首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new cloud vapor zone (CVZ)-based headspace solid-phase microextraction (HS-SPME) technique has been demonstrated with the capability of heating the sample matrix and simultaneously cooling the sampling zone. A bi-temperature-controlled (BTC) system, allowing 10 mL of test sample heating and headspace external-cooling, was employed for the CVZ formation around the SPME-fiber sampling area. In the CVZ procedure, the heated headspace vapor undergoes a sudden cooling near the SPME to form a dense cloud of analyte–water vapor, which is helpful for adsorption or absorption of the analyte. The device was evaluated for the quantitative analysis of aqueous chlorothalonil. Parameters influencing sampling efficiency, e.g., SPME fiber coating, SPME sampling temperature and time, solution modifier, addition of salt, sample pH, and temperature, were investigated and optimized thoroughly. The proposed BTC-HS-SPME method afforded a best extraction efficiency of above 94% accuracy (less than 4.1% RSD, n = 7) by using the PDMS fiber to collect chlorothalonil in the headspace at 5 °C under the optimized condition, i.e., heating sample solution (added as 10% ethylene glycol and 30% NaCl, at pH 7.0) at 130 °C for 15 min. The detection was linear from 0.01 to 80 μg L−1 with a regression coefficient of 0.9998 and had a detection limit of 3.0 ng L−1 based on S/N = 3. Practical application was demonstrated by analyzing chlorothalonil in farm water samples with promising results and recoveries. The approach provided a very simple, fast, sensitive, and solvent-free procedure to collect analytes from aqueous solution. The approach can provide a new platform for other sensitive HS-SPME assays.  相似文献   

2.
Ming-Chi Wei 《Talanta》2007,72(4):1269-1274
The novel pretreatment technique, microwave-assisted heating coupled to headspace solid-phase microextraction (MA-HS-SPME) has been studied for one-step in situ sample preparation for polycyclic aromatic hydrocarbons (PAHs) in aqueous samples before gas chromatography/flame ionization detection (GC/FID). The PAHs evaporated into headspace with the water by microwave irradiation, and absorbed directly on a SPME fiber in the headspace. After being desorbed from the SPME fiber in the GC injection port, PAHs were analyzed by GC/FID. Parameters affecting extraction efficiency, such as SPME fiber coating, adsorption temperature, microwave power and irradiation time, and desorption conditions were investigated.Experimental results indicated that extraction of 20 mL aqueous sample containing PAHs at optional pH, by microwave irradiation with effective power 145 W for 30 min (the same as the extraction time), and collection with a 65 μm PDMS/DVB fiber at 20 °C circular cooling water to control sampling temperature, resulted in the best extraction efficiency. Optimum desorption of PAHs from the SPME fiber in the GC hot injection port was achieved at 290 °C for 5 min. The method was developed using spiked water sample such as field water with a range of 0.1-200 μg/L PAHs. Detection limits varied from 0.03 to 1.0 μg/L for different PAHs based on S/N = 3 and the relative standard deviations for repeatability were <13%. A real sample was collected from the scrubber water of an incineration system. PAHs of two to three rings were measured with concentrations varied from 0.35 to 7.53 μg/L. Recovery was more than 88% and R.S.D. was less than 17%. The proposed method is a simple, rapid, and organic solvent-free procedure for determination of PAHs in wastewater.  相似文献   

3.
This work is a first study on extraction efficiency and thermal stability of nano-structured self-doped polyaniline (SPAN) as a coating of solid-phase microextraction (SPME) fibers. SPAN-based fibers were prepared using electrochemical deposition on platinum wires. The particle sizes of prepared nano-structure were in the range of 50–100 nm. Extraction properties of the fiber to 1,4-dioxane were examined using headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-flame ionization detection (GC-FID). The results have proved higher thermal stability of the proposed fiber compared to common PANI fiber. The SPAN coating was proved to be very stable at relatively high temperatures (up to 350 °C) with high extraction capacity and long lifespan (more than 50 times). Therefore, it can be a good substitute of polyaniline (PANI) as a SPME coating. The extraction procedure was optimized by selecting the appropriate extraction parameters including extraction time, extraction temperature, salt concentration, stirring rate and headspace volume. Calibration graph was linear in the concentration range of 1–100 ng mL−1 (R2 > 0.993) with detection limit of 0.1 ng mL−1. Single fiber and fiber-to-fiber repeatability were lower than 6.0% and 10.4%, respectively. Different water samples were analyzed as real samples and good recoveries (98–120%) were obtained.  相似文献   

