首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Here we report the first application of a matrix-assisted laser desorption/ionization (MALDI) triple-quadrupole mass spectrometer for targeted proteomics. Employing an amine-specific isotopic labelling approach, the technique was validated using five randomly selected bovine serum albumin peptides differentially labelled at known ratios. An indirect benefit of the isotopic labelling technique is a significant enhancement of the a1 ion in tandem mass (MS/MS) spectra of all peptides studied. Therefore, the a1 ion was selected as the fragment ion for multiple reaction monitoring (MRM) in all cases, eliminating tedious method development and optimization. Accurate quantification was achieved with an average relative standard deviation (RSD) of 5% (n = 5) and a detection limit of 14 amol. The technique was then applied to validate an important virulence biomarker of the fungal pathogen Candida albicans, which was not accurately quantified using global proteomics experiment employing two-dimensional liquid chromatography/electrospray ionization tandem mass spectrometry (2D-LC/ESI)-MS/MS. Using LC/MALDI-MRM analysis of five tryptic peptides, the protein PHR1 was found to be upregulated in the hyphal (pathogenic) form of C. albicans by a factor of 7.7 +/- 0.8.  相似文献   

2.
Stable isotope labeling with (18)O is a promising technique for obtaining both qualitative and quantitative information from a single differential protein expression experiment. The small 4 Da mass shift produced by incorporation of two molecules of (18)O, and the lack of available methods for automated quantification of large data sets has limited the use of this approach with electrospray ionization-ion trap (ESI-IT) mass spectrometers. In this paper, we describe a method of acquiring ESI-IT mass spectrometric data that provides accurate calculation of relative ratios of peptides that have been differentially labeled using(18)O. The method utilizes zoom scans to provide high resolution data. This allows for accurate calculation of (18)O/(16)O ratios for peptides even when as much as 50% of a (18)O labeled peptide is present as the singly labeled species. The use of zoom scan data also provides sufficient resolution for calculating accurate ratios for peptides of +3 and lower charge states. Sequence coverage is comparable to that obtained with data acquisition modes that use only MS and MS/MS scans. We have employed a newly developed analysis software tool, ZoomQuant, which allows for the automated analysis of large data sets. We show that the combination of zoom scan data acquisition and analysis using ZoomQuant provides calculation of isotopic ratios accurate to approximately 21%. This compares well with data produced from (18)O labeling experiments using time of flight (TOF) and Fourier transform-ion cyclotron resonance (FT-ICR) MS instruments.  相似文献   

3.
Arginine and lysine methylation are widespread protein post-translational modifications. Peptides containing these modifications are difficult to retain using traditional reversed-phase liquid chromatography because they are intrinsically basic/hydrophilic and often fragment poorly during collision induced fragmentation (CID). Therefore, they are difficult to analyze using standard proteomic workflows. To overcome these caveats, we performed peptide separations at neutral pH, resulting in increased retention of the hydrophilic/basic methylated peptides before identification using MS/MS. Alternatively trifluoroacetic acid (TFA) was used for increased trapping of methylated peptides. Electron-transfer dissociation (ETD) mass spectrometry was then used to identify and characterize methylated residues. In contrast to previous reports utilizing ETD for arginine methylation, we observed significant amount of side-chain fragmentation. Using heavy methyl stable isotope labeling with amino acids in cell culture it was shown that, similar to CID, a loss of monomethylamine or dimethylamine from the arginine methylated side-chain during ETD can be used as a diagnostic to determine the type of arginine methylation. CID of lysine methylated peptides does not lead to significant neutral losses, but ETD is still beneficial because of the high charge states of such peptides. The developed LC MS/MS methods were successfully applied to tryptic digests of a number of methylated proteins, including splicing factor proline-glutamine-rich protein (SFPQ), RNA and export factor-binding protein 2 (REF2-I) and Sul7D, demonstrating significant advantages over traditional LC MS/MS approaches.  相似文献   

