首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Noncovalent interactions govern how molecules communicate. Mass spectrometry is an important and versatile tool for the analysis of noncovalent complexes (NCX). Electrospray mass spectrometry (ESI-MS) is the most widely used MS technique for the study of NCXs because of its softer ionization and easy compatibility with the solution phase of NCX mixtures. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has also been used to study NCXs. However, successful analysis depends upon several experimental factors, such as matrix selection, solution pH, and instrumental parameters. In this study, we employ MALDI imaging mass spectrometry to investigate the location and formation of NCXs, involving both peptides and proteins, in a MALDI sample spot.
Figure
?  相似文献   

2.
Conventional electrospray ionization mass spectrometry (ESI-MS) uses a capillary for sample loading and ionization. Along with the development of ambient ionization techniques, ESI-MS using noncapillary emitters has attracted more interest in recent years. Following our recent report on ESI-MS using wooden tips (Anal. Chem. 83, 8201–8207 (2011)), the technique was further investigated and extended in this study. Our results revealed that the wooden tips could serve as a chromatographic column for separation of sample components. Sequential and exhaustive ionization was observed for proteins and salts on wooden tips with salts ionized sooner and proteins later. Nonconductive materials that contain microchannels/pores could be used as tips for ESI-MS analysis with sample solutions loaded to the sharp-ends only, since rapid diffusion of sample solutions by capillary action would enable the tips to become conductive. Tips of inert materials such as bamboo, fabrics, and sponge could be used for sample loading and ionization, while samples such as tissue, mushroom, and bone could form tips to induce ionization for direct analysis with application of a high voltage.
Figure  相似文献   

3.
Two novel monofunctionalized fulleropyrrolidine derivatives (Prato adducts) were prepared and characterized by matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI). MALDI experiments conducted in the positive-ion mode on pure and mixed samples of both monofunctionalized fullerene derivatives revealed the efficient formation of bisadducts (in the case of the pure samples) and mixed bisadducts (in the case of a mixed sample). Bisadducts were not observed in the ESI experiments and thus not present in the sample. A mechanism for the MALDI formation of these bisadduct ions is proposed in which an azomethine ylide fragment is formed in situ from the monofunctionalized fulleropyrrolidine species upon laser irradiation. This fragment, which can survive as an intact moiety in the gas phase in the special environment provided by the MALDI experiment, is then able to attach to a fulleropyrrolidine monoadduct which acts as a dipolarophile, thus leading to the formation of a bisadduct fullerene derivative. The unprecedented re-attachment of the azomethine ylide implies that the establishment of the ligand attainment of Prato adducts based on MALDI analysis alone can lead to wrong assignments.
Figure
?  相似文献   

4.
The charge states of biomolecular ions in ESI-MS can be significantly increased by the addition of low-vapor supercharging (SC) reagents into the spraying solution. Despite the considerable interest from the community, the mechanistic aspects of SC are not well understood and are hotly debated. Arguments that denaturation accounts for the increased charging observed in proteins sprayed from aqueous solutions containing SC reagent have been published widely, but often with incomplete or ambiguous supporting data. In this work, we explored ESI MS charging and SC behavior of several biopolymers including proteins and DNA oligonucleotides. Analytes were ionized from 100 mM ammonium acetate (NH4Ac) aqueous buffer in both positive (ESI+) and negative (ESI–) ion modes. SC was induced either with m-NBA or by the elevated temperature of ESI capillary. For all the analytes studied we, found striking differences in the ESI MS response to these two modes of activation. The data suggest that activation with m-NBA results in more extensive analyte charging with lower degree of denaturation. When working solution with m-NBA was analyzed at elevated temperatures, the SC effect from m-NBA was neutralized. Instead, the net SC effect was similar to the SC effect achieved by thermal activation only. Overall, our observations indicate that SC reagents enhance ESI charging of biomolecules via distinctly different mechanism compared with the traditional approaches based on analyte denaturation. Instead, the data support the hypothesis that the SC phenomenon involves a direct interaction between a biopolymer and SC reagent occurring in evaporating ESI droplets.
Fig. a
?  相似文献   

