首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new binding agent, consisting of the yeast Saccharomyces cerevisiae immobilized in agarose, is proposed for use in diffusive gradients in thin films (DGT). Different gel compositions, containing from 4.5% to 20% (m/v) of S. cerevisiae and 1.5-5.0% (m/v) of agarose, were prepared and tested for uptake of Cd(II). For gels containing 20% (m/v) of S. cerevisiae, a mass of 14,900 ng has been attributed as the uptake limit of Cd for each disk. Determination of the Cd retained in the binding agent was readily carried out using a slurry of the agarose-yeast disk introduced directly into the inductively coupled plasma optical emission spectrometer. The performance characteristics of the DGT samplers, which were assembled with the proposed binding agent (25 mm disk containing 20% of S. cerevisiae and 1.5% of agarose) and a diffusive layer of cellulose (chromatographic paper 3MM Chr of 25 mm diameter), were evaluated by measuring the Cd(II) uptake at various pH values and ionic strengths. Very consistent results were found within the pH range 4.5-7.5 and at ionic strengths ≥0.005 mol L−1. The precision of DGT measurements was characterized by relative standard deviations of <8%. No changes in the uptake of Cd(II) were observed in the samplers that were assembled with recently prepared disks or 35-day-old stored disks. The proposed material has been applied to the analyses of river and sea water samples. For determination of Cd(II), excellent agreement between the results obtained from devices assembled with the proposed material and those assembled with conventional material (Chelex-100 resin) were obtained, strongly validating the use of the agarose-yeast gel disk as a new binding agent for DGT.  相似文献   

2.
A series of experiments were undertaken to investigate the effect of ionic strength and the concentration of free sodium ions in the resin gel on the performance of the diffusive gradients in thin films (DGT) technique. When the free sodium ion concentration in the resin gel was estimated by the time-dependent release into solution, it agreed with a previous estimate. However, equilibration with different volumes of water gave a higher value, suggesting that inherent averaging in the time-dependent release method underestimates the free concentration. DGT measurements of Cu and Cd were made over a wide range of ionic strengths (from 3 μmol l−1 to 0.8 mol l−1). For all the ionic strengths above 100 μmol l−1 there was no significant difference between measurements made by DGT and measurements made directly on the solution using atomic absorption spectroscopy. Below 100 μmol l−1 results were erratic. They did not comply with a theory that predicts high results for DGT based on enhancement of the diffusion coefficient of trace metal cations by counter diffusion of sodium ions. When Cd in solutions with a range of ionic strengths was measured by DGT there was no difference whether the resin gels were in Na or Ca form. Rather than counter diffusion of Na ions, it is suggested that the spurious behaviour at low ionic strength is due to interactions of the trace metals with the diffusion gel when there are insufficient excess cations present.  相似文献   

3.
Saccharomyces cerevisiae immobilized in agarose gel as binding phase and polyacrylamide as diffusive layer in the diffusive gradient in thin films technique (DGT) was used for selective determination of methylmercury (MeHg). Deployment tests showed good linearity in mass uptake up to 48 h (3276 ng). When coupling the DGT technique with Cold Vapor Atomic Fluorescence Spectrometry, the method has a limit of detection of 0.44 ng L−1 (pre concentration factor of 11 for 48 h deployment). Diffusion coefficient of 7.03 ± 0.77 × 10−6 cm2 s−1 at 23 °C in polyacrylamide gel (pH = 5.5 and ionic strength = 0.05 mol L−1 NaCl) was obtained. Influence of ionic strength (from 0.0005 mol L−1 to 0.1 mol L−1 NaCl) and pH (from 3.5 to 8.5) on MeHg uptake were evaluated. For these range, recoveries of 84–105% and 84–98% were obtained for ionic strength and pH respectively. Potential interference due to presence of Cu, Fe, Mn, Zn was also assessed showing good recoveries (70–87%). The selectivity of the proposed approach was tested by deployments in solutions containing MeHg and Hg(II). Results obtained showed recoveries of 102–115 % for MeHg, while the uptake of Hg(II) was insignificant. The proposed approach was successfully employed for in situ measurements in the Negro River (Manaus-AM, Brazil).  相似文献   