4.
The relative quantification and identification of proteins by matrix‐assisted laser desorption ionization time‐of‐flight MS is very important in /MS is very important in protein research and is usually conducted separately. Chemical N‐terminal derivatization with 4‐sulphophenyl isothiocyanate facilitates de novo sequencing analysis and accurate protein identification, while 18O labeling is simple, specific and widely applicable among the isotopic labeling methods used for relative quantification. In the present study, a method combining 4‐sulphophenyl isothiocyanate derivatization with 18O isotopic labeling was established to identify and quantify proteins simultaneously in one experiment. Reaction conditions were first optimized using a standard peptide (fibrin peptide) and tryptic peptides from the model protein (bovine serum albumin). Under the optimized conditions, these two independent labeling steps show good compatibility, and the linear relativity of quantification within the ten times dynamic range was stable as revealed by correlation coefficient analysis (R2 value = 0.998); moreover, precursor peaks in MS/MS spectrum could provide accurate quantitative information, which is usually acquired from MS spectrum, enabling protein identification and quantification in a single MS/MS spectrum. Next, this method was applied to native peptides isolated from spider venoms. As expected, the de novo sequencing results of each peptide matched with the known sequence precisely, and the measured quantitative ratio of each peptide corresponded well with the theoretical ratio. Finally, complex protein mixtures of spider venoms from male and female species with unknown genome information were analyzed. Differentially expressed proteins were successfully identified, and their quantitative information was also accessed. Taken together, this protein identification and quantification method is simple, reliable and efficient, which has a good potential in the exploration of peptides/proteins from species with unknown genome. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
Isobaric peptide termini labeling (IPTL) is a quantification method which permits relative quantification using quantification points distributed throughout the whole tandem mass spectrometry (MS/MS) spectrum. It is based on the complementary derivatization of peptide termini with different isotopes resulting in isobaric peptides. Here, we use our recently developed software package IsobariQ to investigate how processing and data analysis parameters can improve IPTL data. Deisotoping provided cleaner MS/MS spectra and improved protein identification and quantification. Denoising should be used with caution because it may remove highly regulated ion pairs. An outlier detection algorithm on the ratios within every individual MS/MS spectrum was beneficial in removing false-positive quantification points. MS/MS spectra using IPTL typically contain two peptide series with complementary labels resulting in lower Mascot ion scores than non-labeled equivalent peptides. To avoid this penalty, the two chemical modifications for IPTL were specified as variables including satellite neutral losses of tetradeuterium with positive loss for the heavy isotopes and negative loss for the light isotopes. Thus, the less dominant complementary ion series were not considered for the scoring, which improved the ion scores significantly. In addition, we showed that IPTL was suitable for fragmentation by electron transfer dissociation (ETD) and higher energy collisionally activated dissociation (HCD) besides the already reported collision-induced dissociation (CID). Notably, ETD and HCD data can be identified and quantified using IsobariQ. ETD outperformed CID and HCD only for charge states ≥4+ but yielded in total fewer protein identifications and quantifications. In contrast, the high-resolution information of HCD fragmented peptides provided most identification and quantification results using the same scan speed.  相似文献   

6.
We have demonstrated the use of per-methyl esterification of peptides for relative quantification of proteins between two mixtures of proteins and automated de novo sequence derivation on the same dataset. Protein mixtures for comparison were digested to peptides and resultant peptides methylated using either d0- or d3-methanol. Methyl esterification of peptides converted carboxylic acids, such as are present on the side chains of aspartic and glutamic acid as well as the carboxyl terminus, to their corresponding methyl esters. The separate d0- and d3-methylated peptide mixtures were combined and the mixture subjected to microcapillary high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Parent proteins of methylated peptides were identified by correlative database searching of peptide tandem mass spectra. Ratios of proteins in the two original mixtures could be calculated by normalization of the area under the curve for identical charge states of d0- to d3-methylated peptides. An algorithm was developed that derived, without intervention, peptide sequence de novo by comparison of tandem mass spectra of d0- and d3-peptide methyl esters.  相似文献   

7.
The main goal of comparative proteomics is the quantitation of the differences in abundance of many proteins between two different biological samples in a single experiment. By differentially labeling the peptides from the two samples and combining them in a single analysis, relative ratios of protein abundance can be accurately determined. Protease catalyzed (18)O exchange is a simple method to differentially label peptides, but the lack of robust software tools to analyze the data from mass spectra of (18)O labeled peptides generated by common ion trap mass spectrometers has been a limitation. ZoomQuant is a stand-alone computational tool that analyzes the mass spectra of (18)O labeled peptides from ion trap instruments and determines relative abundance ratios between two samples. Starting with a filtered list of candidate peptides that have been successfully identified by Sequest, ZoomQuant analyzes the isotopic forms of the peptides using high-resolution zoom scan spectrum data. The theoretical isotope distribution is determined from the peptide sequence and is used to deconvolute the peak areas associated with the unlabeled, partially labeled, and fully labeled species. The ratio between the labeled and unlabeled peptides is then calculated using several different methods. ZoomQuant's graphical user interface allows the user to view and adjust the parameters for peak calling and quantitation and select which peptides should contribute to the overall abundance ratio calculation. Finally, ZoomQuant generates a summary report of the relative abundance of the peptides identified in the two samples.  相似文献   

