首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new simple and rapid dispersive liquid–liquid microextraction method has been developed for the extraction and analysis of organochlorine pesticides (OCPs) in water samples. The method is based on the solidification of a floating organic drop (DLLME-SFO) and is combined with gas chromatography/electron capture detection (GC/ECD). Very little solvent is required in this method. The disperser solvent (200 μL acetonitrile) containing 10 μL hexadecane (HEX) is rapidly injected by a syringe into the 5.0 mL water sample. After centrifugation, the fine HEX droplets (6 ± 0.5 μL) float at the top of the screw-cap test tube. The test tube is then cooled in an ice bath. After 5 min, the HEX solvent solidifies and is then transferred into a conical vial, where it melts quickly at room temperature, and 1 μL of it is injected into a gas chromatograph for analysis. Under optimum conditions, the enrichment factors and extraction recoveries are high and range between 37–872 and 82.9–102.5%, respectively. The linear range is wide (0.025–20 μg L−1), and the limits of detection are between 0.011 and 0.11 μg L−1 for most of the analytes. The relative standard deviation (RSD) for 1 μg L−1 of OCPs in water was in the range of 5.8–8.8%. The performance of the method was gauged by analyzing samples of lake and tap water.  相似文献   

2.
A novel method of determining organochlorine pesticides (OCPs) is described. It is based on solid-phase microextraction (SPME) and gas chromatography–electron capture detection. During the development of the method, soil samples were prepared, spiked with standard solution, and then aged for some time. Extraction conditions such as the extraction time, the NaCl content, the volume of water, the extraction temperature and the desorption time were investigated and optimized. The limits of detection obtained using the method ranged from 0.10 to 0.51 ng g−1, and relative standard deviations were lower than 10% for most organochlorine pesticides. Real soil samples were successfully analyzed using the proposed method. The results from the method developed here were in good agreement with those obtained using ultrasonic extraction. The result demonstrates that aging soils spiked with standard solution is an important method development step, because the soil samples obtained using this approach are more like real soils than those obtained when aging is not used.   相似文献   

3.
A novel method using sample preparation method, "ultrasound-assisted emulsification microextraction" (USAEME) with manual shaking, coupled with gas chromatography using and an electron capture detector (GC-ECD) was developed for the analysis of organochlorine pesticides (OCPs) in aqueous samples. The apparatus is simple and easy to operate. After manual shaking for 10s, ultrasound was used to accelerate emulsification of the organic solvent (1-decanol) in aqueous solution. Only 10 μL of the low-toxicity extraction solvent is used in this method; no dispersive solvent is required and the total extraction time is ~4 min. Manual shaking before ultrasound-assisted emulsification enhances the extraction efficiency by >100%. The effects of horizontal and vertical orientation as well as the location of the sample within the ultrasonic bath were studied. After centrifugation, we used an improved solvent collection system (ISCS) to reduce the amount of extraction solvent required. A 1 μL sample of the extract was injected into the GC column. Under optimum conditions, the linear range of the method is 5-2500 ngL(-1) for most of the OCPs, and the limit of detection of the method ranged from 0.6 to 2.9 ngL(-1).The relative recoveries ranged from 75 to 107% for sea water and from 70 to 99% for field fresh water. The method, which provides good enrichment factors, low LODs and minimization of the consumption of organic solvent, provides a rapid, simple and environment-friendly procedure for determining OCPs in aqueous samples.  相似文献   

4.
SPE joined with dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME‐SFO) as a novel technique combined with GC with electron‐capture detection has been developed as a preconcentration technique for the determination of organochlorine pesticides (OCPs) in water samples. Aqueous samples were loaded onto multiwalled carbon nanotubes as sorbent. After the elution of the desired compounds from the sorbent by using acetone, the DLLME‐SFO technique was performed on the obtained solution. Variables affecting the performance of both steps such as sample solution flow rate, breakthrough volume, type and volume of the elution, type and volume of extraction solvent and salt addition were studied and optimized. The new method provided an ultra enrichment factor (8280–28221) for nine OCPs. The calibration curves were linear in the range of 0.5–1000 ng/L, and the LODs ranged from 0.1–0.39 ng/L. The RSD, for 0.01 μg/L of OCPs, was in the range of 1.39–13.50% (n = 7). The recoveries of method in water samples were 70–113%.  相似文献   