4.
Three adsorbents (Chelex-100, manganese dioxide [MnO2] and Metsorb), used as binding layers with the diffusive gradient in thin film (DGT) technique, were evaluated for the measurement of inorganic uranium species in synthetic and natural waters. Uranium (U) was found to be quantitatively accumulated in solution (10–100 μg L−1) by all three adsorbents (uptake efficiencies of 80–99%) with elution efficiencies of 80% (Chelex-100), 84% (MnO2) and 83% (Metsorb). Consistent uptake occurred over pH (5–9), with only MnO2 affected by pH < 5, and ionic strength (0.001–1 mol L−1 NaNO3) ranges typical of natural waters, including seawater. DGT validation experiments (5 days) gave linear mass uptake over time (R2 ≥ 0.97) for all three adsorbents in low ionic strength solution (0.01 M NaNO3). Validation experiments in artificial sea water gave linear mass uptake for Metsorb (R2 ≥ 0.9954) up to 12 h and MnO2 (R2 ≥ 0.9259) up to 24 h. Chelex-100 demonstrated no linear mass uptake in artificial sea water after 8 h. Possible interferences were investigated with SO42− (0.02–200 mg L−1) having little affect on any of the three DGT binding layers. PO43− additions (5 μg L−1–5 mg L−1) interfered by forming anionic uranyl phosphate complexes that Chelex-100 was unable to accumulate, or by directly competing with the uranyl species for binding sites, as with MnO2 and the Metsorb. HCO3 (0.1–500 mg L−1) additions formed anionic species which interfered with the performance of the Chelex-100 and the MnO2, and the Ca2+ (0.1–500 mg L−1) had the affect of forming labile calcium uranyl species which aided uptake of U by all three resins. DGT field deployments in sea water (Southampton Water, UK) gave a linear mass uptake of U over time with Metsorb and MnO2 (4 days). Field deployments in fresh water (River Lambourn, UK) gave linear uptake for up to 7 and 4 days for Metsorb and MnO2 respectively. Field deployment of the Metsorb-DGT samplers with various diffusive layer thicknesses (0.015–0.175 cm) allowed accurate measurements of the diffusive boundary layer (DBL) and allowed DBL corrected concentrations to be determined. This DBL-corrected U concentration was half that determined when the effect of the DBL was not considered. The ability of the DGT devices to measure U isotopic ratios with no isotopic fractionation was shown by all three resins, thereby proving the usefulness of the technique for environmental monitoring purposes.  相似文献   

5.
A simple, low cost, and highly sensitive electrochemical sensor, based on a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode (N/IL/G/SPCE) was developed to determine zinc (Zn(II)), cadmium (Cd(II)), and lead (Pb(II)) simultaneously. This disposable electrode shows excellent conductivity and fast electron transfer kinetics. By in situ plating with a bismuth film (BiF), the developed electrode exhibited well-defined and separate peaks for Zn(II), Cd(II), and Pb(II) by square wave anodic stripping voltammetry (SWASV). Analytical characteristics of the BiF/N/IL/G/SPCE were explored with calibration curves which were found to be linear for Zn(II), Cd(II), and Pb(II) concentrations over the range from 0.1 to 100.0 ng L−1. With an accumulation period of 120 s detection limits of 0.09 ng mL−1, 0.06 ng L−1 and 0.08 ng L−1 were obtained for Zn(II), Cd(II) and Pb(II), respectively using the BiF/N/IL/G/SPCE sensor, calculated as 3σ value of the blank. In addition, the developed electrode displayed a good repeatability and reproducibility. The interference from other common ions associated with Zn(II), Cd(II) and Pb(II) detection could be effectively avoided. Finally, the proposed analytical procedure was applied to detect the trace metal ions in drinking water samples with satisfactory results which demonstrates the suitability of the BiF/N/IL/G/SPCE to detect heavy metals in water samples and the results agreed well with those obtained by inductively coupled plasma mass spectrometry.  相似文献   

