首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
A novel, sensitive and selective adsorptive stripping procedure for simultaneous determination of iron, copper and cadmium is presented. The method is based on the adsorptive accumulation of thymolphthalexone (TPN) complexes of these elements onto a hanging mercury drop electrode, followed by reduction of adsorbed species by voltammetric scan using differential pulse modulation. The influences of control variables on the sensitivity of the proposed method for the simultaneous determination of iron, copper and cadmium were studied using the Derringer desirability function. The optimum analytical conditions were found to be TPN concentration of 2.0 μM, pH of 9.5, and accumulation potential at ?0.4 V vs. Ag/AgCl with an accumulation time of 60 s. The peak currents are proportional to the concentration of iron, copper and cadmium over the 1–80, 0.5–100 and 1–100 ng mL?1 ranges with detection limits of 0.5, 0.4 and 0.9 ng mL?1, respectively. The R.S.D. at a concentration level of 20 ng mL?1 of iron, copper and cadmium were 2.5%, 0.9% and 1.5% (n=6), respectively. The procedure was applied to the simultaneous determination of iron, copper and cadmium in the tap water and some synthetic samples with satisfactory results.  相似文献   

2.
A sensitive and selective method for the simultaneous determination of copper and bismuth by adsorptive stripping was developed using nuclear fast red (2-anthracenesulfonic acid, 4-amino-9,10-dihydro-1,3-dihydroxy-9,10-dioxo-, monosodium salt) as selective complexing agent onto hanging mercury drop electrode. In a single scan both metals gave peaks that were distinctly separated by 85 mV allowing their determination in the presence of each other. Optimal analytical conditions were found to be: nuclear fast red concentration of 80 μM, pH of 2.8 and adsorptive potential of −300 mV versus Ag/AgCl. With accumulation time of 180 s the peaks currents are proportional to concentration of copper and bismuth over the 1-100 and 5-60 ng mL−1 range with detection limits of 0.2 and 1.2 ng mL−1, respectively. The procedure was applied to simultaneous determination of copper and bismuth in some real samples.  相似文献   

3.
A selective and sensitive method for simultaneous determination of lead, zinc and copper by adsorptive differential pulse cathodic stripping voltammetry is presented. The method is based on adsorptive accumulation of the complexes of Pb(II), Zn(II), and Cu(II) ions with dopamine onto hanging mercury drop electrode (HMDE), followed by reduction of adsorbed species by differential pulse cathodic stripping voltammetry. The effect of experimental parameters such as pH, dopamine concentration, accumulation time and potential and scan rate were examined. Under the optimized conditions, linear calibration curves were established for the concentration of Pb, Zn, and Cu in the ranges of 5–150, 5–250, and 1–150 ng/mL, respectively. Detection limits of 0.06, 0.25, and 0.04 ng/mL for Pb, Zn, and Cu were obtained. An application of the proposed method is reported for the determination of these elements in some real samples such as natural waters and alloys.  相似文献   

4.
A sensitive and selective procedure is presented for the voltammetric determination of copper(II) ion. The procedure involves an adsorptive accumulation of Cu2+-PPKO on a hanging mercury drop electrode, followed by a stripping voltammetric measurement of reduction current of adsorbed complex at about -0.30 V (vs. SCE). The optimum conditions for the analysis of copper(II) ion include pH (5.8-7.0), 60 microgM PPKO and an accumulation potential of -0.5 V (vs. SCE). The peak current is proportional to the concentration of copper over the range 0.3-76 ng mL(-1) with a detection limit of 0.01ng mL(-1) with an accumulation time of 60 s. The speciation of different forms of complex between copper(II) ion and PPKO, using the Best (Martell program), followed pH measurement were examined. The method was applied to the determination of copper(II) ion content in real samples successfully.  相似文献   

