首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Yazhen Wang 《Mikrochimica acta》2011,172(3-4):419-424
The electrochemistry of uric acid at a gold electrode modified with a self-assembled film of L-cysteine was studied by cyclic voltammetry and differential pulse voltammetry. Compared to the bare gold electrode, uric acid showed better electrochemical response in that the anodic peak current is stronger and the peak potential is negatively shifted by about 100 mV. The effects of experimental conditions on the oxidation of uric acid were tested and a calibration plot was established. The differential pulse response to uric acid is linear in the concentration range from 1.0?×?10?6 to ~?1.0?×?10?4 mol?L?1 (r?=?0.9995) and from 1.0?×?10?4 to ~?5.0?×?10?4 mol?L?1 (r?=?0.9990), the detection limit being 1.0?×?10?7 mol?L?1 (at S/N?=?3). The high sensitivity and good selectivity of the electrode was demonstrated by its practical application to the determination of uric acid in urine samples.
Cyclic voltammograms of UA at the bare electrode (a,b) and the L-Cys/Au electrode (c,d,e) in HAc-NaAc buffer containing different concentrations of UA. (a,c): blank; (b, d): 2.0?×?10?5 mol?L?1; (e) 4.0?×?10?5 mol?L?1. Scan rate: 100 mV?s?1  相似文献   

2.
A new electrode was developed by one-step potentiostatic electrodeposition (at ?2.0 V for 20 s) of Au/SiO2 nanoparticles on a glassy carbon electrode. The resulting electrode (nano-Au/SiO2/GCE) was characterized by scanning electronic microscopy, X-ray photoelectron spectroscopy and electrochemical techniques. The electrochemical behavior of dihydronicotinamide adenine dinucleotide (NADH) at the nano-Au/SiO2/GCE were thoroughly investigated. Compared to the unmodified electrode, the overpotential decreased by about 300 mV, and the current response significantly increased. These changes indicated that the modified electrode showed excellent catalytic activity in the oxidation of NADH. A linear relationship was obtained in the NADH concentration range from 1.0?×?10?6 to 1.0?×?10?4 mol?L?1. In addition, amperometric sensing of ethanol at the nano-Au/SiO2/GCE in combination with alcohol dehydrogenase and nicotinamide adenine dinucleotide was successfully demonstrated. A wide linear response was also found for ethanol in the range from 5.0?×?10?5 to 1.0?×?10?3 mol?L?1 and 1.0?×?10?3 to 1.0?×?10?2 mol?L?1, respectively. The method was successfully applied to determine ethanol in beer and biological samples.  相似文献   

3.
For the first time an in situ plated bismuth film electrode has been applied to catalytic adsorptive stripping voltammetry of cobalt in the presence of nitrite. At optimised conditions bismuth film was plated before each measurement for 30 s at ?1.0 V from a sample solution with the added supporting electrolyte and Bi(III) in the form of its complex with tartrate. The calibration graph for Co(II) for an accumulation time of 120 s was linear from 5×10?10 to 1×10?8 mol L?1. The detection limit was 1.1×10?10 mol L?1. The proposed procedure was applied for Co(II) determination in certified water reference material.  相似文献   

4.
A novel kind of carbon paste electrode (CPE) was prepared by mixing graphite powder, liquid paraffin and the ionic liquid 1-ethyl-3-methylimidazolium ethylsulfate. The resulting electrode was used for the simultaneous determination of guanosine and adenosine by differential pulse voltammetry. Compared to a conventional CPE, the oxidation peak currents are largely increased, and the oxidation peak potentials are negatively shifted. The electrochemical responses to guanosine and adenosine were investigated. Under optimized conditions, the calibration curves are linear in the concentration range from 1.0?×?10-6?mol?L-1 to 1.6?×?10-4?mol?L-1 for guanosine, and from 1.0?×?10-6?mol?L-1 to 2.7?×?10-4?mol?L-1 for adenosine at pH 3.5. Substances potentially interfering in the biological matrix do no interfere. The method was successfully applied to detect adenosine and guanosine in human urine without sample treatments.
Figure
Cyclic voltammograms on CPE (a) and CILE (b) for 1.0?×?10-4?mol?L-1 adenosine and 1.0?×?10-4?mol?L-1guanosine in a pH 3.5 B-R buffer solution at the scan rate of 100?mV?s-1. Inset was the typical differential pulse voltammograms of 1.0?×?10-4?mol?L-1 adenosine and 1.0?×?10-4?mol?L-1?L guanosine on CILE  相似文献   

