首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A liquid chromatographic (LC) method for the analysis of sulfamethazine (SMT) in complete swine and cattle feed was collaboratively studied. The method uses post-column derivatization with dimethylaminobenzaldehyde and detection at 450 nm. To 5g finely ground feed, extractant (0.2N HCl + 1.5% diethylamine in 25% methanol), and internal standard solutions are added, and the SMT is extracted by shaking for 1 h. Clarified extract (high-level sample extract diluted to a target concentration of ca 5.5 microg/mL) is chromatographed on a Cla reversed-phase LC column with acetonitrile-2% acetic acid (17 + 83) mobile phase. Sulfamerazine is used as an internal, or surrogate standard to correct for variable recovery of sulfamethazine from a variety of feed matrixes. Six Youden matched-pair samples were sent to 10 collaborators in Korea, Canada, and the United States. Label claims on the commercial feeds ranged from 0.0077 to 0.22% SMT. The SMT mean recovery as determined from the 5 samples with known analyte content was 99.8%. The within-laboratory relative standard deviation (repeatability) ranged from 0.28 to 4.72%. Among-laboratory (including within-laboratory) relative standard deviation (reproducibility) ranged from 1.26 to 4.87%. The authors recommend the method for AOAC INTERNATIONAL Official First Action status.  相似文献   

2.
A single-laboratory validation (SLV) and a ring trial (RT) were undertaken to determine nine nutritional elements in food products by inductively coupled plasma-optical emission spectrometry in order to modernize AOAC Official Method 984.27. The improvements involved extension of the scope to all food matrixes (including infant formula), optimized microwave digestion, selected analytical lines, internal standardization, and ion buffering. Simultaneous determination of nine elements (calcium, copper, iron, potassium, magnesium, manganese, sodium, phosphorus, and zinc) was made in food products. Sample digestion was performed through wet digestion of food samples by microwave technology with either closed- or open-vessel systems. Validation was performed to characterize the method for selectivity, sensitivity, linearity, accuracy, precision, recovery, ruggedness, and uncertainty. The robustness and efficiency of this method was proven through a successful RT using experienced independent food industry laboratories. Performance characteristics are reported for 13 certified and in-house reference materials, populating the AOAC triangle food sectors, which fulfilled AOAC criteria and recommendations for accuracy (trueness, recovery, and z-scores) and precision (repeatability and reproducibility RSD, and HorRat values) regarding SLVs and RTs. This multielemental method is cost-efficient, time-saving, accurate, and fit-for-purpose according to ISO 17025 Norm and AOAC acceptability criteria, and is proposed as an extended updated version of AOAC Official Method 984.27 for fortified food products, including infant formula.  相似文献   

3.
A candidate LC method proposed by the Expert Review Panel (ERP) for ractopamine was evaluated in a single-laboratory validation (SLV) study. The matrixes examined included bovine liver, kidney, muscle, and fat; swine liver, kidney, muscle, and fat; and turkey liver and muscle. Solution standards were shown to provide a linear response with an unweighted regression. The method demonstrated acceptable precision (HorRat, values 0.25 to 1.38) and recovery (75.4 to 88.8%) in all fortified matrixes. Method precision was verified with incurred residue tissues (bovine liver, kidney, and muscle; swine liver, kidney, and muscle; and turkey liver and muscle), which yielded RSDr values below 16% for all tissues and below 7% for most tissues. Estimated LOQ values ranged from 1.8 to 20.7 ng/g and support the utility of the method in the range of the maximum residue limits or tolerances for the various tissues. The data satisfy the requirements of the AOAC Stakeholder Panel on Veterinary Drug Residue for SLV studies, and the method was adopted Official Methods ofAnalysis First Action 2011.22 by the AOAC ERP on Veterinary Drug Residues.  相似文献   

4.
AOAC Official Method(SM) 2005.06 for the determination of saxitoxin (STX)-group toxins in shellfish by LC with fluorescence detection with precolumn oxidation was previously validated and adopted First Action following a collaborative study. However, the method was not validated for all key STX-group toxins, and procedures to quantify some of them were not provided. With more STX-group toxin standards commercially available and modifications to procedures, it was possible to overcome some of these difficulties. The European Union Reference Laboratory for Marine Biotoxins conducted an interlaboratory exercise to extend AOAC Official Method 2005.06 validation for dc-GTX2,3 and to compile precision data for several STX-group toxins. This paper reports the study design and the results obtained. The performance characteristics for dc-GTX2,3 (intralaboratory and interlaboratory precision, recovery, and theoretical quantification limit) were evaluated. The mean recoveries obtained for dc-GTX2,3 were, in general, low (53.1-58.6%). The RSD for reproducibility (RSD(r)%) for dc-GTX2,3 in all samples ranged from 28.2 to 45.7%, and HorRat values ranged from 1.5 to 2.8. The article also describes a hydrolysis protocol to convert GTX6 to NEO, which has been proven to be useful for the quantification of GTX6 while the GTX6 standard is not available. The performance of the participant laboratories in the application of this method was compared with that obtained from the original collaborative study of the method. Intralaboratory and interlaboratory precision data for several STX-group toxins, including dc-NEO and GTX6, are reported here. This study can be useful for those laboratories determining STX-group toxins to fully implement AOAC Official Method 2005.06 for official paralytic shellfish poisoning control. However the overall quantitative performance obtained with the method was poor for certain toxins.  相似文献   