5.
In the present study, a new and versatile liquid-phase microextraction method is described. This method requires very simple and cheap apparatus and also a small amount of organic solvent. Eight microliters of 1-undecanol was delivered to the surface of solution containing analytes and solution was stirred for a desired time. Then sample vial was cooled by inserting it into an ice bath for 5 min. The solidified 1-undecanol was transferred into a suitable vial and immediately melted; then, 2 μL of it was injected into a gas chromatograph for analysis.Some polycyclic aromatic hydrocarbons (PAHs) were used as model compounds for developing and evaluating of the method performance. Analysis was carried out by gas chromatography/flame ionization detection (GC/FID).Several factors influencing the microextraction efficiency, such as the nature and volume of organic solvent, the temperature and volume of sample solution, stirring rate and extraction time were investigated and optimized. The applicability of the technique was evaluated by determination of trace amounts of PAHs in environmental samples. Under the optimized conditions, the detection limits (LOD) of the method were in the range of 0.07-1.67 μg L−1 and relative standard deviations (R.S.D.) for 10 μg L−1 PAHs were <7%. A good linearity (r2 > 0.995) in a calibration range of 0.25-300.00 μg L−1 was obtained. After 30 min extraction duration, enrichment factors were in the range of 594-1940. Finally, the proposed method was applied to the determination of trace amounts of PAHs in several real water samples, and satisfactory results were resulted. Since very simple devices were used, this new technique is affordable, efficient, and convenient for extraction and determination of low concentrations of PAHs in water samples.  相似文献   

6.
《中国化学快报》2020,31(7):1843-1846
The metal organic framework functionalized with sulfonic acid was combined with magnetic nanoparticles to fabricate a new nanocomposite (denoted as Fe3O4@PDA@Zr-SO3H). By combining with gas chromatography-electron capture detector, the resulting Fe3O4@PDA@Zr-SO3H nanocomposite was successfully used as a high-efficiency adsorbent for pre-concentrating eight organochlorine pesticides from water sample in environment. Apart from the ability of fast separation, the as-prepared Fe3O4@PDA@Zr-SO3H nanocomposite also exhibited high adsorption capacity for organochlorine pesticides. With the use of optimal experimental conditions, the linear relationship can be obtained in the range of 0.05∼300 μg/L, the correlation coefficient was over 0.9978, and the relative standard deviation was located in 2.5%–7.7%. Moreover, the limit of detection and quantification was between 0.005–0.016 μg/L and 0.017∼0.050 μg/L. Finally, the nanocomposite was used for the determination of organochlorine pesticides from environmental water samples, and displayed the recovery of 82%–118%.  相似文献   

7.
A procedure involving the simultaneous performance of liquid–liquid microextraction and polypropylene microporous membrane solid-phase extraction was carried out. The applicability of the proposed procedure was evaluated through extraction of several organochlorine pesticides from river water, tomato and strawberry samples. The parameters affecting the extraction efficiency were optimized by multivariable designs, and the analytical features were estimated. Under optimized conditions, analytes were concentrated onto 1.5 cm long microporous membranes placed directly into the sample containing 15 mL of water with 20 μL of 1-octanol. The best extraction conditions were achieved at 59 °C, with 60 min of extraction time and 2.91 g of sodium chloride. The desorption of the analytes was carried out using 30 μL of a mixture of toluene and hexane in the proportion of 60:40% (v/v) for 10 min. Detection limits in the range of 2.7–20.0 ng L−1, 0.50–1.15 μg kg−1, and 1.53–12.77 μg kg−1 were obtained for river water, strawberry and tomato samples, respectively. Good repeatability was obtained for all three sample types. The results suggest that the proposed procedure represents a very simple and low-cost microextraction alternative rendering adequate limits of quantification for the determination of organochlorine pesticides in environmental and food samples.  相似文献   

