J A Ni  H X Ju  H Y Chen  D Leech 《The Analyst》1998,123(12):2895-2898
A chemically modified graphite electrode was prepared by using a dual film of [Os(bpy)2(PVP)10Cl]Cl polymer and Nafion. The modified electrode showed excellent electrocatalytical activity for the oxidation of norepinephrine (NE) and an ability to eliminate efficiently the interference of ascorbic acid and other anions. The catalytic peak currents obtained from the cyclic voltammograms increased linearly with increasing concentration of NE. A log-log plot of catalytic current versus NE concentration showed a dual-linear relationship in the ranges 1.8 x 10(-8)-4.4 x 10(-6) M and 4.4 x 10(-6)-2.9 x 10(-4) M with correlation coefficients of 0.990 and 0.999, respectively. The detection limit was about 18 nM (3 delta). At a potential of +500 mV the chronoamperometric response showed a linear relationship between the steady state current and NE concentration in the range 1.3-130 microM. With a further increase in NE concentration a Michaelis-Menten-shaped response was observed. The apparent Michaelis-Menten constant and the maximum current were 1.7 mM and 86 microA, respectively. The modified electrode showed excellent reproducibility, sensitivity and stability for the determination of NE at trace levels.  相似文献   

2.
Amidosulfonic acid was electropolymerized by cyclic voltammetry onto the surface of glassy carbon electrode (GCE) to fabricate the chemically modified electrode, which showed high stability, good selectivity and reproducibility for determination of isoniazid. The modified electrode showed an excellent electrocatalytical effect on the oxidation of isoniazid. Under the optimum conditions, there was a good linear relationship between anodic peak current and isoniazid concentration in the range of 5.0 x 10(-8)- 1.0 x 10(-5) M, and a detection limit of 1.0 x 10(-8) M (S/N = 3) was obtained after 120 s at the accumulation potential of - 0.2 V (vs. SCE). This developed method had been applied to the direct determination of isoniazid in injection and tablet samples with satisfactory results.  相似文献   

3.
A sensitive and selective method for the determination of lead(II) with a 1,4-bis(prop-2'-enyloxy)-9,10-anthraquinone (AQ) modified carbon paste electrode has been developed. The method is based on non-electrolytic preconcentration via complex formation with modifier, followed by an accumulation period with a negative potential (-1.5 V), and then by a proper anodic stripping. The analytical performance was evaluated with respect to the quantity of modifier in the paste, concentration of electrolyte solution, preconcentration time, lead(II) concentration, and other variables. A linear calibration graph was obtained in the concentration range 2.00x10(-9)-1.06x10(-5) M Pb(II) (n=21, r=0.9999) with 30 s preconcentration time. The detection limit was found to be 1x10(-9) M. For eight preconcentration/determination cycles, the differential pulse voltammetric response was reproduced with 5.0 and 3.7% relative standard deviations at 2.00x10(-8) and 2.00x10(-6) M Pb(II), respectively. Rapid and convenient renewal of electrode surface allows the use of a single modified electrode surface in multiple analytical determinations over several weeks. Many coexisting metal ions had little or no effect on the determination of lead(II). The developed method was applied to lead determination in waste waters.  相似文献   

4.
Eftekhari A 《Talanta》2001,55(2):395-402
A chemically modified electrode was fabricated based on manganese hexacyanoferrate (MnHCF) film. The MnHCF was used as a modifier immobilized onto an aluminum electrode. Stability of the electroactive film formed on the Al electrode surface indicated that MnHCF is a suitable material for the preparation of modified electrodes. The analytical applicability of the modified electrode for the determination of hydrogen peroxide was examined. A linear response in concentration range of 6.0x10(-7)-7.4x10(-3) M (r=0.9997) was obtained with detection limit of 2.0x10(-7) M for the determination of hydrogen peroxide. The modified electrode exhibited a good selectivity for H(2)O(2) in real samples. The mentioned electrode has advantages of being highly stable, sensitive, inexpensive, ease of construction and use.  相似文献   

