 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid linear ion trap Fourier transform ion cyclotron resonance mass spectrometer (ESI-LTQ-FT-ICR-MS). A solution of fluorescent dye was electrosprayed with a stainless steel mesh screen placed in front of the MS inlet capillary acting as a gas-permeable imaging plate for fluorescence spectroscopy. Without use of the air amplifier, no detectable FT-ICR signal was observed, as well as no detectable fluorescence on the screen upon imaging using a fluorescence scanner. When the air amplifier was turned ON while electrospraying the fluorescent dye, FT-ICR mass spectra with high signal to noise ratio were obtained with an average ion injection time of 21 ms for an AGC target value of 5 x 10(5). Imaging of the screen using a fluorescence scanner produced a distinct spot of cross-sectional area approximately 33.5 mm(2) in front of the MS inlet capillary. These experimental results provide direct evidence of aerodynamic focusing of electrosprayed droplets/ions enabled by an air amplifier, resulting in improved electrospray droplet/ion capture efficiency and reduced ion injection time. A second set of experiments was carried out to explore whether the air amplifier assists in desolvation. By electrospraying a mix of quaternary amines, ratios of increasingly hydrophobic molecules were obtained. Observation of the solvophobic effect associated with electrospray ionization resulted in a higher abundance of the hydrophobic molecule. This bias was eliminated when the air amplifier was turned ON and a response indicative of the respective component concentrations of the molecules in the bulk solution was observed.  相似文献   

2.
A new electrospray source design is introduced by having an extractor electrode placed at 1 to 2 mm behind the emitter tip. The extractor was integrated into the sprayer body as a single device. An insulating tube was used to isolate the emitter from the extractor and to deliver the sheath gas for the electrospray. The electric field strength at the emitter was primarily determined by the relative position and the potential between the needle and the extractor; therefore, the spraying condition was insusceptible to the change of sprayer position or orientation with respect to the ion sampling inlet. Such design allowed the use of much lower operating voltage and facilitated the optimization of sprayer position by keeping the electric field parameter constant. Using an emitter capillary of 150 and 310 μm in inner and outer diameters, strong ion signal could still be acquired with 2‐kV emitter potential even if the distance between the emitter and ion inlet was extended to >70 mm. Charge reduction of protein ions using 2 extractor‐based electrosprays of opposite emitter polarities was also demonstrated.  相似文献   

3.
Negative ion mode nano-ESI–MS is often considered for the analysis of acidic compounds, including nucleotides. However, under high aqueous separation conditions, corona discharge is frequently observed at emitter tips, which may result in low ion abundances and reduced nano-ESI needle emitter lifetimes. In this work, we introduce a sheathless CE-MS method for the highly efficient and sensitive analysis of nucleotides employing ESI in positive ion mode, thereby fully circumventing corona discharge. By using a background electrolyte of 16 mM ammonium acetate (pH 9.7) a mixture of 12 nucleotides, composed of mono-, di-, and tri-phosphates, could be efficiently analyzed with plate numbers per meter above 220 000 and with LODs in the range from 0.06 to 1.3 nM, corresponding to 0.4 to 8.6 attomole, when using an injection volume of about 6.5 nL only. The utility of the method was demonstrated for the profiling of nucleotides in low numbers of mammalian cells using HepG2 cells as a model system. Endogenous nucleotides could be efficiently analyzed in extracts from 50 000 down to 500 HepG2 cells only. Moreover, apart from nucleotides, also some nicotinamide-adenine dinucleotides and amino acids could be analyzed under these conditions, thereby clearly illustrating the utility of this approach for metabolic profiling of low amounts of biological material.  相似文献   

4.
The advent of nano-electrospray ionization (nano-ESI) has considerably extended the usability of ESI in the analytical mass spectrometric laboratory. One of the remarkable features of nano-ESI is its extremely low sample consumption. Only a few microliters of analyte solution (10(-5)-10(-8) M) are sufficient for molecular weight determination and structural investigations by MS/MS. But nano-ESI is more than just a minimized-flow ESI; the low solvent flow rate also affects the mechanism of ion formation. As a consequence, the area of ESI-MS applications is significantly enhanced. Oligosaccharides, glycosides as well as glycoproteins can be analyzed more easily than with normal ion spray. The same holds for the analysis of non-covalent complexes sprayed directly from aqueous solutions.  相似文献   

5.
The advent of nano-electrospray ionization (nano-ESI) has considerably extended the usability of ESI in the analytical mass spectrometric laboratory. One of the remarkable features of nano-ESI is its extremely low sample consumption. Only a few microliters of analyte solution (10–5–10–8 M) are sufficient for molecular weight determination and structural investigations by MS/MS. But nano-ESI is more than just a minimized-flow ESI; the low solvent flow rate also affects the mechanism of ion formation. As a consequence, the area of ESI-MS applications is significantly enhanced. Oligosaccharides, glycosides as well as glycoproteins can be analyzed more easily than with normal ion spray. The same holds for the analysis of non-covalent complexes sprayed directly from aqueous solutions.  相似文献   