5.
《Analytical letters》2012,45(15):2794-2804
Abstract

The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately ?1.26 V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 × 10?8 and 2.7 × 10?6 mol L?1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 × 10?9 mol L?1 and 3.3 × 10?8 mol L?1, respectively.

Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 × 10?6 to 1.0 × 10?5 mol L?1, with an LOD of 2.4 × 10?7 mol L?1 and an LOQ of 8.0 × 10?7 mol L?1. A sample rate of 50 injections per hour was achieved.

Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.  相似文献   

6.
A bare glassy carbon electrode is applied to nickel determination by adsorptive stripping voltammetry in the presence of dimethylglyoxime as a complexing agent. A procedure of nickel determination and electrode regeneration was proposed. The calibration graph for Ni(II) for an accumulation time of 120?s was linear from 2?×?10?9 to 1?×?10?7?mol?L?1. The detection limit was 8.2?×?10?10?mol?L?1. The relative standard deviation for a solution containing 2?×?10?8?mol?L?1 of Ni(II) was 4.1%. The proposed procedure was applied for Ni(II) determination in certified water reference materials.  相似文献   

7.
This paper reports the use of an adsorptive voltammetric technique for Pb(II) determination using cupferron as a selective complexing agent. After accumulation of the complex onto a hanging mercury drop electrode, the electrode potential was scanned with differential pulse modulation and the reduction current of lead was observed at about??0.5?V. Under optimum conditions (5?×?10?4?mol?L?1 cupferron concentration, 0.1?mol?L?1 acetate buffer (pH 5.5), adsorption at??50?mV for 30?s) the detection limit was 5.1?×?10?10?mol?L?1. The relative standard deviation of five measurements for low lead concentration was 3.1%. The accuracy of the method was tested by analysing certified reference material (SPS-WW1 Waste Water). Finally, the method was successfully applied to the determination of Pb(II) in river water samples without any pretreatments.  相似文献   

8.
The use of a robust tyrosinase biosensor, fabricated from graphite–Teflon rigid electrode matrices modified with gold nanoparticles, for the estimation of the total phenols content in olive oil mill wastewaters (OMW), is proposed. The performance of this bioelectrode using both continuous stirring and flow-injection amperometry was studied. A potential value of ?0.10?V was selected for the sensitive and stable detection of various phenolic compounds present in OMW samples: catechol, 3,4-dihydroxycinnamic acid (caffeic acid), 3,4-dihydroxyphenylacetic acid (DOPAC), 4-hydroxyphenylacetic acid, 4-hydroxyphenylethanol (tyrosol), and 4-hydroxyphenylpropionic acid. Using catechol as the target phenol, linear calibration graphs were obtained in the 1.0?×?10?8???8.0?×?10?6?mol?L?1 (batch) and 1.0?×?10?7???1.0?×?10?5?mol?L?1 (FI) concentration ranges, with slope values of 750?mA?L?mol?1 and 103?mA?L?mol?1, respectively. Batch amperometry was chosen for the analysis of real samples because of its higher sensitivity. For example, the limit of detection for caffeic acid was 80?nM. The ‘pool’ of phenolic compounds was estimated in OMW obtained from different extraction systems and containing phenols at diverse levels of concentration. A comparison of these results with those obtained by applying the Folin–Ciocalteau spectrophotometric reference method was carried out.  相似文献   

