首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PurposeTo develop and validate an accelerated free-breathing 3D whole-heart magnetic resonance angiography (MRA) technique using a radial k-space trajectory with compressed sensing and curvelet transform.MethodA 3D radial phyllotaxis trajectory was implemented to traverse the centerline of k-space immediately before the segmented whole-heart MRA data acquisition at each cardiac cycle. The k-space centerlines were used to correct the respiratory-induced heart motion in the acquired MRA data. The corrected MRA data were then reconstructed by a novel compressed sensing algorithm using curvelets as the sparsifying domain. The proposed 3D whole-heart MRA technique (radial CS curvelet) was then prospectively validated against compressed sensing with a conventional wavelet transform (radial CS wavelet) and a standard Cartesian acquisition in terms of scan time and border sharpness.ResultsFifteen patients (females 10, median age 34-year-old) underwent 3D whole-heart MRA imaging using a standard Cartesian trajectory and our proposed radial phyllotaxis trajectory. Scan time for radial phyllotaxis was significantly shorter than Cartesian (4.88 ± 0.86 min. vs. 6.84 ± 1.79 min., P-value = 0.004). Radial CS curvelet border sharpness was slightly lower than Cartesian and, for the majority of vessels, was significantly better than radial CS wavelet (P-value < 0.050).ConclusionThe proposed technique of 3D whole-heart MRA acquisition with a radial CS curvelet has a shorter scan time and slightly lower vessel sharpness compared to the Cartesian acquisition with radial profile ordering, and has slightly better sharpness than radial CS wavelet. Future work on this technique includes additional clinical trials and extending this technique to 3D cine imaging.  相似文献   

2.
The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysms. In order to reduce scan time, parallel imaging was combined with an acquisition strategy that eliminates the corners of k-space. In the two patients with intracranial stenoses, 4D flow velocity measurements showed that one patient had normal velocity profiles in agreement with a previous magnetic resonance angiogram (MRA), while the second showed increased velocities that indicated a less significant narrowing than suspected on a previous MRA, as confirmed by catheter angiography. This result may have prevented an invasive angiogram. In the two patients with 4-mm intracranial aneurysm, one had a stable helical flow pattern with a large jet, while the other had a temporally unstable flow pattern with a more focal jet possibly indicating that the second aneurysm may have a higher likelihood of rupture. Accelerated 4D flow provides time-resolved 3D velocity data in an 8- to 10-min scan. In the stenosis patients, the addition of 4D flow to a traditional MRA adds the velocity data provided from transcranial Doppler ultrasound (TCD) possibly allowing for more accurate grading of stenoses. In the aneurysm patients, visualization of flow patterns may help to provide prognostic information about future risk of rupture.  相似文献   

3.

Purpose

Greater spatial resolution in intracranial three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) is possible at higher field strengths, due to the increased contrast-to-noise ratio (CNR) from the higher signal-to-noise ratio and the improved background suppression. However, at very high fields, spatial resolution is limited in practice by the acquisition time required for sequential phase encoding. In this study, we applied parallel imaging to 7T TOF MRA studies of normal volunteers and patients with vascular disease, in order to obtain very high resolution (0.12 mm3) images within a reasonable scan time.

Materials and Methods

Custom parallel imaging acquisition and reconstruction methods were developed for 7T MRA, based on generalized autocalibrating partially parallel acquisition (GRAPPA). The techniques were compared and applied to studies of seven normal volunteers and three patients with cerebrovascular disease.

Results

The technique produced high resolution studies free from discernible reconstruction artifacts in all subjects and provided excellent depiction of vascular pathology in patients.