5.
Data from a recent interlaboratory study of the determination of water (moisture) in animal feed, grain, and forage (plant tissue) by Karl Fischer titration were re-analyzed using Youden plots. The purpose was to show the unique ability these plots possess of separating random and systematic errors visually while providing numerical estimates of the precision and the systematic error of the method. Furthermore, the usefulness of the technique is underscored because AOAC INTERNATIONAL allows the use of matched pairs in collaborative studies to obtain estimates of repeatability and reproducibility.  相似文献   

6.
During the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting" held on June 29, 2011, an Expert Review Panel (ERP) on behalf of AOAC INTERNATIONAL adopted the method "Simultaneous Determination of Vitamins D2 and D3 by LC-MS/MS in Infant Formula and Adult Nutritionals" as an AOAC Official First Action method. Vitamins D2 and D3 are extracted from the sample using pentane-ether; the extract is collected and dried under nitrogen. Vitamin D is separated from interfering compounds using UPLC, and quantitated using tandem mass spectrometry (MS/MS). Preliminary data showed the intermediate precision ranged from 3.34-8.05% and an accuracy range of 98.5-111% over the samples tested for vitamin D3. For vitamin D2, the intermediate precision ranged from 2.37-5.45% and accuracy ranged from 96.4-104% over the four matrixes evaluated. The analytical range for the method is bounded by the concentrations of the working standards, 21-270 ng/mL, and is equivalent to 0.168-2.16 mcg/100 g in ready-to-feed product. The practical method quantitation limit is 0.168 mcg/100 g product with method detection limit of 60 ng/100 g product. The ERP reviewed the data and determined that the performance characteristics of the method met the standard method performance requirements, and therefore the method was granted First Action status.  相似文献   

7.
A convenient method was developed for determination of sulfathiazole (STZ) in Type C medicated swine feed by reversed-phase liquid chromatography (LC) with post-column derivatization. Addition of extractant solution (0.2N HCl and 1.5% diethylamine in 25% methanol) and an internal standard (IS), sulfamethylthiazole (SMZ), to 5 g sample was followed by mechanical shaking for 1 h. The extract was clarified by chilling, centrifugation, and filtering before injection onto a C18 reversed-phase column. The mobile phase components were 2% acetic acid and 1:1 acetonitrile-methanol (83 + 17%, v/v). Run time was about 20 min. Determination and, largely, the method's selectivity were based on detection at 450 nm of the derivative formed by the post-column reaction of dimethylaminobenzaldehyde with the primary amine of the analyte and IS. The IS, SMZ, differs from STZ by a single substituent methyl group, is stable, and is readily resolved from STZ. Although SMZ is not commercially available, it can be synthesized with relative ease from purchased reagents and will be supplied by the authors to interested laboratories. In single-laboratory validation, linearity was demonstrated over the range of 0.055-550 microg/mL, well beyond the target concentration of 5.5 microg/mL. The estimated limit of detection was 0.04 microg/mL; the calculated limit of quantitation was 0.13 microg/mL (feed concentration of 2.4 g/T or 2.7 mg/kg). Wet-spiking trials with a variety of swine feed matrixes showed recovery to be 100-102% for the intended concentration range, 50-200 g/T, with coefficient of variation (CV) < 2%. The method ruggedness was verified with an overall CV of 2.9%.  相似文献   

