首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
Pai YF  Lin CC  Liu CY 《Electrophoresis》2004,25(4-5):569-577
A wall-coated histidine capillary column was developed for the on-line preconcentration of nonsteroidal anti-inflammatory drugs (NSAIDs) in capillary electrochromatography (CEC). A wide variety of experimental parameters, such as the sample buffer, background electrolyte (BGE) composition, concentration, sample plug lengths, water plug, and the effect of organic modifiers were studied. The relationship between peak height and injection times for the NSAIDs by variation of sample and BGE buffer concentration was investigated. On addition of sodium chloride (0.3-0.6%) to the sample zone, the stacking efficiency was increased. With acetate buffer (100 mM, pH 5.0)/ethanol (20% v/v) as BGE and sample solution in acetate buffer (0.2 mM, pH 5.0)/ethanol (20% v/v)/NaCl (0.3% w/v), NSAIDs could be determined at low microM levels without sample matrix removal. The detection limit was 0.096 microM for indoprofen, 0.110 microM for ketoprofen, 0.012 microM for naproxen, 0.023 microM for ibuprofen, 0.110 microM for fenoprofen, 0.140 microM for flurbiprofen, and 0.120 microM for suprofen. The method could be successfully applied to the simultaneous determination of NSAIDs in urine. The recoveries were better than 82% for all the analytes. The present method enables simple manipulation with UV detection for the determination of NSAIDs at low concentration levels in complex matrix samples.  相似文献   

2.
In capillary electrophoresis, it is commonly considered that even a moderately high ionic concentration in the background electrolyte (BGE) leads to high currents, resulting in Joule heating and serious peak distortion. As a new approach to overcome this problem, zwitterionic (Zwittergent-3-14) and/or non-ionic (Tween 20) surfactants have been added to BGEs containing high salt concentrations (e.g. 0.3 M NaCl) and have been shown to result in acceptable separation currents (<200 microA). In turn, these BGEs could be applied to the separation of samples containing high salt concentrations (such as undiluted seawater) without the occurrence of any significant peak broadening due to electrodispersion of the sample. For example, a BGE comprising 10 mM Zwittergent-3-14, 50 mM Tween 20, 0.3 M NaCl and 5 mM phosphate (ph 7) could be used for the determination of UV-absorbing anions in seawater, giving good peak shapes and detection limits of 0.8 microM and 0.6 microM for nitrate and bromide, respectively. The beneficial effects of the non-ionic surfactant on the separation were attributed largely to suppression of the electro-osmotic flow. On the other hand, the zwitterionic surfactant was found to be capable of the incorporation of some anions in accordance with the behaviour of these same surfactants in electrostatic ion chromatography. This incorporation resulted in a decreased conductivity of the BGE and also a change in the separation selectivity of the system.  相似文献   

3.
Capillary electrophoresis (CE) was applied to analyse the long-chain fatty acid composition of vegetable oils, and their degradation products formed upon ageing when drying oils are used as binding media. The analytes were detected with contactless conductivity detection (CCD) and indirect UV absorption, both detectors positioned on-line at the separation capillary. The long-chain fatty acids were resolved in a background electrolyte (BGE) consisting of phosphate buffer (pH = 6.86, 15 mM) containing 4 mM sodium dodecylbenzensulfonate, 10 mM Brij 35, 2% (v/v) 1-octanol and 45% (v/v) acetonitrile. As in this system dicarboxylic analytes, the products of oxidative degradation of unsaturated fatty acids, cannot be determined, a suitable background electrolyte was developed by the aid of computer simulation program PeakMaster. It makes use of a 10 mM salicylic acid, 20 mM histidine buffer, pH 5.85, which combines buffering ability with the optical properties obligatory for indirect UV detection. This buffer avoids system eigenpeaks, which are often impairing the separation efficiency of the system. Separation of the dicarboxylic analytes was further improved by a counter-directed electroosmotic flow (EOF), obtained by dynamically coating the capillary wall with 0.2 mM cetyltrimethylammonium bromide. Long-chain fatty acids and their decomposition products could be determined in recent and aged samples of drying oils, respectively, and in samples taken from two paintings of the 19th century.  相似文献   