5.
A series of studies comparing the performance of alternating current electrospray ionization (AC ESI) mass spectrometry (MS) and direct current electrospray ionization (DC ESI) MS have been conducted, exploring the absolute signal intensity and signal-to-background ratios produced by both methods using caffeine and a model peptide as targets. Because the high-voltage AC signal was more susceptible to generating gas discharges, the operating voltage range of AC ESI was significantly smaller than that for DC ESI, such that the absolute signal intensities produced by DC ESI at peak voltages were one to two orders of magnitude greater than those for AC ESI. Using an electronegative nebulizing gas, sulfur hexafluoride (SF6), instead of nitrogen (N2) increased the operating range of AC ESI by ~50 %, but did not appreciably improve signal intensities. While DC ESI generated far greater signal intensities, both ionization methods produced comparable signal-to-background noise, with AC ESI spectra appearing qualitatively cleaner. A quantitative calibration analysis was performed for two analytes, caffeine and the peptide MRFA. AC ESI utilizing SF6 outperforms all other techniques for the detection of MRFA, producing chromatographic limits of detection nearly one order of magnitude lower than that of DC ESI utilizing N2, and one-half that of DC ESI utilizing SF6. However, DC ESI outperforms AC ESI for the analysis of caffeine, indicating that improvements in spectral quality may benefit certain compounds or classes of compounds, on an individual basis.
Fig. a
?  相似文献   

6.
Electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo-ionization (APPI) are the most important techniques for the ionization of liquid samples. However, working under atmospheric pressure conditions, all these techniques involve some chemical rather than purely physical processes, and therefore, side reactions often yield to matrix-dependent ionization efficiencies. Here, a system is presented that combines both soft single-photon ionization (SPI) and hard 70 eV electron impact ionization (EI) of dissolved compounds under vacuum conditions. A quadrupole mass spectrometer was modified to enable direct EI, a technique developed by Cappiello et al. to obtain library-searchable EI mass spectra as well as soft SPI mass spectra of sample solutions. An electron beam-pumped rare gas excimer lamp working at 126 nm was used as well as a focusable vacuum UV light source for single-photon ionization. Both techniques, EI and SPI, were applied successfully for flow injection experiments providing library-matchable EI fragment mass spectra and soft SPI mass spectra, showing dominant signals for the molecular ion. Four model compounds were analyzed: hexadecane, propofol, chlorpropham, and eugenol, with detection limits in the picomolar range. This novel combination of EI and SPI promises great analytical benefits, thanks to the possibility of combining database alignment for EI data and molecular mass information provided by SPI. Possible applications for the presented ionization technology system are a matrix-effect-free detection and a rapid screening of different complex mixtures without time-consuming sample preparation or separation techniques (e.g., for analysis of reaction solutions in combinatorial chemistry) or a switchable hard (EI) and soft (SPI) MS method as detection step for liquid chromatography.
Figure
Scheme of the interface for introduction of liquid samples for vacuum photoionization/electron impact ionization MS  相似文献   

7.
Matrix assisted ionization of nonvolatile compounds is shown not to be limited to vacuum conditions and does not require a laser. Simply placing a solution of analyte dissolved with a suitable matrix such as 3-nitrobenzonitrile (3-NBN) or 2,5-dihydroxyacetophenone on a melting point tube and gently heating the dried sample near the ion entrance aperture of a mass spectrometer using a flow of gas produces abundant ions of peptides, small proteins, drugs, and polar lipids. Fundamental studies point to matrix-mediated ionization occurring prior to the entrance aperture of the mass spectrometer. The method is analytically useful, producing peptide mass fingerprints of bovine serum albumin tryptic digest consuming sub-picomoles of sample. Application of 100 fmol of angiotensin I in 3-NBN matrix produces the doubly and triply protonated molecular ions as the most abundant peaks in the mass spectrum. No carryover is observed for samples containing up to 100 pmol of this peptide. A commercial atmospheric samples analysis probe provides a simple method for sample introduction to an atmospheric pressure ion source for analysis of volatile and nonvolatile compounds without using the corona discharge but using sample preparation similar to matrix-assisted laser desorption/ionization.
Figure
?  相似文献   

