首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The use of surfactant mixtures to affect both EOF and separation selectivity in electrophoresis with PDMS substrates is reported, and capacitively coupled contactless conductivity detection is introduced for EOF measurement on PDMS microchips. First, the EOF was measured for two nonionic surfactants (Tween 20 and Triton X‐100), mixed ionic/nonionic surfactant systems (SDS/Tween 20 and SDS/Triton X‐100), and finally for the first time, mixed zwitterionic/nonionic surfactant systems (TDAPS/Tween 20 and TDAPS/Triton X‐100). EOF for the nonionic surfactants decreased with increasing surfactant concentration. The addition of SDS or TDAPS to a nonionic surfactant increased EOF. After establishing the EOF behavior, the separation of model catecholamines was explored to show the impact on separations. Similar analyte resolution with greater peak heights was achieved with mixed surfactant systems containing Tween 20 and TDAPS relative to the single surfactant system. Finally, the detection of catecholamine release from PC12 cells by stimulation with 80 mM K+ was performed to demonstrate the usefulness of mixed surfactant systems to provide resolution of biological compounds in complex samples.  相似文献   

2.
In-channel indirect amperometric detection mode for microchip capillary electrophoresis with positive separation electric field is successfully applied to some heavy metal ions. The influences of separation voltage, detection potential, the concentration and pH value of running buffer on the response of the detector have been investigated. An optimized condition of 1200 V separation voltage, −0.1 V detection potential, 20 mM (pH 4.46) running buffer of 2-(N-morpholino)ethanesulfonic acid (MES) + l-histidine (l-His) was selected. The results clearly showed that Pb2+, Cd2+, and Cu2+ were efficiently separated within 80 s in a 3.7 cm long native separation PDMS/PDMS channel and successfully detected at a single carbon fibre electrode. The theoretical plate numbers of Pb2+, Cd2+, and Cu2+ were 1.2 × 105, 2.5 × 105, and 1.9 × 105 m−1, respectively. The detection limits for Pb2+, Cd2+, and Cu2+ were 1.3, 3.3 and 7.4 μM (S/N = 3).  相似文献   

3.
The use of mixtures of ionic and zwitterionic surfactants in poly(dimethylsiloxane) (PDMS) microchips is reported. The effect of surfactant concentration on electroosmotic flow (EOF) was studied for a single anionic surfactant (sodium dodecyl sulfate, SDS), a single zwitterionic surfactant (N-tetradecylammonium-N,N-dimethyl-3-ammonio-1-propanesulfonate, TDAPS), and a mixed SDS/TDAPS surfactant system. SDS increased the EOF as reported previously while TDAPS showed an initial increase in EOF followed by a reduction at higher concentrations. When TDAPS was added to a solution containing SDS, the EOF decreased in a concentration-dependent manner. The EOF for all three surfactant systems followed expected pH trends, with increasing EOF at higher pH. The mixed surfactant system allowed tuning of the EOF across a range of pH and concentration conditions. After establishing the EOF behavior, the adsorption/desorption kinetics were measured and showed a slower adsorption/desorption rate for TDAPS than SDS. Finally, the separation and electrochemical detection of model catecholamines in buffer and reduced glutathione in red blood cell lysate using the mixed surfactant system were explored. The mixed surfactant system provided shorter analysis times and/or improved resolution when compared to the single surfactant systems.  相似文献   

4.
Due to the mounting evidence of altered low-density lipoprotein (LDL) size in several disease states, there has been an increasing interest in developing new analytical methods for small, dense low-density lipoprotein (sdLDL) for diagnosis. The present report demonstrates that sdLDL analysis can be performed in a poly(dimethylsiloxane) (PDMS/glass) microchannel. n-Dodecyl β-d-maltoside (DDM) was utilized to alter channel surface to make it become hydrophilic and nonionic, thus reducing the interaction between the protein and the surface. Moreover, hydroxypropylcellulose (HPC) was added into the running buffer to suppress the adsorption of analytes and also to serve as a sieving matrix. Under optimal conditions, two baseline separations of lipoproteins including high-density lipoprotein (HDL), sdLDL, and lLDL were achieved with different selectivity. LDL particles shown on the electropherogram were also identified by several procedures. This method affords high separation speed and high reproducibility. The intraassay and interassay RSDs of lipoprotein migration times were in the range of 2.01–2.45%. The variation of serum sdLDL of a patient between prior treatment and post-treatment was assessed by this method. This system has the potential for rapid and sensitive detection of different LDL forms, and thus will be applicable to clinical diagnosis.  相似文献   