Conclusions

7T TOF MRA with parallel imaging is a valuable noninvasive angiographic technique that can attain very high spatial resolution.  相似文献   

4.
We determined whether the accuracy of magnetic resonance angiography (MRA) in the peripheral run-off vessels can be improved by using contrast-enhanced (CE) three-dimensional (3D) technique in comparison to electrocardiograph (ECG)-triggered two-dimensional (2D) time-of-flight (TOF) technique. In a prospective study 20 patients with occlusions of the pelvic and/or femoral arteries underwent a CE 3D MRA (repetition time (TR): 5 ms, (TE) echo time: 2 ms, flip angle (FA): 30°) and an ECG-triggered 2D time-of-flight (TOF) technique (TR: 408 resp. 608 ms, TE: 7 ms, FA: 70°) of the run-off vessels on a 1.5 T MR system. Each patient received a contrast material volume of 0.15 mmol/kg of body weight of gadolinium (Gd)/DTPA using an automatic injector. The tube system to the patient was flushed by 50 mL of a saline solution applied with the same injection rate as the contrast material administration. The start of the 3D MR sequence was tailored individually to the applied contrast material after determination of circulation times by a prior bolus. All patients underwent each conventional or digital arteriography for comparison, as well. The visualization of the run-off vessels was ranked on a scale of 0–3 (0 = poor, 1 = fair, 2 = good, 3 = excellent) by three blinded reviewers. They also graded the vascular segments as either occluded or significantly altered (>50% reduction in diameter) or free of significant stenosis. CE 3D MRA was significantly faster in imaging the run-off vessels in comparison to the ECG-triggered 2D TOF technique. All 160 vascular segments were visualized with the 3D method, whereas only 142/160 segments were seen with 2D technique. The resulting image quality ranking of all vascular segments was significantly higher (p < 0.05) using CE 3D MRA (2.8) than with the 2D TOF technique (2.4). The detection of the stenoses was possible with both techniques. The grading of seven of seven stenoses was correct with 3D method and in five of seven cases with the 2D TOF technique. All vessel occlusions were detected by using both techniques. Small collaterals were visualized in more detail with the CE 3D MR angiography. These data demonstrate an improvement in image quality and accuracy of MRA of the peripheral arteries using a CE 3D technique in comparison to an ECG-triggered 2D TOF sequence.  相似文献   

5.
Renal transplant patients often require imaging to ensure appropriate graft placement, to assess integrity of transplant vessel anastomosis and to evaluate for stenosis that can be a cause of graft failure. Because there is risk for nephrogenic systemic fibrosis in the setting of renal insufficiency, the use of non-contrast MRA in these patients is helpful. In this study, the ability of two non-contrast MRA methods – 3D radial linear combination balanced SSFP (VIPR-SSFP) and inflow-weighted Cartesian SSFP (IFIR) – to visualize the transplant renal vessels is compared. Twenty-one renal transplant patients were scanned using the VIPR-SSFP and IFIR sequences. Diagnostic efficacy of the sequences was scored using a four point Likert scale according to the following criteria: overall image quality, fat suppression, and arterial/venous visualization quality. Average scores for each criterion were compared using the Wilcoxon signed-rank test. In addition to significantly improved venous visualization, the VIPR-SSFP sequence provided significantly improved fat suppression quality (p < 0.03) compared to IFIR. VIPR-SSFP also identified several pathologies such as renal arterial pseudoaneurysm that were not visible on the IFIR images. However, IFIR afforded superior quality of arterial visualization (p < 0.005). These two methods of non-contrast MR imaging each have significant strengths and are complementary to each other in evaluating the vasculature of renal allografts.  相似文献   

6.
Both anatomical and functional scans are often performed when diagnosing renovascular diseases, which in many cases require two separate contrast injections. With nephrogenic systemic fibrosis being associated with gadolinium, minimizing contrast injection dosage is desirable. In this study, a technique which performs time-resolved renal magnetic resonance angiography (MRA) and perfusion with a single scan and single dose of contrast has been evaluated in six healthy volunteers. A previously developed three-dimensional MRA technique called Contrast-enhanced Angiography with Multi-Echo and Radial k-space (CAMERA) has been used to acquire images, and perfusion analysis was performed using deconvolution methods. Time-resolved MRA, as well as renal blood flow, renal volume of distribution and mean transit time maps, were acquired.  相似文献   

