首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
A cold on-column injection system for capillary gas chromatography (GC) applications was constructed. It was based upon a conventional split/splitless capillary GC inlet, which in turn was a modification of a conventional packed GC column inlet. The heart of the laboratory constructed cold on-column inlet design was a disposable pyrex micro-sampling pipet, which functioned as a needle guide for sample injection. The sample was injected through a traditional GC septum. Construction of the injection system is described and applications are illustrated by separations of a variety of complex mixtures.  相似文献   

2.
The performance of split and splitless programmed-temperature (PTV) injection is compared to cold on-column and hot (classical) split injection for the analysis of triglycerides on an apolar capillary gas chromatographic column. Quantitative accuracy and precision of PTV injection are determined for a synthetic mixture of triglycerides relative to cold on-column injection.  相似文献   

3.
A rapid and inexpensive gas-diffusion (GD) flow injection method for the on-line determination of Hg(II) in aqueous samples is described. The analytical procedure involves the injection of a Hg(II) sample into a 1.5 M H2SO4 carrier stream which is merged with a reagent stream containing 0.6% SnCl2 and 1.5 M H2SO4. Under these conditions Hg(II) is reduced to metallic mercury which partially evaporates through a Teflon membrane into an acceptor stream containing 1.75×10−4 M KMnO4 in 0.3 M H2SO4. The decrease in the absorbance of the acceptor stream at 528 nm corresponding to the absorption maximum of the permanganate anion can be related to the original concentration of Hg(II) in the sample. The method is characterized by a detection limit of 4 μg l−1 and a sampling frequency of 8 h−1. The flow system was successfully applied to the analysis of river samples spiked with Hg(II).  相似文献   

4.
In a previous paper we described the possibilities of cold on-column – sample split injection achieved by means of an inexpensive and simple three way press-fit device [1]. The same arrangement is proposed here for cold on-column – solvent split injection in which specific elimination of the solvent, without loss of any other sample components, is achieved by opening the splitting tube (or better, in this case, the early solvent vapor exit) during solvent elution, and then closing it during elution of the sample's other components. Discrimination between solvent and other sample components is achieved by means of a retention gap, a retaining precolumn, and an early vapor exit. The technique enables both selective enrichment of a sample, in order to record satisfactory mass and infrared spectra of minor components, and injection of large volumes (up to 100 μl) of dilute solutions which cannot be concentrated because of component volatility. Details of the assembly and tuning the system are given, together with some examples.  相似文献   

5.
Summary An integrated procedure is described which allows direct injection quantitative screening to single figure parts per billion (g/L) levels of ethyl carbamate in the natural matrix of distilled alcoholic beverage. Injection and detection performance was studied and optimized to allow this routine, reproducible, trace analysis without any sample pre-treatment. All aspects of the analysis including autosampler run sequences and automated internal standard report generation are initiated and controlled from a single GC/MS workstation.Excerpt from the Ph. D. Thesis (in preparation) of K. MacNamara, Universität Karlsruhe  相似文献   

6.
The programmable temperature vaporizing injector (PTV) has been used to study the effects of injection temperature and initial heating period on the FID response factors of TBDMS derivatives of 17 protein amino acids. The relative response factors were calculated for injection temperatures of 50°C, 90°C, 160°C, 220°C, and 260°C with different initial heating periods (1 s, 5 s, and 10 s) and the results compared with the values obtained for the calculated response factors obtained under classical split injection conditions (300°C, continuous). Except for expected peak broadening effects, the initial heating period does not seem to have significative effects on relative peak areas. The response to the derivatives of alanine, glycine, α-aminobutyric acid, valine, proline, methionine, cysteine, phenylalanine, asparagine, and arginine was only slightly affected by increasing the injection temperature whereas the response factors for the derivatives of serine, threonine, glutamic acid, lysine, histidine, tyrosine, and tryptophan were strongly dependent upon initial injection temperatures, decreasing rapidly at temperatures above 160°C. The cold split-splitless injection is clearly advantageous over the classical hot injection techniques for the analysis of this type of aminoacid derivative.  相似文献   