5.
A sensitive and selective method for the simultaneous determination of copper, zinc and lead is presented. The method is based on the adsorptive accumulation of 2′,3,4′,5,7-pentahydroxyflavone (Morin) complexes of these elements onto a hanging mercury drop electrode, followed by reduction of adsorbed species by voltammetric scan using differential pulse modulation. Optimal analytical conditions were found to be Morin concentration of 2.0 μM, pH of 4.0, and an adsorption potential at −500 mV versus Ag/AgCl. With an accumulation time of 60 s, the peak currents are proportional to the concentration of copper, lead and zinc over the 1 to 60, 0.3-80 and 1-70 ng ml−1 range with detection limits of 0.06, 0.08 and 0.06 ng ml−1, respectively. The procedure was applied to the simultaneous determination of copper, lead and zinc in some real and synthetic artificial real samples with satisfactory results.  相似文献   

6.
A sensitive and fast method for the simultaneous determination of trace amounts of nickel and cadmium in real samples has been described using differential pulse adsorptive stripping voltammetry (DPASV) by adsorptive accumulation of the N,N′‐bis(salicylaldehydo)4‐carboxyphenylenediamine (BSCPDA)–complex on the hanging mercury drop electrode (HMDE). As supporting electrolyte 0.02 mol L?1 ammonia buffers containing ligand has been used. Optimal analytical conditions were found to be: BSCPDA concentration of 42 μM, pH 9.6 and adsorption potential at ?50 mV versus Ag/AgCl. With an accumulation time of 20 s, the peaks current are proportional to the concentration of nickel and cadmium over the 1–180, and 0.5–200 ng mL?1 with detection limits of 0.06 and 0.03 ng mL?1 respectively. The sensitivity of method for determination of nickel and cadmium were obtained 0.54 and 0.98 nA mL ng?1, respectively. The procedure was applied to simultaneous determination of nickel and cadmium in some real and synthetic artificial samples with satisfactory results.  相似文献   

7.
A differential pulse polarographic method is proposed for the trace determination of bismuth and copper from large volumes of aqueous samples after adsorption of their 1-(2-thiazolylazo)-2-naphthol complexes onto microcrystalline naphthalene in the pH ranges of 7.2-9.0 and 4.0-7.8, respectively. Bismuth and copper are desorbed from microcrystalline naphthalene with 9 mL 1M HCl. Well-defined peaks are obtained at Ep = -0.09 and -0.20 V versus a saturated calomel electrode, in an HCl-isoquinoline medium as the supporting electrolyte, for bismuth and copper, respectively. Bismuth is reduced reversibly with a 3-electron change, whereas copper is reduced irreversibly under these conditions. The detection limits are 55 ng/mL for bismuth and 91 ng/mL for copper. Linearity is maintained in the concentration ranges of 0.18-13.5 and 0.30-17.3 microg/mL for bismuth and copper, respectively, with corresponding correlation coefficients of 0.9996 and 0.9885. The relative standard deviations are 1.0% for bismuth at 2.0 microg/mL and 1.4% for copper at 5.0 microg/mL. Various parameters were optimized to develop conditions for the determination of these metal ions in various samples.  相似文献   

8.
《Analytical letters》2012,45(3):465-478
ABSTRACT

A technique is presented for the determination of trace amounts of copper(II) by adsorptive cathodic stripping voltammetry. The procedure is based on adsorptive accumulation of copper(II)-Alizarin Red S (ARS) complex on a hanging mercury drop electrode, followed by a stripping voltammetric measurement of the reduction current of the adsorbed complex at -0.16 V (vs. Ag/AgCl). The height of the copper -ARS reduction peak is linearly dependent upon the copper(II) concentration between 0.2-15 and 15-500 ng.ml?1. The detection limit of the technique is 0.05 ng.ml?1 copper(II) for a collection time of 1 minute. The method is free from most interferences. The procedure has been successfully applied to the determination of trace amounts of copper(II) in some analytical grade salts.  相似文献   

