首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This review describes the different steps involved in the determination of arsenic in air, considering the particulate matter (PM) and the gaseous phase. The review focuses on sampling, sample preparation and instrumental analytical techniques for both total arsenic determination and speciation analysis. The origin, concentration and legislation concerning arsenic in ambient air are also considered. The review intends to describe the procedures for sample collection of total suspended particles (TSP) or particles with a certain diameter expressed in microns (e.g. PM10 and PM2.5), or the collection of the gaseous phase containing gaseous arsenic species. Sample digestion of the collecting media for PM is described, indicating proposed and established procedures that use acids or mixtures of acids aided with different heating procedures. The detection techniques are summarized and compared (ICP-MS, ICP-OES and ET-AAS), as well those techniques capable of direct analysis of the solid sample (PIXE, INAA and XRF). The studies about speciation in PM are also discussed, considering the initial works that employed a cold trap in combination with atomic spectroscopy detectors, or the more recent studies based on chromatography (GC or HPLC) combined with atomic or mass detectors (AFS, ICP-MS and MS). Further trends and challenges about determination of As in air are also addressed.  相似文献   

2.
Post-column photochemical reaction systems have developed into a common approach for enhancing conventional methods of detection in HPLC. Photochemical reactions as a means of ‘derivatization’ have a significant number of advantages over chemical reaction-based methods, and a significant effort has been demonstrated to develop an efficient photochemical reactor. When coupled to electrochemical (EC) detection, the technique allows for the sensitive and selective determination of a variety of compounds (e.g., organic nitro explosives, beta-lactam antibiotics, sulfur-containing antibiotics, pesticides and insecticides). This review will focus on developments and methods using post-column photochemical reaction systems followed by EC detection in liquid chromatography. Papers are presented in chronological order to emphasize the evolution of the approach and continued importance of the application.  相似文献   

3.
4.
Liquid–liquid extraction (LLE) is widely used as a pre-treatment technique for separation and preconcentration of both organic and inorganic analytes from aqueous samples. Nevertheless, it has several drawbacks, such as emulsion formation or the use of large volumes of solvents, which makes LLE expensive and labour intensive. Therefore, miniaturization of conventional liquid–liquid extraction is needed. The search for alternatives to the conventional LLE using negligible volumes of extractant and the minimum number of steps has driven the development of three new miniaturized methodologies, i.e. single-drop microextraction (SDME), hollow fibre liquid-phase microextraction (HF-LPME) and dispersive liquid–liquid microextraction (DLLME). The aim of this paper is to provide an overview of these novel preconcentration approaches and their potential use in analytical labs involved in inorganic (ultra)trace analysis and speciation. Relevant applications to the determination of metal ions, metalloids, organometals and non-metals are included.  相似文献   

5.
A simple and cost-effective method for speciation analysis of trace mercury in seafood was developed by on-line coupling flow injection microcolumn displacement sorption preconcentration to high-performance liquid chromatography (HPLC) with UV detection. The methodology involved the presorption of the Cu-PDC (pyrrolidine dithiocarbamate) chelate onto a microcolumn packed with a cigarette filter sorbent, simultaneous preconcentration of Hg(II), methylmercury (MeHg), ethylmercury (EtHg), and phenylmercury (PhHg) onto the microcolumn through a displacement reaction with the presorbed Cu-PDC, and their subsequent elution from the microcolumn for on-line HPLC separation. Interferences from heavy metal ions with lower stability of their PDC chelates relative to Cu-PDC were minimized without the need of any masking agents. With the consumption of 4.0 ml of sample solution, the enrichment factors were about 80. The detection limits were 10-25 ng g(-1) (as Hg) in fresh tissue. Precision (R.S.D. (%), n = 5) ranged from 2 to 3% at the 500 microg l(-1) (as Hg) level. The developed technique was validated by analyzing a certified reference material (DORM-2, dogfish-muscle), and was shown to be useful for mercury speciation in real seafood samples.  相似文献   