5.
Kumar SA  Tang CF  Chen SM 《Talanta》2008,76(5):997-1005
We report a new method for selective determination of acetaminophen (AP) in physiological condition. A new hybrid film modified electrode was fabricated using inorganic semiconducting nano-TiO(2) particles and redox active polymer. Redox polymer, poly(acid yellow 9) (PAY) was electrochemically deposited onto nano-TiO(2) coated glassy carbon (GC) electrode. Surface characterizations of modified electrode were investigated by using atomic force microscope and scanning electron microscope. The PAY/nano-TiO(2)/GC hybrid electrode shows stable redox response in the pH range 1-12 and exhibited excellent electrocatalytic activities towards AP in 0.1M phosphate buffer solution (pH 7.0). Consequently, a simple and sensitive electroanalytical method was developed for the determination of AP. The oxidation peak current was proportional to the concentration of acetaminophen from 1.2 x 10(-5) to 1.20 x 10(-4)M and the detection limit was found to be 2.0 x 10(-6)M (S/N=3). Possible interferences were tested and evaluated that it could be possible to selective detection of AP in the presences of dopamine, nicotinamide adenine dinucleotide (NADH), ascorbic acid and uric acid. The proposed method was used to detect acetaminophen in commercial drugs and the obtained results are satisfactory.  相似文献   

6.
A highly selective poly(vinyl chloride)-based membrane sensor produced by using N,N-diethyl-N-(4-hydroxy-6-methylpyridin-2-yl)guanidine (GD) as active material is described. The electrode displays Nernstian behavior over the concentration range 7.0 x 10(-5) - 1.0 x 10(-1) M. The detection limit of the electrode is 5.0 x 10(-5) M. The best performance was obtained with the membrane containing 30% PVC, 55% benzyl acetate, 5% GD and 10% oleic acid. The response of the sensor is pH-independent in the range of 3.0 - 7.0. The sensor possesses satisfactory reproducibility, fast response time (< 20 s), and specially excellent discriminating ability for Eu(III) ion with respect to the alkali, alkaline earth, transition and heavy metal ions. The membrane sensor was used as an indicator electrode in potentiometric titration of Eu(III) ion with EDTA. It was also applied in determination of fluoride ions in mouth wash preparations.  相似文献   

7.
Zhao H  Zhang Y  Yuan Z 《The Analyst》2001,126(3):358-360
A poly(2-picolinic acid) chemically modified electrode (CME) for the determination of dopamine (DA) by cyclic voltammetry is described. Compared with a bare glassy carbon electrode, the CME exhibits a 200 mV shift of the oxidation potential of DA in the cathodic direction and a marked enhancement of the current response. In pH 7.0 buffer solution, a linear calibration graph is obtained over the range from 2.5 x 10(-7) to 1.0 x 10(-5) mol dm-3 with a correlation coefficient of 0.998. The detection limit is 3.0 x 10(-8) mol dm-3. The modified electrode eliminated efficiently the interference from ascorbic acid (AA) when present in a 150-fold concentration ratio. It also showed excellent stability and reproducibility.  相似文献   

8.
A carbon-paste electrode spiked with 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone was constructed by the incorporation of 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone in a graphite powder silicon oil matrix. It shown by cyclic voltammetry and double potential-step chronoamperometry, which this ferrocene derivative modified a carbon-paste electrode, can catalyze the ascorbic acid oxidation in an aqueous buffered solution. It has been found that under the optimum conditions (pH 7.00), the oxidation of ascorbic acid at the surface of this carbon paste modified electrode occurs at a potential of about 260 mV less positive than that of an unmodified carbon-paste electrode. The catalytic oxidation peak current was linearly dependent on the ascorbic acid concentration, and a linear calibration curve was obtained in the range of 6 x 10(-5) M-7 x 10(-3) M of ascorbic acid with a correlation coefficient of 0.9997. The detection limit (2sigma) was determined to be 6.3 x 10(-5) M. This method was also used for the determination of ascorbic acid in some pharmaceutical samples, such as effervescent tablets, ampoules and multivitamin syrup, by using a standard addition method. The reliability of the method was established by a parallel determination against the official method.  相似文献   

