首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A collaborative study was conducted to compare a new enrichment procedure for the TECRA Salmonella Visual Immunoassay (TSVIA) with the reference method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (7th Ed.). Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 3 food types (milk chocolate, dried egg, and raw turkey) were analyzed in the United States. Thirty-eight collaborators participated in the study. The TECRA method was evaluated using both Rappaport-Vassiliadis R10 (RV(R10)) and tetrathionate (TT) broths for selective enrichment. M broth cultures arising from each of the 2 selective enrichment broths were tested in the TSVIA using 2 individual wells, one for each selective broth, and a single well to test the pooled selective enrichment broths. The results for the pooled enrichment broths were reported elsewhere. This study presents the results for the use of single enrichment broths, i.e., RV(R10) only or TT only, with the TSVIA. No significant differences (p > 0.05) were observed for the pairwise comparison of the proportion of positive samples for either RV(R10) or TT used as a single enrichment broth for the TSVIA with that for the reference method.  相似文献   

2.
The TECRA Unique Salmonella test uses the principle of immunoenrichment to allow rapid detection of Salmonellae in food. A collaborative study was conducted to compare the TECRA Salmonella Unique test with the reference culture method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual. Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 2 food types (milk chocolate and dried egg) were analyzed in the United States. Forty-one collaborators participated in the study. For each of the 5 foods at each of the 3 levels, a comparison showed no significant differences (p > or = 0.05) in the proportion of positive test samples for Unique and that for the reference method using the Chi-square test for independence with continuity correction.  相似文献   

3.
A collaborative study was conducted to validate new enrichment methods for the TECRA Listeria Visual Immunoassay (TLVIA). These new methods incorporate a newly formulated medium, TECRA Listeria Enrichrment Broth, which does not contain the highly toxic antifungal agent, cycloheximide. The new procedures will provide an alternative to the enrichment procedures described in AOAC Method 995.22. Three food types (raw ground beef, lettuce, and ice cream) were analyzed in the United States, and 2 food types (cooked turkey and cooked fish fillets) were analyzed in Australasia. Thirty collaborators participated in the study, 16 in Australasia and 14 in the United States. With the exception of one batch of ground beef, comparison of the proportion of positive test portions (p > or = 0.05) showed no significant difference between the TLVIA and the reference method for the 5 foods at 3 inoculation levels. For the one batch of naturally contaminated raw ground beef, the TLVIA gave significantly more confirmed positive results than the reference method.  相似文献   

4.
The TECRA Salmonella Visual Immunoassay (VIA) using Rappaport-Vassiliadis RV[R10] as a single selective enrichment broth has Final Action approval (AOAC Method 998.09). TECRA has recently developed a protocol (TECRA ULTIMA), which involves the addition of a new additive to a 1 mL aliquot of the RV[R10] broth, prior to the heat-killing step, thereby allowing the RV[R10] broth to be tested directly in the kit and thus eliminating the need for the 2 h post-enrichment in M broth. An in-house validation study was conducted to compare the modified AOAC Method 998.09 to the reference culture method. Three foods were used in the study: Naturally contaminated raw ground poultry at high (10-50 cells/25 g), and low (1-5 cells/25 g) levels; and milk powder and peanut butter, artificially inoculated at low and high levels with Salmonella bovismorbificans and S. enterica Mbandaka, respectively. Twenty test portions were analyzed for each level with 10 uninoculated control samples per food. Overall, no significant differences (p <0.05) were observed when the proportion of positive test portions for the modified VIA were compared with that for the reference method. This minor modification, which employs the additive (provided in the TECRA ULTIMA SALMONELLA Test Kit) to permit the direct analysis of RV[R10] broth has demonstrated the utility of the TECRA ULTIMA SALMONELLA protocol. It is recommended that the minor modification to Method 998.09 be approved First Action as an additional option within the method.  相似文献   