7.
研究了IRC-718离子交换树脂、122螯合树脂和MuromacA-1树脂对镉的预浓集条件,建立了超痕量镉的流动注射在线吸着分离预浓集冷蒸气发生原子吸收光谱测定方法.在每小时进样60,60和45次速度下检出限(3σ)分别为3.0,3.0和2.4ng/L.线性范围0~0.3μg/L,对0.2μg/L镉测定的相对标准偏差为2.0%~2.6%(n=11).讨论了用这3种离子交换树脂微柱进行分离预浓集时条件参数的优化、抗干扰能力以及对天然水样的回收率,并分别进行了水样的测定.  相似文献   

8.
The capillary gas chromatographic analysis of complex naturally occurring and food-product triglyceride mixtures is accomplished qualitatively and quantitatively on columns coated with methyl and methyl-phenyl (65%) silicones using programmed-temperature split/splitless and on-column injection. Faster analysis times are achieved using elevated initial column oven temperatures with cold initial injector temperatures.  相似文献   

9.
A simple and robust time-based on-line sequential injection system for trace mercury determination via cold vapour atomic absorption spectrometry (CVAAS), employing a new integrated gas-liquid separator (GLS), which in parallel operates as reactor, was developed. Sample and reductant are sequentially loaded into the GLS while an argon flow delivers the released mercury vapour through the atomic absorption cell. The proposed method is characterized by the ability of successfully managing variable sample volume up to 30 ml in order to achieve high sensitivity. For 20 ml sample volume, the sampling frequency is 25 h−1. The calibration curve is linear over the concentration range 0.05-5.0 μg l−1 of Hg(II), the detection limit is cL = 0.02 μg l−1, and the relative standard deviation is sr = 2.6% at 1.0 μg l−1 Hg(II) level. The performance of the proposed method was evaluated by analyzing certified reference material and applied to the analysis of natural waters and biological samples.  相似文献   

10.
A simple and quick gas chromatographic method has been developed for the determination of up to six commonly used antiepileptic drugs in human serum. The antiepileptics are isolated from serum by solid phase extraction on to a reversed phase sorbent and recovered with ethyl acetate as eluent. The ethyl acetate eluate is suitable for direct on-column injection on to a phenyl methyl siloxane capillary column; hydrogen is used as carrier gas and the compounds are separated with a two-ramp temperature program. Detection is by FID. The reproducibility of the method varies between 2 and 6% RSD, depending on the drug and the level analyzed; limits of detection were found to be 14–51 pg and minimum assayed concentrations in serum were between 14 and 51 ng/ml.  相似文献   

11.
The characteristics of bias caused by split-flow electrokinetic injection (SEKI), a new type of sample injection method used in coupled flow injection-capillary electrophoresis system (FI-CE), was investigated using pseudoephedrine hydrochloride, a basic drug, and ibuprofen, an acidic drug, as model analytes. It was found that bias imposed by SEKI under the condition of continuous sample matrix/running buffer was similar to that done by electrokinetic injection (EKI). The linearity of calibration curve provided by SEKI was similar to that offered by non-bias hydrodynamic injection (HDI) but significantly better than that obtained by EKI. These features were exploited to improve analytical performances in simultaneous determination of the minor ingredient of pseudoephedrine hydrochloride and the major ingredient of ibuprofen in a pharmaceutical preparation. Detectability of 0.7 mg/l for pseudoephedrine hydrochloride was achieved at a sample throughput rate of 24 times per hour, which is 30% lower than that obtained by HDI-based conventional CE. Relative standard deviations (RSDs) of 2.8% for the minor ingredient and 1.2% for the major ingredient were produced in 11 runs of a test solution containing 13.1 mg/l pseudoephedrine hydrochloride and 81.4 mg/l ibuprofen. This is an improvement compared to that obtained by HDI-based conventional CE. Analytical results for two batches of compound ibuprofen tablets by the SEKI-based FI-CE approach were in good agreement with that obtained by a conventional high performance liquid chromatographic method. __________ Translated from Chinese Journal of Chromatography, 2005, 23(2) (in Chinese)  相似文献   