8.
Measuring average quantities in complex mixtures can be challenging for mass spectrometry, as it requires ionization and detection with nearly equivalent cross-section for all components, minimal matrix effect, and suppressed signal from fragments and aggregates. Fragments and aggregates are particularly troublesome for complex mixtures, where they can be incorrectly assigned as parent ions. Here we study fragmentation and aggregation in six aromatic model compounds as well as petroleum asphaltenes (a naturally occurring complex mixture) using two laser-based ionization techniques: surface assisted laser desorption ionization (SALDI), in which a single laser desorbs and ionizes solid analytes; and laser ionization laser desorption mass spectrometry (L2MS), in which desorption and ionization are separated spatially and temporally with independent lasers. Model compounds studied include molecules commonly used as matrices in single laser ionization techniques such as matrix assisted laser desorption ionization (MALDI). We find significant fragmentation and aggregation in SALDI, such that individual fragment and aggregate peaks are typically more intense than the parent peak. These fragment and aggregate peaks are expected in MALDI experiments employing these compounds as matrices. On the other hand, we observe no aggregation and only minimal fragmentation in L2MS. These results highlight some advantages of L2MS for analysis of complex mixtures such as asphaltenes.
Figure
?  相似文献   

9.
Atmospheric ionization methods are ideally suited for prolonged MS/MS analysis. Data-independent MS/MS is a complementary technique for analysis of biological samples as compared to data-dependent analysis. Here, we pair data-independent MS/MS with the ambient ionization method nanospray desorption electrospray ionization (nanoDESI) for untargeted analysis of bacterial metabolites. Proof-of-principle data and analysis are illustrated by sampling Bacillus subtilis and Pseudomonas aeruginosa directly from Petri dishes. We found that this technique enables facile comparisons between strains via MS and MS/MS plots which can be translated to chemically informative molecular maps through MS/MS networking. The development of novel techniques to characterize microbial metabolites allows rapid and efficient analysis of metabolic exchange factors. This is motivated by our desire to develop novel techniques to explore the role of interspecies interactions in the environment, health, and disease. This is a contribution to honor Professor Catherine C. Fenselau in receiving the prestigious ASMS Award for a Distinguished Contribution in Mass Spectrometry for her pioneering work on microbial mass spectrometry.
Figure
?  相似文献   

10.
We have constructed an electrospray-assisted laser desorption/ionization (ELDI) source which utilizes a nitrogen laser pulse to desorb intact molecules from matrix-containing sample solution droplets, followed by electrospray ionization (ESI) post-ionization. The ELDI source is coupled to a quadrupole ion trap mass spectrometer and allows sampling under ambient conditions. Preliminary data showed that ELDI produces ESI-like multiply charged peptides and proteins up to 29 kDa carbonic anhydrase and 66 kDa bovine albumin from single-protein solutions, as well as from complex digest mixtures. The generated multiply charged polypeptides enable efficient tandem mass spectrometric (MS/MS)-based peptide sequencing. ELDI-MS/MS of protein digests and small intact proteins was performed both by collisionally activated dissociation (CAD) and by nozzle-skimmer dissociation (NSD). ELDI-MS/MS may be a useful tool for protein sequencing analysis and top-down proteomics study, and may complement matrix-assisted laser desorption/ionization (MALDI)-based measurements.  相似文献   