6.
The diffusive gradients in thin films technique (DGT) was used for uranium measurements in water. DGT devices with Dowex resin binding phase (Dow DGT) were tested in synthetic river water, which gave 84% response to total uranium concentration. The devices were also deployed in natural river water and compared to devices with other types of binding phases, Chelex 100 resin beads imbedded in polyacrylamide hydrogel (Chelex DGT) and DE 81 anion exchange membrane (DE DGT), deployed in the same location at the same time. The measurement by Dow DGT was the lowest among the different types of the DGT devices, 45% of total uranium, while measurement by DE DGT was the highest, 98% of total uranium. The results achieved by the three types of DGT devices were explained by three DGT working mechanisms, equilibrium between complexes of resin/uranyl carbonates and complexes of resin/competitive ligands in water, effective reduction of uranyl carbonate concentration by the binding phase and dissociation of UO2(CO3)22− and UO2(CO3)34− within the diffusive layer in a DGT device. It is hoped that by deploying the DGT devices with different binding phases in natural waters, additional information on uranium speciation could be obtained.  相似文献   

7.
A new diffusive gradients in a thin film (DGT) technique, using Microlite PrCH cation exchange resin, was developed and evaluated for measuring NH4–N in freshwaters. Microlite PrCH had high uptake (>92.5%) and elution efficiencies (87.2% using 2 mol L−1 NaCl). Mass vs. time validation experiments over 24 h demonstrated excellent linearity (R2 ≥ 0.996). PrCH-DGT binding layers had an extremely high intrinsic binding capacity for NH4–N (∼3000 μg). NH4–N uptake was quantitative over pH ranges 3.5–8.5 and ionic strength (up to 0.012 mol L−1 as NaCl) typical of freshwater systems. Several cations (Na+, K+, Ca2+ and Mg2+) were found to compete with NH4–N for uptake by PrCH-DGT, but NH4–N uptake was quantitative over concentration ranges typical of freshwater (up to 0.012 mol L−1 Na+, 0.006 mol L−1 K+, 0.003 mol L−1 Ca2+ and 0.004 mol L−1 Mg2+). Effective diffusion coefficients determined from mass vs. time experiments changed non-linearly with electrical conductivity. Field deployments of DGT samplers with varying diffusive layer thicknesses validated the use of the technique in situ, allowed deployment times to be manipulated with respect to NH4–N concentration, and enable the calculation of the diffusive boundary layer thickness. Daily grab sample NH4–N concentrations were observed to vary considerably independent of major rainfall events, but good agreements were obtained between PrCH-DGT values and mean grab sample measurements of NH4–N (CDGT:CSOLN 0.83–1.3). Reproducibility of DGT measurements in the field was good (relative standard deviation < 11%). Limit of detection was 0.63 μg L−1 (equivalent to 0.045 μmol L−1) based on 24 h deployments.  相似文献   

8.
A novel dual-ligand reagent (2Z)-N,N′-bis(2-aminoethylic)but-2-enediamide, was synthesized and applied to prepare metal ion-imprinted polymers (IIPs) materials by ionic imprinted technique for selective solid-phase extraction (SPE) of trace Cd(II) from aqueous solution. In the first step, Cd(II) formed coordination linkage with the two ethylenediamine groups of the synthetic monomer. Then the complex was copolymerized with pentaerythritol triacrylate (crosslinker) in the presence of 2,2′-azobisisobutyronitrile as initiator. Subsequently, the imprinted Cd(II) was completely removed by leaching the dried and powdered materials particles with 0.5 M HCl. The obtained IIPs particles exhibited excellent selectivity for target ion. The distribution ratio (D) values of Cd(II)-IIPs for Cd(II) were greatly larger than that for Cu(II), Zn(II) and Hg(II). The relative selective factor (αr) values of Cd(II)/Cu(II), Cd(II)/Zn(II) and Cd(II)/Hg(II) were 25.5, 35.3 and 62.1. The maximum static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Cd(II) was 32.56 and 6.30 mg g−1, respectively. Moreover, the times of adsorption equilibration and complete desorption were remarkably short. The prepared Cd(II)-IIPs were shown to be promising for solid-phase extraction coupled with inductively coupled plasma atomic emission spectrometry (ICP-AES) for the determination of trace Cd(II) in real samples. The precision (R.S.D.) and detection limit (3σ) of the method were 2.4% and 0.14 μg L−1, respectively. The column packed with Cd(II)-IIPs was good enough for Cd(II) separation in matrixes containing components with similar chemical behaviour such as Cu(II), Zn(II) and Hg(II).  相似文献   