9.
A new method is presented for the determination of bismuth and copper based on cathodic adsorptive stripping of complexes of Cu(II) and Bi(III) with 2′,3,4′,5,7-pentahydroxyflavone (morin) at a hanging mercury drop electrode (HMDE). The effect of various parameters such as pH, concentration of morin, accumulation potential and accumulation time on the selectivity and sensitivity were studied. The optimum conditions for determination of copper include nitric acid concentration 0.1 M, morin concentration 0.6 μM and accumulation potential of −300 mV. Those conditions for the determination of bismuth include 0.15 M acid concentration, 0.6 μM morin and accumulation potential of −300 mV. Under these optimum conditions and for an accumulation time of 60 s, the measured peak current at −20 to 25 mV is proportional to the concentration of copper and bismuth over the range of 0.2-130 and 5-50 ng ml−1, respectively. At high concentration of morin (35 μM morin) and accumulation potential of −300 mV (versus Ag/AgCl reference electrode) the peak current is proportional only to the concentration of copper and bismuth has no contribution to the current. At low concentration of morin (0.5 μM morin) and accumulation potential of 100 mV (versus Ag/AgCl reference electrode) the peak current is proportional only to the concentration of bismuth. The method was applied to the determination of copper and bismuth in some real and synthetic samples with satisfactory results.  相似文献   

10.
《Electroanalysis》2005,17(17):1589-1594
Simultaneous determination of bismuth and copper by anodic stripping voltammetry using H‐point standard addition method (HPSAM) with simultaneous addition of analytes is described. The effect of various parameters including acid concentration, accumulation time, accumulation potential and concentration ratio of analytes in the standard solution on the sensitivity and accuracy of method were investigated. The results of applying the H‐point standard addition method showed that Cu2+ and Bi3+ could be determined simultaneously with the concentration ratios of Cu2+ to Bi3+ varying from 1 : 15 to 16 : 1 in the mixed sample. The method was successfully applied to the simultaneous determination of copper and bismuth in some synthetic mixtures.  相似文献   

11.
基于原子荧光光谱法测定铋元素时检出限低、测定结果稳定且准确等优点,研究原子荧光光谱法测定铜合金中铋元素含量的方法。在标准系列中加入相近浓度的铜元素标准溶液,原子荧光光谱法测定铜合金中铋元素含量。称取0.1 g样品,加入10 mL硝酸溶解,10%硫脲-5%抗坏血酸溶液7.5 mL预处理样品。在20μg/L的铋标准溶液中加入6 mL浓度为1000μg/mL的铜元素标准溶液。结果表明:在0~20μg/L范围内,该方法线性关系良好,线性方程为I=138.1670c+43.8572,相关系数为0.9996,所测定的样品中铋元素含量的相对误差在-4.3%~7.7%之间,精密度在0.4%~4.7%之间。原子荧光光谱法可作为铜合金中铋元素含量测定的方法。  相似文献   

12.
A highly sensitive procedure is presented for the determination of ultra-trace concentration of tungsten by catalytic adsorptive stripping voltammetry. The method is based on adsorptive accumulation of the tungsten-pyrocatechol violet complex onto a hanging mercury drop electrode, followed by reduction of the adsorbed species by voltammetric scan using differential pulse modulation. The reduction current is enhanced catalytically by chlorate. The influence of variables was completely studied by factorial design analysis. Optimum analytical conditions for the determination of tungsten were established. Tungsten can be determined in the range 0.06–12.0 ng/mL with a limit of detection of 0.02 ng/mL. The influence of potentially interfering ions on the determination of tungsten was studied. The procedure was applied to the determination of tungsten in one sandwich polyoxometalate and some synthetic samples similar to alloy compounds with satisfactory results.  相似文献   