7.
In thorax and abdomen imaging, image quality may be affected by breathing motion. Cardiac MR images are typically obtained while the patient holds his or her breath, to avoid respiration-related artifacts. Although useful, breath-holding imposes constraints on scan duration, which in turn limits the achievable resolution and SNR. Longer scan times would be required to improve image quality, and effective strategies are needed to compensate for respiratory motion. A novel approach at respiratory compensation, targeted toward 3D free-breathing cardiac MRI, is presented here. The method aims at suppressing the negative effects of respiratory-induced cardiac motion while capturing the heart's beating motion. The method is designed so that the acquired data can be reconstructed in two different ways: First, a time series of images is reconstructed to quantify and correct for respiratory motion. Then, the corrected data are reconstructed a final time into a cardiac-phase series of images to capture the heart's beating motion. The method was implemented, and initial results are presented. A cardiac-phase series of 3D images, covering the entire heart, was obtained for two free-breathing volunteers. The present method may prove especially useful in situations where breath-holding is not an option, for example, for very sick, mentally impaired or infant patients.  相似文献   

8.
To achieve acceptable scan times, current multiple thin slice and 3D MR angiography (MRA) methods usually are based on continuous data acquisition, without ECG-synchronization. The purpose of this work is to study consequences of pulsatile blood flow for the 2D inflow method. Arterial blood flow and blood signal intensity versus cardiac phase were studied by a 2D phase based method with retrospective cardiac synchronization. Such studies were performed in different parts of the body and with different excitation flip angles. As expected, a clear relation between intensity enhancement and time dependent flow can be demonstrated. The raw data of these multiphase studies was used to simulate alternative inflow MRA data acquisition strategies to improve image quality, without the excessive increase in scan time implied by standard cardiac triggering. The alternatives investigated were data collection during part of the cardiac cycle and cardiac-ordered phase encoding. Simulation results indicate that the best results are obtained by a combination of both strategies. This method was implemented on Philips Gyroscan systems to compare it with standard nontriggered 2D inflow in practical MRA studies. For highly pulsatile flow, much better MR angiograms were obtained in this way.  相似文献   

9.
PurposeComputed tomography (CT) imaging is the standard to assess interstitial lung disease. Magnetic resonance (MR) is potentially advantageous due to superior tissue characterization and better assessment of blood flow dynamics. This study aimed to evaluate idiopathic pulmonary fibrosis (IPF) using prototype 4D Stack of Stars GRE (StarVIBE) MR and compare it to CT.MethodThis IRB-approved prospective study included 13 patients [5F:8M; average age 66 ± 8.1 years] with pulmonary fibrosis, and 12 healthy controls [3F:9M; average age 55 ± 3.6 years]. MR of the chest included noncontrast steady-state free precession imaging (SSFP) and free-breathing 4D StarVIBE sequence with intravenous contrast administration up to 160 s. The images were assessed for quality and artifacts. The image resolution was evaluated based on the visibility of the smallest bronchi, vessels, lymph nodes, and pleural fissures. Independent assessment of reticulation, ground-glass opacity, and traction bronchiectasis was performed and compared to CT.ResultsThe StarVIBE images had fewer artifacts and higher spatial resolution. The findings associated with IPF were significantly better seen with StarVIBE, with superior CT correlation.ConclusionContrast-enhanced free-breathing StarVIBE MR can generate high quality images with good correlation to CT in patients with IPF, and with high spatial and temporal resolution to generate rapid sequential dynamic images.  相似文献   