9.
A novel binding phase was developed for use in diffusive gradients in thin-film (DGT) sampling for Cu(II) by employing methylthymol blue as a chelating and chromogenic agent. Methylthymol blue was adsorbed onto beads of Dowex 1 × 8 resin (200-400 mesh) and the resin beads were then immobilised onto an adhesive disc. Analysis of exposed binding discs by either UV-vis spectrophotometry or computer imaging densitometry provided robust quantification of adsorbed Cu(II) in the 0.2-1 μg cm−2 range, allowing detection at μg L−1 concentrations in the test solution (ca. 17 μg L−1 for a 24 h deployment), and in good agreement with established DGT theory. The method was shown to be a potential replacement for binding phases based on Chelex 100 where a colorimetric response to a specific metal is desired.  相似文献   

10.
A new resin- Diphonix® in Diffusive Gradients in Thin Films (DGT) technique for the determination of uranium was investigated and compared with previously used binding phases for uranium, Chelex®-100 and Metsorb™. The DGT gel preparation and the elution procedure were optimized for the new resin. The U uptake on Diphonix® resin gel was 97.4 ± 1.5% (batch method; [U] = 20 μg L−1; 0.01 M NaNO3; pH = 7.0 ± 0.2). The optimal eluent was found to be 1 M 1-hydroxyethane-1, 1-diphosphonic acid (HEDPA) with an elution efficiency of 80 ± 4.2%. Laboratory DGT study on U accumulation using a DGT samplers with Diphonix® resin showed a very good performance across a wide range of pH (3–9) and ionic strength (0.001–0.7 M NaNO3). Diffusion coefficients of uranium at different pH were determined using both, a diffusion cell and the DGT time-series, demonstrating the necessity of the implementation of the effective diffusion coefficients into U-DGT calculations. Diphonix® resin gel exhibits greater U capacity than Chelex®-100 and Metsorb™ binding phase gels (a Diphonix® gel disc is not saturated, even with loading of 10.5 μmol U). Possible interferences with Ca2+ (up to 1.33 × 10−2 M), PO43−PO43 (up to 1.72 × 10−4 M), SO42−SO42 (up to 4.44 × 10−3 M) and −HCO3HCO3 (up to 8.20 × 10−3 M) on U-DGT uptake ([U] = 20 μg L−1) were investigated. No effect or minor effect of Ca2+, PO43−PO43, SO42−SO42, and −HCO3HCO3 on the quantitative measurement of U by Diphonix®-DGT was observed. The results of this study demonstrated the DGT technique with Diphonix® resin is a reliable and robust method for the measurement of labile uranium species under laboratory conditions.  相似文献   

11.
A method for the simultaneous determination of Pb(II), Cd(II), and Zn(II) at low μg L−1 concentration levels by sequential injection analysis-anodic stripping voltammetry (SIA-ASV) using screen-printed carbon nanotubes electrodes (SPCNTE) was developed. A bismuth film was prepared by in situ plating of bismuth on the screen-printed carbon nanotubes electrode. Operational parameters such as ratio of carbon nanotubes to carbon ink, bismuth concentration, deposition time and flow rate during preconcentration step were optimized. Under the optimal conditions, the linear ranges were found to be 2-100 μg L−1 for Pb(II) and Cd(II), and 12-100 μg L−1 for Zn(II). The limits of detection (Sbl/S = 3) were 0.2 μg L−1 for Pb(II), 0.8 μg L−1 for Cd(II) and 11 μg L−1 for Zn(II). The measurement frequency was found to be 10-15 stripping cycle h−1. The present method offers high sensitivity and high throughput for on-line monitoring of trace heavy metals. The practical utility of our method was also demonstrated with the determination of Pb(II), Cd(II), and Zn(II) by spiking procedure in herb samples. Our methodology produced results that were correlated with ICP-AES data. Therefore, we propose a method that can be used for the automatic and sensitive evaluation of heavy metals contaminated in herb items.  相似文献   