9.
A cobalt(II) tetrakisphenylporphyrin (Co(II)TPP) film modified glassy carbon electrode (Co(II)TPP-GCE) was prepared by just coating Co(II)TPP solution on the surface of the electrode. It can be used for the simultaneous determination of ascorbic acid and uric acid. The anodic peaks of AA and UA can be separated well. Owing to the strongly hydrophobic property of porphyrin, the modified electrode has good stability and long life. The linear range for UA and AA were 2.0 x 10(-6)-1.0 x 10(-4) M and 9.0 x 10(-6)-2.0 x 10(-3) M with detection limits of 5.0 x 10(-7) and 5.0 x 10(-6) M, respectively. Furthermore, metalloporphyrins of other kinds were also used to construct modified electrodes. Their performances were inferior compared with that of the Co(II)TPP modified electrode.  相似文献   

10.
Abbaspour A  Moosavi SM 《Talanta》2002,56(1):91-96
The utility of carbon paste electrode modified with DTPT (3,4-dihydro-4,4,6-trimethyl-2(1H)-pyrimidine thione) for the potentiometric determination of Cu(II) in aqueous medium is demonstrated. The electrode exhibits linear response to Cu(II) over a wide concentration range (9.77x10(-7)-7.6x10(-2)) with Nernstian slope of 30+/-2 mV per decade. It has a response time of about 45 s and can be used for a period of two months with good reproducibility. The detection limit of this electrode was 7.0x10(-7) M. The proposed electrode shows a very good selectivity for Cu(II) over a wide variety of metal ions. This chemically modified carbon paste electrode was successfully used for the determination of Cu(II) in electronics waste sample solution.  相似文献   

11.
A comparative study was made between developed chemically modified carbon paste electrodes and PVC membrane electrodes for the cationic surfactant cetyltrimethylammonium bromide (CTAB). The carbon paste electrode modified with cetyltrimethylammonium-tetrachloropalladate(II) (CTA-TClP) provides a more sensitive and stable device than that shown by electrodes with an inner reference solution. The best performance was obtained by an electrode based on the paste containing 3.6 wt% CTA-TCIP, 1.8 wt% ethylhexadecyldimethylammonium bromide, 37.6 wt% graphite and 57 wt% tricresyl phosphate. The sensor exhibited a Nernstian response for CTAB over a wide concentration range of 3.5 x 10(-7) to 1.0 x 10(-3) M with a detection limit of 2.0 x 10(-7) M between pH 2.7 and 8.2 with a fast response time of 相似文献   

12.
For the purpose of low cost and sensitive electrochemical detection of 17 beta-estradiol (E2), a multi-wall carbon nanotube (MWNT)-Nafion modified electrode was fabricated. The MWNT modified electrode shows enhancement for the anodic peak current of E2 compared with the value obtained using a bare electrode. The anodic peak current measured by square wave voltammetry after 5 min open-circuit accumulation was proportional to the concentration of E2 over the range of 2.5 x 10(-7) to 10 10(-6) M, and a detection limit of 1 x 10(-8) M was obtained.  相似文献   

