pH 5.16) and 10% (v/v) acetonitrile in methanol at a flow‐rate of 0.4 mL/min. The effect of mobile phase buffer molarity on the sensitivity of fluorescence detection and resolution of porphyrin isomers was investigated. The method was successfully applied to the analysis of porphyrins extracted from the urine and faeces of patients with various human porphyrias. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
A new application for the quantitative and isotopic analyses of dissolved inorganic and dissolved organic carbon compounds has been developed. Dissolved organic matter (DOM) in natural water samples can be separated on a high-performance liquid chromatography (HPLC) column and collected as fractions. Each discrete fraction can then be analyzed using the technique of St-Jean (Rapid Commun. Mass Spectrom. 2003; 17: 419-428) with a total inorganic carbon/total organic carbon (TIC/TOC) analyzer interfaced with a continuous-flow isotope ratio mass spectrometer. Experimental data using short-chain fatty acid standards (formic, acetic, and propionic acids) show that fraction recoveries of 100% are possible and that sample integrity is maintained. 13C-isotopic analyses of products prior to and subsequent to extraction and collection show no isotopic effects associated with the methodology, and errors are well within the accepted analytical uncertainty of the IRMS. Comparison of data from pure standards and organic-rich natural waters shows that quantitative analyses still need to be done with standards that more closely imitate the matrices of the samples, in order to acquire an appropriate calibration curve. Injections of organic-rich matrices on the HPLC column did not affect fraction recovery, nor did they create high background of partially retained organic compounds slowly released from the HPLC column, and hence 13C-isotopic results are relatively unaffected. The specific limitation on this methodology is the required use of carbon-free carrier solvents due to potential memory effects associated with the TIC/TOC analyzer. Further developments of this application could make routine compound-specific isotopic analyses (CSIA) for a wider range of organic materials possible.  相似文献   

4.
This study reports on an improved method for acetaldehyde (ACH) determination in blood by high-performance liquid chromatography (HPLC). In the case of HPLC analysis, ACH is generally converted to derivatives for ultraviolet detection (for example 2,4-dinitrophenylhydrazine [DNPH] derivative). Nevertheless, elevation of the background during protein precipitation, hydrazone synthesis, or both frequently results in a serious loss of accuracy and precision of the analysis. The method in this study is developed to minimize the increase in nonspecific ACH-DNPH with a view to optimize mainly the synthetic condition of ACH-DNPH. The background is decreased dramatically by gentle deproteination, optimization of the DNPH amount and reaction pH, and reversed-phase solid extraction for the elimination of excess DNPH reagent. The standard curves show good linearity between 0 and 100 microM and minimal background is observed, indicating that the method is useful for monitoring the ACH concentration in blood.  相似文献   

5.
6.
Altered levels of aminothiols in biological fluids are thought to be an important risk indicator for several diseases, and reliable methods for the accurate determination of aminothiols concentrations in plasma are thus required. In this paper ammonium 5-bromo-7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (SBD-BF) is proposed as a convenient fluorogenic derivatizating reagent for the determination of aminothiols (cysteine, cysteinylglycine, homocysteine and glutathione) by HPLC with fluorescence detection. The reactions of SBD-BF with aminothiols at room temperature are about three-times faster than those of ammonium 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (the most frequently employed reagent) at 60 °C. The derivatives of SBD-BF with cysteine, cysteinylglycine, homocysteine and glutathione are easily separated by HPLC and their calibration curves show excellent linearity over the range 0.05–20 μmol/L with excellent r2 values for all analytes. SBD-BF reacts with thiols under mild conditions, i.e. at 25 °C over about 30 min, and is proposed as a suitable fluorogenic reagent for thiol derivatization to be introduced in analytical clinical chemistry. The detection limits of Cys, Cys-Gly, Hcy and GSH at a signal-to-noise ratio of 5 were 0.1 μM for Cys, 0.01 μM for Cys-Gly and Hcy, and 0.02 μM for GSH. Furthermore, validation parameters of the proposed method are quite satisfactory. As an application of this method the determination of thiol derivatives in human plasma was carried out on a number of samples.  相似文献   

7.
Summary Elevated plasma homocysteine is, a known risk factor in arteriosclerotic vascular disease. To measure homocysteine in a large number of samples, we have developed a rapid, simple, robust and inexpensive reversed-phase HPLC method for routine analysis. Mercaptopro-pionylglycine was used as the internal standard and an external calibration in plasma was performed. Improvement was achieved by the use of gradient elution (using a sodium acetate buffer and methanol) resulting in a higher number of samples analyzed per day. Plasma samples were reduced with tributylphosphine and the proteins were precipitated with perchloric acid before addition of internal standard. The analytes were derivatized by use of 7-fluorobenzofurazone-4-sulfonic acid ammonium salt. For calibration human plasma was spiked with nine different concentrations of homocysteine (range 2–50 μmol L−1). The inter-assay precision of replicate (n=29) analysis of the concentration of homocysteine in a sample of pooled plasma was 3.0%. The limit of detection, defined as three times the signal-to-noise ratio, was 0.25 μmol L−1. The linearity of the assay was confirmed for a plasma concentration range of 2–2000 μmol L−1. The variation of duplicate analyses of 842 plasma samples was 2.6±1.7%.  相似文献   