13.
硒碳糊电极微分电位溶出法测定铜和铋   总被引:1,自引:0,他引:1  
建立了掺杂硒碳糊电极同时测定铜和铋的微分电位溶出法。在HCl(0.05mol/L)中,在-0.3V(vs.Ag/AgCl)下,Cu2+和Bi3+电沉积在电极表面,再在溶液中溶解氧的作用下,铜和铋从电极表面溶出,分别于0.30V和0.02V获得灵敏的电位溶出峰。微分电位溶出峰高(dt/dE)与铜和铋的浓度成线性关系,线性范围为5.0×10-9~1.55×10-7mol/L,检出限分别为4.0×10-9和2.5×10-9mol/L(S/N=3)。方法用于实际样品中铜和铋的测定,结果令人满意。  相似文献   

14.
An adsorptive differential pulse stripping method for the simultaneous determination of lead and tin is proposed. The procedure involves an adsorptive accumulation of lead and tin on a hanging mercury drop electrode (HMDE), followed by oxidation of adsorbed lead and tin by voltammetric scan using differential pulse modulation. The optimum experimental conditions are: 0.2 mol L?1 HNO3, accumulation potential of ?900 mV versus Ag/AgCl, accumulation time of 200 s, scan rate of 20 mV s?1 and pulse height of 80 mV. Lead and tin peak currents were observed in the same potential region at about ?400 mV. The simultaneous determination of lead and tin by using voltammetry is a difficult problem in analytical chemistry, due to voltammogram interferences. The resolution of a mixture of lead and tin by the application of orthogonal signal correction‐partial least squares (OSC‐PLS) was performed. The linear dynamic ranges were 0.003‐0.35 and 0.008‐0.50 μg mL?1 and detection limits were land 3 ng mL?1 for lead and tin, respectively. The RMSEP for lead and tin with OSC and without OSC were 2.8737, 6.0557 and 8.0941, 9.5151, respectively. The capability of the method for the analysis of real samples was evaluated by the determination of lead and tin in water samples with satisfactory results.  相似文献   

15.
A very sensitive electrochemical stripping procedure for azinphos-methyl (Guthion) is reported. Accumulation is achieved by adsorption of the compound on a hanging mercury drop electrode. The adsorptive stripping response was evaluated with respect to accumulation time and potential, concentration dependence, electrolyte and other variables. The determination limit is 0.2 ng ml?1 after 300 s accumulation and 0.4 ng ml?1 after 180 s accumulation. The procedure was applied to spiked river water.  相似文献   

16.
A selective and sensitive stripping voltammetric method for the determination of trace amounts of copper(II) with a recently synthesized naphthol-derivative Schiff's base (2,2'-[1,2-ethanediylbis(nitriloethylidyne)]bis(1-naphthalene)) is presented. The method is based on adsorptive accumulation of the resulting copper-Schiff's base complex on a hanging mercury drop electrode, followed by the stripping voltammetric measurement at the reduction current of adsorbed complex at -0.15 V (vs. Ag/AgCl). The optimal conditions for the stripping analysis of copper include pH 5.5 to 6.5, 8 microM Schiff's base and an accumulation potential of -0.05 V (vs. Ag/AgCI). The peak current is linearly proportional to the copper concentration over a range 2.3-50.8 ng ml(-1) with a limit of detection of 1.9 ng ml(-1). The accumulation time and RSD are 90 s and (3.2-3.5)%, respectively. The method was applied to the determination of copper in some analytical grade salts, tap water, human serum and sheep's liver.  相似文献   