10.
Contrast-enhanced 3D MR voiding urethrography (CE 3D MRVU) was performed on 5 healthy volunteers and 18 patients with urethral disease. After intravenous injection of 0.3 ml/kg gadolinium, the images of the three consecutive acquisitions of the 3D MRVU technique were obtained during voiding. The raw data were reconstructed on all patients for visual analysis. The image quality of the volunteers was technically sufficient to demonstrate normal urethral anatomy. Contrast-enhanced 3D MR voiding urethrography of the urethral strictures was compared with conventional retrograde urethrography (n = 10) and urethroscopy (n = 12). The urethral pathologies including strictures and other obstructive causes of impaired urethral flow were correctly identified on CE 3D MRVU.  相似文献   

11.
Accurate depiction of the vessels of the lower leg, foot or hand benefits from suppression of bright MR signal from lipid (such as bone marrow) and long-T1 fluid (such as synovial fluid and edema). Signal independence of blood flow velocities, good arterial/muscle contrast and arterial/venous separation are also desirable. The high SNR, short scan times and flow properties of balanced steady-state free precession (SSFP) make it an excellent candidate for flow-independent angiography. In this work, a new magnetization-prepared 3D SSFP sequence for flow-independent peripheral angiography is presented. The technique combines a number of component techniques (phase-sensitive fat detection, inversion recovery, T2-preparation and square-spiral phase-encode ordering) to achieve high-contrast peripheral angiograms at only a modest scan time penalty over simple 3D SSFP. The technique is described in detail, a parameter optimization performed and preliminary results presented achieving high contrast and 1-mm isotropic resolution in a normal foot.  相似文献   

12.
This work compared the performance of four navigator gating algorithms [accept/reject (A/R), diminishing variance algorithm (DVA), phase ordering with automatic window selection (PAWS) and retrospective gating (RETRO)] in suppressing respiratory motion artifacts in free-breathing 3D balanced steady-state free precession coronary MRA. In 10 volunteers, the right coronary artery (RCA) or the left anterior descending artery (LAD) was imaged (both if time permitted) at 1.5 T with the four gating techniques in random order. Vessel signal, vessel contrast and motion suppression were scored by the consensus of two blinded readers. In 15 imaged vessels (nine RCA and six LAD), PAWS provided significantly better image quality than A/R (P<.05), DVA (P=.02) and RETRO (P=.002). While the quality difference between A/R and DVA was not statistically significant, both algorithms yielded significantly better image quality than RETRO. PAWS and DVA were the most efficient algorithms, providing an approximately 20% and 40% relative increase in average navigator efficiency compared to A/R and RETRO, respectively.  相似文献   

13.
14.
Black-blood magnetic resonance angiography (black-blood MRA) could be considered an alternative to time-of-flight (TOF) MRA. In the cases of irregular flow conditions, it could be more advantageous than time-of-flight (TOF) MRA in providing vessel definition and delineation. Proton-density weighted (PDW) multi-slab three-dimensional fast spin-echo (3DFSE) sequences have been used to generate black-blood MRA. Unfortunately, multi-planar reformatted 3DFSE images often exhibit slab boundary artifacts (intensity variation in the slice direction) which create dark bands interfering with the identification of dark blood vessels. Furthermore, PDW measurements fail to darken slow flowing or re-circulating blood in some circumstances. In this work, a dual-contrast multi-slab 3DFSE acquisition is used to approach black-blood MRA. This sequence simultaneously provides proton-density weighted (PDW) and T(2)-weighted (T2W) images which can be further integrated together to produce black-blood angiograms gained by utilizing complementary contrast and supplementary vascular information. Additionally, a technique of suppressing slab boundary artifact has been incorporated into this sequence. This approach provides: i) good SNR measurement of anatomy for the PDW image and optimal black-blood angiograms from the T2W image; ii) scan time efficiency (dual-contrast image sets plus black-blood angiograms within one acquisition); and iii) suppressed slab boundary artifacts as well as minimized mis-registration error.  相似文献   