8.
Pooled tongue coating samples from 64 hepatitis B patients and 24 healthy adults were studied and a major band of differential proteins was found by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS‐PAGE). The differential proteins in this band were identified and proved to be keratins by liquid chromatography/tandem mass spectrometry (LC/MS/MS) and Western blot analysis. Furthermore, relative quantification of the identified keratins was performed via using stable isotopic labeling and matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS), showing the higher expression level of these keratins in tongue coating samples of hepatitis B patients than healthy adults. These results provided additional information to understand the medical diagnosis depending on the tongue coating. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Determining the relative levels of neuropeptides in two samples is important for many biological studies. An efficient, sensitive and accurate technique for relative quantitative analysis involves tagging the peptides in the two samples with isotopically distinct labels, pooling the samples and analyzing them using liquid chromatography/mass spectrometry (LC/MS). In this study, we compared two different sets of isotopic tags for analysis of endogenous mouse pituitary peptides: succinic anhydride with either four hydrogens or deuteriums and [3-(2,5-dioxopyrrolidin-1-yloxycarbonyl)propyl]trimethylammonium chloride with either nine hydrogens or deuteriums. These two labels react with amines and impart either a negative charge (succinyl) or a positive charge (4-trimethylammoniumbutyryl (TMAB)). Every endogenous mouse pituitary peptide labeled with the light TMAB reagent eluted from the C18 reversed-phase column at essentially the same time as the corresponding peptide labeled with the heavy reagent. Most of the peptides labeled with succinyl groups also showed co-elution of the heavy- and light-labeled forms on LC/MS. The mass difference between the heavy and light TMAB reagents (9 Da per label) was larger than that of the heavy and light succinyl labels (4 Da per label), and for some peptides the larger mass difference provided more accurate determination of the relative abundance of each form. Altogether, using both labels, 82 peptides were detected in Cpe(fat/fat) mouse pituitary extracts. Of these, only 16 were detected with both labels, 41 were detected only with the TMAB label and 25 were detected only with the succinyl label. A number of these peptides were de novo sequenced using low-energy collisional tandem mass spectrometry. Whereas the succinyl group was stable to the collision-induced dissociation of the peptide, the TMAB-labeled peptides lost 59 Da per H9 TMAB group. Several peptides identified in this analysis represent previously undescribed post-translational processing products of known pituitary prohormones. In conclusion, both succinyl and TMAB isotopic labels are useful for quantitative peptidomics, and together these two labels provide more complete coverage of the endogenous peptides. Copyright (c) 2005 John Wiley & Sons, Ltd.  相似文献   

10.
Protein oxidation is typically associated with oxidative stress and aging and affects protein function in normal and pathological processes. Additionally, deliberate oxidative labeling is used to probe protein structure and protein–ligand interactions in hydroxyl radical protein footprinting (HRPF). Oxidation often occurs at multiple sites, leading to mixtures of oxidation isomers that differ only by the site of modification. We utilized sets of synthetic, isomeric “oxidized” peptides to test and compare the ability of electron-transfer dissociation (ETD) and collision-induced dissociation (CID), as well as nano-ultra high performance liquid chromatography (nanoUPLC) separation, to quantitate oxidation isomers with one oxidation at multiple adjacent sites in mixtures of peptides. Tandem mass spectrometry by ETD generates fragment ion ratios that accurately report on relative oxidative modification extent on specific sites, regardless of the charge state of the precursor ion. Conversely, CID was found to generate quantitative MS/MS product ions only at the higher precursor charge state. Oxidized isomers having multiple sites of oxidation in each of two peptide sequences in HRPF product of protein Robo-1 Ig1-2, a protein involved in nervous system axon guidance, were also identified and the oxidation extent at each residue was quantified by ETD without prior liquid chromatography (LC) separation. ETD has proven to be a reliable technique for simultaneous identification and relative quantification of a variety of functionally different oxidation isomers, and is a valuable tool for the study of oxidative stress, as well as for improving spatial resolution for HRPF studies.
Figure
?  相似文献   