6.
This article describes a means of sampling ions that are created at a location remote from the primary ion source used for mass spectral analysis. Such a source can be used for delivery of calibrant ions on demand. Calibrant ions are sprayed into an atmospheric pressure chamber, at a position substantially removed from the sampling inlet. A gas flow sweeps the calibrants towards the sampling inlet, and a new means for toggling the second ion beam into the instrument can be achieved with the use of a repelling field established by an electrode in front of the sampling inlet. The physical separation of two or more sources of ions eliminates detrimental interactions due to gas flows or fields. When using a nanoflow electrospray tip as the primary ion source, the potential applied to the tip completely repels calibrant ions and there is no compromise in terms of electrospray performance. When calibrant ions are desired, the potential applied to the nanoflow electrospray tip is lowered for a short period of time to allow calibrant ions to be sampled into the instrument, thus providing a means for external calibration that avoids the typical complications and compromises associated with dual spray sources. It is also possible to simultaneously sample ions from multiple ion beams if necessary for internal mass calibration purposes. This method of transporting additional ion beams to a sampling inlet can also be used with different types of atmospheric pressure sources such as AP MALDI, as well as sources configured to deliver ions of different polarity.  相似文献   

7.
Ion funnel is a new-style ion guider which can reduce spatial divergence and energy dispersity of the transmission ions by using radio frequency (RF) electric field to confine the ions radially and the direct current (DC) axial electric field to move the ions toward the exit, and thus it can greatly increase the ion transmission efficiency and improve the sensitivity of the mass spectrometry. Since ion funnel was invented in 1997, it has attracted a close attention of mass spectrometry scientists all over the world. Ion funnel has been used in various kinds of mass spectrometry, and built a bridge with high efficiency ion transmission between low vacuum ionization source and high vacuum mass analyzer. In this paper, the principle, technology development, and application progress of ion funnel are reviewed, and the future prospects are prospected.  相似文献   

8.
The mechanism of atmospheric pressure (AP) laser ionization of water and water/glycerol liquid samples at a 3-microm wavelength is studied experimentally. For the ion desorption, an in-house built Yb : YAG-pumped optical parametric oscillator (OPO) infrared (IR) laser has been coupled with AP MALDI ion source interfaced to an ion trap mass spectrometer (MS). It has been shown that water is primarily responsible for ion generation in water/glycerol samples, while glycerol increases the solution viscosity and decreases the water evaporation rate and sample losses. In contrast to AP UV-MALDI, the electric field in the case of AP IR-MALDI does not assist in ion production. It was found that the absence of the electrical field provides the optimum ionization condition both for water and water/glycerol liquid samples at the 3-microm laser irradiation. A two-stage ion formation mechanism, which includes the initial emission of microdroplets and release of molecular ions at the second stage, can explain the experimentally observed ion signal dependencies upon the voltage applied between MS inlet and the MALDI sample plate. Postionization using additional corona discharge APCI increases the observed signal by approximately 50%, which indicates that some portion of the analyte is desorbed in the form of neutral molecules.  相似文献   

9.
A position sensitive pixel-based detector array, referred to as the IonCCD, has been employed to characterize the ion optics and ion beam focusing in a custom built mass spectrometer designed for soft and reactive landing of mass-selected ions onto surfaces. The IonCCD was placed at several stages along the path of the ion beam to determine the focusing capabilities of the various ion optics, which include an electrodynamic ion funnel, two radiofrequency (rf)-only collision quadrupoles, a mass resolving quadrupole, a quadrupole bender, and two einzel lens assemblies. The focusing capabilities of the rf-only collision quadrupoles and einzel lenses are demonstrated by large decreases in the diameter of the ion beam. In contrast, the mass resolving quadrupole is shown to significantly defocus the mass-selected ion beam resulting in an expansion of the measured ion beam diameter. Combined with SIMION simulations, we demonstrate that the IonCCD can identify minor errors in the alignment of charged-particle optics that result in erratic trajectories and significant deflections of the ion beam. This information may be used to facilitate the design, assembly, and maintenance of custom-built mass spectrometry instrumentation.  相似文献   