12.
The agarose hydrogel has been increasingly used as a diffusive layer in diffusive gradients in thin films (DGT) measurements. However its diffusive characteristics have not been examined in detail. In this study, the performance of agarose gel was tested in DGT measurements of eight cations (Fe(II), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Pb(II), and Cd(II)) and eight anions (P(V), As(V), Cr(VI), Mo(VI), Sb(V), Se(VI), V(V), and W(VI)). It was found that the thickness of agarose, a key parameter in the calculation of DGT measured concentration, remained unchanged after hydration followed by storage under the following conditions: pH 2–11, ionic strength 0–1.0 M, temperature 4–40 °C, and with the storage time extending to 300 d. Enrichment of cations and repelling of anions were observed in the gel under the ionic strengths of < 2–3 mM and <1 mM (NaNO3), respectively, which was attributed to the electrostatic interactions of these ions with the fixed negatively charged groups (mainly pyruvate) in the gel. The diffusion coefficients of cations and anions through the agarose gel (plus a PVDF filter membrane) were on average 1.10 ± 0.04 times of the reported diffusion coefficients through the agarose cross-linked polyacrylamide (APA) hydrogel, typically used in DGT technique. The working pH ranges for the agarose gel-assembled DGTs were 4–10 and 5–9 for anions and cations, respectively. The use of agarose gel, either individually or along with different filter membranes, affected the overall diffusion rates of cations and anions. The measured DGT concentrations of cations and anions in filtered natural freshwater and seawater were mostly in line with those measured directly. The results showed that the agarose gel can be used as one of the standard diffusive layers in DGT measurements for a wide range of inorganic and organic analytes.  相似文献   

13.
The performance characteristics of an alternative binding agent, suspended particulate reagent-iminodiacetate (SPR-IDA), for use with DGT methodology were investigated. The parameters investigated during this study included gel hydration, blank levels, elution factor (fe), capacity, the effects of pH on the binding of trace metals by DGT. The novel application of this resin for use as a quantitative standard for laser ablation ICP-MS was also evaluated. To further constrain the results for the SPR-IDA binding agent, parallel experiments were performed using resin gel containing Chelex 100, which has been widely reported in the literature. Hydration results showed that the SPR-IDA resin gel reached a stable dimension and weight within ∼30 min and was dimensionally stable for ≤6 months. The measured DGT blanks for the SPR-IDA resin were 0.0023, 0.15, 0.21, 0.0033 and 0.011 ng disc−1 for Co, Ni, Cu, Cd and Pb, respectively. The elution factor differed for the two resin types with the Chelex 100 recoveries slightly lower than previous reports and the SPR-IDA resin showing on average ∼5-9% better recoveries than DGT containing Chelex 100. The measured capacity of DGT discs containing the SPR-IDA binding agent was 0.26 mg Cd, similar to the calculated value of 0.29 mg Cd, indicating the entire resin layer was available for metal uptake.Both resin types performed equally well when deployed in 1 mM NaNO3 solutions with DGT measurements of ∼100% of direct solution measurements for Co, Ni and Cd. However, DGT measurements of Cu and Pb systematically decreased with increasing solution pH down to ∼50% of solution values at pH 8.0, due to artifacts resulting from colloid formation during the addition of the metals. This was remedied by adding the metals as dilute salt standards and addition of Mg(NO3)2 to eliminate adsorption to the container walls. In the latter experiments, DGT measured concentrations of Co, Ni, Cu, Cd and Pb were in agreement with solution concentrations. Deployment of DGT in solutions with increasing concentrations of trace metals yielded linear results, suggesting that quantitative analysis using simplified laser ablation techniques should be possible using this newly characterized SPR-IDA resin gel.  相似文献   

14.
For the first time, a diffusive gradients in thin films (DGT) device using molecularly imprinted polymer (MIP) as the binding agent and nylon membrane (NM) as the diffusive layer (NM-MIP-DGT) has been developed for sampling 4-chlorophenol (4-CP) in water. The MIP was prepared by precipitation polymerization with methacrylic acid as monomer and ethyleneglycoldimethacrylate as cross-linker. The diffusion coefficient of 4-CP through NM was obtained to be 0.788 ± 0.040 μ cm2 s−1 by diffusion cell method. The ratio was 1.01 ± 0.05 (mean ± standard deviation) for the concentration of 4-CP sampled by NM-MIP-DGT and analyzed by HPLC method to the total concentration of 4-CP in the synthetic solution where free 4-CP species dominated. The results showed that NM-MIP-DGT could sample 4-CP in synthetic solution accurately. The performance of NM-MIP-DGT for sampling 4-CP was independent of pH in the range of 3–7 and ionic strength in the range of 0.0001–0.1 mol L−1 NaCl solution. The concentration of free form of 4-CP sampled by NM-MIP-DGT decreased with the increasing concentration of dissolved organic carbon in different water samples due to the electrostatic interaction of natural organic compounds with 4-CP. 1.8 mg L−1 of the free form of 4-CP was determined by HPLC which was sampled by NM-MIP-DGT in an intermediate untreated industrial effluent. The NM-MIP-DGT can be a potential passive tool for sampling the free form of 4-CP in water.  相似文献   