11.
The mechanisms whereby protein ions are liberated from charged droplets during electrospray ionization (ESI) remain under investigation. Compact conformers electrosprayed from aqueous solution in positive ion mode likely follow the charged residue model (CRM), which envisions analyte release after solvent evaporation to dryness. The concentration of nonvolatile salts such as NaCl increases sharply within vanishing CRM droplets, promoting nonspecific pairing of Cl- and Na+ with charged groups on the protein surface. For unfolded proteins, it has been proposed that ion formation occurs via the chain ejection model (CEM). During the CEM proteins are expelled from the droplet long before complete solvent evaporation has taken place. Here we examine whether salt adduction levels support the view that folded and unfolded proteins follow different ESI mechanisms. Solvent evaporation during the CEM is expected to be less extensive and, hence, the salt concentration at the point of protein release should be substantially lower than for the CRM. CEM ions should therefore exhibit lower adduction levels than CRM species. We explore the adduction behavior of several proteins that were chosen to allow comparative studies on folded and unfolded structures in the same solution. In-source activation eliminates chloride adducts via HCl release, generating protein ions that are heterogeneously charged because of sodiation and protonation. Sodiation levels measured under such conditions provide estimates of the salt adduction behavior experienced by the “nascent” analyte ions. Sodiation levels are significantly reduced for unfolded proteins, supporting the view that these species are indeed formed via the CEM.
Figure
?  相似文献   

12.
In this work, 53 selected pesticides of different chemical groups were extracted from Chinese herbal medicines and determined by ultra-high-performance liquid chromatography (UHPLC)–tandem mass spectrometry (MS/MS) using both electrospray ionization (ESI) and atmospheric-pressure chemical ionization (APCI). Extracts were obtained using the acetonitrile-based quick, easy, cheap, effective, rugged, and safe (QuEChERS) sample preparation technique. Cleanup was performed by dispersive solid-phase extraction using primary secondary amine, graphitized carbon black, and octadecylsilane. Two atmospheric-pressure interfaces, ESI and APCI, were checked and compared. The validation study, including detection limits, linearity, and matrix effects, was conducted on fritillaria, radix ginseng, folium isatidis, semen persicae, and flos lonicerae in multiple reaction monitoring mode. These matrices represent a variety of plants used in traditional Chinese medicine. Fritillaria and radix ginseng were chosen as representatives for roots, folium isatidis was chosen as a representative for leaves, semen persicae was chosen as a representative for seeds, and flos lonicerae was chosen as a representative for flowers. The limits of detection for pesticides were lower in the UHPLC–ESI-MS/MS method than in the UHPLC–APCI-MS/MS method. Matrix effects on the two ionizations were evaluated for the five matrices. Soft signal enhancement in UHPLC–APCI-MS/MS and signal suppression in UHPLC–ESI-MS/MS were observed.
Figure
Overview of UPLC–MS/MS assay for comparing the APCI and ESI interfaces  相似文献   

13.
We present plasma-assisted reaction chemical ionization (PARCI) for elemental analysis of halogens in organic compounds. Organohalogens are broken down to simple halogen-containing molecules (e.g., HBr) in a helium microwave-induced plasma followed by negative mode chemical ionization (CI) in the afterglow region. The reagent ions for CI originate from penning ionization of gases (e.g., N2) introduced into the afterglow region. The performance of PARCI-mass spectrometry (MS) is evaluated using flow injection analyses of organobromines, demonstrating 5–8 times better sensitivities compared with inductively coupled plasma MS. We show that compound-dependent sensitivities in PARCI-MS mainly arise from sample introduction biases.
Figure
?  相似文献   

14.
The detection and identification of proteins adsorbed onto biomaterial surfaces under ambient conditions has significant experimental advantages but has proven to be difficult to achieve with conventional measuring technologies. In this study, we present an adaptation of desorption electrospray ionization (DESI) and liquid extraction surface analysis (LESA) mass spectrometry (MS) coupled with in-situ surface tryptic digestion to identify protein species from a biomaterial surface. Cytochrome c, myoglobin, and BSA in a combination of single and mixture spots were printed in an array format onto Permanox slides, followed by in-situ surface digestion and detection via MS. Automated tandem MS performed on surface peptides was able to identify the proteins via MASCOT. Limits of detection were determined for DESI-MS and a comparison of DESI and LESA-MS peptide spectra characteristics and sensitivity was made. DESI-MS images of the arrays were produced and analyzed with imaging multivariate analysis to automatically separate peptide peaks for each of the proteins within a mixture into distinct components. This is the first time that DESI and LESA-MS have been used for the in-situ detection of surface digested proteins on biomaterial surfaces and presents a promising proof of concept for the use of ambient MS in the rapid and automated analysis of surface proteins.
Graphical abstract
?  相似文献   