6.
Dias AC  Borges EP  Zagatto EA  Worsfold PJ 《Talanta》2006,68(4):1076-1082
The Schlieren effect is a consequence of light inflexions altering the spectrophotometric measurements that are due to the formation of optical artefacts such as mirror and lenses inside the flowing sample. It may influence signal-to-noise ratio, sample throughput and measurement repeatability in spectrophotometric flow-based procedures. It was critically examined, in order to provide guidelines for system design. Results demonstrate that the magnitude of the Schlieren effect is governed by the combined influence of two components. The first is related to loss of light by reflection at sharp liquid interfaces and prevails under poor mixing conditions. In this situation the transmitted light becomes more intense and somewhat erratic. The second is related to light refraction in regions with pronounced refractive index gradients, and prevails under good mixing conditions. It can lead to positive or negative modifications of the transmitted light, the direction being dependent on the relevance of these components. The importance of the solubility of the chemical species involved, the possibility of interactions with the inner wall of the tubing, and the feasibility of dual-wavelength spectrophotometry for compensating purposes are discussed.  相似文献   

7.
A comprehensive review is presented addressing recent trends in the speciation and determination of vanadium in environmental and biological sample matrices, including important analytical aspects such as sample clean up, pre-concentration and method development. Methodology based on both separation and spectroscopic techniques for the determination of vanadium speciation is discussed. A brief outline of analytical principles, together with an overview of the recent developments and applications of vanadium speciation determination is included. The newer methods for detecting metal ions including hyphenated spectroscopic techniques and sample preparation schemes are also discussed.  相似文献   

8.
This review summarises current knowledge on Hg species and their distribution in the hydrosphere and gives typical concentration ranges in open ocean, coastal and estuarine waters, as well as in rivers, lakes, rain and ground waters. The importance of reliable methods for the determination of Hg species in natural waters and the analytical challenges associated with them are discussed. Approaches for sample collection and storage, pre-concentration, separation, and detection are critically compared. The review covers well established methods for total mercury determination and identifies new approaches that offer advantages such as ease of use and reduced risk of contamination. Pre-concentration and separation techniques for Hg speciation are divided into chromatographic and non-chromatographic methods. Derivatisation methods and the coupling of pre-concentration and/or separation methods to suitable detection techniques are also discussed. Techniques for sample pre-treatment, pre-concentration, separation, and quantification of Hg species, together with examples of total Hg determination and Hg speciation analysis in different natural (non-spiked) waters are summarised in tables, with a focus on applications from the last decade.  相似文献   

9.
Gallignani M  Brunetto Mdel R 《Talanta》2004,64(5):1127-1146
Flow analysis offers an inexpensive and versatile means for the automation of analytical procedures and hence it has been incorporated in many different techniques. However, the use of infrared detection in flow analysis systems is not common. Whereas Fourier transform infrared (FTIR) spectroscopic detection has been routinely used in gas chromatography (GC), its use for liquid chromatography, and now for flow analysis, flow injection analysis, or sequential injection analysis, is not frequent. The most prominent reasons are probably: (i) the strong absorption of most of the common solvents, specially water, (ii) the relative poor sensibility compared to UV–vis, fluorescence, etc. (iii) FTIR is normally not even considered a valuable detection technique, (iv) problems arising from obtaining adequate information from transient IR signals from the injected samples, and (v) only a few analytical chemist uses routinely the FTIR technique. This practice neglects that IR spectroscopy offers some unique features that now, using modern FTIR instrumentation, can be exploited in an advantageous manner. It is important to realize that each sample (analyte/matrix) represents a special and unique analytical problem; which defines the mode of operation and implementation of the IR technique. Flow analysis–IR techniques – as well as all techniques – has a number of shortcomings to solve these problems. In this article, most of these strategies such as the use of: baseline correction, derivative spectroscopy, stopped flow systems, reverse flow systems, multiparametric calibrations, etc., will be discussed. Additionally, recent developments in on-line gas phase generation–FTIR and hydride generation–FTIR spectrometry, as well as the principles of the HPLC–FTIR and capillary electrophoresis–FTIR hyphenation are also discussed. This review aims to provide an account of the state of the art, of these relatively new techniques. Its beginning, developments, applications and new trends, basically in the MID–IR, and by using transmission cells.  相似文献   