10.
A novel Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer has been developed for improved biomolecule analysis. A flared metal capillary and an electrodynamic ion funnel were installed in the source region of the instrument for improved ion transmission. The transfer quadrupole is divided into 19 segments, with the capacity for independent control of DC voltage biases for each segment. Restrained ion population transfer (RIPT) is used to transfer ions from the ion accumulation region to the ICR cell. The RIPT ion guide reduces mass discrimination that occurs as a result of time-of-flight effects associated with gated trapping. Increasing the number of applied DC bias voltages from 8 to 18 increases the number of ions that are effectively trapped in the ICR cell. The RIPT ion guide with a novel voltage profile applied during ion transfer provides a 3- to 4-fold increase in the number of ions that are trapped in the ICR cell compared with gated trapping for the same ion accumulation time period. A novel ICR cell was incorporated in the instrument to reduce radial electric field variation for ions with different z-axis oscillation amplitudes. With the ICR cell, called trapping ring electrode cell (TREC), we can tailor the shape of the trapping electric fields to reduce dephasing of coherent cyclotron motion of an excited ion packet. With TREC, nearly an order of magnitude increase in sensitivity is observed. The performance of the instrument with the combination of RIPT, TREC, flared inlet, and ion funnel is presented.  相似文献   

11.
Miniature mass spectrometer is more compact and portable than traditional commercial mass spectrometry, with more potential for application outside the laboratory. However, a miniature mass spectrometer is less sensitive than a commercial instrument, limiting its application scenarios. The ion transmission efficiency of the instrument is an essential factor affecting the sensitivity. Still, there are few works of literature on the quantitative study of the ion transmission efficiency of each component from a systematic perspective. In this paper, the Faraday cup coupled with a microcurrent signal testing instrument was used to measure the ions generated by nanoelectrospray ionization (nano-ESI), which have successfully gone through several components. Then the ion transmission efficiency of each component was quantified. Results showed that the front lens had the highest ion transmission efficiency of 39.7%, whereas the inlet and skimmer had the lowest ion transfer efficiency of 0.8% and 17.1%. Next, the influence of control parameters on ion transmission efficiency of critical components was investigated. If optimized, the ion funnel and the skimmer had the potential to improve their transmission efficiency by 120% and 79%, respectively. This paper shows the decreasing intensity distribution of ions in the whole transmission process and the transmission efficiency of each component, which can guide for improving the sensitivity of the miniature mass spectrometer.  相似文献   

12.
Concentration sensitivity is a key performance indicator for analytical techniques including for capillary electrophoresis-mass spectrometry (CE–MS) with electrospray ionization (ESI). In this study, a flow-through microvial interface was used to couple CE with MS and improve the ESI stability and detection sensitivity. By infusing a peptide mixture through the interface into an MS detector at a typical flow rate for CE-MS analysis, the spatial region near the interface was mapped for MS signal intensity. When the sprayer tip was within a 6 × 6.5 × 5 mm region in front of the MS inlet, the ESI was stable with no significant loss of signal intensity for ions with m/z 239. Finite element simulations showed that the average electric field strength at the emitter tip did not change significantly with minor changes in emitter tip location. Experiments were conducted with four different mass spectrometer platforms coupled to CE via the flow-through microvial interface. Key performance indicators, that is, limit of detection (LOD) and linearity of calibration curves were measured for nine amino acids and five peptides. Inter- and intraday reproducibility were also tested. The results were shown to be suitable for quantification when internal standards were used.  相似文献   

13.
The ionization and transmission efficiencies of an electrospray ionization (ESI) interface were investigated to advance the understanding of how these factors affect mass spectrometry (MS) sensitivity. In addition, the effects of the ES emitter distance to the inlet, solution flow rate, and inlet temperature were characterized. Quantitative measurements of ES current loss throughout the ESI interface were accomplished by electrically isolating the front surface of the interface from the inner wall of the heated inlet capillary, enabling losses on the two surfaces to be distinguished. In addition, the ES current lost to the front surface of the ESI interface was spatially profiled with a linear array of 340-microm-diameter electrodes placed adjacent to the inlet capillary entrance. Current transmitted as gas-phase ions was differentiated from charged droplets and solvent clusters by measuring sensitivity with a single quadrupole mass spectrometer. The study revealed a large sampling efficiency into the inlet capillary (>90% at an emitter distance of 1 mm), a global rather than a local gas dynamic effect on the shape of the ES plume resulting from the gas flow conductance limit of the inlet capillary, a large (>80%) loss of analyte ions after transmission through the inlet arising from incomplete desolvation at a solution flow rate of 1.0 microL/min, and a decrease in analyte ions peak intensity at lower temperatures, despite a large increase in ES current transmission efficiency.  相似文献   