11.
An algorithm is presented for the generation of a reliable peptide component peak table from liquid chromatography-mass spectrometry (LC-MS) and subsequent quantitative analysis of stable isotope coded peptide samples. The method uses chemical noise filtering, charge state fitting, and deisotoping toward improved analysis of complex peptide samples. Overlapping peptide signals in mass spectra were deconvoluted by correlation with modeled peptide isotopic peak profiles. Isotopic peak profiles for peptides were generated in silico from a protein database producing reference model distributions. Doublets of heavy and light labeled peak clusters were identified and compared to provide differential quantification of pairs of stable isotope coded peptides. Algorithms were evaluated using peptides from digests of a single protein and a seven-protein mixture that had been differentially coded with stable isotope labeling agents and mixed in known ratios. The experimental results correlated well with known mixing ratios.  相似文献   

12.
Highly complex protein mixtures can be analyzed after proteolysis using liquid chromatography/mass spectrometry (LC/MS). In an LC/MS run, intense peptide ions originating from high-abundance proteins are preferentially analyzed using tandem mass spectrometry (MS(2)), so obtaining the MS(2) spectra of peptide ions from low-abundance proteins is difficult even if such ions are detected. Furthermore, the MS(2) spectra may produce insufficient information to identify the peptides or proteins. To solve these problems, we have developed a real-time optimization technique for MS(2), called the Information-Based-Acquisition (IBA) system. In a preliminary LC/MS run, a few of the most intense ions detected in every MS spectrum are selected as precursors for MS(2) and their masses, charge states and retention times are automatically registered in an internal database. In the next run, a sample similar to that used in the first run is analyzed using database searching. Then, the ions registered in the database are excluded from the precursor ion selection to avoid duplicate MS(2) analyses. Furthermore, real-time de novo sequencing is performed just after obtaining the MS(2) spectrum, and an MS(3) spectrum is obtained for accurate peptide identification when the number of interpreted amino acids in the MS(2) spectrum is less than five. We applied the IBA system to a yeast cell lysate which is a typical crude sample, using a nanoLC/ion-trap time-of flight (IT/TOF) mass spectrometer, repeating the same LC/MS run five times. The obtained MS(2) and MS(3) spectra were analyzed by applying the Mascot (Matrix Science, Boston, MA, USA) search engine to identify proteins from the sequence database. The total number of identified proteins in five LC/MS runs was three times higher than that in the first run and the ion scores for peptide identification also significantly increased, by about 70%, when the MS(3) spectra were used, combined with the MS(2) spectra, before being subjected to Mascot analysis.  相似文献   

13.
Hsu JL  Huang SY  Chen SH 《Electrophoresis》2006,27(18):3652-3660
Stable-isotope labeling coupled with liquid-phase separation and MS analysis is a powerful technique for comparative proteomics. We developed a dimethyl labeling strategy (Anal. Chem. 2003, 75, 6843-6852 and J. Proteome Res. 2005, 4, 101-108) to label peptide N-terminus and epsilon-amino groups of Lys with water-soluble formaldehyde via reductive methylation, and an isotopic pair of formaldehyde is used for binary labeling on two sets of samples. In this study, this approach is extended to a four sample labeling by combining the binary isotopic reagents of formaldehyde (d0, d2) and the binary isotopic reducing reagents, sodium cyanoborohydride (d0, d3). To ensure sufficient mass difference, this multiplexed labeling is coupled with endoproteinase Lys-C instead of trypsin for digestion, resulting in at least two labeling sites with a mass difference of 4 Da for each pair of peptide digest. Moreover, multiplex dimethyl labeling was proved to have no significant isotopic effect during RP LC elution. This method was further applied for monitoring Lys-C digestion using hemoglobin as a model. Dimethyl labeled digests derived from seven time points (1-30 h) were grouped into two sets of sample mixtures, separated by nano-LC to reduce the complexity, and then analyzed by ESI-MS/MS. The temporal study reveals that Lys-C digestion was completed in 10-15 h for all detected peptides. The multiplex dimethyl method has not only provided a simultaneous detection mean for four sample sets but has also conserved all the advantages associated with the original binary method.  相似文献   