10.
Nanoparticles (NPs) exhibit a number of distinctive and entrancing properties that explain their ever increasing application in analytical chemistry, mainly as chemosensors, signaling tags, catalysts, analytical signal enhancers, reactive species generators, analyte recognition and scavenging/separation entities.  相似文献   

11.
An overview of the combination of liquid-phase microextraction (LPME) techniques with graphite furnace atomic absorption spectrometry (GFAAS) is reported herein. The high sensitivity of GFAAS is significantly enhanced by its association with a variety of miniaturized solvent extraction approaches. LPME-GFAAS thus represents a powerful combination for determination of metals, metalloids and organometallic compounds at (ultra)trace level. Different LPME modes used with GFAAS are briefly described, and the experimental parameters that show an impact in those microextraction processes are discussed. Special attention is paid to those parameters affecting GFAAS analysis. Main issues found when coupling LPME and GFAAS, as well as those strategies reported in the literature to solve them, are summarized. Relevant applications published on the topic so far are included.  相似文献   

12.
Multi-pumping flow systems exploit pulsed flows delivered by solenoid pumps. Their improved performance rely on the enhanced radial mass transport inherent to the pulsed flow, which is a consequence of the establishment of vortices thus a tendency towards turbulent mixing.This paper presents several evidences of turbulent mixing in relation to pulsed flows, such as recorded peak shape, establishment of fluidized beds, exploitation of flow reversal, implementation of relatively slow chemical reactions and/or heating of the reaction medium. In addition, Reynolds number associated with the GO period of a pulsed flow is estimated and photographic images of dispersing samples flowing under laminar regime and pulsed flow conditions are presented.  相似文献   

13.
Oguma K  Yoshioka O 《Talanta》2002,58(6):1077-1087
The flow injection analysis systems have been developed for the simultaneous determination of iron(III) and copper(II) and of iron(III) and palladium(II) based on the photochemical reactions of their thiocyanato-complexes. In the first system, a sample solution was injected in to nitric acid solution and mixed with ammonium thiocyanate solution, followed by spectrophotometric monitoring of the thiocyanato-complexes formed. Another aliquot of the same sample solution was injected and the thiocyanato-complexes formed in the same way were irradiated by UV light before spectrophotometric monitoring. In another system, the absorbance of thiocyanato-complexes formed by each sample injection was monitored with two flow cells aligned with the same optical path before and after UV irradiation. The difference in the extent of photochemical decomposition of the thiocyanato-complexes enabled simultaneous determinations of iron(III) and copper(II) and of iron(III) and palladium(II) at levels of several μg ml−1 to some tens μg ml−1 in their admixtures. Sample throughputs are 40 and 20 h−1 by the former and latter systems, respectively.  相似文献   

14.
In the past decade, the lab-on-valve (LOV) system, as the third-generation of the flow-injection analysis technique, has exhibited powerful capability in instrument miniaturization and on-line sample pretreatment.This review presents and discusses the state of the art in the progress of the LOV system in the determination of metal species in two parts:
miniaturization of analytical instrumentations; and,
sample-processing front-ends.
As a miniaturized analytical set-up, LOV incorporates detection techniques for the determination of metal species (e.g., spectrophotometry, electrochemical detection and atomic spectrometry). However, coupling LOV sample pretreatment with atomic or mass spectrometric detectors provides high-sensitivity determination or speciation of metal species.We also discuss future perspectives of the LOV system in metal determination and/or speciation.  相似文献   

15.
Only two computer-controlled microsolenoid devices, namely two micropumps or one micropump and one microvalve, are sufficient for the construction of on-line dilution modules useful in several flow analytical systems for the calibration using single standard. Three simple constructions of such modules were tested and compared. The most promising is the one based on the concept of a microvalve controlling dilution ratio of the standard and a solenoid micropump playing a double role: solution pumping device and mixing segments homogenizer. All investigated modules were tested with paired emitter detector diode (PEDD) as photometric flow-through detector and bromothymol blue as a model analyte. The best module was implemented into more advanced flow-injection system dedicated for optical detection of alkaline phosphatase activity using UV-PEDD-based flow-through detector for the enzyme reaction product.  相似文献   