5.
A capillary electrophoresis (CE) microchip made of a new and promising polymeric material: Topas (thermoplastic olefin polymer of amorphous structure), a cyclic olefin copolymer with high chemical resistance, has been tested for the first time with analytical purposes, employing an electrochemical detection. A simple end-channel platinum amperometric detector has been designed, checked, and optimized in a poly-(methylmethacrylate) (PMMA) CE microchip. The end-channel design is based on a platinum wire manually aligned at the exit of the separation channel. This is a simple and durable detection in which the working electrode is not pretreated. H(2)O(2) was employed as model analyte to study the performance of the PMMA microchip and the detector. Factors influencing migration and detection processes were examined and optimized. Separation of H(2)O(2) and L-ascorbic acid (AsA) was developed in order to evaluate the efficiency of microchips using different buffer systems. This detection has been checked for the first time with a microchip made of Topas, obtaining a good linear relationship for mixtures of H(2)O(2) and AsA in different buffers.  相似文献   

6.
A rapid and sensitive DNA targets detection using enzyme amplified electrochemical detection (ED) based on microchip was described. We employed a biotin‐modified DNA, which reacted with avidin‐conjugated horseradish peroxidase (avidin–HRP) to obtain the HRP‐labeled DNA probe and hybridized with its complementary target. After hybridization, the mixture containing dsDNA‐HRP, excess ssDNA‐HRP, and remaining avidin–HRP was separated by MCE. The separations were performed at a separation voltage of +1.6 kV and were completed in less than 100 s. The HRP was used as catalytic labels to catalyze H2O2/o‐aminophenol reaction. Target DNA could be detected by the HRP‐catalyzed reduction with ED. With this protocol, the limits of quantification for the hybridization assay of 21‐ and 39‐mer DNA fragments were of 8×10?12 M and 1.2×10?11 M, respectively. The proposed method has been applied satisfactorily in the analysis of Escherichia coli genomic DNA. We selected the detection of PCR amplifications from the gene of E. coli to test the real applicability of our method. By using an asymmetric PCR protocol, we obtained ssDNA targets of 148 bp that could be directly hybridized by the single‐stranded probe and detected with ED.  相似文献   

7.
A novel method for rapid separation and determination of ascorbic acid and uric acid has been developed with a polycation-modified poly(dimethylsiloxane) (PDMS) microchip under a negative-separation electric field. Just by flushing the microchip with aqueous solutions of the polycations, poly(allylamine) hydrochloride, poly(diallyldimethylammonium chloride) or chitosan could be stably coated on the PDMS microchannel surface, which resulted in a reversed electroosmotic flow and thus the rapid and efficient separation of the two substrates. Factors influencing the separation, including polycation category, buffer solution, detection potential and separation voltage, were investigated and optimized. The cheapness, rapid analysis speed and the successful analysis of human urine make this microsystem attractive for application in clinics. Figure The electropherograms of 100 μ/mL AA and UA in (1) PAH, (2) PDDA, (3) Chitosan modified PDMS microchannels and native PDMS microchip (4).  相似文献   

8.
A mixture of five amino acids including arginine, histidine, phenylalanine, serine and glutamic acid was successfully separated in microchip capillary electrophoresis and detected with laser-induced fluorescence (LIF) detector. These amino acids were labeled with 5-(4, 6-dichloro-s-triazin-2-ylamino) fluorescein (DTAF). The analyses were performed on two kinds of modified poly(dimethylsiloxane) (PDMS) microchips. One kind of chip was simply treated with oxygen plasma (OP-chip), and the other was further modified by coating double layers of non-ionic polymer poly(vinyl alcohol) (PVA) after plasma oxidization (PVA-chip). The derivatization condition of amino acids by DTAF was optimized. The properties of the two modified PDMS microchips were studied and separation conditions, such as the buffer pH, buffer concentration and separation voltage, were also optimized. The column efficiencies of the two microchips were in the range of 193,000–1,370,000 plates/m. The DTAF-labeled amino acids were sufficiently separated within 50 s and 90 s in 2.5 cm channels on OP-chip and PVA-chip, respectively.  相似文献   

9.
Poly(dimethylsiloxane) microfluidic channels alternately modified by poly(diallyldimethylammonium chloride) and poly(sodium 4-styrenesulfonate) were successfully used to separate uric acid and ascorbic acid. Results show that uric acid and ascorbic acid can be well separated and detected simultaneously in modified microchips coupled with in-channel electrochemical detection. Under the optimal conditions, the linear ranges of uric acid and ascorbic acid were both from 25 to 600 microM, with the correlation coefficients of 0.997 and 0.996, respectively. The detection limits were 8 microM for uric acid and 5 microM for ascorbic acid. Factors influencing separation and detection, including buffer solution, detection potential and separation voltage, were investigated and optimized. In addition, the dependences of the current response on sensitivity and reproducibility were studied, and the stability of the device was also evaluated in detail. This method was successfully used to determine uric acid and ascorbic acid in human urine.  相似文献   