4.
A method was developed for the analysis of volatile polar compounds in a water matrix using open cap vials Solid Phase Micro-Extraction (SPME) and Capillary Gas Chromatography (CGC). Both SPME techniques – direct sampling and headspace – were tested. Optimization of experimental conditions – exposure time, desorption time, with headspace SPME in addition the influence of the temperature and ionic strength of the sample solution on compound sorption, and finally GC response – were investigated. The analytes were extracted by directly immersing the 85 μm polyacrylate fiber in the aqueous sample or in the headspace. The linear range of the preconcentration process and the precision were examined. The amount of polar analytes sorbed on the fiber was determined and was found to be concentration dependent; it amounted to 0.014–0.64% in the concentration range of 0.00425–425 ppm studied in aqueous solution for direct sampling SPME and to 0.011–2.76% for solutions of concentration 0.0425–255 ppm for headspace SPME. The limits of determination were ascertained. Headspace SPME was applied to the analysis of real-life samples.  相似文献   

5.
The complex aroma of wine is derived from many sources, with grape-derived components being responsible for the varietal character. The ability to monitor grape aroma compounds would allow for better understanding of how vineyard practices and winemaking processes influence the final volatile composition of the wine. Here, we describe a procedure using GC–MS combined with headspace solid-phase microextraction (HS-SPME) for profiling the free volatile compounds in Cabernet Sauvignon grapes. Different sample preparation (SPME fiber type, extraction time, extraction temperature and dilution solvent) and GC–MS conditions were evaluated to optimize the method. For the final method, grape skins were homogenized with water and 8 ml of sample were placed in a 20 ml headspace vial with addition of NaCl; a polydimethylsiloxane SPME fiber was used for extraction at 40 °C for 30 min with continuous stirring. Using this method, 27 flavor compounds were monitored and used to profile the free volatile components in Cabernet Sauvignon grapes at different maturity levels. Ten compounds from the grapes, including 2-phenylethanol and β-damascenone, were also identified in the corresponding wines. Using this procedure it is possible to follow selected volatiles through the winemaking process.  相似文献   

6.
J.J. Rios  A. Morales 《Talanta》2010,80(5):2076-180
A solvent-free analytical approach based on headspace solid-phase microextraction (SPME) of oil matrices heated at high temperatures coupled to gas chromatography with mass spectrometry detector (GC-ion trap) has been developed for the determination of phthalic acid esters (PAEs) in oil matrices without sample manipulation. For this study, three fibers, i.e., 85 μm-polyacrylate (PA), 50/30 μm-divinylbenzene-carboxen-polydimethylsiloxane (DVB/CAR/PDMS) and 100 μm-polydimethylsiloxane (PDMS) were tested. Variables affecting the SPME headspace composition such as incubation sample temperature, sample incubation time and fiber exposition time were optimized. The optimal values found were 250 °C for sample incubation temperature and 30 min for incubation and extraction time. PA fiber was not suitable for the lightest polar phthalates which showed poor extraction and repeatability values. PDMS fiber had very poor response for some of the heavier and non-polar phthalates, whereas DVB/CAR/PDMS fiber showed the best response and repeatability values for the majority of the phthalates studied. The main benefit of the analytical method proposed is the absence of sample manipulation and hence avoidance of possible contamination coming from glassware, environment, solvents and samples.  相似文献   