8.
9.
10.
A small, semi-preparative C(4) RP-HPLC column was used to set up the conclusive laboratory-scale purification of Chinese hamster ovary-derived human thyrotropin (hTSH), after a preliminary concentration-purification of an extremely dilute and poorly ( approximately 0.6 microg hTSH/mL; mass fraction=0.35%) conditioned medium on a cation exchanger. Several fractions of this eluate were repeatedly injected on the semi-preparative column, obtaining, in a single run (<1h chromatographic time), a concentrated pool ( approximately 1.2 mg/mL) of highly purified hTSH that could be further concentrated to >3 mg/mL and then efficiently lyophilized. The overall recovery in the rapid RP-HPLC purification step, including concentration and lyophilization, was of the order of 80%. The final product, when tested via a precise, single-dose in vivo bioassay, confirmed that it did not suffer any loss of bioactivity. This same methodology can be easily adapted to the small-scale purification of other recombinant products, even when obtained from genetically modified organisms at extremely low concentrations and mass fractions.  相似文献   

11.
12.
Stability constants of binary Fe(III)-methylcysteine, Cr(III)-methylcysteine and mixed Fe(III)-methylcysteine-cysteine, Cr(III)-methylcysteine-cysteine complexes have been determined by paper electrophoresis at 0.1 M ionic strength and a temperature of 35 degrees C. The stability constants of Fe(III)-methylcysteine-cysteine and Cr(III)-methylcysteine-cysteine mixed complexes were found to be 6.00 +/- 0.07 and 5.05 +/- 0.15 (logarithm of stability constant values), respectively.  相似文献   

13.
We used chromatography modeling software to assist in HPLC method development, with the goal of enhancing separations through the exclusive use of gradient time and column temperature. We surveyed nine stationary phases for their utility in pigment purification and natural sample analysis. For purification, a complex algal matrix was separated on an efficient monomeric column, from which partially purified fractions were collected and purified on polymeric columns that exaggerated resolution between pigments of interest. Additionally, we feature an HPLC method that is simple, fast, demonstrates excellent transferability and is ideal for quantitative analysis of pigments in dilute natural water samples.  相似文献   

14.
An adsorbent for the high-performance affinity chromatography of antisteroid antibodies was prepared, based on a commercial pre-packed column. The column contained activated microparticulate silica beads bearing epoxide functions, on which the steroid dexamethasone was covalently linked. The column was used successfully for the rapid and complete isolation of several hundred microgram amounts of specific antidexamethasone antibodies from rabbit antisera. The practical aspects of the purification procedure, especially the optimization of the washing and of the elution steps, are detailed. Despite non-biospecific elution with 20% acetonitrile in an acidic buffer, the purification yield was very satisfactory and the biological activity of the purified immunoglobulins appeared excellent.  相似文献   

15.
A reliable and simple method for the routine analysis of pharmaceutical dosage forms by high-performance liquid chromatography using a C18 Bondapak reversed-phase column with a binary solvent system consisting of acetonitrile and 0.05 M potassium dihydrogen phosphate has been developed. Standardised extraction procedures for drugs in various dosage forms have been developed and successfully applied to a wide range of current pharmaceutical formulations.  相似文献   

16.
17.
18.
N. Mellor 《Chromatographia》1982,16(1):359-363
Summary Many analysts are not taking full advantage of the high speed possibilities of modern LC. Some analytical procedures reported in the literature, and many in regular use in control laboratories, could be achieved in less time without loss in precision. Some factors which affect retention times are discussed and the advantages and disadvantages of employing shorter column lengths and finer packing materials in reversed-phase HPLC are examined. The effect on efficiency of increased flow rates with 10,5 and 3 m ODS materials is shown. The ability to couple shorter column lengths without loss of efficiency is also demonstrated. This allows a minimum length to be selected that gives adequate resolution. Examples of high speed separations are shown and limitations in state of the art HPLC equipment and chromatographic data systems are discussed briefly.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

19.
Cell membrane components have been increasingly recognized as important biochemicals in the fields of biochemistry and pharmacy due to their relationship with metabolite transport in the cells. Among the components, phosphatidylcholine (PC) is considered a valuable biochemical, because it is difficult to commercialize. PC demand has been largely increased in the fields of the nutrient, cosmetic and pharmacy industries, and so the development of a preparative chromatography process is critical to supply a low-cost PC. In this study, we investigated the HPLC separation of phospholipid originated from egg yolk, which contains 80% (w/w) PC and 15% (w/w) phosphatidylethanolamine. Column temperature, mobile phase composition and its flow-rate and kinds of stationary phase were varied to understand the effectiveness of PC separation. For studying the relationship between recovery yield and sample loading amount in HPLC, we performed overloading experiments. In this way, we successfully separated PC with over 99% purity and with 98% yield with the following HPLC operating conditions; pure methanol as a mobile phase, 2.0 ml/min flow-rate and 1000 mg/ml feed concentration in a KR-100-10SIL column.  相似文献   

20.
We describe a method for the rapid clean-up of rodent urine samples prior to the analysis of porphyrin carboxylic acids by reversed-phase high-performance liquid chromatography (HPLC) with fluorescence detection. A simple pretreatment step using chromatography on a Dowex 1X8 anion-exchange resin effectively removes fluorescent substances that are present in rodent urine and would otherwise interfere with the detection and quantitation of urinary porphyrins by HPLC. Recovery of porphyrins with four to eight carboxyl groups (coproporphyrin to uroporphyrin) averaged 93% using this procedure. The use of this method to determine the amount of individual porphyrins present in the urine of hexachlorobenzene-treated mice is illustrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号