15.
The sorption of radiocadmium on Ca-montmorillonite as a function of contact time, pH, ionic strength, foreign ions, humic acid (HA) and fulvic acid (FA) was studied using batch technique. The results demonstrated that the sorption of Cd(II) was dependent on ionic strength at pH < 9, and was independent of ionic strength at pH > 9. Outer-sphere surface complexation and/or ion exchange were the main mechanism of Cd(II) sorption on Ca-montmorillonite at low pH, whereas the sorption at high pH was mainly dominated via inner-sphere surface complexation. The sorption of Cd(II) on Ca-montmorillonite was dependent on foreign ions at low pH values, but was independent of foreign ions at high pH values. A positive effect of HA/FA on Cd(II) sorption was found at low pH values, whereas a negative effect was observed at high pH values. The thermodynamic parameters (i.e., ??H 0, ??S 0, ??G 0) were calculated from the temperature dependent sorption isotherms, and the results indicated that the sorption process of Cd(II) on Ca-montmorillonite was spontaneous and endothermic.  相似文献   

16.
Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol–gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 μg and 0.8 μg bar−1. The detection limit (3σ) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L−1 and the relative standard deviation (RSD) was 3.38% (c = 1 μg L−1, n = 7). The proposed method was successfully applied for the analysis of trace Cd(II) in rain water, East Lake and Yangtze River water. To validate the proposed method, certified reference material of GSBZ 50009-88 environmental water was analyzed and the determined value is in a good agreement with the certified value. The developed method is rapid, selective, sensitive and applicable for the analysis of trace Cd(II) in environmental water samples.  相似文献   

17.
A selective method has been developed for the extraction chromatographic trace level separation of Cu(II) with Versatic 10 (liquid cation exchanger) coated on silanised silica gel (SSG-V10). Cu(II) has been extracted from 0.1 M acetate buffer at the range of pH 4.0–5.5. The effects of foreign ions, pH, flow-rate, stripping agents on extraction and elution have been investigated. Exchange capacity of the prepared exchanger at different temperatures with respect to Cu(II) has been determined. The extraction equilibrium constant (Kex) and different standard thermodynamic parameters have also been calculated by temperature variation method. Positive value of ΔH (7.98 kJ mol−1) and ΔS (0.1916 kJ mol−1) and negative value of ΔG (−49.16 kJ mol−1) indicated that the process was endothermic, entropy gaining and spontaneous. Preconcentration factor was optimized at 74.7 ± 0.2 and the desorption constants Kdesorption1(1.4 × 10−2) and Kdesorption2(9.8 × 10−2) were determined. The effect of pH on Rf values in ion exchange paper chromatography has been investigated. In order to investigate the sorption isotherm, two equilibrium models, the Freundlich and Langmuir isotherms, were analyzed. Cu(II) has been separated from synthetic binary and multi-component mixtures containing various metal ions associated with it in ores and alloy samples. The method effectively permits sequential separation of Cu(II) from synthetic quaternary mixture containing its congeners Bi(III), Sn(II), Hg(II) and Cu(II), Cd(II), Pb(II) of same analytical group. The method was found effective for the selective detection, removal and recovery of Cu(II) from industrial waste and standard alloy samples following its preconcentration on the column. A plausible mechanism for the extraction of Cu(II) has been suggested.  相似文献   