7.
A new generation of solid-phase microextraction (SPME) fiber, an internally cooled fiber (cold fiber with polydimethylsiloxane loading) that allows heating the sample matrix and simultaneously cooling the fiber coating, was used to determine 2,4-dichloroanisole, 2,6-dichloroanisole, 2,4,6-trichloroanisole and pentachloroanisole in cork. A comparison between the cold fiber and regular SPME fiber was performed. An automated headspace solid-phase microextraction (HS-SPME) using commercial fibers and an internally cooled SPME fiber (CF-HS-SPME) coupled to gas chromatography-time-of-flight mass spectrometry (GC-TOF-MS) was used. The extraction conditions for both CF-HS-SPME and HS-SPME were optimized using full factorial design and Doehlert matrix. The best extraction conditions for CF-HS-SPME were obtained using 10 min of incubation time, 10 min of extraction time, and sample and fiber temperature of 130 and 10 degrees C, respectively. For HS-SPME, polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used with 10 min of incubation time, 75 min of extraction time, 85 degrees C of sample temperature, 8 ml of water was added and agitated at 500 rpm. The quantification limits for the target compounds using CF-HS-SPME procedure were between 0.8 and 1.6 ng g(-1) of cork, while for HS-SPME were between 4 and 6 ng g(-1) of cork. Furthermore, the CF-HS-SPME procedure could be used as a non-destructive method after minor modification of the agitator for the autosampler.  相似文献   

8.
Yan CT  Shih TS  Jen JF 《Talanta》2004,64(3):650-654
Microwave-assisted desorption (MAD) coupled to in situ headspace solid-phase microextraction (HS-SPME) was first proposed as a possible alternative pretreatment of samples in absorbent collected from workplace monitoring. Aniline collected on silica gel was investigated. Under microwave irradiation, the aniline was desorbed from silica gel and directly absorbed onto the SPME fiber in the headspace. Having been sampled on the SPME fiber, and desorbed in the GC injection port, aniline was analyzed using a GC-FID system. Parameters that affect the proposed extraction efficiency, including the extraction media and its pH, the microwave irradiation power and the irradiation time as well as desorption parameters of the GC injector, were investigated. Experimental results revealed that the extraction of a 150-mg silica gel sample using a 0.8-ml aqueous solution (pH 12) and a PDMS/DVB fiber under medium-high-powered irradiation (345 W) for 3 min maximized the efficiency of extraction. Desorption of aniline from the SPME fiber was optimal at 230 °C held for 3 min. The detection limit was 0.09 ng. The proposed method provided a simple, fast, and organic solvent-free procedure to analyze aniline from a silica gel matrix.  相似文献   

9.
Two different strategies for the quantitative determination of 3-alkyl-2-methoxypyrazines in wine and must have been developed and validated. Comparison between both the techniques has been presented and the most adequate has been applied to the determination of these compounds in different samples of wine, made from several varieties of grapes, and also in different samples of must made from Cabernet Sauvignon grapes. Both the methods consisted of a dynamic headspace coupled with a solid-phase extraction (HS–SPE) and solid-phase extraction (SPE) directly from the sample, coupled with multidimensional gas chromatography–mass spectrometry system (MDGC–MS). Both of them require resins LiChrolut EN, and analyte elution has been carried out with dichloromethane. The repeatability of both methodologies was evaluated at two concentration levels. The relative standard deviations (RSD%) were acceptable in every case, but smaller when working with HS–SPE. The recoveries obtained for the three analytes with the two methodologies were almost 100%, with the exception of IBMP, which had a recovery of only 70% with HS–SPE. The linearity was satisfactory with both methods for the range of occurrence of methoxypyrazines in wine and must. The limits of detection of the direct SPE technique were much lower than those of HS–SPE in every case. Direct SPE method detection limits ranged from 0.09 to 0.15 ng L−1. The method based on direct SPE was chosen finally because it had better detection limits and was easier and quicker than the HS–SPE-based method. It has been applied to the determination of these components in 36 wine and 17 musts samples. The quantitative results suggest that the Spanish wines show meaningless amounts of these compounds. IBMP has been found just in between 1.9 and 15 ng L−1.  相似文献   