16.
The reaction rate for the photochemical rearrangement of 1,6-N-(substituted-phenyl)aza-[60]fulleroid 1 to 1,2-N-(substituted-phenyl)aziridino-[60]fullerene 2 differed ca. 3000-fold depending on the position and number of methyl substituents on the N-phenyl group. The required time for the completion of the reaction decreased in the order 2,6-dimethylphenyl (1d) < 2-methylphenyl (1b) < phenyl (1a) < 4-methylphenyl (1c). The difference was mainly due to switching of the excited states between normal (fast reactions) and charge-separated (slow reactions) triplet states, which was induced by steric interactions between the N-phenyl group and the C60 moiety.  相似文献   

17.
Trace element speciation in biomedical and environmental science has gained increasing attention over the past decade as researchers have begun to realize its importance in toxicological studies. Several nanomaterials, including titanium dioxide nanoparticles (nano-TiO2), carbon nanotubes (CNTs), and magnetic nanoparticles (MNPs), have been used as sorbents to separate and preconcentrate trace element species prior to detection through mass spectrometry or optical spectroscopy. Recently, these nanomaterial-based speciation techniques have been integrated with microfluidics to minimize sample and reagent consumption and simplify analyses. This review provides a critical look into the present state and recent applications of nanomaterial-based microanalytical systems in the speciation of trace elements. The adsorption and preconcentration efficiencies, sample volume requirements, and detection limits of these nanomaterial-based speciation techniques are detailed, and their applications in environmental and biological analyses are discussed. Current perspectives and future trends into the increasing use of nanomaterial-based microfluidic techniques for trace element speciation are highlighted.  相似文献   

18.
This review presents the evolution of recent flow-based analytical systems, characterized by the use of arrays of sensors as a detection scheme. For the proper processing of the complex responses generated, the systems require the use of advanced chemometric treatment, in which received the term “electronic tongue”. Applications employing the flow injection analysis (FIA) and sequential injection analysis (SIA) are described. Chronologically, the progresses made by different research groups are shown, emphasizing their final applications in real problem solving.  相似文献   

19.
The concept of multi-commutation in flow analysis is revisited, and emphasis is given to recent methodological and applicative achievements. Multi-commutation is compatible with different flow patterns (unsegmented, segmented, pulsed, tandem) and amenable to concentration-oriented feedback mechanisms. Its exploitation has led to significant attainments mainly in relation to versatility of the flow system. Characteristics and potentialities of the multi-commuted flow systems are discussed, and guidelines for assisting methodological implementation are given.The number of applications has experienced remarkable increase during last years; therefore, the applicative part of this review is focused on the recent noteworthy applications, mainly in relation to environmental, agronomical, pharmaceutical, biological, food and industrial samples.  相似文献   

20.
Various flow sample handling approaches coupled to capillary electrophoresis (CE) are reviewed, covering the research in this field in the 12 years since the milestone year of 1997, when practical interfaces to on-line couple flow injection (FI) and capillary electrophoresis were first developed independently by two research groups. Some previous attempts are also presented. Since 1997 a plethora of ingenious coupled systems have been developed. Although several reviews are available on various aspects of the topic, we have opted for a comprehensive overview of all FI-CE systems, as well as related and similar systems. This coupling has thus also led to the development of systems based on hybrids between the classical and microchip approaches. Truly microchip FI-CE systems are also included in this review.The developed systems have been used for various sample treatments, including on-line membrane-assisted sample treatment, column-based preconcentration, on-line derivatization and monitoring, to name just a few. The utility of coupling flow sampling to CE has been demonstrated in various practical applications that are discussed in detail. The current state-of-the-art and foreseeable future developments are also discussed.  相似文献   