14.
Mass analysis of air sensitive samples like organometallic catalysts requires inert sample preparation to avoid degradation of such reactive molecules. Non-polar samples like hydrocarbons are stable but nonetheless need soft ionization to reduce congestion of fragment peaks for analysis of complex mixtures. This paper describes a novel type of probe that combines the advantages of field ionization and field desorption (FI/FD) with an efficient liquid inlet. The new method is called Liquid Injection Field Desorption Ionization (LIFDI). Sample solutions are delivered to the emitter wire inside of the ion source without breaking the vacuum. Sample preparation is reduced to dipping the LIFDI transfer capillary into another sample vial. In case of air sensitive samples kept under inert gas, the preparation is inert without special experimental effort. The new tool provides for a significantly raised sample throughput at excellent sensitivity.  相似文献   

15.
Mao X  Chu IK  Lin B 《Electrophoresis》2006,27(24):5059-5067
Microchip was coupled with MS through a stable, sensitive, and controllable sheath-flow nanoelectrospray (nES) interface for glycoprotein and glycopeptide analysis. The nano-ESI (nESI) was made with a delivery capillary, a commercial nES capillary, and a stainless steel (SS) tube which were connected together through a tee unit. High voltage for nES was applied on the SS tube and the commercial nES capillary was used as nES emitter. The delivery capillary was attached to the microchannel for delivering liquid from microchip to the nESI source. The flow rate of sheath liquid was optimized to be 100-200 nL/min which largely reduced the sample dilution. The detection limit of peptides on this microchip/MS platform was at femtomole level. Glycoprotein and glycopeptides were also successfully analyzed on the platform. All the glycoforms and glycopeptides of ribonuclease B (RNase B) were identified with this method. Some structures of the glycopeptides from RNase B were further characterized with MS/MS on the microchip, coupled with a quadrupole IT-MS.  相似文献   

16.
We report on the use of a jet disrupter electrode in an electrodynamic ion funnel as an electronic valve to regulate the intensity of the ion beam transmitted through the interface of a mass spectrometer in order to perform automatic gain control (AGC). The ion flux is determined by either directly detecting the ion current on the conductance limiting orifice of the ion funnel or using a short mass spectrometry acquisition. Based upon the ion flux intensity, the voltage of the jet disrupter is adjusted to alter the transmission efficiency of the ion funnel to provide a desired ion population to the mass analyzer. Ion beam regulation by an ion funnel is shown to provide control to within a few percent of a targeted ion intensity or abundance. The utility of ion funnel AGC was evaluated using a protein tryptic digest analyzed with liquid chromatography Fourier transform ion cyclotron resonance (LC-FTICR) mass spectrometry. The ion population in the ICR cell was accurately controlled to selected levels, which improved data quality and provided better mass measurement accuracy.  相似文献   

17.
Standard field desorption (FD) ionization is implemented under high vacuum condition. In this paper, non‐vacuum FD is performed under a super‐atmospheric pressure environment using untreated tungsten wires as FD emitter, and the ion source was coupled to a commercial linear ion trap mass spectrometer. The operating pressure of the ion source was 6 bars which was high enough to provide sufficient dielectric strength to the working gas so that the high voltage that was required for FD could be applied to the emitter without occurrence of electrical discharge. Non‐volatile sample deposited on the bare tungsten wire FD emitter was heated by flowing direct current through the emitter. Similar to vacuum FD, the formation of conical protrusion of the liquefied sample layer under the strong electric field was also observed. Using the present ion source, high pressure field‐desorption of polar neutral compounds, organic salts and ionic liquids is demonstrated. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification because of the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet.
Figure
?  相似文献   

19.
We report on a new electrodynamic ion funnel that operates at a pressure of 30 torr with no loss of ion transmission. The enhanced performance compared with previous ion funnel designs optimized for pressures of <5 torr was achieved by reducing the ion funnel capacitance and increasing the RF drive frequency (1.7 MHz) and amplitude (100-170 V peak-to-peak). No degradation of ion transmission was observed for pressures from 2 to 30 torr. The ability to operate at higher pressure enabled a new tandem ion funnel mass spectrometer interface design that can accommodate a greater gas load (e.g., from an ESI source). When combined with a multicapillary inlet, the interface provided more efficient introduction of ions, resulting in a significant enhancement in mass spectrometer sensitivity and detection limits.  相似文献   

20.
Enhancements to the ion source and transfer optics of our 9.4 T Fourier transform ion cyclotron resonance (ICR) mass spectrometer have resulted in improved ion transmission efficiency for more sensitive mass measurement of complex mixtures at the MS and MS/MS levels. The tube lens/skimmer has been replaced by a dual ion funnel and the following octopole by a quadrupole for reduced ion cloud radial expansion before transmission into a mass‐selective quadrupole. The number of ions that reach the ICR cell is increased by an order of magnitude for the funnel/quadrupole relative to the tube lens/skimmer/octopole. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   