4.
Five non‐steroidal anti‐inflammatory drugs, naproxen, fenoprofen, ketoprofen, diclofenac and piroxicam, were separated and analyzed by electrokinetic supercharging in CZE. Three different setups of the ITP technique were assayed for the separation and preconcentration of these five non‐steroidal anti‐inflammatory drugs. For the setup that gave the best results, we evaluated the influence of different parameters on separation and preconcentration efficiency such as sample pH, concentration of the leading stacker, BGE composition, electrokinetic injection time, composition and hydrodynamic injection of the solvent plug and of the terminating stacker. In the selected setup, the BGE (10 mM Na2B4O7 + 50 mM NaCl in 10% of MeOH aqueous solution) contained the leading electrolyte while the terminating electrolyte, hydrodynamically injected after the sample (50 mbar×12 s), was 50 mM of CHES. Prior to sample injection at (700 s at −2 kV) a short plug of MeOH (50 mbar ×3 s) was hydrodynamically injected. The results show that this strategy enhanced detection sensitivity 2000‐fold compared with normal hydrodynamic injection, providing detection limits of 0.08 μg/L for standard samples with good repeatability (values of relative standard deviation, %RSD < 1.03%). Method validation with river water samples and human plasma demonstrated good linearity, with detection limits of 0.9 and 2 μg/L for river water samples and human plasma samples, respectively (as well as satisfactory precision in terms of repeatability and reproducibility).  相似文献   

5.
Capillary zone electrophoresis (CZE) was used for characterisation of soil humic acid (HA) fractions obtained by coupling size-exclusion chromatography with polyacrylamide gel electrophoresis, on the basis of their molecular size and electrophoretic mobility. CZE was conducted using several low alkaline buffers as background electrolyte (BGE): 50 mM carbonate, pH 9.0; 50 mM phosphate, pH 8.5; 50 mM borate, pH 8.3; 50 mM Tris-borate+1 mM EDTA+7 M urea+0.1% sodium dodecyl sulphate (SDS), pH 8.3. Independently of BGE conditions, the effective electrophoretic mobility of HA fractions were in good agreement with their molecular size. The better resolution of HA were obtained in Tris-borate-EDTA buffer with urea and SDS. This results indicated that CZE, mostly with BGE-contained disaggregating agents, is useful for separating HAs in fractions with different molecular sizes.  相似文献   

6.
The separation, characterization, and determination of mixtures of alkyl ether sulfates (AES) and fatty acids (C10-C16) in background electrolytes (BGEs) containing acetonitrile (ACN)-water mixtures is addressed. Due to inhibition of the ionization of the carboxylate groups, the migration time and the resolution between the fatty acids decreased when the water content of the BGE was reduced, but efficiency and resolution between the AES oligomers improved. The migration times increased and resolution improved by substituting 5% ACN by an equivalent amount of dioxane. A complete separation of the two surfactant classes, up to the AES oligomers with 8 ethylene oxide units (EOs) with respect to C10, with excellent resolution between the AES oligomers, while preserving a satisfactory resolution between the fatty acids, was achieved with a BGE containing 5 mM trimethoxybenzoic acid, 7 mM dipentylamine, 85% ACN, 5% dioxane, and 10% water. The two surfactant classes were increasingly resolved by further reducing the water content of the BGE. Thus, C2 (acetate) was resolved from the AES oligomers up to 7 EOs using 90% ACN and 5% dioxane, but the resolution between the heavier fatty acids was poor with this BGE. Identification of the AES oligomers was eased by the excellent regularity of the successive migration times; thus, within each AES subclass or series of oligomers with the same number of carbon atoms in the alkyl chain, the migration times decreased following a mild curve as the number of EOs increased. The way how the data obtained by indirect photometry (corrected peak areas that are proportional to the molar concentrations) should be managed to avoid systematic error when the calibration curve is constructed using an AES standard with an oligomer distribution different from that of the samples is discussed and equations are given. Decyl sulfate was successfully used as internal standard. The detection limits (S/N = 3) were of ca. 2 microM for individual AES oligomers.  相似文献   