12.
An automatic sequential injection system, combining monosegmented flow analysis, sequential injection analysis and sequential injection titration is proposed for acidity determination. The system enables controllable sample dilution and generation of standards of required concentration in a monosegmented sequential injection manner, sequential injection titration of the prepared solutions, data collecting, and handling. It has been tested on spectrophotometric determination of acetic, citric and phosphoric acids with sodium hydroxide used as a titrant and phenolphthalein or thymolphthalein (in the case of phosphoric acid determination) as indicators. Accuracy better than |4.4|% (RE) and repeatability better than 2.9% (RSD) have been obtained. It has been applied to the determination of total acidity in vinegars and various soft drinks. The system provides low sample (less than 0.3 mL) consumption. On average, analysis of a sample takes several minutes.  相似文献   

13.
A sequential injection analysis (SIA) system based on polydimethylsiloxane (PDMS) chip with integrated pneumatic-actuated valves was developed. A novel SIA operation mode using multiphase laminar flow effect and pneumatic microvalve control was proposed. The sample and reagent solutions were synchronously loaded and injected in the chip-based sample injection module instead of multi-step sequential injection by a multiposition valve and a reciprocating pump as in conventional SIA system. The sample and reagent injection volumes were reduced to ca. 1.1 nL. The present system has the advantages of simple structure, fast and convenient operation, low sample and reagent consumption, and high degree of integration and automation. The system operation conditions were optimized using fluorescein as model sample. Its feasibility in biological analysis was preliminarily demonstrated in enzyme inhibition assay.  相似文献   

14.
选用弱极性通用毛细管色谱柱(5%苯基,95%甲基聚硅氧烷)、冷柱头进样及氢火焰离子化检测器(FID),采用程序升温,以甲基异丁酮为内标物,建立了测定二碳酸二甲酯(DMDC)纯度的气相色谱法。在优化的条件下,方法相关系数r=0.9996,检测限为0.5 mg/kg,线性范围为1.0~100 mg/kg,对实际样品进行测定,加标回收率为90.2%~98.7%,相对标准偏差为2.9%~5.2%。方法适用于食品添加剂二碳酸二甲酯的纯度分析。  相似文献   

15.
《Analytical letters》2012,45(13-14):1387-1406
Abstract

A potentiometric flow injection analysis system is described, enabling tap water and other fluoride-bearing matrices of low interferent level to be determined at the rate of 360 samples per hour using an electrode polished with slurried alumina. Important parameters, such as carrier stream composition, sample volume and detector cell design are discussed with respect to this system, Fluoride electrodes regenerated with silver fluoride and silver epoxy are evaluated in flow injection mode, both before and after polishing.  相似文献   

16.
A gas-diffusion flow injection method for the chemiluminescence detection of Hg(II) based on the luminol-H2O2 reaction was developed. The analytical procedure involved the injection of Hg(II) samples and standards into a 1.50 M H2SO4 carrier stream, which was subsequently merged with a reagent stream of 0.60% (w/v) SnCl2 in 1.50 M H2SO4 to reduce Hg(II) to metallic Hg. The gas-diffusion cell was thermostated at 85 °C to enhance the vaporisation of metallic Hg. Mercury vapour, transported across the Teflon membrane of the gas-diffusion cell into the acceptor stream containing 1.00 × 10−4 M KMnO4 in 0.30 M H2SO4, was oxidised back to Hg(II). The acceptor stream was merged with a reagent stream containing 2.50 M H2O2 in deionised water and then the combined stream was merged with another reagent stream containing 7.50 × 10−3 M luminol in 3.00 M NaOH at a confluence point opposite to the photomultiplier tube of the detection system. The chemiluminescence intensity of the luminol-H2O2 reaction was enhanced by the presence of Hg(II) in the acceptor stream. The corresponding increase was related to the original concentration of Hg(II) in the samples and standards. Under optimal conditions, the chemiluminescence gas-diffusion flow injection method was characterised by a linear calibration range between 1 μg L−1 and 100 μg L−1, a detection limit of 0.8 μg L−1 and a sampling rate of 12 samples per hour. It was successfully applied to the determination of mercury in seawater and river samples.  相似文献   