10.
In this paper, a simple and green modification method is developed for biomolecules analysis on poly(dimethylsiloxane) (PDMS) microchip with successful depression of nonspecific biomolecules adsorption. O-[(N-succinimdyl)succiny]-o'-methyl-poly(ethylene glycol) was explored to form hydrophilic surface via in-situ grafting onto pre-coated chitosan (Chit) from aqueous solution in the PDMS microchannel. The polysaccharide chains backbone of Chit was strongly attracted onto the surface of PDMS via hydrophobic interaction combined with hydrogen bonding in an alkaline medium. The methyl-poly(ethylene glycol) (mPEG) could produce hydrophilic domains on the mPEG/aqueous interface, which generated brush-like coating in this way and revealed perfect resistance to nonspecific adsorption of biomolecules. This strategy could greatly improve separation efficiency and reproducibility of biomolecules. Amino acids and proteins could be efficiently separated and successfully detected on the coated microchip coupled with end-channel amperometric detection at a copper electrode. In addition, it offered an effective means for preparing biocompatible and hydrophilic surface on microfluidic devices, which may have potential use in the biological analysis.  相似文献   

11.
Xu JJ  Peng Y  Bao N  Xia XH  Chen HY 《Electrophoresis》2005,26(19):3615-3621
In the present paper, we describe a microfluidics-based sensing system for nonelectroactive anions under negative separation electric field by mounting a single carbon fiber disk working electrode (WE) in the end part of a poly(dimethylsiloxane) microchannel. In contrast to work in a positive separation electric field described in our previous paper (Anal. Chem. 2004, 76, 6902-6907), here the electrochemical reduction reaction at the WE is not coupled with the separation high-voltage (HV) system, whereas the electrochemical oxidation reaction at the WE is coupled with the separation HV system. The electroactive indicator is the carbon fiber WE itself but not dissolved oxygen. This provides a convenient and sensitive means for the determination of nonelectroactive anions by amperometry. The influences of separation voltage, detection potential, and the distance between the WE and the separation channel outlet on the response of the detector have been investigated. The present detection mode is successfully used to electrochemically detect F-, Cl-, SO4(2-), CH3COO-, H2PO4-. Based on the preliminary results, a detection limit of 2 microM and a dynamic range up to three orders of magnitude for Cl- could be achieved.  相似文献   

12.
Poly(dimethylsiloxane) microchip capillary electrophoresis with amperometric detection has been used for rapid separation and determination of acetaminophen and its hydrolysate, i.e. p-aminophenol. A Pt ultramicroelectrode with a diameter of 10 m positioned at the outlet of the separation channel was used as a working electrode for amperometric detection. Factors influencing separation and detection were investigated and optimized. Results show that acetaminophen and p-aminophenol can be well separated within 35 s with RSD<1% for migration time and <7% for detection current for both analytes. Detection limits for both analytes are estimated to be 5.0 mol L–1 (approximately 0.1 fmol) at S/N=3. This method has been successfully applied to the detection of traces of p-aminophenol in paracetamol tablets.  相似文献   

13.
Cheng H  Huang WH  Chen RS  Wang ZL  Cheng JK 《Electrophoresis》2007,28(10):1579-1586
Microelectrodes have been adopted in electrochemical detection for CE or microchip CE in recent years. In this paper, the use of nanoelectrodes (with tip diameter of 100-300 nm) as the electrochemical detector in microchip CE is firstly reported. The experimental results indicated that both the sensitivity and resolution of microchip CE with the carbon fiber nanoelectrode (CFNE) amperometric detection have been improved markedly comparing with the traditional microelectrodes. The detection limit of dopamine (S/N = 3) is 5.9x10(-8) M, which is one or two orders of magnitude lower than that reported so far, and the resolution of dopamine (DA) and isoprenaline (IP) has also improved from 0.6 (using 7 mum carbon fiber microelectrodes, CFME) to 1.0. We assembled a novel and easily operated microchip CE system with end-column amperometric detection, which allows the convenient and fast replacement of the passivated electrodes. Under the optimized condition, the RSDs of peak height and migration time are 1.47 and 0.31%, respectively (n = 40), indicating that the system displays excellent reproducibility. The nanoelectrode-based microchip CE system has been successfully applied to the determination of DA in cultured rat pheochromocytoma (PC12) cells, and the average content of DA in an individual PC12 cell is 0.54 +/- 0.07 fmol, which is in good agreement with that reported in the literature.  相似文献   