8.
We developed a simple and efficient headspace liquid-phase microextraction (LPME) technique named dynamic hook-type liquid-phase microextraction (DHT-LPME) and used it in combination with gas chromatography-mass spectrometry (GC-MS) and an electron capture detector (ECD). Aqueous specimens of organochlorine pesticides (OCPs) were used as model compounds to demonstrate the effectiveness of the technique. In the present study, the calibration curves were linear over at least 2 orders of magnitude with R2 values of 0.997. The method detection limits (MDLs) varied from 2 to 44.0 ng L−1. The precision of DHT-LPME ranged from 6.5 to 14.4%. The relative recoveries of OCPs in rainwater were more than 84.2%. Enrichment factors (EF) in the range 275-1127 were obtained using DHT-LPME.  相似文献   

9.
This paper describes the extraction of 20 organochlorine pesticides (OCPs) from water samples using solid-phase microextraction (SPME). Three fused-silica fibers coated or bonded with polydimethylsiloxane (PDMS) of different film thicknesses (20-, 30-, and 100-μm) were evaluated. The extraction time, the effects of stirring and addition of NaCl to the aqueous sample, the linear range and the precision of this technique, and the effect of carryover were examined for 20 analytes and are presented here. A comparison with results using conventional liquid-liquid extraction demonstrate that the SPME technique is well suited as a fast screening technique for OCPs in water samples.  相似文献   

10.
建立了一种USE-SPME-GC联用测定蔬菜中有机氯和菊酯类农药残留量的新方法,并对分析条件进行优化和探讨,实验表明,萃取液中基体杂质和色素对分析结果干扰较大,我们提出稀释的方法较好的解决这个问题。对实际蔬菜样品进行了测定和分析。  相似文献   

11.
A method to determine 21 organochlorine pesticides in animal feed samples using microwave assisted extraction and solid phase extraction cleanup was optimised regarding its main parameters. After extraction with hexane-acetone (50:50), three different sorbents (alumina/ENVI-Florisil, ENVI-Carb and ENVI-Carb II/PSA) were assayed for the cleanup step. Analytes were eluted with hexane-ethyl acetate (80:20) and determined by gas chromatography and electron capture detection followed by gas chromatography-mass spectrometry. ENVI-Carb and ENVI-Carb II/PSA provided colourless eluates but fewer interferent compounds were found in ENVI-Carb II/PSA chromatograms, so this system was selected to carry out the purification of the extracts. The analytical recoveries obtained with this method were close to 100% in most cases with relative standard deviations lower than 10%. These percentages were similar to those obtained with the Soxhlet extraction procedure, which shows the method suitable for the determination of organochlorine pesticides in animal feed material. The method was also validated with the analysis of a certified reference material (CRM-115 BCR), and the results obtained were in good accordance with the certified values.  相似文献   

12.
烟草中有机氯类农药多残留分析前处理方法对比研究   总被引:1,自引:0,他引:1  
以烟草中有机氯类农药为研究对象,从检出限、回收率、重复性和色谱图4个方面系统比较了机械振荡萃取法、超声波溶剂萃取法、微波辅助萃取法和加速溶剂萃取法4种常用前处理方法。由于加速溶剂萃取法是在高温高压下进行萃取,在提取出残留农药的同时,也提取出更多的干扰物。机械振荡法、超声波溶剂萃取法和微波辅助萃取法各项结果差别较小,其中机械振荡萃取法回收率和重复性最好,但提取时间较长。考虑溶剂消耗和提取时间等方面的因素,微波辅助萃取是较理想的样品前处理方法。  相似文献   

13.
In this study, the organochlorine pesticides (OCPs) levels in lake and tap water samples were determined by a dispersive liquid-liquid microextraction method using a low-density organic solvent and an improved solvent collection system (DLLME-ISCS). This method used a very small volume of a solvent of low toxicity (11 μL of 1-nonanol and 400 μL of methanol) to extract OCPs from 10 mL water samples prior to the analysis by GC. After centrifugation in the dispersive liquid-liquid microextraction, there was a liquid organic drop floating between the water surface and the glass wall of the centrifuge tube. The liquid organic drop (with some water phase) was transferred into a microtube (3 mm×15 mm) with a syringe. The organic and aqueous phases were separated in the microtube immediately. Then, 1 μL of the organic solvent (which was in the upper portion of liquid in the microtube) was easily collected by a syringe and injected into the GC-ECD system for the analysis. Under optimum conditions, the linear range of this method was 5-5000 ng/L for most of the analytes. The correlation coefficient was higher than 0.997. Enrichment factors ranged from 1309 to 3629. The relative recoveries ranged from 73 to 119% for lake water samples. The LODs of the method ranged from 0.7 to 9.4 ng/L. The precision of the method ranged from 1.0 to 10.8% for lake water.  相似文献   