15.
In this report, enzyme-coupled magnetic nanoparticles (EMPs) were shown to be an effective affinity-based tool for finding specific interactions between enzymatic targets and the low-mass molecules in complex mixtures using classic MALDI-TOF apparatus. EMPs used in this work act as nonorganic matrix enabling ionization of small molecules without any interference in the low-mass range (enzyme-coupled nanoparticles-assisted laser desorption ionization MS, ENALDI MS) and simultaneously carry the superficial specific binding sites to capture inhibitors present in a studied mixture. We evaluated ENALDI approach in two complementary variations: ‘ion fading’ (IF-ENALDI), based on superficial adsorption of inhibitors and ‘ion hunting’ (IH-ENALDI), based on selective pre-concentration of inhibitors. IF-ENALDI was applied for two sets of enzyme–inhibitor pairs: tyrosinase–glabridin and trypsin–leupeptin and for the real plant sample: Sparrmannia discolor leaf and stem methanol extract. The efficacy of IH-ENALDI was shown for the pair of trypsin–leupeptin. Both ENALDI approaches pose an alternative for bioassay-guided fractionation, the common method for finding inhibitors in the complex mixtures.
Figure
?  相似文献   

16.
In this study, we report on the development of a novel nebulizer configuration for sonic-spray ionization (SSI) mass spectrometry (MS), more specifically for a version of SSI that is referred to as Venturi easy ambient sonic-spray ionization (V-EASI) MS. The developed nebulizer configuration is based on a commercially available pneumatic glass nebulizer that has been used extensively for aerosol formation in atomic spectrometry. In the present study, the nebulizer was modified in order to achieve efficient V-EASI-MS operation. Upon evaluating this system, it has been demonstrated that V-EASI-MS offers some distinct advantages for the analysis of coordination compounds and redox active inorganic compounds over the predominantly used electrospray ionization (ESI) technique. Such advantages, for this type of compounds, are demonstrated here for the first time. More specifically, a series of labile heptanuclear heterometallic [CuII 6LnIII] clusters held together with artificial amino acid ligands, in addition to easily oxidized inorganic oxyanions of selenium and arsenic, were analyzed. The observed advantages pertain to V-EASI appearing to be a “milder” ionization source than ESI, not requiring electrical potentials for gas phase ion formation, thus eliminating the possibility of unwanted redox transformations, allowing for the “simultaneous” detection of negative and positive ions (bipolar analysis) without the need to change source ionization conditions, and also not requiring the use of syringes and delivery pumps. Because of such features, especially because of the absence of ionization potentials, EASI can be operated with minimal requirements for source parameter optimization. We observed that source temperature and accelerating voltage do not seem to affect labile compounds to the extent they do in ESI-MS. In addition, bipolar analysis of proteins was demonstrated here by acquiring both positive and negative ion mass spectra from the same protein solutions, without the need to independently adjust solution and source conditions in each mode. Finally, the simple and efficient operation of a dual-nebulizer configuration was demonstrated for V-EASI-MS for the first time.
Figure
?  相似文献   