15.
李律  周赜辰  苑纯  郭华 《波谱学杂志》2016,33(4):528-538
豆纹动脉是大脑内部的重要动脉,其阻塞往往会导致腔隙性脑梗死.现在在临床上主要利用数字减影血管造影(Digital Subtraction Angiography,DSA)技术实现豆纹动脉成像,然而DSA的有创性是其重要的限制因素.有研究表明,在高场磁共振系统(7 T)下,时间飞跃法(Time-Of-Flight,TOF)已经能够得到较好的豆纹动脉影像,但是在临床使用的1.5 T或3 T磁共振系统下,由于豆纹动脉的管腔直径非常小(大约为0.3~0.7 mm)、血流速度比较慢,对其成像仍然是个挑战.该文主要研究了在3 T磁共振系统下使用流动敏感黑血(Flow-Sensitive Black-Blood,FSBB)序列对豆纹动脉进行成像的方法,并对该成像序列中流动敏感梯度的设计进行了优化,使其在扫描时间和图像分辨率、对比度、信噪比等方面都能够基本满足临床使用的要求.  相似文献   

16.
ObjectiveIn this study, we sought to investigate the feasibility of fast carotid artery MR angiography (MRA) by combining three-dimensional time-of-flight (3D TOF) with compressed sensing method (CS-3D TOF).Materials and methodsA pseudo-sequential phase encoding order was developed for CS-3D TOF to generate hyper-intense vessel and suppress background tissues in under-sampled 3D k-space. Seven healthy volunteers and one patient with carotid artery stenosis were recruited for this study. Five sequential CS-3D TOF scans were implemented at 1, 2, 3, 4 and 5-fold acceleration factors for carotid artery MRA. Blood signal-to-tissue ratio (BTR) values for fully-sampled and under-sampled acquisitions were calculated and compared in seven subjects. Blood area (BA) was measured and compared between fully sampled acquisition and each under-sampled one.ResultsThere were no significant differences between the fully-sampled dataset and each under-sampled in BTR comparisons (P > 0.05 for all comparisons). The carotid vessel BAs measured from the images of CS-3D TOF sequences with 2, 3, 4 and 5-fold acceleration scans were all highly correlated with that of the fully-sampled acquisition. The contrast between blood vessels and background tissues of the images at 2 to 5-fold acceleration is comparable to that of fully sampled images. The images at 2 × to 5 × exhibit the comparable lumen definition to the corresponding images at 1 ×.ConclusionBy combining the pseudo-sequential phase encoding order, CS reconstruction, and 3D TOF sequence, this technique provides excellent visualizations for carotid vessel and calcifications in a short scan time. It has the potential to be integrated into current multiple blood contrast imaging protocol.  相似文献   

17.
The aim of this article was to obtain initial experiences with fluoroscopically triggered contrast-enhanced (CE) 3D MR DSA with elliptical centric k-space order and 3D time-of-flight (TOF) turbo MRA of the carotid arteries. In this prospective study we examined 16 consecutive patients with suspicion of atherosclerotic disease involving the carotid arteries. Ultrasound was available in all, x-ray angiography in 12, surgical correlation in 9, and intraoperative x-ray angiography in 4 patients. All examinations were done on a 1.5 T unit applying: transverse plain 3D TOF turbo MRA and coronal CE MRA with fluoroscopic triggering. Combining head and neck array coils allowed the visualization of supraaortic arteries from the aortic arch to the circle of Willis. MRA results (maximum intensity projections) were compared with x-ray angiography, ultrasound, and inspection of endarterectomy specimens. Volume rendering was performed in selected cases additionally. Agreement between CE MRA, 3D TOF turbo MRA and x-ray angiography regarding stenoses of the internal and external carotid artery was very good. CE MRA was able to detect correctly intracranial stenoses, but delineation of the aortic arch and proximal common carotid arteries was sometimes reduced. Volume rendering was suited for visualization of MRA images providing a realistic three-dimensional impression. In conclusion, high-resolution fluoroscopically triggered CE MRA as non-invasive technique is another important step on the way to replace invasive x-ray angiography for the evaluation of atherosclerotic carotid artery disease. High resolution 3D TOF turbo MRA might be a helpful adjunct to increase the diagnostic reliability for the carotid bifurcation.  相似文献   