14.
Quantitative or comparative proteome analysis was initially performed with 2-dimensional gel electrophoresis with the inherent disadvantages of being biased towards certain proteins and being labor intensive. Alternative mass spectrometry-based approaches in conjunction with gel-free protein/peptide separation have been developed in recent years using various stable isotope labeling techniques. Common to all these techniques is the incorporation, biosynthetically or chemically, of a labeling moiety having either a natural isotope distribution of hydrogen, carbon, oxygen, or nitrogen (light form) or being enriched with heavy isotopes like deuterium, (13)C, (18)O, or (15)N, respectively. By mixing equal amounts of a control sample possessing for instance the light form of the label with a heavy-labeled case sample, differentially labeled peptides are detected by mass spectrometric methods and their intensities serve as a means for direct relative protein quantification. While each of the different labeling methods has its advantages and disadvantages, the endoprotease (16)O-to-(18)O catalyzed oxygen exchange at the C-terminal carboxylic acid is extremely promising because of the specificity assured by the enzymatic reaction and the labeling of essentially every protease-derived peptide. We show here that this methodology is applicable to complex biological samples such as a subfraction of human plasma. Furthermore, despite the relatively small mass difference of 4 Da between the two labeled forms, corresponding to the exchange of two oxygen atoms by two (18)O isotopes, it is possible to quantify differentially labeled proteins on an ion trap mass spectrometer with a mass resolution of about 2000 in automated data dependent LC-MS/MS acquisition mode. Post column sample deposition on a MALDI target parallel to on-line ESI-MS/MS enables the analysis of the same compounds by means of ESI- and MALDI-MS/MS. This has the potential to increase the confidence in the quantification results as well as to increase the sequence coverage of potentially interesting proteins by complementary peptide ionization techniques. Additionally the paired y-ion signals in tandem mass spectra of (16)O/(18)O-labeled peptide pairs provide a means to confirm automatic protein identification results or even to assist de novo sequencing of yet unknown proteins.  相似文献   

15.
建立了定量肽段串联体蛋白质(concatamers of Q peptides, QconCATs)结合18O同位素标记-多反应监测质谱的蛋白质绝对定量新方法。首先对QconCAT重组蛋白质进行了纯度表征,十二烷基硫酸钠-聚丙烯酰胺凝胶电泳(SDS-PAGE)表征结果表明重组蛋白质的纯度在99%以上,相对分子质量约为63.4 kDa。对QconCAT重组蛋白质酶切后的肽段混合物进行质谱分析,并经pFind和pLabel软件处理,验证了目标肽段。还考察了QconCAT重组蛋白质的酶切效率和18O标记效率,并对QconCAT蛋白质结合18O标记-同位素稀释-多反应监测质谱方法进行了评价。实验结果表明,采用该方法对腾冲嗜热厌氧菌(Thermoanaerobacter tengcongensis, TTE)中选定蛋白质的肽段进行绝对含量测定时,相对标准偏差小于20%,准确度较高,说明该方法可用于复杂生物样本中蛋白质的绝对定量。更重要的是所建方法不仅解决了细胞培养氨基酸稳定同位素标记(SILAC)技术的重标试剂价格昂贵的问题,也为定量蛋白质组学提供了一种新的方法。  相似文献   

16.
Accurately measured peptide masses can be used for large-scale protein identification from bacterial whole-cell digests as an alternative to tandem mass spectrometry (MS/MS) provided mass measurement errors of a few parts-per-million (ppm) are obtained. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) routinely achieves such mass accuracy either with internal calibration or by regulating the charge in the analyzer cell. We have developed a novel and automated method for internal calibration of liquid chromatography (LC)/FTICR data from whole-cell digests using peptides in the sample identified by concurrent MS/MS together with ambient polydimethylcyclosiloxanes as internal calibrants in the mass spectra. The method reduced mass measurement error from 4.3 +/- 3.7 ppm to 0.3 +/- 2.3 ppm in an E. coli LC/FTICR dataset of 1000 MS and MS/MS spectra and is applicable to all analyses of complex protein digests by FTICRMS.  相似文献   

17.
Polyacrylamide gel electrophoresis is widely used for protein separation and it is frequently the final step in protein purification in biochemistry and proteomics. Using a commercially available amine-reactive isobaric tagging reagent (iTRAQ) and mass spectrometry we obtained reproducible, quantitative data from peptides derived by tryptic in-gel digestion of proteins and phosphoproteins. The protocol combines optimized reaction conditions, miniaturized peptide handling techniques and tandem mass spectrometry to quantify low- to sub-picomole amounts of (phospho)proteins that were isolated by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Immobilized metal affinity chromatography (FeIII-IMAC) was efficient for removal of excess reagents and for enrichment of derivatized phosphopeptides prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis. Phosphopeptide abundance was determined by liquid chromatography/tandem mass (LC/MS/MS) using either MALDI time-of-flight/time-of-flight (TOF/TOF) MS/MS or electrospray ionization quadrupole time-of-flight (ESI-QTOF) MS/MS instruments. Chemically labeled isobaric phosphopeptides, differing only by the position of the phosphate group, were distinguished and characterized by LC/MS/MS based on their LC elution profile and distinct MS/MS spectra. We expect this quantitative mass spectrometry method to be suitable for systematic, comparative analysis of molecular variants of proteins isolated by gel electrophoresis.  相似文献   