9.
《Electroanalysis》2006,18(15):1457-1462
This work describes an electroanalytical method for determining gold(I) thiomalate, aurothiomalate, widely used for treatment of reumatoid arthiritis, using a screen‐printed carbon electrode (SPCE). Aurothiomalate (AuTM) was determined indirectly at the same electrode by accumulating it first at ?1.5 V vs. printed carbon. At this potential in the adsorbed state, the AuTM is reduced to Au(0), which is then oxidized at two steps at ?0.22 V and +0.54 V on SPCE. Using optimized conditions of 60 s deposition time, ?1.5 V (vs. printed carbon) accumulation potential, 100 mV s?1 scan rate, linear calibration graphs can be obtained by monitoring the peak at +0.54 V for AuTM in HCl 0.1 mol L?1 from 1.43×10?6 to 1.55×10?4 mol L?1. A limit of detection obtained was 6.50×10?7 mol L?1, and the relative standard deviation from five measurements of 3.0×10?5 mol L?1 AuTM is 4.5%. The method was successfully applied for AuTM determination in human urine sample.  相似文献   

10.
The present work describes the individual, selective and simultaneous quantification of acetaminophen (ACP) and tramadol hydrochloride (TRA) using a modification‐free boron‐doped diamond (BDD) electrode. Cyclic voltammetric measurements revealed that the profile of the binary mixtures of ACP and TRA were manifested by two irreversible oxidation peaks at about +1.04 V (for ACP) and +1.61 V (for TRA) in Britton‐Robinson (BR) buffer pH 3.0. TRA oxidation peak was significantly improved in the presence of anionic surfactant, sodium dodecyl sulfate (SDS), while ACP signal did not change. By employing square‐wave stripping mode in BR buffer pH 3.0 containing 8×10?4 mol L?1 SDS after 30 s accumulation under open‐circuit voltage, the BDD electrode could be used for quantification of ACP and TRA simultaneously in the ranges 1.0–70 μg mL?1 (6.6×10?6–4.6×10?4 mol L?1) and 1.0–70 μg mL?1 (3.3×10?6–2.3×10?4 mol L?1), with detection limits of 0.11 μg mL?1 (7.3×10?7 mol L?1) and 0.13 μg mL?1 (4.3×10?7 mol L?1), respectively. The practical applicability of the proposed approach was tested for the individual and simultaneous quantification of ACP and/or TRA in the pharmaceutical dosage forms.  相似文献   

11.
《Electroanalysis》2003,15(22):1751-1755
A sensitive, selective and economic stripping voltammetry is described for the determination of trace amounts of zirconium at a morin‐modified carbon paste electrode (morin‐MCPE). Zirconium(IV) can be preconcentrated on the surface of the morin‐MCPE due to forming the Zr(IV)–morin complex. The complex produces two second‐order derivative anodic peaks at 0.69 V (vs. SCE) and 0.75 V when linear‐scanning from 0.0 to 1.0 V. The optimum analytical conditions are: 2.2 mol L?1 HCl, 0.0 V accummulation potential, 90 s accummulation time, 250 mV s?1 scan rate. A linear relationships between the peak currents at 0.75 V and the Zr(IV) concentration are in the range of 2.0×10?8 to 3.0×10?6 mol L?1. The detection limit is 1.0×10?8 mol L?1 (S/N=3) for 120 s accumulation. The RSD for determination of 4.0×10?7 mol L?1 Zr(IV) is 4.8% (n=8). The proposed method has been applied to determine zirconium in ore samples, unnecessarily extracted.  相似文献   

12.
Electrochemical behavior of dopamine (DA) was investigated at the gold nanoparticles self‐assembled glassy carbon electrode (GNP/LC/GCE), which was fabricated by self‐assembling gold nanoparticles on the surface of L ‐cysteine (LC) modified glassy carbon electrode (GCE) via successive cyclic voltammetry (CV). A pair of well‐defined redox peaks of DA on the GNP/LC/GCE was obtained at Epa=0.197 V and Epc=0.146 V, respectively. And the peak separation between DA and AA is about 0.2 V, which is enough for simultaneous determination of DA and AA. The peak currents of DA and AA were proportional with their concentrations in the range of 6.0×10?8–8.5×10?5 mol L?1 and 1.0×10?6–2.5×10?3 mol L?1, with the detection limit of 2.0×10?8 mol L?1 and 3.0×10?7 mol L?1 (S/N=3), respectively. The modified electrode exhibits an excellent reproducibility, sensibility and stability for simultaneous determination of DA and AA in human serum with satisfactory result.  相似文献   