14.
A rapid and very sensitive method for the accurate determination of free iodide in real samples is described. The method is based on anion-exchange chromatographic separation coupled with amperometric detection at a modified platinum electrode under constant applied potential (+0.85 V vs. Ag AgCl). An experimental setup with an in-line and very effective method of electrode modification is proposed using an amperometric thin-layer cross-flow detector and a flowing solution 300 mg/L of iodide; the working electrode is polarised to the limiting current for oxidation of iodide to iodine in acidic solutions with the consequent formation of an iodine-based film. The results indicated that the modified electrode exhibits high analytical response for iodide electrooxidation with good stability and long-life. The signal intensity of daily experimental sessions (8 h), during which standards and real samples were repeatedly injected, exhibits a moderate lowering (i.e. <6%). Using a mixture of 25 mM HNO3 and 50 mM NaNO3 as an eluent phase in ion-exchange chromatography, the detection limit of iodide was estimated to be 0.5 g/L (S/N=3) with an injection volume of 50 L. This method was applied successfully to quantify the iodide content of milk samples and in wastewaters as well as trace amounts in common vegetables and solutions containing high chloride levels.  相似文献   

15.
Wu D  Qin J  Lin B 《Lab on a chip》2007,7(11):1490-1496
A straightforward approach to generate a stable and protein-resistant poly(dimethylsiloxane) (PDMS) surface using self-assembled hydrophilic polymers is demonstrated in this work. Epoxy-modified polymers were directly adsorbed from aqueous solution onto plasma oxidized PDMS based on H-bond interaction, and epoxies of polymer and silanols on oxidized PDMS surface were crosslinked by heating at 110 degrees C. The coating process could be completed within half hour. Poly(dimethylacrylamide-co-glycidyl methacrylate) (PDMA-co-GMA), poly(vinyl pyrrolidone)-g-glycidyl methacrylate (PVP-g-GMA) and poly(vinyl alcohol)-g-glycidyl methacrylate (PVA-g-GMA) (D. P. Wu, B. X. Zhao, Z. P. Dai, J. H. Qin and B. C. Lin, Lab Chip, 2006, 6, 942) were employed as examples here. Unlike PDMA, PVP, and PVA themselves, these epoxy-modified hydrophilic polymers could be directly used as static surface coatings on oxidized PDMS, and inhibited electroosmotic flow (EOF) within pH 3-11. It was also found that hard baking of PDMS at 150 degrees C for 24 hours before surface coating could greatly retard surface hydrophobicity recovery after oxygen plasma exposure, which strengthened epoxy-modified polymer coatings on oxidized PDMS surface, and resulted in EOF less than 0.2 x 10(-4) cm(2) V(-1) s(-1) (pH 9.0) within two weeks. On epoxy-modified polymer coated PDMS microchips, basic proteins, peptides and DNA fragments could be separated satisfactorily, in which more than 2 x 10(4) plates per 2 cm and less than 3% RSD (>8 runs) for migration time were obtained for lysozyme.  相似文献   

16.
Dou YH  Bao N  Xu JJ  Meng F  Chen HY 《Electrophoresis》2004,25(17):3024-3031
Separation and detection of proteins have been realized on nonionic surfactant-modified poly(dimethylsiloxane) (PDMS) microfabricated devices with end-column amperometric detection. The hydrophobic PDMS channels are turned into hydrophilic ones after being modified with Brij35 and facilitate the separation of proteins. The coating can remarkably reduce the adsorption of large protein molecules and is stable in the range of pH 6-12. The detection of proteins in such channels needs less rinsing time and thus efficiency is raised. Even large molecules of proteins can also be detected with better reproducibility and enhanced plate numbers. The relative standard deviation (RSD) of the migration time for glucose oxidase (GOD) is 2.2% (n = 19). Separation of GOD and myoglobin has been developed in modified channels. Predominant operational variables, such as the coating conditions, the concentration of surfactant and buffer, are studied in detail.  相似文献   