18.
Two peptide quantification strategies, the isobaric tags for relative or absolute quantitation (iTRAQ) labeling methodology and a metal-chelate labeling approach, were compared using matrix-assisted laser desorption/ionization-TOF/TOF MS and MS/MS analysis. Amino- and cysteine-directed labeling using the rare earth metal chelator 1,4,7,10-tetraazacyclododecane-N,N′,N″,N″′-tetraacetic acid (DOTA) were applied for relative quantification of single peptides and a six-protein mixture. For analyte ratios close to one, iTRAQ and amino-directed DOTA labeling delivered overall comparable results regarding accuracy and reproducibility. In contrast, the MS-based quantification via amino-directed lanthanide-DOTA tags was more accurate for analyte ratios ≥5 and offered an extended dynamic range of three orders of magnitude. Our results show that the amino-directed DOTA labeling is an alternative relative quantification tool offering advantages like flexible multiplexing possibilities and, in particular, large dynamic ranges, which should be useful in sophisticated, targeted issues, where the accurate determination of extremely different protein or peptide concentration becomes relevant.  相似文献   

19.
Liquid chromatography (LC) electron transfer dissociation (ETD) tandem mass spectrometry (MS/MS) of protein digests is demonstrated in a hybrid quadrupole‐hexapole orthogonal time‐of‐flight (OTOF) mass spectrometer. Analyte ions are selected in a mass‐analyzing quadrupole, accumulated in the hexapole linear ETD reaction cell and mutually stored with ETD reagent anions. Product ions are collected in an ion cooler and then analyzed by an OTOF mass analyzer. The hexapole structure of the ETD reaction cell allows for a broad fragment ion mass range distribution and a high ion storage capacity. Analytically useful ETD OTOF‐MS/MS spectra could be obtained at a rate of faster than 2 Hz. When used in conjunction with LC this high speed allows for several MS and MS/MS spectra to be obtained across each LC peak. An MS scan is used to select the precursor ions. With a 1 m flight tube and single reflection, resolutions of about 10 k and a mass accuracy of 5 ppm were achieved. When analyzing a 100 fmol solution of a tryptic digest of bovine serum albumin (BSA) by LC/ETD MS/MS, 27 unique peptides were identified with a summed Mascot score of 1316 using the Swiss Prot database. In addition, we explored the capability for analyzing small proteins with the present hybrid instrument. ETD MS/MS of intact ubiquitin ([M+12H]12+) leads to the identification of the protein with a Mascot score of 264. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
Nowadays, the most common strategies used in quantitative proteomics are based on isotope-coded labeling followed by specific molecule mass spectrometry. The implementation of inductively coupled plasma mass spectrometry (ICP-MS) for quantitative purposes can solve important drawbacks such as lack of sensitivity, structure-dependent responses, or difficulties in absolute quantification. Recently, lanthanide-containing labels as metal-coded affinity tag (MeCAT) reagents have been introduced, increasing the interest and scope of elemental mass spectrometry techniques for quantitative proteomics. In this work one of the first methodologies for absolute quantification of peptides and proteins using MeCAT labeling is presented. Liquid chromatography (LC) interfaced to ICP-MS has been used to separate and quantify labeled peptides while LC coupled to electrospray ionization mass spectrometry served for identification tasks. Synthetic-labeled peptides were used as standards to calibrate the response of the detector with compounds as close as possible to the target species. External calibration was employed as a quantification technique. The first step to apply this approach was MeCAT-Eu labeling and quantification by isotope dilution ICP-MS of the selected peptides. The standards were mixed in different concentrations and subjected to reverse-phase chromatography before ICP-MS detection to consider the column effect over the peptides. Thus, the prepared multi-peptide mix allowed a calibration curve to be obtained in a single chromatographic run, correcting possible non-quantitative elutions of the peptides from the column. The quantification strategy was successfully applied to other labeled peptides and to standard proteins such as digested lysozyme and bovine serum albumin.  相似文献   