13.
The highly boron‐doped diamond electrode (HBDD) combined with square wave voltammetry (SWV) was used in the development of an analytical procedure for diquat determination in potato and sugar cane samples and lemon, orange, tangerine and pineapple juices. Preliminary experiments realised in a medium of 0.05 mol L?1 Na2B4O7 showed the presence of two voltammetric peaks around ?0.6 V and around ?1.0 V vs. Ag/AgCl/Cl? 3.0 mol L?1, where the first peak could be successfully used for analytical proposes due the facility in the electrode surface renovation. After the experimental and voltammetric optimisation, the calculated detection and quantification limits were 1.6×10?10 mol L?1 and 5.3×10?10 mol L?1 (0.057 µg L?1 and 0.192 µg L?1, respectively), which are lower than the maximum residue limit established for fresh food samples by the Brazilian Sanitary Vigilance Agency. The proposed methodology was used to determine diquat residues in potato and sugar cane samples and lemon, orange, tangerine and pineapple juices and the calculated recovery efficiencies indicated that the proposed procedure presents higher robustness, stability and sensitivity, good reproducibility, and is very adequate for diquat determination in complex samples.  相似文献   

14.
Blasticidin S (BS) was determined in spiked rice samples by square wave voltammetry (SWV) and square wave stripping voltammetry (SWSV) using a cyclic renewable silver amalgam film electrode (Hg(Ag)FE). It was found that the compound can act as an electrocatalyst. In Britton? Robinson buffer at pH 7.0 a signal connected with the hydrogen evolution reaction was detected at ?1.2 V versus Ag/AgCl. Validation of the method was carried out. The detection and quantification limits were found to be 2.13×10?8 mol L?1; 7.10×10?8 mol L?1 for SWV and 2.65×10?9 mol L?1; 8.85×10?9 mol L?1 for SWSV, respectively.  相似文献   

15.
The electrochemical response of a modified-carbon nanotubes paste electrode with p-aminophenol was investigated as an electrochemical sensor for sulfite determination. The electrochemical behaviour of sulfite was studied at the surface of the modified electrode in aqueous media using cyclic voltammetry and square wave voltammetry. It has been found that under the optimum condition (pH 7.0) in cyclic voltammetry, the oxidation of sulfite occurs at a potential about 680?mV less positive than that of an unmodified-carbon nanotubes paste electrode. Under the optimized conditions, the electrocatalytic peak current showed linear relationship with sulfite concentration in the range of 2.0?×?10?7–2.8?×?10?4?mol?L?1 with a detection limit of 9.0?×?10?8?mol?L?1 sulfite. The relative standard deviations for ten successive assays of 1.0 and 50.0?µmol?L?1 sulfite were 2.5% and 2.1%, respectively. Finally, the modified electrode was examined as a selective, simple and precise new electrochemical sensor for the determination of sulfite in water and wastewater samples.  相似文献   

16.
《Electroanalysis》2006,18(1):70-76
A lead‐copper film electrode was proposed for Co(II) determination by catalytic adsorptive stripping voltammetry. The electrode was plated in situ and hence the exchange of a solution after plating step was not required. At optimized conditions the calibration graph for Co(II) was linear from 5×10?10 to 2×10?8 mol L?1 for accumulation time of 15 s. The relative standard deviation for Co(II) determination at concentration 5×10?9 mol L?1 was 4.1%. The detection limits for Co(II) were 1.2×10?10 and 1.0×10?11 mol L?1 for an accumulation time of 15 and 180 s, respectively. The method was applied to Co(II) determination in certified reference material and other water samples.  相似文献   