10.
A new solid-phase microextraction (SPME) procedure using an ionic liquid (IL) has been developed. Reusable IL-based SPME fiber was prepared for the first time by fixing IL through cross-linkage of IL impregnated silicone elastomer on the surface of a fused silica fiber. 1-Ethoxyethyl-3-methylimidazloium bis(trifluoromethane) sulfonylimide ([EeMim][NTf2]) ionic liquid was employed as a demonstration and the prepared fiber was applied to the forensic headspace determination of methamphetamine (MAP) and amphetamine (AP) in human urine samples. Important extraction parameters including the concentration of salt and base in sample matrix, extraction temperature and extraction time were investigated and optimized. Combined with gas chromatography/mass spectrometry (GC/MS) working in selected ion monitoring (SIM) mode, the new method showed good linearity in the range of 20–1500 μg L−1, good repeatability (RSD < 7.5% for MAP, and <11.5% for AP, n = 6), and low detection limits (0.1 μg L−1 for MAP and 0.5 μg L−1 for AP). Feasibility of the method was evaluated by analyzing human urine samples. Although IL-based SPME is still at the beginning of its development stage, the results obtained by this work showed that it is a promising simple, fast and sensitive sample preparation method.  相似文献   

11.
A new solvent-free analytical procedure based on headspace solid-phase microextraction (SPME) coupled to gas chromatography employing an electron capture detector (GC/ECD) or alternatively a mass spectrometric detector (GC/MSD) has been developed for the determination of phthalic acid esters (dimethyl-[DMP], diethyl-[DEP], di-n-butyl-[DnBP], butylbenzyl-[BBP], di-2-ethylhexyl-[DEHP] and di-n-octyl [DnOP] phthalate) in vegetable oils. Four different fiber coatings were evaluated, among them polydimethylsiloxane with a thickness of 100 μm appeared to be the best choice for allowing extraction of the whole group of analytes. Various solvents were tested as sample matrix modification agents with the aim to facilitate the transfer of esters with low vapour pressure (DEHP and DnOP) from oil matrix into the headspace. The addition of methanol resulted in optimal set-up applicable for all phthalate esters. Temperature control and the way of sample stirring were recognized as critical points of the whole procedure. Primarily, because shaking rather than stirring of the sample is carried out using a CombiPal multipurpose sampler, the automation of the SPME method employing this instrument was found to be not fully suitable for efficient stripping of phthalates from the oil matrix into the sample headspace. Nevertheless, the optimized manual SPME method, encompassing GC/ECD or GC/MSD for the separation and detection of target analytes, offers a unique solution and showed acceptable performance characteristics: linear response in the range of 0.5-2 mg kg−1 and repeatability expressed as R.S.D. between 14 and 23% at the spiking level of 2 mg kg−1.  相似文献   

12.
A current review of the application of solid-phase microextraction (SPME) to the analysis of ignitable liquids and explosive residues is presented along with experimental results demonstrating the relative effects of controllable variables. Variables discussed include fiber chemistry, adsorption and desorption temperatures, extraction and desorption times, fiber sampling placement (direct, headspace, and partial headspace) and matrix effects, including water content. SPME is shown to be an inexpensive, rapid and sensitive method for the analysis of ignitable liquids and high explosives residues from solid debris samples and from aqueous samples. Explosives are readily detected at parts per trillion concentrations and ignitable liquids are reproducibly detected at levels below those using conventional methods.  相似文献   

13.
A solid-phase microextraction method (SPME) for determining trace levels of synthetic musk fragrances in residual waters has been developed. Six polycyclic musks (cashmeran, phantolide, celestolide, traseolide, galaxolide and tonalide), and a macrocyclic musk (ambrettolide) have been analysed. A detailed study of the different parameters affecting the extraction process is presented. The main important factors affecting the microextraction process have been studied and optimised by means of a categorical factorial design. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using four different fiber coatings [polydimethylsiloxane (PDMS), Carboxen (CAR)-PDMS, PDMS-divinylbenzene (DVB) and Carbowax (CW)-DVB]. An extraction temperature of 100 degrees C sampling the headspace over the sample using CAR-PDMS or PDMS-DVB as fiber coatings were found to be the experimental conditions that lead to a more effective extraction. The method proposed is very simple and yields high sensitivity, with detection limits in the low pg/ml, good linearity and repeatability for all the target compounds. The total analysis time, including extraction and GC analysis, was only 45 min. The optimised method performed well when it was applied to waste water from an urban treatment plant.  相似文献   