17.
Many diseases such as arthritis or atherosclerosis are accompanied by inflammatory processes. Inflammation is characterized by the infiltration of cells such as neutrophilic granulocytes and (a) the release of phospholipases [particularly phospholipase A2 (PLA2)] and (b) the generation of reactive oxygen as well as nitrogen species (ROS and RNS). While PLA2 leads to defined lyso products (lacking one acyl residue), lipid oxidation is characterized by much more complex product patterns, including lipid peroxides, aldehydes (by double bond cleavage), and many others. Nevertheless, oxidation processes are highly important under in vivo conditions because molecules with regulatory functions are generated by the oxidation of lipids and/or free fatty acids. Therefore, lipid oxidation products as well as lysolipids are increasingly assumed to represent important disease (bio)markers. Consequently, there is also increasing interest in methods to characterize these products qualitatively and quantitatively. Mass spectrometry (MS) seems to be the method of choice to study (phospho)lipids changed under inflammatory conditions: nowadays, soft ionization MS methods are regularly used to study oxidative lipid modifications because of their high sensitivities and the tremendous mass resolutions that are achievable by using modern mass spectrometers. However, experimental care is required to be able to detect all relevant products. Although electrospray ionization (ESI) MS is so far most popular, applications of matrix-assisted laser desorption and ionization (MALDI) MS are continuously increasing. This review aims to summarize the so far available data on MS analyses of oxidized lipids as well as lysolipids. In addition to model systems, special attention will be paid to the monitoring of oxidized lipids and lysolipids under in vivo conditions. It is the aim of this review to provide a critical survey of the advantages and drawbacks of the different MS methods, with the focus on MALDI and ESI.
Figure
Scheme of mass spectrometric analysis to study oxidation and enzyme-modified phospholipids changed under inflammatory conditions  相似文献   

18.
Direct inject electrospray mass spectrometry offers minimal sample preparation and a “shotgun” approach to analyzing samples. However, complex matrix effects often make direct inject an undesirable sample introduction technique, particularly for trace level analytes. Highlighted here is our solution to the pitfalls of direct inject mass spectrometry and other ambient ionization methods with a focus on trace explosives. Direct analyte-probed nanoextraction coupled to nanospray ionization mass spectrometry solves selectivity issues and reduces matrix effects while maintaining minimal sample preparation requirements. With appropriate solvent conditions, most explosive residues can be analyzed with this technique regardless of the nature of the substance (i.e., nitroaromatic, oxidizing salt, or peroxide).
Figure
?  相似文献   

19.
The mass spectrometric behavior of symmetrically disubstituted 4,4′-bipyridinium salts under electron ionization (EI), electrospray ionization (ESI), direct analysis in real time (DART) ionization, and matrix-assisted laser desorption-ionization (MALDI) has been investigated. Electron ionization spectra were recorded using the direct injection of the probe at elevated temperature, when the salts were decomposed with the loss of counter-ions. In the case of ESI, primary ions are radical cations [Cat] and cations [Cat-H]+, decomposed further by the loss of N-substituents. More complicated DART spectra revealed the peaks characterizing both bipyridyl group and organic substituents. MALDI spectra were rather simple and contained the peaks for [Cat]+ · ions that are structurally identical to radical cations formed during the reduction of the salts in solution. Among all the methods, DART and MALDI are suitable for the qualitative analysis of such bis-quaternary salts, while ESI is convenient for the quantitative analysis of these analytes.  相似文献   

20.
Electrospray ionization (ESI) using wooden tips as solid substrates allows direct ionization of various samples and their simple and efficient analyses by mass spectrometry (MS). In this study, wooden-tip ESI-MS was used for pharmaceutical analysis. A wide variety of active components present in pharmaceuticals with forms of tablets, capsules, granules, dry suspensions, suspensions, drops, and oral liquids, etc., were all successfully ionized directly for mass spectrometric analysis. Trace degradation products were also sensitively detected using wooden-tip ESI-MS. This strategy was extended to construct chemical fingerprints of herbal products containing complex and unknown components, and the fingerprints provided valuable information for their quality assessment and origin tracing. Our experimental data demonstrated that wooden-tip ESI-MS is a useful tool for rapid pharmaceutical analysis, with high sensitivity and wide applicability, showing promising perspectives for quality assessment and control, authentication, and origin tracing of pharmaceuticals.
Figure
?  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号