13.
A carbon paste electrode (CPE) chemically modified with 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone (4-FEPEMCPE) was employed to study the electrocatalytic oxidation of L-cysteine using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry as diagnostic techniques. The diffusion coefficient (D = 7.863 x 10(-6) cm2 s(-1)) of L-cysteine was also estimated using chronoamperometry. The electron-transfer coefficient, alpha (= 0.40), for L-cysteine at the surface of 4-FEPEMCPE was determined using cyclic voltammetry technique. It was found that under an optimum pH (= 7.00), the oxidation of L-cysteine at the surface of such an electrode occurred at a potential of about 350 mV less positive than that of an unmodified CPE. The catalytic oxidation peak currents represented a linear dependence on the L-cysteine concentration. Linear analytical curves were obtained in the ranges of 9.0 x 10(-5) - 4.9 x 10(-3) M and 2.0 x 10(-5) - 2.8 x 10(-3) M of L-cysteine with correlation coefficients of 0.9981 and 0.9982 in cyclic voltammetry and differential pulse voltammetry, respectively. The detection limits (2 sigma) were determined to be 9.9 x 10(-6) M and 5 x 10(-6) M with cyclic voltammetry and differential pulse voltammetry, respectively. The influences of twenty other amino acids, such as glutamine, L-glutamic acid, L-glysine, L-histidine, L-isoleucine, L-leucine, L-arginine hydrochloride, L-aspargine, L-aspartic acid, S-carboxy methyl-L-cysteine, L-methionine, L-phenyl alanine, L-proline, L-serine, L-threonine, L-cystine, cysteamine and gluthathione, on the current response of the sensor were examined. The obtained results did not show any influence on the analytical signal of L-cysteine by these amino acids (except for cysteamine). The method was also used for the selective determination of L-cysteine in patient-blood plasma and some pharmaceutical preparations by using standard addition method.  相似文献   

14.
Wang CH  Chen SM  Wang CM 《The Analyst》2002,127(11):1507-1511
The anodic polymerization of 3-aminophthalhydrazide (luminol) and iron(II) tris 5-aminophenanthroline (Fe(phen-NH2)3(2+)) has been reported in this paper. A bilayer electrode was developed based on these polymers and the ITO conductive glass (denoted ITO[Fe(phen-NH2)3(2+)]luminol electrode). This electrode emitted light (lambdaem: 430 nm) as it was brought into contact with H2O2. At pH 10, the resulting electrochemiluminescence (ECL) showed a linear relationship with the concentration of H2O2 in the range of 10 microM(-1) mM. This bilayer electrode also showed an application potential for the detection of glucose after being further modified with glucose oxidase (denoted ITO[Fe(phen-NH2)3(2+)]luminol]GOx electrode). Although the resulting ECL decayed more rapidly in concentrated glucose solutions (e.g., I M) because of the consumption of luminol during use, the decay became less severe in diluted glucose solutions (e.g., 10 mM). According to the flow injection analysis, a linear relationship existed between the ECL and the concentration of glucose from 10(-5)-10(-3) M at pH 9. The detection limit could reach a level of 5 x 10(-5) M at this pH.  相似文献   

15.
A highly La(III) ion-selective PVC membrane sensor based on N'-(1-pyridin-2-ylmethylene)-2-furohydrazide (NPYFH) as an excellent sensing material was successfully developed. The electrode shows a good selectivity for La(III) ion with respect to most common cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor exhibits a wide linear response with slope of 19.2 +/- 0.6 mV per decade over the concentration range of 1.0 x 10(-6) - 1.0 x 10(-1) M, and a detection limit of 7.0 x 10(-7) M of La(III) ions. The sensor response is independent of pH in the range of 3.5-10.0. The proposed electrode was applied as an indicator electrode in potentiometric titration of La(III) ion with EDTA.  相似文献   

16.
A PVC membrane incorporating p-tert-butyl calix[4]crown with imine units as an ionophore was prepared and used in an ion-selective electrode for the determination of mercury(II) ions. An electrode based on this ionophore showed a good potentiometric response for mercury(II) ions over a wide concentration range of 5.0 x 10(-5) - 1.0 x 10(-1) M with a near-Nernstian slope of 27.3 mV per decade. The detection limit of the electrode was 2.24 x 10(-5) M and the electrode worked well in the pH range of 1.3 - 4.0. The electrode showed a short response time of less than 20 s. The electrode also showed better selectivity for mercury(II) ions over many of the alkali (Na+, -1.69; K+, -1.54), alkaline-earth (Ca2+, -3.30; Ba2+, -3.32), and heavy metal ions (Co2+, -3.67; Ni2+, -3.43; Pb2+, -3.31; Fe3+, -1.82). Ag+ ion was found to be the strongest interfering ion. Also, sharp end points were obtained when the sensor was used as an indicator electrode for the potentiometric titration of mercury(II) ions with iodide and dichromate ions.  相似文献   