7.
A combination of MEKC with a—highly sensitive but not commonly used—LIF detector was tested regarding the possibility of differentiation of red inks. The separation process was conducted in a fused silica capillary (id 50 μm, 60/50 cm total/effective length) in BGE consisting of 40 mM sodium borate, 20 mM SDS and 10% v/v ACN with 30 kV applied. The optimized temperature of storage and capillary was 10 and 25°C, respectively. The samples were prepared using 20 dots (ø 0.5 mm), extracted in 35 μL BGE and diluted with 30 μL of water. The proposed method showed excellent repeatability and reproducibility (RSD (tm) < 0.8 and < 2.5%, respectively). It was applied to group identification and differentiation of different brands, models, and batches of red printing, stamp, and pen inks. It was demonstrated that differentiation can be performed effectively on the basis of migration times and ratios of peak areas. The high efficiency of the developed method was indicated by discriminating power ranging from 87.3 to 98.8%, for stamp and pen inks, respectively. The results showed that the proposed procedure can be valuable for an objective examination of the red parts of questioned documents.  相似文献   

8.
In this article, optimization of BGE for simultaneous separation of inorganic ions, organic acids, and glutathione using dual C4D‐LIF detection in capillary electrophoresis is presented. The optimized BGE consisted of 30 mM 2‐[4‐(2‐hydroxyethyl)piperazin‐1‐yl]ethanesulfonic acid, 15 mM 2‐amino‐2‐hydroxymethyl‐propane‐1,3‐diol, and 2 mM 18‐crown‐6 at pH 7.2 and allowed simultaneous separation of ten inorganic anions and cations, three organic acids and glutathione in 20 min. The samples were injected hydrodynamically from both capillary ends using the double‐opposite end injection principle. Sensitive detection of anions, cations, and organic acids with micromolar LODs using C4D and simultaneously glutathione with nanomolar LODs using LIF was achieved in a single run. The developed BGE may be useful in analyses of biological samples containing analytes with differing concentrations of several orders of magnitude that is not possible with single detection mode.  相似文献   

9.
A capillary electrophoretic method with UV detection for separation and quantitation of perfluorocarboxylic acids (PFCAs) from C6-PFCA to C12-PFCA has been developed. The optimization of measurement conditions included the choice of the most appropriate type and concentration of buffer in the background electrolyte (BGE), as well as the type and the content of an organic modifier. The optimal separation of investigated PFCAs was achieved with 50 mM phosphate buffer and 40% isopropanol in the BGE using direct UV detection. The optimum wavelength for direct UV detection was optimized at 190 nm. For indirect detection, several chromophores were studied. Five mM 3,5-Dinitrobenzoic acid (3,5-DNBA) in 20 mM phosphate buffer BGE and indirect UV detection at 280 nm gave the optimal detection and separation performance for the investigated PFCAs. The possibility of on-line preconcentration of solutes by stacking has been examined for indirect detection. The detection limits (LODs) determined for direct UV detection ranged from 2 microg/mL for C6-PFCA to 33 microg/mL for C12-PFCA. The LODs obtained for indirect UV detection were comparable to those obtained for direct UV detection.  相似文献   

10.
Summary Amino acids in extracts of plant tissue were separated and detected by capillary zone electrophoresis (CZE) with indirect UV detection. Various aromatic carboxylates such as salicylate, benzoate, phthalate and trimellitate were investigated as background electrolytes (BGEs). A BGE of benzoate gave the best resolution and detector response. Amino acids were separated at a highly alkaline pH to charge amino acids negatively. Separation was achieved by the co-electroosmotic flow (Co-EOF) by the addition of the cationic surfactant myristyltrimethyl-ammonium bromide (MTAB) to the electrolyte. The condtions affecting the separation of amino acids, including electrolyte pH, concentrations of both benzoate and MTAB, were investigated and optimised. Separation of a mixture of 17 amino acids at pH 11.20 with indirect UV detection at 225 nm was achieved with a BGE of 10 mM benzoate containing 1.0 mM MTAB at pH of 11.20. Detection limits ranged between 10 and 50 μM. The proposed method was demonstrated by the determination of amino acids in extracts of Eucalypt leaves with direct injection of samples.  相似文献   