14.
A solid-phase microextraction (SPME) fiber coated with single walled carbon nanotubes (SWCNTs) was prepared by electrophoretic deposition and treated at 500 °C in H2 stream. In order to evaluate the characteristics of the obtained fiber, it was applied in the headspace solid-phase microextraction (HS-SPME) of benzene, toluene, ethylbenzene and xylenes (BTEX) from water sample and quantification by gas chromatography with flame ionization detection (GC-FID). The results indicated that the thermal treatment with H2 enhanced the extraction of the SWCNTs fiber for BTEX significantly. Thermal stability and durability of the fiber were also investigated, showing excellent stability up to 350 °C and life time over 120 times. In the comparison with the commercial CAR–PDMS fiber, the SWCNTs fiber showed similar and higher extraction efficiencies for BTEX. Under the optimized conditions, the linearity, LODs (S/N = 3) and LOQs (S/N = 10) of the method based on the SWCNTs fiber were 0.5–50.0, 0.005–0.026 and 0.017–0.088 μg/L, respectively. Repeatability for one fiber (n = 3) was in the range of 1.5–5.6% and fiber-to-fiber reproducibility (n = 3) was in the range of 4.2–8.3%. The proposed method was successfully applied in the analysis of BTEX compounds in seawater, tap water and wastewater from a paint plant.  相似文献   

15.
Natalia Campillo 《Talanta》2010,80(5):1856-1861
A method based on solid-phase microextraction (SPME) followed by gas chromatography with microwave-induced plasma atomic emission detection for determining dimethylselenide (DMSe) and dimethyldiselenide (DMDSe) in milk and milk by-products is proposed. Parameters affecting the SPME, such as sample volume or mass, ionic strength, adsorption and desorption times and temperatures were optimized in the headspace mode. The matrix effect was evaluated for the different samples studied, concluding that standard additions calibration was required for quantification purposes. The detection limits ranged from 70 to 110 pg mL−1 for DMSe and from 80 to 400 pg mL−1 for DMDSe, depending on the sample under analysis. None of the twenty-three samples analyzed contained the studied compounds at concentrations above the corresponding detection limits.  相似文献   

16.
A novel multiwalled carbon nanotubes–polyaniline composite (MWCNTs–PANI) film coated platinum wire was fabricated through electrochemical deposition. The coating was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectrophotometry and thermogravimetry. It was found that the coating was porous and had large specific area and adsorption capacity; in the composite MWCNTs and polyaniline interacted with each other and the film kept stable up to 320 °C. The as-made fiber was used for the headspace solid-phase microextraction (HS-SPME) of some phenolic compounds (i.e. 2-chlorophenol, 2,4-dichlorophenol, 2-methylphenol, 3-methylphenol, 2,6-dimethylphenol, 2-nitrophenol), followed by gas chromatographic analysis. The MWCNTs–PANI coating showed better analytical performance than PANI. Under the optimized conditions, the detection limits were 1.89–65.9 ng L−1, the relative standard deviations (RSDs) were 2.7–6.5% for six successive measurements with single fiber, the RSDs for fiber-to-fiber were 5.2–12.4%, the linear ranges exceeded two magnitudes with correlation coefficient above 0.992. The fiber could be used for more than 250 times without decrease of efficiency. The proposed method was successfully applied to the extraction and determination of phenolic compounds in water sample, and the recoveries were 87.7–111.5% for different analytes. In addition, the fiber also presented advantages of easy preparation and low cost. Therefore, it is a promising SPME fiber.  相似文献   

17.
Determination of aniline in wastewater was investigated by microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for one-step in-situ sample preparation, and gas chromatography. Aniline in the water was evaporated into the headspace under the action of microwave irradiation and adsorbed directly by the SPME fiber. After desorption in the GC injection port and gas chromatography aniline was detected by FID. Conditions affecting the extraction efficiency, for example the pH of the water, addition of salt, microwave power and irradiation time, and desorption conditions were investigated. Experimental results indicated that adjustment of the pH of the water sample to 12 and headspace SPME sampling with a PDMS-DVB fiber under medium–high power irradiation (345 W) for 3 min resulted in the best extraction efficiency. Desorption of aniline was optimum when the SPME fiber was heated at 230 °C for 3 min. The detection limit was approximately 0.01 g mL–1. The proposed method is a simple, fast, and organic-solvent-free procedure for analysis of aniline in water. Application was illustrated by analysis of aniline in wastewater from a polymer factory.  相似文献   