17.
Kong Y  Chen H  Wang Y  Soper SA 《Electrophoresis》2006,27(14):2940-2950
A novel method of photoresist-free micropatterning coupled with electroless gold plating is described for the fabrication of an integrated gold electrode for electrochemical detection (ED) on a polycarbonate (PC) electrophoresis microchip. The microelectrode layout was photochemically patterned onto the surface of a PC plate by selective exposure of the surface coated without photoresist to 254 nm UV light through a chromium/quartz photomask. Thus, the PC plate was selectively sensitized by formation of reactive chemical moieties in the exposed areas. After a series of wet chemistry reactions, the UV-exposed area was activated with a layer of gold nanoparticles that served as a seed to catalyze the electroless plating. The gold microelectrode was then selectively plated onto the activated area by using an electroless gold plating bath. Nonselective gold deposition on the unwanted areas was eliminated by sonication of the activated PC plate in a KSCN solution before electroless plating, and the adhesion of the plated electrodes to the PC surface was strengthened with thermal annealing. Compared with the previously reported electroless plating technique for fabrication of microelectrodes on a microchip, the present method avoided the use of a membrane stencil with an electrode pattern to restrict the area to be wet-chemically sensitized. The CE with integrated ED (CE-ED) microchip was assembled by thermal bonding an electrode-plated PC cover plate to a microchannel-embossed PC substrate. The novel method allows one to fabricate low-cost, electrode-integrated, complete PC CE-ED chips with no need of a clean room. The fabricated CE-ED microchip was demonstrated for separation and detection of model analytes, including dopamine (DA) and catechol (CA). Detection limits of 0.65 and 1.03 microM were achieved for DA and CA, respectively, and theoretical plate number of 1.4 x 10(4) was obtained for DA. The plated gold electrode can be used for about 4 h, bearing usually more than 100 runs before complete failure.  相似文献   

18.
研究了羟胺在碳纳米管修饰玻碳电极(CNT/GC)上的电化学行为。研究结果表明,碳纳米管对羟胺的电化学行为有良好的电催化作用,在-0.62 V有一还原峰,是羟胺获得2个电子还原为铵所形成,同时测定了该电化学过程的动力学参数:电子转移数n为2,电子转移系数α为0.287,电极反应速率常数k为1.35×10-3cm/s。  相似文献   

19.
《Electroanalysis》2005,17(18):1675-1680
We developed a sensitive, simple and low cost method to determine methimazole based on capillary electrophoresis with electrochemical detection (CE‐EC) at a carbon fiber microdisk electrode (CFE). We investigated the effects of detection potential, the concentration and pH value of the phosphate buffer, and injection time as well as separation voltage on the detection of methimazole. Under the optimized conditions: the detection potential at 1.30 V, 10 mmol/L phosphate buffer (pH 7.0), injection time 30 s at a height of 20 centimeter and separation voltage at 15 kV, the linear range was obtained from 1.0×10?7 to 2.0×10?4 mol/L, covering 3 orders of magnitude with a correlation coefficient of 0.9995. The LOD (S/N=3) obtained was 5.0×10?8 mol/L. The RSD of migration time and peak current for 2.0×10?4 mol/L methimazole was 1.04% and 1.54% (n=10), respectively. The method was also used to analyze methimazole tablets and human urine sample.  相似文献   

20.
The voltammetric behaviour and amperometric detection of tetracycline (TC) antibiotics at multi-wall carbon nanotube modified glassy carbon electrodes (MWCNT-GCE) are reported. Cyclic voltammograms of TCs showed enhanced oxidation responses at the MWCNT-GCE with respect to the bare GCE, attributable to the increased active electrode surface area. Hydrodynamic voltammograms obtained by flow-injection with amperometric detection at the MWCNT-GCE led us to select a potential value E det = +1.20 V. The repeatability of the amperometric responses was much better than that achieved with bare GCE (RSD ranged from 7 to 12%), with RSD values for i p of around 3%, thus demonstrating the antifouling capability of MWCNT modified electrodes. An HPLC method with amperometric electrochemical detection (ED) at the MWCNT-GCE was developed for tetracycline, oxytetracycline (OTC), chlortetracycline and doxycycline (DC). A mobile phase consisting of 18:82 acetonitrile/0.05 mol L−1 phosphate buffer of pH 2.5 was selected. The limits of detection ranged from 0.09 μmol L−1 for OTC to 0.44 μmol L−1 for DC. The possibility to carry out multiresidue analysis is demonstrated. The HPLC-ED/MWCNT-GCE method was applied to the analysis of fish farm pool water and underground well water samples spiked with the four TCs at 2.0 × 10−7 mol L−1. Solid-phase extraction was accomplished for the preconcentration of the analytes and clean-up of the samples. Recoveries ranged from 87 ± 6 to 99 ± 3%. Under preconcentration conditions, limits of detection in the water samples were between 0.50 and 3.10 ng mL−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号