11.
Several commercial immobilized metal affinity chromatography sorbents were evaluated in this study for the analysis of two small peptide fragments of the amyloid β‐protein (Aβ) (Aβ(1–15) and Aβ(10–20) peptides) by on‐line immobilized metal affinity SPE‐CE (IMA‐SPE‐CE). The performance of a nickel metal ion (Ni(II)) sorbent based on nitrilotriacetic acid as a chelating agent was significantly better than two copper metal ion (Cu(II)) sorbents based on iminodiacetic acid. A BGE of 25 mM phosphate (pH 7.4) and an eluent of 50 mM imidazole (in BGE) yielded a 25‐fold and 5‐fold decrease in the LODs by IMA‐SPE‐CE‐UV for Aβ(1–15) and Aβ(10–20) peptides (0.1 and 0.5 μg/mL, respectively) with regard to CE‐UV (2.5 μg/mL for both peptides). The phosphate BGE was also used in IMA‐SPE‐CE‐MS, but the eluent needed to be substituted by a 0.5% HAc v/v solution. Under optimum preconcentration and detection conditions, reproducibility of peak areas and migration times was acceptable (23.2 and 12.0%RSD, respectively). The method was more sensitive for Aβ(10–20) peptide, which could be detected until 0.25 μg/mL. Linearity for Aβ(10–20) peptide was good in a narrow concentration range (0.25–2.5 μg/mL, R2 = 0.93). Lastly, the potential of the optimized Ni(II)‐IMA‐SPE‐CE‐MS method for the analysis of amyloid peptides in biological fluids was evaluated by analyzing spiked plasma and serum samples.  相似文献   

12.
The ratio of citric acid to D ‐isocitric acid can be used to distinguish authentic and adulterated fruit juices. To separate DL ‐isocitric acid enantiomers, we used ligand exchange CE. D ‐Quinic acid was used as a chiral selector ligand and Mn(II), Fe(III), Co(II), Ni(II), Cu(II), and Zn(II) ions were used as the central ions of the chiral selector in the BGE. DL ‐Isocitric acid was found to be enantioseparated with the above metal ions except for Mn(II) ion. The optimum running conditions for the analysis of D ‐ and L ‐isocitric acids along with citric acid, an isomer of isocitric acid, were found to be a BGE (pH 5.0) containing 30% ACN, 20 mM acetic acid, 20 mM NiSO4, and 80 mM D ‐quinic acid. Under these conditions, DL ‐isocitric and citric acids in fruit juices were analyzed successfully.  相似文献   

13.
Gotti R  Fiori J  Mancini F  Cavrini V 《Electrophoresis》2005,26(17):3325-3332
Nitromusks used as fragrances in a variety of personal-care products, cleansers, and domestic deodorants, including incense sticks, are neutral nitro aromatic compounds; some of these have been reported as photosensitizers. In this work, their analysis was performed by capillary electrophoresis (CE) in a methanol-based background electrolyte (BGE). In particular, a 10 mM solution of citric acid in methanol was used; under these conditions the strong suppression of the electroosmotic flow favored the use of negatively charged surfactants as additives for the anodic migration of the studied analytes. To this end, sodium taurodeoxycholate (TDC) was supplemented at high concentration (190 mM) to the organic background electrolyte (BGE), showing strong indication of the ability to give micelle-like aggregates. Since nitromusks are characterized by the presence of a nitroaromatic ring with low charge density, their association with TDC aggregates can be ascribed to donor-acceptor interactions. Separation of musk xylene, musk ketone, and the banned musk moskene and musk ambrette was obtained under full nonaqueous BGE; the addition of relatively small water percentages (15% v/v) was found to be useful in improving the separation of pairs of adjacent peaks. Under optimized conditions (190 mM sodium TDC in methanol-water, 85-15 v/v containing citric acid 10 mM) the system was applied to the analysis of nitromusks in incense sticks extracted with methanol. The results were compared with those obtained by the analysis of the same samples using gas chromatography with mass detector. The expected different selectivity of separation obtained using the two techniques can be useful in the unambiguous determination of the analytes; furthermore, a substantial accord of the preliminary quantitative results achieved with the two methods was assumed as the confirmation of the potential reliability of CE performed with high percentage of organic solvent.  相似文献   