8.
A collaborative study was performed to determine the reproducibility of a method for the determination of methylcellulose (MC) and hydroxypropyl methylcellulose (HPMC) in food. These widely used food gums possess unusual solubility characteristics and cannot accurately be determined by existing dietary fiber methods. The new method uses the enzyme-digestion procedure of AOAC Official Method 991.43. Digestate solutions must be refrigerated to fully hydrate MC or HPMC. The chilled solutions are filtered and analyzed by size-exclusion liquid chromatography. Collaborating laboratories received 28 samples containing MC or HPMC in the range of 0-100%. The sample set included blind duplicates of 5 food matrixes (bread, milk, fish, potato, and powdered juice drink). Cochran and Grubbs tests were used to eliminate outliers. For food samples containing MC, values for within-laboratory precision, repeatability relative standard deviation (RSDr), ranged from 4.2 to 16%, and values for among-laboratories precision, reproducibility relative standard deviation (RSDR), ranged from 11 to 20%. For HPMC samples, RSDr values ranged from 6.4 to 27%, and RSDR values ranged from 17 to 39%. Recoveries of MC and HPMC from the food matrixes ranged from 78 to 101%. These results show acceptable precision and reproducibility for the determination of MC and HPMC, for which no Official AOAC Methods exist. It is recommended that this method be adopted as AOAC Official First Action.  相似文献   

9.
A single laboratory validation (SLV) was completed for a method to determine the flavonol aglycones quercetin, kaempferol, and isorhamnetin in Ginkgo biloba products. The method calculates total glycosides based on these aglycones formed following acid hydrolysis. Nine matrixes were chosen for the study, including crude leaf material, standardized dry powder extract, single and multiple entity finished products, and ethanol and glycerol tinctures. For the 9 matrixes evaluated as part of this SLV, the method appeared to be selective and specific, with no observed interferences. The simplified 60 min oven heating hydrolysis procedure was effective for each of the matrixes studied, with no apparent or consistent differences between 60, 75, and 90 min at 90 degrees C. A Youden ruggedness trial testing 7 factors with the potential to affect quantitative results showed that 2 factors (volume hydrolyzed and test sample extraction/hydrolysis weight) were the most important parameters for control during sample preparation. The method performed well in terms of precision, with 4 matrixes tested in triplicate over a 3-day period showing an overall repeatability (relative standard deviation, RSD) of 2.3%. Analysis of variance testing at alpha = 0.05 showed no significant differences among the within- or between-group sources of variation, although comparisons of within-day (Sw), between-day (Sb), and total (St) precision showed that a majority of the standard deviation came from within-day determinations for all matrixes. Accuracy testing at 2 levels (approximately 30 and 90% of the determined concentrations in standardized dry powder extract) from 2 complex negative control matrixes showed an overall 96% recovery and RSD of 1.0% for the high spike, and 94% recovery and RSD of 2.5% for the low spike. HorRat scores were within the limits for performance acceptability, ranging from 0.4 to 1.3. Based on the performance results presented herein, it is recommended that this method progress to the collaborative laboratory trial.  相似文献   

10.
An improved method for extraction and analysis of tiamulin is presented to address issues that arose during routine analysis of Type C medicated swine feeds under the current U.S. Food and Drug Administration-Center for Veterinary Medicine (FDA-CVM) approved method. The issues included the need for higher sample throughput and the ability to accommodate a wider variety of feed matrixes. Changes to the FDA-CVM approved method include reduced sample size and solvent volumes, phosphate buffering of tartaric acid, centrifugation, and use of a new liquid chromatography column and adjusted mobile phase composition. A paired sample study was performed to compare performance of the new and existing methods. The paired sample study showed no statistical difference between sample means of paired sets of 17 samples analyzed by both methods (t = 1.95 at 0.05 significance level, p = 0.068). A recovery study showed the method precision to be 2.06% (coefficient of variation) with an average standard recoveryof 95.8%. Ruggedness test results indicated good overall ruggedness of the method.  相似文献   

11.
At the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting" on June 29, 2011, an Expert Review Panel (ERP) agreed to further examine AOAC Official Method 2011.01, "Determination of Vitamin B12 by Surface Plasmon Resonance," for use with infant formula and adult nutritionals. The original collaborative study was conducted using the Biacore Q biosensor instrument and the Biacore Q Qflex Kit Vitamin B12 PI. Samples included in the study were infant formula, cereals, premixes, vitamin tablets, dietary supplements, and baby food. Eleven laboratories participated in the collaborative study. The results demonstrated a repeatability RSD (RSDr) of 1.59-27.8 and HorRat values for reproducibility of 0.34-1.89 in samples with levels ranging from ppm to ppb. The assay studied is a label-free protein binding-based assay that uses the principle of surface plasmon resonance to measure the interaction between vitamin B12 and a specific binding protein by passing a portion of the prepared sample extract combined with binding protein solution across a functionalized sensor chip. The response from the functionalized sensor chip is given as free-binding protein, as the mixture binds to the prepared surface of the chip. The ready-to-use Qflex Kit Vitamin B12 PI provides the reagents and accessories necessary to perform this assay. AOAC Method 2011.01 was approved by the AOAC Method Committee on Food Nutrition for Official First Action status, applicable to a wide range of food products, dietary supplements, and multivitamin premixes. After evaluation of the validation data available, an ERP agreed in June 2011 that the method meets standard method performance requirements, as articulated by the Stakeholder Panel on Infant Formula and Adult Nutritionals. The ERP granted the method First Action status, applicable to infant formula and adult/pediatric nutritional formula.  相似文献   