18.
Fang H  Liu M  Zeng Z 《Talanta》2006,68(3):979-986
A sensitive method for determination of ephedrine derivatives using headspace solid-phase microextraction (SPME) with a novel fiber followed by capillary electrophoresis has been developed. The co-poly(butyl methacrylate/hydroxy-terminated silicone oil) (BMA/OH-TSO) was used as stationary phases with the aid of γ-methacryloxypropyltrimethoxysilane (KH-570) as bridge in SPME using sol-gel-coating method and cross-linking technology. It has high extraction efficiency for ephedrine derivatives in comparison with commercial poly(dimethylsiloxane) and poly(acrylate)-coated fiber. The coating exhibits good thermal and solvent stability as well as long lifetime. A simple and flexible device for desorption of analytes after headspace SPME was constructed. The effect of various experimental parameters for SPME (temperature, time, pH, ionic strength, desorption solvent, etc.) were discussed. Field amplified sample injection (FASI) was applied for on-line sample concentration and a sensitivity enhancement of two orders of magnitude was achieved. Linear ranges were found to be 20-5000 ng/ml. The detection limits for (1R,2S)-ephedrine, (1R,2R)-pseudoephedrine and (1S,2S)-pseudoephedrine were 3, 5 and 5 ng/ml, respectively. Relative standard deviation (n = 6) was found to be 4.96-7.57%. The method was successfully applied to the analysis of ephedrine derivatives in human urine.  相似文献   

19.
Solid-phase microextraction (SPME) is a fast, solvent-free alternative to conventional sample preparation techniques. This technique involves exposing a fused silica fiber that has been coated with a stationary phase to an aqueous solution or its headspace to selectively extract compounds from their matrix. The fiber is then removed, and the analytes are thermally desorbed in the injector of a gas chromatograph. By sampling from the headspace above sample matrices, SPME can be used to extract target analytes from very complex matrices. In this study, SPME in the headspace is used in developing a method for the dye 1-methylaminoanthraquinone (MAAQ) and two lachrymators: orthochlorobenzalmalononitrile (CS) (tear gas) and 2-chloroacetophenone (CN) (tear gas). The focus is to develop a robust method to minimize sample preparation and to reduce matrix interferences encountered by other extraction techniques. In developing the method, several fibers are studied for their affinity for the compounds of interest. Although this method is developed for qualitative analysis, the extraction time and temperature profile are thoroughly investigated to provide the optimal conditions. The use of a salt solution is evaluated to increase the partitioning of MAAQ into the headspace. Using this method, qualitative extraction is achieved for the analysis of CN, CS, and MAAQ from its matrices. CN and CS are extracted in less than 5 min, though MAAQ needed more than 15 min to achieve a reasonable response. If more sensitivity is required, the use of a salt solution increases the response of MAAQ by 90-fold.  相似文献   

20.
A modified Rheodyne 7520 microsample injector was used as a new solid phase microextraction (SPME)–liquid chromatography (LC) interface. The modification was focused on the construction of a new sample rotor, which was built by gluing two sample rotors together. The new sample rotor was further reinforced with 3 pieces of stainless steel tubing. The enlarged central flow passage in the new sample rotor was used as a desorption chamber. SPME fiber desorption occurred in static mode. But all desorption solvent in the desorption chamber was injected into LC system with the interface. The analytical performance of the interface was evaluated by SPME–LC analysis of PAHs in water. At least 90% polycyclic aromatic hydrocarbons (PAHs) were desorbed from a polyacrylonitrile (PAN)/C18 bonded fuse silica fiber in 30 s. And injection was completed in 20 s. About 10–20% total carryovers were found on the fiber and in the interface. The carryover in the interface was eliminated by flushing the desorption chamber with acetonitrile at 1 mL min−1 for 2 min. The repeatability of the method was from 2% to 8%. The limit of detection (LOD) was in the mid pg mL−1 range. The linear ranges were from 0.1 to 100 ng mL−1. The new SPME–LC interface was reliable for coupling SPME with LC for both qualitative and quantitative analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号