14.
A method has been developed for the analysis of the antidepressant drug sertraline together with its main metabolite N-desmethylsertraline (DMS) in human plasma. It is based on CE with LIF detection (lambda = 488 nm). A SPE procedure is employed for biological sample pretreatment, followed by a derivatization step with FITC; reboxetine was the internal standard. The effect of CD, acetone and N-methyl-D-glucamine (GLC) as constituents of the BGE for analyte separation was investigated. The final BGE consisted of 20 mM carbonate buffer, pH 9.0, with 2.5 mM heptakis(2,6-di-O-methyl)-beta-CD, 50 mM GLC and 20% v/v acetone. With 30 kV applied voltage, the electrophoretic run is completed in 7.5 min. Linearity was observed in the plasma concentration range from 3.0 to 500 ng/mL for sertraline and 4.0 to 500 ng/mL for DMS. Extraction yield was >97.1%, precision - expressed as RSD% - was <3.7, accuracy (recovery) was >95.6%. Due to its sensitivity and selectivity, the method was suited for the analysis of plasma samples from patients undergoing therapy with sertraline.  相似文献   

15.
A method based on micellar electrokinetic chromatography (MEKC) with UV detection has been developed for the determination of nine 5-nitroimidazoles (5-NDZs), including metabolites in river water samples. Due to the relative insensitivity of UV detection in MEKC, a solid-phase extraction (SPE) method has been proposed that preconcentrates water samples fiftyfold and cleans them up off-line. An on-line preconcentration approach based on sweeping and the use of an extended light path fused-silica capillary (64.5?cm?×?50?μm i.d., 56?cm effective length) was also found to improve the sensitivity of the method. Separation was carried out in <21?min using 20?mM phosphate buffer (pH 6.5) and 150?mM SDS as the background electrolyte (BGE). The temperature of the capillary was kept constant at 20°C, a voltage of 25?kV was applied (normal mode), and a detected wavelength of 320?nm was utilized. Hydrodynamic injection (50?mbar for 15?s) of the samples, which were dissolved in 20?mM phosphate (pH 6.5), was employed. The limits of detection were lower than 1.1?μg?L(-1). Recoveries of >80% from spiked river water samples were obtained for most of the analytes at three different concentration levels with acceptable precision. This method could provide an efficient and economical alternative to the use of chromatographic methods to monitor nitroimidazole residues, thus supplementing the relatively few methods available for the analysis of these compounds in environmental samples.  相似文献   

16.
Capillary zone electrophoresis (CZE) with indirect UV detection was developed for the simultaneous determination of inorganic anions and organic acids in environmental samples. Various aromatic acids (benzoic, phthalic, trimellitic, and pyromellitic acids) were evaluated as background electrolytes (BGEs) to give high resolution and detection sensitivity. Co-electroosmotic conditions such as the concentration of BGE, electrolyte pH, and EOF modifier were systematically investigated. Three inorganic anions and ten organic acids were determined simultaneously in 10 min using an electrolyte containing 10 mM phthalic acid, 0.5 mM myristyltrimethylammonium bromide (MTAB), and 5% methanol (MeOH) (v/v) at pH 5.60. Linear plots for the test solutes were obtained in the concentration range 0.01–1.0 mM with detection limits in the range 5–30 μM. The proposed method was successfully demonstrated for the determination of inorganic anions and organic acids in natural water, soil, and plant extracts after direct sample injection.  相似文献   