17.
Tsai CH  Yang RJ  Tai CH  Fu LM 《Electrophoresis》2005,26(3):674-686
The effective design and control of a capillary electrophoresis (CE) microchip requires a thorough understanding of the electrokinetic transport phenomena associated with its microfluidic injection system. The present study utilizes a numerical simulation approach to investigate these electrokinetic transport processes and to study the control parameters of the injection process. Injection systems with a variety of different configurations are designed and tested, including the cross-form, T-form, double-T-form, variable-volume focused flow cross-form, and variable-volume triple-T-form configuration. Each injection system cycles through a predetermined series of steps in which the magnitudes and distributions of the applied electric field are precisely manipulated in order to effectuate a virtual valve. This study investigates the sample leakage effect associated with each of the injection configurations and applies the double-L, pullback, and focusing injection techniques to minimize the sample leakage effect. The injection methods presented in this paper have the exciting potential for use in high-quality, high-throughput chemical analysis applications and throughout the micro-total-analysis systems field.  相似文献   

18.
罗金文  朱海霖  李会林 《色谱》2005,23(2):189-192
以碱性药物盐酸伪麻黄碱和酸性药物布洛芬为对象研究了分流式电动进样(一种用于流动注射-毛细管电泳(FI-CE)联用系统的新进样方法)歧视效应的特性。结果发现:在样品介质与运行缓冲液一致的条件下,FI-CE分流式电动进样产生的歧视效应与电动进样相似,但获得的校正曲线的线性明显优于电动进样,而与没有歧视效应的压力进样所获得的线性相似。利用这些特征提高了同时测定复方布洛芬片中少量组分盐酸伪麻黄碱和主要组分布洛芬的分析性能。在24次/h的采样频率下,盐酸伪麻黄碱的检测限为0.7 mg/L,比采用压力进样的毛细管电泳法所得的检测限低30%。连续进样11次分析含有13.1 mg/L盐酸伪麻黄碱和81.4 mg/L布洛芬的试样溶液,峰面积的相对标准偏差分别为2.8%(盐酸伪麻黄碱)和1.2%(布洛芬),明显优于采用压力进样的毛细管电泳法。用该法测定了两批复方布洛芬片中两种组分的含量,所得结果与高效液相色谱法的测定结果一致。  相似文献   

19.
A sequential injection‐bead injection‐lab‐on‐valve system was hyphenated to HPLC for online renewable micro‐solid‐phase extraction of carbamate insecticides. The carbamates studied were isoprocarb, methomyl, carbaryl, carbofuran, methiocarb, promecarb, and propoxur. LiChroprep® RP‐18 beads (25–40 μm) were employed as renewable sorbent packing in a microcolumn situated inside the LOV platform mounted above the multiposition valve of the sequential injection system. The analytes sorbed by the microcolumn were eluted using 80% acetonitrile in 0.1% acetic acid before online introduction to the HPLC system. Separation was performed on an Atlantis C‐18 column (4.6×150 mm, 5 μm) utilizing gradient elution with a flow rate of 1.0 mL/min and a detection wavelength at 270 nm. The sequential injection system offers the means of performing automated handling of sample preconcentration and matrix removal. The enrichment factors ranged between 20 and 125, leading to limits of detection (LODs) in the range of 1–20 μg/L. Good reproducibility was obtained with relative standard deviations of <0.7 and 5.4% for retention time and peak area, respectively. The developed method has been successfully applied to the determination of carbamate residues in fruit, vegetable, and water samples.  相似文献   

20.
Hole injection into aqueous electrolyte solution is proposed to occur when oxide-coated aluminum electrode is anodically pulse-polarized by a voltage pulse train containing sufficiently high-voltage anodic pulses. The effects of anodic pulses are studied by using an aromatic Tb(III) chelate as a probe known to produce intensive hot electron-induced electrochemiluminescence (HECL) with plain cathodic pulses and preoxidized electrodes. The presently studied system allows injection of hot electrons and holes successively into aqueous electrolyte solutions and can be utilized in detecting electrochemiluminescent labels in fully aqueous solutions, and actually, the system is suggested to be quite close to a pulse radiolysis system providing hydrated electrons and hydroxyl radicals as the primary radicals in aqueous solution without the problems and hazards of ionizing radiation. The analytical power of the present excitation waveforms are that they allow detection of electrochemiluminescent labels at very low detection limits in bioaffinity assays such as in immunoassays or DNA probe assays. The two important properties of the present waveforms are: (i) they provide in situ oxidation of the electrode surface resulting in the desired oxide film thickness and (ii) they can provide one-electron oxidants for the system by hole injection either via F- and F+-center band of the oxide or by direct hole injection to valence band of water at highly anodic pulse amplitudes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号