18.
In order to use MR imaging to assess progression or regression of atherosclerosis, one must have an idea of the reproducibility of the imaging and image processing techniques. The ability of dark-blood MRI and semiautomated image processing to reproducibility measure the inner boundary of the carotid arteries was evaluated and compared with results obtained using bright-blood MRA. MRI and MRA images were obtained for two normal and two diseased volunteers six times each over a short period of time (6 months). The carotid bifurcation was used to align slices from different imaging sessions. The area for each vessel (right and left common, internal and external carotid artery) was determined for the six imaging sessions. The standard deviations of each lumen area normalized to the average area were computed for each vessel segment for each volunteer. For the common, internal, and external carotids, the averaged normalized standard deviations for MRI were 8, 12, and 17% and for MRA were 6, 8, and 13%. Lumen sizes obtained by MRI and MRA were found to be not statistically different. Eccentric plaques not seen on MRA were visualized by MRI. In conclusion, dark-blood MRI with semiautomated image processing yields reliable lumen areas that are in agreement with those obtained by MRA.  相似文献   

19.

Objective

The purpose of this study was to analyze flow patterns in the pulmonary circulation of healthy volunteers by using 4D flow magnetic resonance imaging.

Materials and Methods

The study was approved by the local ethics committee and all subjects gave written informed consent. Eighteen volunteers underwent a 4D flow scan of the whole-heart. Two patients with congenital heart disease were also included to detect possible patterns of flow abnormalities (Patient 1: corrected transposition of great arteries (TGA); Patient 2: partial anomalous pulmonary venous return and atrial septal defect). To analyze flow patterns, 2D planes were placed on the main pulmonary artery (PA), left and right PA. Flow patterns were assessed manually by two independent viewers using vector fields, streamlines and particle traces, and semi-automatically by vorticity quantification.

Results

Two counter-rotating helices were found in the main PA of volunteers. Right-handed helical flow was detected in the right PA of 15 volunteers. Analysis of the helical flow by particles traces revealed that both helices contributed mainly to the flow in the right PA. In the patient with corrected TGA helical flow was not detected. Abnormal vortical flow was visualized in the main PA of patient 2, suggesting elevated mean PA pressure.

Conclusions

Helical flow is normally present in the main PA and right PA. 4D flow is an excellent tool to evaluate noninvasively complex blood flow patterns in the pulmonary circulation. Knowledge of normal and abnormal flow patterns might help to evaluate patients with congenital heart disease adding functional information undetectable with other imaging modalities.  相似文献   

20.

Purpose

To prospectively compare the navigator-echo triggering technique (navigator technique) and the conventional respiratory triggering technique using bellows (bellows technique) for free-breathing three-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP) under clinical conditions.

Materials and methods

Forty patients referred for evaluation of biliary or pancreatic diseases underwent 3D MRCP examination using both navigator and bellows techniques. Two independent radiologists visually evaluated the image quality of 12 segments of the pancreaticobiliary tree in a blinded manner. In addition, the clarity of the lesion was compared between the two techniques in a side-by-side manner.

Result

MRCP images were successfully acquired using both techniques in all patients. No significant difference in acquisition time was found between the two techniques. The image quality was significantly better using the navigator technique than using the bellows technique for the following seven segments: the head, body, and tail of the pancreatic duct; right hepatic duct; anterior and posterior segments of the right hepatic duct; and cystic duct. The other segments (common hepatic and bile duct, left hepatic duct, medial and lateral segments of left hepatic duct, gallbladder) showed no significant difference. The clarity of lesion depiction was significantly better using the navigator technique than using the bellows technique.

Conclusion

Respiratory-triggered 3D MRCP using the navigator technique was shown to be feasible in routine clinical practice. The navigator technique improved the image quality of free-breathing 3D MRCP compared with the bellows technique. The clarity of lesion visualization was also better using the navigator technique than using the bellows technique.  相似文献   