17.
This work assesses the use of modified natural natrolite zeolite as an adsorptive material for the separation and preconcentration of trace amounts of ions. In this work we investigated the potential of modified natural natrolite zeolite for the simultaneous separation and preconcentration of trace amounts of copper and zinc ions. We have developed a simple, rapid, selective, sensitive and economical method for the simultaneous separation and preconcentration of trace amounts of copper and zinc in an aqueous medium using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) as an analytical reagent. The sorption was quantitative in the pH range 7.5 - 9.5, whereas quantitative desorption occurred instantaneously with 5.0 mL of 2 mol L(-1) nitric acid. Linearity was maintained between 0.05 - 6.0 microg mL(-1) for copper and 0.02 - 1.5 microg mL(-1) for zinc in the final solution. Ten replicate determinations of 1.0 microg mL(-1) copper and 0.5 microg mL(-1) zinc in a mixture gave mean absorbances of 0.1687 and 0.2788 with relative standard deviations of +/-1.2% and +/-1.3%, respectively. The detection limits were 0.03 ng mL(-1) for Cu(II) and 0.006 ng mL(-1) for Zn(II) in the original solution (3 sigma(bl)/m). Different parameters, such as the effect of the pH, flow rate, breakthrough volume and interference of a large number of anions and cations, were studied and the proposed method was used for the determination of these metal ions in water as well as standard samples (e.g. Nippon Keikinzoku Kogyo (NKK) CRM, No. 916 and No. 920 aluminum alloy, National Institute for Environment Studies (NIES) No. 1 pepperbush and NIES No. 2 pond sediment). The determination of these metal ions in standard samples showed that the proposed method has good accuracy (recovery > 97%).  相似文献   

18.
Trace amounts of thallium(I) can be determined using adsorptive cathodic stripping voltammetry in the presence of Xylenol Orange (XO). The reduction current of the thallium(I)-XO complex ion was measured by square-wave cathodic stripping voltammetry. The peak potential was at -0.44 V vs. Ag/AgCl. The effect of various parameters (pH, ligand concentration, accumulation potential and collection time) on the response are discussed. The response was linearly related to the thallium concentration in the range 0.5-110 ng ml(-1) and 110-2000 ng ml(-1). The limit of detection was 0.2 ng ml(-1). The relative standard deviation for the determination of 80 ng ml(-1) thallium was 2.8%. Many common anions and cations did not interfere with the determination of thallium. The interference of lead was reduced by the addition of 0.003 M sodium carbonate. The voltammetric procedure was then successfully applied to the determination of thallium in various complex samples.  相似文献   

19.
An adsorptive differential pulse stripping method is proposed for the simultaneous determination of molybdenum and tungsten based on the formation of their complexes with a novel proton transfer compound, [phenH]+[pyzdc]?, containing both pyrazine-2,3-dicarboxylic acid and 1,10-phenanthroline. The optimum experimental conditions were obtained using 0.052 mM [phenH]+[pyzdc]? ligand, pH 3.3, accumulation potential of ?0.1 V versus Ag/AgCl, accumulation time of 60 s and scan rate of 33.3 mV/s. An adaptive neuro-fuzzy inference system (ANFIS) was utilized for the analysis of the voltammogram data. The detection limits were 4.0 ng/mL for Mo(VI) and 3.0 ng/mL for W(VI). The influence of potential interfering ions on the determination of molybdenum and tungsten was studied. The procedure was applied to the simultaneous determination of molybdenum and tungsten in some water samples.  相似文献   

20.
A novel, sensitive and selective adsorptive stripping procedure for determination of aluminum is presented. The method is based on the adsorptive accumulation of dithiooxamide (Rubeanic acid) complex of aluminum onto a hanging mercury drop electrode, followed by reduction of adsorbed species by voltammetric scan using differential pulse modulation. The influences of control variables on the sensitivity of the proposed method for the determination of aluminum were studied. The optimum analytical conditions were found to be Rubeanic acid (RA) concentration of 8.0×10?5 M, ammonia buffer (NH3? NH4Cl) pH of 6.5, and accumulation potential at ?50 mV vs. Ag/AgCl with an accumulation time of 60 s. The peak currents are proportional to the concentration of aluminum over the 0.3–70 ng mL?1 ranges with detection limit of 0.012 ng mL?1. The procedure was applied to the determination of aluminum in the Lab. Water, HCl of Merck and potato samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号