17.
N,N'-Alkylmethylimidazolium cations have been separated in NACE when one of the N,N'-dialkylimidazolium salts (ionic liquids (ILs)) was used as an electrolyte additive to the organic solvent separation medium. The separated species were 1-methyl-, 1-ethyl-, 1-butyl-, 1-octyl-, 1-decyl-3-methylimidazolium and N-butyl-3-methylpyridinium cations and BGE composed of 1-ethyl-3-methylimidazolium ethylsulfate or 1-butyl-3-methylimidazolium trifluoroacetate [BMIm][FAcO] (A6; B2) diluted in ACN. It was demonstrated that contactless conductivity detection (CCD) may be applied to monitoring the separation process in nonaqueous separation media, allowing to use the UV light-absorbing imidazolium-based electrolyte additives. There could be marked three concentration regions of added ILs; at first ionic strength of BGE below 1-2 mM, and then the actual electrophoretic mobility of analytes rises from 0. At concentrations above 1-2 mM, the added IL facilitated separation. In concentration region of 1-20 mM, the actual electrophoretic mobility of analyzed imidazolium cations was increasing with decrease in separation medium ionic strength. At higher concentrations of BGE (above 30 mM), the conductivity of the separation media became too high for this detector. Some organic dyes were also successfully separated and detected by contactless conductivity detector in a 20 mM A6 separation electrolyte in ACN.  相似文献   

18.
Paliperidone is a new antipsychotic drug with a relatively low therapeutic concentration of 20–60 ng/mL. We established an accurate and sensitive CE method for the determination of paliperidone concentrations in human plasma in this study. To minimize matrix effect caused by quantification errors, paliperidone was extracted from human plasma using Oasis HLB SPE cartridges with three‐step washing procedure. To achieve sensitive quantification of paliperidone in human plasma, a high‐conductivity sample solution with sweeping‐MEKC method was applied for analysis. The separation is performed in a BGE composed of 75 mM phosphoric acid, 100 mM SDS, 12% acetonitrile, and 15% tetrahydrofuran. Sample solution consisted of 10% methanol in 250 mM phosphoric acid and the conductivity ratio between sample matrix and BGE was 2.0 (γ, sample/BGE). The results showed it able to detect paliperidone in plasma samples at concentration as low as 10 ng/mL (S/N = 3) with a linear range between 20 and 200 ng/mL. Compared to the conventional MEKC method, the sensitivity enhancement factor of the developed sweeping‐MEKC method was 100. Intra‐ and interday precision of peak area ratios were less than 6.03%; the method accuracy was between 93.4 and 97.9%. This method was successfully applied to the analysis of plasma samples of patients undergoing paliperidone treatment.  相似文献   

19.
A method for the resolution of a peptides mixture including hepcidin‐25, an iron metabolism marker, was developed by CE‐ESI‐MS. Several strategies were tested to optimize peptide separation, such as the addition of cyclodextrins or organic solvents in the BGE or the use of coated capillaries. Best results in terms of resolution, symmetry and efficiency were obtained with a BGE made of 500 mM ammonium acetate pH 4.5/ACN 70:30 v/v. Using the methodology of experimental design, BGE concentration, sheath liquid composition and MS‐coupling parameters were then optimized in order to obtain the best signal intensity for hepcidin. Finally, a 225 mM BGE and a sheath liquid composed of isopropanol/water 80:20 v/v containing 0.5% v/v formic acid were selected as it constitutes the best compromise for selectivity, peak shape and sensitivity.  相似文献   

20.
Capillary electrophoresis with diode array detection (DAD) was used to determine uric acid (UA) in chicken plasma and the allantoic fluid of chicken embryos. Complete separation of uric and ascorbic acids was attained in less than 10 min in the optimized BGE containing 60 mM MES + 30 mM Tris + 0.001% (w/v) polybrene (pH 6.1). The limit of UA detection (0.2 mg/L) was found to be low enough for sensitive analysis of native plasma and allantoic fluid samples. Range of linearity (1-200 mg/L), repeatability for peak area (CV <4.1%) and migration time (CV < 2.5%), as well as recovery of UA from biological samples (97-100%), were found to be satisfactory. The method was applied to detect the elevated UA concentrations (hyperuricemia) in chicken embryos with induced unilateral renal agenesis. CE/DAD analysis of the chicken plasma can be carried out with a relatively small volume of samples (1 microL).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号