14.
A simple, rapid, efficient, and environmentally friendly pretreatment based on a low‐density solvent based dispersive liquid–liquid microextraction was developed for determining trace levels of 17 organochlorine pesticides in snow. The parameters affecting the extraction efficiency, such as the type and volume of the extraction and dispersive solvents, extraction time, and salt content, were optimized. The optimized conditions yielded a good performance, with enrichment factors ranging from 271 to 474 and recoveries ranging from 71.4 to 114.5% and relative standard deviations between 1.6 and 14.8%. The detection limits, calculated as three times the signal‐to‐noise ratio, ranged from 0.02 to 0.11 μg/L. The validated method was used to successfully analyze 17 analytes in snow water samples, overcoming the drawbacks of some existing low‐density solvent liquid microextraction methods, which require special devices, large volumes of organic solvents, or complicated operation procedures.  相似文献   

15.
Farajzadeh MA  Djozan D  Khorram P 《Talanta》2011,85(2):1135-1142
A novel sample preparation technique, the microextraction method based on a dynamic single drop in a narrow-bore tube, coupled with gas chromatography-flame ionization detection (GC-FID) is presented in this paper. The most important features of this method are simplicity and high enrichment factors. In this method, a microdrop of an extraction solvent assisted by an air bubble was repeatedly passed through a narrow-bore closed end tube containing aqueous sample. It has been successfully used for the analysis of some pesticides as model analytes in aqueous samples. Parameters affecting the method's performance such as selection of extraction solvent type and volume, number of extractions, volume of aqueous sample (tube length), and salt effect were studied and optimized. Under the optimal conditions, the enrichment factors (EFs) for triazole pesticides were in the range of 141-214 and the limits of detection (LODs) were between 2 and 112 μg L−1. The relative standard deviations (C = 1000 μg L−1, n = 6) were obtained in the range of 2.9-4.5%. The recoveries obtained for the spiked well water and grape juice samples were between 71 and 106%. Low cost, relatively short sample preparation time and less solvent consumption are other advantages of the proposed method.  相似文献   

16.
Microwave assisted micellar extraction (MAME) coupled with solid phase microextraction (SPME) and HPLC-UV determination have been used for the determination of five organochlorine pesticides from agricultural soil samples. A non-ionic surfactant, Polyoxyethlylene 10 Lauryl Ether was used, and the different variables for the optimization of MAME and SPME procedures were studied. This method was applied successfully to the determination of these pesticides in several kinds of agricultural soil samples with different characteristics. Most of the compounds studied can be recovered in good yields with R.S.D. lower than 9% and detection limit ranged between 56-96 ng g−1 for the pesticides studied.  相似文献   

17.
Arpa Şahin C  Durukan I 《Talanta》2011,85(1):657-661
In this article, a new ligandless solidified floating organic drop microextraction (LL-SFODME) method has been developed for preconcentration of trace amount of cadmium as a prior step to its determination by flow injection-flame atomic absorption spectrometry (FI-FAAS). The methodology is based on the SFODME of cadmium with 1-dodecanol in the absence of chelating agent. Several factors affecting the microextraction efficiency, such as, pH, sodium dodecylbenzenesulfonate (SDBS) concentration, extraction time, stirring rate and temperature were investigated and optimized. Under optimized experimental conditions an enhancement factor of 205 was obtained for 100 mL of sample solution. The calibration graph was linear in the range of 1.0-25.0 ng mL−1, the limit of detection (3s) was 0.21 ng mL−1 and the limit of quantification (10s) was 0.62 ng mL−1. The relative standard deviation (RSD) for 10 replicate measurements of 10 ng mL−1 cadmium was 4.7%. The developed method was successfully applied to the extraction and determination of cadmium in standard and several water samples and satisfactory results were obtained.  相似文献   