12.
The applicability of AOAC Official Method 992.06, vitamin A (retinol) in milk-based infant formula can be extended to specialty infant formulas, and medical and adult nutritional products with a few minor modifications to the sample preparation procedure. Currently, AOAC Official Method 992.06 is only applicable to milk-based infant formulas containing >500 IU vitamin A per reconstituted quart. When this method is used as written to test specialty infant formulas, vitamin A recoveries are low compared to results generated with alternate validated vitamin A methods. AOAC Method 992.06 vitamin A recoveries can be improved significantly in specialty infant formulas if the amount of potassium hydroxide used during the saponification step is doubled. With this one minor modification to the sample preparation procedure, AOAC Method 992.06 demonstrates acceptable precision and accuracy for the quantitation of vitamin A (retinol) in specialty infant formulas, milk- and soy-based infant formulas, and adult and medical nutritionals. Because increasing the amount of potassium hydroxide can cause emulsions to form, 2-4 mL aliquots of reagent alcohol may need to be added to some samples to separate the organic and aqueous layers during the extraction step. A single-laboratory validation of these modifications was completed. During validation, 15 different product matrixes were analyzed. The intermediate precision averaged 2.70% RSD, and spike recovery data averaged 96.3%.  相似文献   

13.
A liquid chromatographic method for the determination of sulfachloropyridazine, sulfadiazine, sulfadimethoxine, sulfadoxine, sulfaethoxypyridazine, sulfamethazine, sulfaquinoxaline, and sulfathiazole residues in the muscle, liver, and kidney of food animals using sulfapyridine as internal standard is reported. Tissues are extracted using a modified version of AOAC Official Method 983.31 (Sulfonamide Residues in Animal Tissues). The sample extract is reconstituted in pH 3.0 buffer-acetonitrile (60 + 40) and filtered into an autosampler vial. Using a programmable autosampler of a liquid chromatograph, a portion of the sample is derivatized precolumn with fluorescamine. The sulfonamide derivatives are separated by liquid chromatography using a C18 column with a mobile phase of 0.02M phosphoric acid-acetonitrile (60.5 + 39.5) and detected by fluorescence (excitation, 405 nm; emission, 495 nm). The method was applied to swine and cattle muscle, liver, and kidney; sheep and horse muscle and kidney; and chicken muscle and liver. The mean values for samples fortified with sulfonamides at levels between 0.05 and 0.2 microg/g agreed within 96-99% of spiked levels, with coefficients of variation ranging from 4-10%. The limit of detection (LOD) for all sulfonamides was 0.01 microg/g, with the exception of sulfaquinoxaline, for which the LOD was 0.015 microg/g.  相似文献   

14.
A method for determination of riboflavin in animal feeds using liquid chromatography (LC) was developed for feed samples fortified with riboflavin at 1 mg/lb or greater (up to 10,000 mg/lb). Feed samples were extracted in 0.1 N HCl with heating on a steam bath for 30 min, followed immediately by mechanical shaking for 30 min. Sample extracts were diluted to target volume with 2% acetic acid and filtered; riboflavin was determined by LC on a reversed-phase C18 column with 2% acetic acid-acetonitrile (85 + 15) mobile phase for separation and fluorescence detection with excitation at 460 nm and emission at 530 nm. The extraction was compared with that of the AOAC Official Method for riboflavin in food and feed premixes. The 2 method extractions were not significantly different from each other at the 95% confidence level. The developed method also had good linearity over 4 orders of magnitude, recovery of 95-99% from spiked feed samples, a limit of detection of riboflavin at 0.00034 microg/mL in solution, a limit of quantitation of 0.023 mg/lb in feed, and good ruggedness.  相似文献   

15.
Six foods representative of a wide variety of processed, dried powder processed, and raw food types were analyzed by the Visual Immunoprecipitate Assay (VIP) for Salmonella and AOAC INTERNATIONAL culture method. Paired samples of each food type were simultaneously analyzed; one sample by the VIP method and one by the AOAC culture method. A total of 24 laboratories representing federal government agencies and private industry, in the United States and Canada, participated in this collaborative study. Food types were inoculated with species of Salmonella with the exception of raw ground chicken, which was naturally contaminated. No statistical differences (p < 0.05) were observed between VIP for Salmonella interpretation and the AOAC culture method for any inoculation level of any food type or naturally contaminated food. The method was adopted Official First Action status by AOAC INTERNATIONAL.  相似文献   