17.
A sensitive adsorptive stripping voltammetric method for the determination of dinitrophenolic herbicides, dinoseb (DSB) and dinoterb (DTB) at a bare carbon paste electrode (CPE) and a clay modified carbon paste electrode (CMCPE) was developed. A systematic study of various experimental conditions, such as the pH, accumulation variables and composition of a modifier on the adsorptive stripping response, were examined by using differential pulse voltammetry. A significant improvement was observed in the sensitivity by using the present method with CMCPE. When CMCPE was used, a linear response was obtained over the concentration range 2 x 10(-10) to 3 x 10(-7) M and 6 x 10(-10) to 6 x 10(-7) M with lower detection limits of 1 x 10(-10) M and 5.4 x 10(-10) M for dinoseb and dinoterb, respectively, at an accumulation time of 100 s. The interference from other herbicides and ions on the stripping signals of both compounds was also evaluated. The described method was applied to estimate of the dinoseb and dinoterb in environmental samples.  相似文献   

18.
A novel hydrogen peroxide biosensor was developed based on the immobilization of horseradish peroxidase (HRP) in a TiO(2) sol-gel matrix on an electropolymerized phenazine methosulfate (PMS) modified electrode surface. Such membranes are of interest due to their high surface area, biological compatibility, and ease of fabrication. HRP entrapped in the TiO(2) matix was stable and retained its activity to a large extent. Cyclic voltammetry and amperometric measurements were employed to demonstrate the feasibility of electron transfer between immobilized HRP and the glassy carbon electrode via electropolymerized PMS. The influence of various experimental parameters such as operating potential, pH, temperature, and stability was investigated for optimum analytical performance. The biosensor provided a wide linear calibration range from 4.0x10(-6) M to 1.0x10(-3) M, with a detection limit of 8.0x10(-7) M at a signal-to-noise ratio of 3. The sensor retained 80% of its original activity after two months of operation.  相似文献   

19.
A Pd/IrO(2) co-electrodeposited glassy carbon electrode was prepared and the electrochemical behavior of glutathione (GSH) at this chemically modified electrode (CME) has been studied by cyclic voltammetry (CV). The results indicated that the modified electrode efficiently exhibited electrocatalytic oxidation for GSH with relatively high sensitivity, stability, and long-life. Coupled with high-performance liquid chromatography (HPLC), the Pd/IrO(2) modified electrode was utilized for the electrochemical detection (ECD) of the thiocompounds, glutathione and cysteine (Cys). The peak currents were linear with the substance concentrations in the range of 1.0 x 10(-5) mol L(-1) to 8.0 x 10(-4) mol L(-1) for GSH and 4.0 x 10(-6) mol L(-1) to 2.0 x 10(-4) mol L(-1) for Cys. The detection limits were 2.0 x 10(-6) mol L(-1) for GSH and 5.0 x 10(-7) mol L(-1) for Cys with S/N of 3. The method has been successfully applied to assess the contents of GSH and Cys in rat brain microdialysates.  相似文献   

20.
Electrocatalytic oxidation of ascorbic acid (AA) at a carbon paste electrode, chemically modified 2,2'-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone, was thoroughly investigated. The results of cyclic voltammetry, double potential-step chronoamperometry, linear sweep voltammetry and differential pulse voltammetry (DPV) studies were used for the prediction of the mechanism of electrochemical oxidation of AA mediated with 2,2'-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone at the surface of the modified electrode. The diffusion coefficient (D = 2.45 x 10(-5) cm(2) s(-1)) and the kinetic parameters such as the electron transfer coefficient (alpha = 0.34) were also determined. The results of DPV using the 2,2'-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone-modified electrode were applied in a highly sensitive determination of AA in drug samples. A linear range of 3.0 x 10(-6) - 1.2 x 10(-4) M and the detection limit (3sigma) 3.8 x 10(-7) M were obtained for DPV determination of AA in buffered pH 7.00 solutions (0.1 M phosphate buffer).  相似文献   