18.
A solid-phase microextraction (SPME) procedure using two commercial fibers coupled with high-performance liquid chromatography (HPLC) is presented for the extraction and determination of organochlorine pesticides in water samples. We have evaluated the extraction efficiency of this kind of compound using two different fibers: 60-μm polydimethylsiloxane–divinylbenzene (PDMS-DVB) and Carbowax/TPR-100 (CW/TPR). Parameters involved in the extraction and desorption procedures (e.g. extraction time, ionic strength, extraction temperature, desorption and soaking time) were studied and optimized to achieve the maximum efficiency. Results indicate that both PDMS-DVB and CW/TPR fibers are suitable for the extraction of this type of compound, and a simple calibration curve method based on simple aqueous standards can be used. All the correlation coefficients were better than 0.9950, and the RSDs ranged from 7% to 13% for 60-μm PDMS-DVB fiber and from 3% to 10% for CW/TPR fiber. Optimized procedures were applied to the determination of a mixture of six organochlorine pesticides in environmental liquid samples (sea, sewage and ground waters), employing HPLC with UV-diode array detector.  相似文献   

19.
A direct immersion solid-phase microextraction coupled with gas chromatography-electron capture detection (SPME-GC-ECD) method was optimized and validated for the quantitative determination of 18 organochlorine pesticides in ground water. Ionic strength, stirring speed, adsorption and desorption time and pH were some of the parameters investigated in order to select the optimum conditions for SPME with a 50/30 DVB/CAR/PDMS fiber coating. The SPME-GC/ECD method showed good linear response below 10 ng L−1 with R2 values in the range of 0.9950–0.9997. The repeatability of the measurements were lower than 10%. Values of relative recoveries located within the acceptable range (80–120%). Limits of quantification (LOQ) from 4.5 × 10−3 to 1.5 ng L−1 were obtained. On average 8 organochlorines were found per sample, even so all the 18 organochlorines were quantified among them. Substances such as endrin ketone, γ-BHC and β-BHC were the pesticides determined in larger concentration (0.06–305 ng L−1), while methoxychlor and aldrin in smaller amounts (0.151–1.55 ng L−1). Measured levels of organochlorine pesticides were above the limits established by Brazilian regulations.  相似文献   

20.
Gao Z  Li W  Liu B  Liang F  He H  Yang S  Sun C 《Journal of chromatography. A》2011,1218(37):6285-6291
A novel nano-structured polyaniline-ionic liquid (i.e. 1-butyl-3-methylimidazolium hexafluorophosphate, BMIPF(6)) composite (BPAN) film coated steel wire was prepared by electrochemical deposition. Scanning electron microscopy images showed that the obtained porous BPAN coating consisted of nanofibers, whose diameter ranged from 50 to 80 nm. Furthermore, the novel nano-structured composite coating was very stable at relatively high temperatures (up to 350 °C) and it could be used for more 250 times without obvious decrease of the extraction efficiency. The novel BPAN coating was used for the headspace solid-phase microextraction (HS-SPME) of organochlorine pesticides (i.e. hexachlorocyolohexane, dichlorodiphenyldichloroethylene, dichlorodiphenyldichloroethane, dichlorodiphenyltrichloroethane), coupled with gas chromatography-electron capture detection (GC-ECD). The BPAN coating showed better analytical capability on the whole compared with common polyaniline (PANI) and polydimethylsiloxane (PDMS) coatings. The key parameters influencing extraction efficiency were investigated and optimized, including desorption time, stirring speed, extraction temperature, extraction time and ionic strength. The relative standard deviations (RSDs) for single fiber repeatability ranged from 2.3 to 8.7% (n=6) and the RSDs for fiber-to-fiber reproducibility (n=6) were 4.2-12.1%, respectively. The linear ranges exceeded three magnitudes with correlation coefficients above 0.99. The detection limits were 0.12-0.31 ng L(-1). The proposed method was successfully applied for the determination of organochlorine pesticides in lake water, waste water and sewage treatment plant effluent with good recoveries from 88.9 to 112.9%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号