16.
Responding to a need for a guide for conducting Official Method validation studies of microbiological methods, AOAC utilized the experience of three microbiologists who have been active in the field of method validation. In collaboration, a document was prepared which covered the following areas: terms and their definitions associated with the Official Methods program (e.g., reference methods, alternative methods, and ruggedness testing), protocols and validation requirements for qualitative methods versus those for quantitative methods, the concept of the precollaborative study, ruggedness testing, tests for significant differences, performance indicators, and the approval process. After its preparation, this document was reviewed by the members of the Methods Committee on Microbiology and Extraneous Materials and by members of the Official Methods Board. Herein is presented the approved version of that document.  相似文献   

17.
The validation of a novel liquid chromatographic (LC) method for the determination of pyrantel tartrate in feed is presented. The method provides a significant improvement over the efficiency and precision of AOAC Official Method 978.30. The method was shown to be accurate, precise, linear, and robust for medicated articles. Unlike the official method, the LC method was shown to be a superior stability-indicating method. After the method was validated by using laboratory blends, the effectiveness of the method was demonstrated with marketed product as well.  相似文献   

18.
AOAC INTERNATIONAL currently permits investigators to use the Youden Matched-Pairs Procedure to obtain estimates of the method performance indicators repeatability and reproducibility (S(r) and SR, respectively). This report explains the statistical model assumptions upon which the procedure is based, provides validity tests for several of these assumptions, explains conditions under which Youdens' "precision error" is not consistent with precision estimate S(r) or SR as defined by AOAC INTERNATIONAL, and indicates when precision estimates based on the procedure should be interpreted with caution or should not be used.  相似文献   

19.
The method for the "Determination of Vitamins D2 and D3 in Infant Formula and Adult Nutritionals by Ultra-Pressure Liquid Chromatography with Tandem Mass Spectrometry Detection (UPLC-MS/MS)" was adopted as AOAC Official First Action during the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting" held June 29, 2011. During the meeting, an Expert Review Panel (ERP) evaluated the available validation information against standard method performance requirements (SMPRs) articulated by stakeholders. The method, approved by the ERP, is applicable for the determination of vitamin D (total vitamins D2 and D3). A range of products had been tested during a single-laboratory validation study. The products included butter, National Institute of Standards and Technology SRM 1849, eggs, cheese, yogurt, ready-to-eat cereal, bread, mushrooms, and tuna. The testing of the method established linearity in the range of 0.005-50 microg/mL. The recovery range was 93.4-100.9% for vitamin D2 and 102.4-106.2% for vitamin D3. The LOD and LOQ for vitamin D2 were reported as 0.20 and 0.61 microgl100 g, respectively; for vitamin D3, the reported values were 0.47 and 1.44 microg/100 g, respectively. The method met the SMPRs set by the Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN). It was, therefore, decided that the method was appropriate for Official First Action Method status.  相似文献   

20.
The U.S. Environmental Protection Agency's (EPA) Office of Pesticide Programs (OPP) has the responsibility for regulating antimicrobial products, including sporicides, used to treat and decontaminate inanimate surfaces. In response to the anthrax (Bacillus anthracis) attacks of 2001 and the associated need for verifying the performance of chemicals for building decontamination, the EPA initiated research in late 2003 to evaluate and improve efficacy test methods for sporicides. The OPP Microbiology Laboratory located at the Environmental Science Center, Ft. Meade, MD is the lead laboratory. Through funding provided by EPA's Office of Research and Development (Safe Buildings Program), a collaborative research plan has been established to address several key issues. Research is currently being conducted on 2 fronts: (1) the evaluation of quantitative methodology for assessing the efficacy of sporicides, and (2) the development and comparative testing of selected modifications to improve the AOAC Sporicidal Activity Test (AOAC Method 966.04). Future studies will include the evaluation of candidate surrogates of B. anthracis using a quantitative method, and a multilaboratory validation study of a quantitative method-surrogate combination. The General Referee is serving as the Principal Investigator for all research described in this report, and has the overall responsibility for the technical conduct of the projects. In cases where the General Referee has oversight of projects that involve official collaborative studies and validation support from AOAC INTERNATIONAL, AOAC officials and the Committee Chair will determine the appropriate mechanism for formal study review. The 2003 General Referee report provides the background on the development and direction of the research projects. The preliminary data, general conclusions, next steps, and recommendations are provided in this report.  相似文献   