17.
An electrochemical biosensor was fabricated by covalent modification of 5-hydroxytryptophan (5-HTP) on the surface of glassy carbon electrode (GCE). The electrode, denoted as 5-HTP/GCE, was characterized by X-ray photoelectron spectroscopy, cyclic voltammetry and differential pulse voltammetry. For comparison, tryptophan modified GCE (TRP/GCE) and serotonin modified GCE (5-HT/GCE) were prepared by the same method. It was found that electrocatalytic ability of these electrodes was in the order of 5-HTP/GCE?>?TRP/GCE?>?5-HT/GCE for the oxidation of dopamine (DA) and 5-HT. The sensor was effective to simultaneously determine DA and 5-HT in a mixture. It can resolve the overlapping anodic peaks into two well-defined voltammetric peaks at 0.24 and 0.39 V (versus SCE). The linear response is in the range of 5.0?×?10?7–3.5?×?10?5 mol L?1 with a detection limit of 3.1?×?10?7 mol L?1 for DA, and in the range of 5.0?×?10?6–3.5?×?10?5 mol L?1 with a detection limit of 1.7?×?10?6 mol L?1 for 5-HT (s/n?=?3), respectively.  相似文献   

18.
Carbon paste electrode modified with Carboxymethyl chitosan-graft-poly(1-cyanoethanoyl-4-acryloyl-thiosemcarbazide)copolymers(CMCS-PCEATS) as ionophore was constructed for potentiometric determination of aluminum (III) and the chelation between the ionophore and the aluminum (III) ions at the electrode surface was characterized using SEM, EDX, and IR analysis. Thermal stability of the prepared electrode before and after chelation with the metal ion was investigated. The highest performance was obtained with the electrode modified with 10 mg of the prepared copolymers plasticized with TCP (electrode I). Under the optimized provision, the electrode I shows Nernstian slope of 19.9?±?0.36 mV decade??1 over the concentration range from 1.0?×?10??6 to 1.0?×?10??2 mol L??1 with a detection limit of 1.0?×?10??6 mol L??1 and pH ranges from 3 to 8. The paste is enough stable for 37 days without any detected change in the potential. The proposed method is more potent in determination of Al(III) in both real water and pharmaceutical samples potentiometrically. The results obtained agreed with those obtained with spectrophotometer and inductive coupled plasma (ICP).  相似文献   

19.
Several problems for the direct electrochemical oxidation of reduced glutathione (GSH) challenge the usage of electroanalytical techniques for its determination. In this work, the electrochemical oxidation of GSH catalyzed by gold nanoparticles electrodeposited on Nafion modified carbon paste electrode in 0.04?mol?L?1 universal buffer solution (pH?7.4) is proved successful. The effect of various experimental parameters including pH, scan rate and stability on the voltammetric response of GSH was investigated. At the optimum conditions, the concentration of GSH was determined using differential pulse voltammetry (DPV) in two concentration ranges: 0.1?×?10?7 to 1.6?×?10?5?mol?L?1 and 2.0?×?10?5 to 2.0?×?10?4?mol?L?1 with correlation coefficients 0.9988, 0.9949 and the limit of detections (LOD) are 3.9?×?10?9?mol?L?1 and 8.2?×?10?8?mol?L?1, respectively, which confirmed the sensitivity of the electrode. The high sensitivity, wide linear range, good stability and reproducibility, and the minimal surface fouling make this modified electrode useful for the determination of spiked GSH in urine samples and in tablet with excellent recovery results obtained.  相似文献   

20.
A carbon paste electrode (CPE) was modified with multi-wall carbon nanotubes and successfully applied to the determination of silver ion by differential pulse anodic stripping voltammetry. Compared to a conventional CPE, a remarkably improved peak current response and sensitivity is observed. The analytical procedure consisted of an open circuit accumulation step for 2?min in ?0.4?V, this followed by an anodic potential scan between +0.2 and?+?0.6?V to obtain the voltammetric peak. The oxidation peak current is proportional to the concentration of silver ion in the range from 1.0?×?10?8 to 1.0?×?10?5?mol?L?1, with a detection limit of 1.8?×?10?9?mol?L?1 after an accumulation time of 120?s. The relative standard deviation for 7 successive determinations of Ag(I) at 0.1???M concentration is 1.99%. The procedure was validated by determining Ag(I) in natural waters.
Figure
Differential pulse voltammogram (DPV) of Ag+ solution at MCPE  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号