18.
The present paper describes the synthesis of a new chemically modified cellulose microfiber through oxidation with sodium periodate and functionalization with N,N′-bis (2-aminoethyl)-1,2-ethanediamine for the fast and selective preconcentration of Cd(II) ions in flow system analysis. The new sorbentsorbent was characterized by FTIR, SEM, and surface area values. The uptake behavior of Cd(II) ions onto this sorbent was evaluated from kinetic data, pseudo-first-order and pseudo-second-order models, as well as from Langmuir, Freundlich and Langmuir-Freundlich adsorption isotherms. The maximum sorption capacity of 4.59 mg g−1 was estimated by the Langmuir-Freundlich model with fast kinetics for the sorption of Cd(II) described by the pseudo-second-order kinetic model. After characterization, the sorbent was packed in a mini-column, and a fast flow injection preconcentration system for Cd(II) determination by FAAS was developed. The best Cd(II) preconcentration condition, obtained by means of factorial design and response surface methodology, was achieved at pH 9.36 and a flow rate of 10 mL min−1 followed by elution with 1.0 mol L−1 nitric acid. By using 78 s preconcentration time, fast and highly sensitive determination of Cd(II) ions could be achieved with a limit of quantification of 0.20 μg L−1, preconcentration factor of 26, consumption index of 0.5 mL, concentration efficiency of 20 min−1, and sample throughput of 39 h−1. The repeatability for 10 replicate determinations was found to be 7.8 and 2.5% for Cd(II) ion concentrations of 5.0 and 100.0 μg L−1, respectively. The new sorbent efficiency for the interference-free preconcentration of Cd(II) ions was assessed by analysis of tap, mineral and lake waters, as well as synthetic seawater and normal saline waters. Furthermore, complex samples, such as biological samples, could be analysed by the proposed method in accordance with the accuracy attested by analysis of certified reference materials, TORT-2 (lobster hepatopancreas), and DOLT-4 (dogfish liver).  相似文献   

19.
A vapor generation procedure to determine Cd by atomic fluorescence spectrometry (AFS) has been established. Volatile species of Cd are generated by following reaction of acidified sample containing Fe(II) and l-cysteine (Cys) with sodium tetrahydroborate (NaBH4). The presence of 5 mg L−1 Fe(II) and 0.05% m/v Cys improves the efficiency of Cd vapor generation substantially about four-fold compared with conventional thiourea and Co(II) system. Three experiments with different mixing sequences and reaction times are designed to study the reaction mechanism. The results document that the stability of Cd(II)–Cys complexes is better than Cys–THB complexes (THB means NaBH4) while the Cys–THB complexes have more contribution to improve the Cd vapor generation efficiency than Cd(II)–Cys complexes. Meanwhile, the adding of Fe(II) can catalyze the Cd vapor generation. Under the optimized conditions, the detection limit of Cd is 0.012 μg L−1; relative standard deviations vary between 0.8% and 5.5% for replicate measurements of the standard solution. In the presence of 0.01% DDTC, Cu(II), Pb(II) and Zn(II) have no significant influence up to 5 mg L−1, 10 mg L−1and 10 mg L−1, respectively. The accuracy of the method is verified through analysis of the certificated reference materials and the proposed method has been applied in the determination of Cd in seafood and rice samples.  相似文献   

20.
The present work describes the development and application of a carbon paste electrode modified by treated-Pennisetum setosum for the determination of lead(II) by anodic stripping differential pulse voltammetry. Most experiments were performed using the preconcentration/voltammetry/regeneration scheme. The resulting modified electrode offers a preferential uptake of lead(II) from solutions. Operational conditions, such as percentage treated-Pennisetum loading in the carbon paste, pH of electrolyte solution, ionic strength, preconcentration time, voltammetric waveform and interference are characterized and optimized to allow quantitative determination of lead. The electrode surface can be regenerated by immersing the modified electrode in 0.05 mol l−1 hydrochloric acid for 2 min. For the measurement step, the optimum conditions were acetate buffer pH 5.0 and 0.60 ionic strength with the preconcentration time of 5 min. The modified electrode contained 10% (w/w) treated-Pennisetum. The detection limit (3σ) was 0.01 mg l−1 Pb(II). For 16 preconcentration/measurement/renewal cycles, the responses could be reproduced with a 5.39% relative standard deviation. This method has been be successfully applied to the determination of lead(II) in natural water samples using standard addition method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号