5.
A multilaboratory study was conducted to compare performance of the GeneQuence DNA hybridization (DNAH) method incorporating new 24 h enrichment protocols and reference culture procedures for detection of Salmonella spp. in select foods. Six food types (raw ground turkey, raw ground beef, dried whole egg, milk chocolate, walnuts, and dry pet food) were tested by the DNAH method and by the culture methods of either the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) or the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM). Fifteen laboratories participated in the study. Four of the foods tested (raw ground turkey, dried whole egg, milk chocolate, and dry pet food), showed no statistically significant differences in performance between the DNAH method and the reference procedure as determined by Chi square analysis. Sensitivity rates for the DNAH method ranged from 92 to 100%. The DNAH method, with the specific enrichment protocol evaluated, was found to be ineffective for detection of Salmonella spp. in walnuts. For raw ground beef, results from one trial showed a statistically significant difference in performance, with more positives obtained by the reference method. However, evidence suggests that the difference in the number of positives was likely due to lack of homogeneity of the test samples rather than to DNAH method performance.  相似文献   

6.
The VIDAS Salmonella (SLM) Easy Salmonella method is a specific enzyme-linked fluorescent immunoassay performed in the automated VIDAS instrument. The VIDAS Easy Salmonella method is a simple 2-step enrichment procedure, using pre-enrichment followed by selective enrichment in a newly formulated broth, SX2 broth. This new method was compared in a multilaboratory collaborative study to the U.S. Food and Drug Administration's Bacteriological Analytical Manual, Chapter 5 method for five food matrixes (liquid egg, vanilla ice cream, spinach, raw shrimp, and peanut butter) and the U.S. Department of Agriculture's Microbiology Laboratory Guidebook 4.04 method for deli turkey. Each food type was artificially contaminated with Salmonella at three inoculation levels. A total of 15 laboratories representing government, academia, and industry, throughout the United States, participated. In this study, 1583 samples were analyzed, of which 792 were paired replicates and 791 were unpaired replicates. Of the 792 paired replicates, 285 were positive by both the VIDAS and reference methods. Of the 791 unpaired replicates, 341 were positive by the VIDAS method and 325 were positive by the cultural reference method. A Chi-square analysis of each of the six food types was performed at the three inoculation levels tested. For all foods evaluated, the VIDAS Easy SLM method demonstrated results comparable to those of the reference methods for the detection of Salmonella.  相似文献   

7.
New enrichment protocols are described for use with a DNA hybridization (DNAH) method for detection of Salmonella spp. in select foods. GeneQuence Salmonella, in its original version, utilized a 3-stage enrichment of minimum 42 h duration. New 2-stage procedures of 24-28 h duration are described for raw poultry, raw beef, pasteurized egg products, milk chocolate, and dry pet food. In the validation study described here, a total of 345 samples were tested by the abbreviated DNAH method in parallel with either the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM) or U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedures. Results showed an overall sensitivity for the DNAH method of 97.1% (false-negative rate 2.9%). There were no false-positive results by the DNAH method; therefore the specificity was 100%. Overall agreement between the DNAH and reference culture methods was 98.5%. There were no significant differences in performance between the DNAH and reference methods for any of the foods tested as determined by Chi-square analysis. It is recommended that the DNAH method be subjected to AOAC collaborative study.  相似文献   

8.
The TECRA Staphylococcus aureus Visual Immunoassay allows a presumptive positive or negative result for the presence of S. aureus to be obtained within 26 h, in contrast to 4-5 days by traditional cultural methods. Presumptive positive immunoassay results are confirmed by streaking the enrichment broth onto conventional agar media. A validation study was undertaken to compare the TECRA assay with a cultural reference method based on the Bacteriological Analytical Manual (8th Ed.), which is also consistent with U.S. Pharmacopoeia requirements. The products tested included a range of cosmetics (toothpaste, shampoos, conditioners, sunscreens, moisturizers, lip and eye creams) and pharmaceuticals (cough mixtures, laxatives, ulcer treatments, infant formulae, antiseptic cream), as well as some pharmaceutical ingredients. Samples were inoculated with S. aureus at 10-20 cfu/g, and then enriched for 24 h at 35 degrees-37 degrees C at a product-to-sample ratio of 1:100. Two different enrichment broths were used for the study: Tryptone Soya Broth with 4% Tween 80 and Modified Letheen Broth. For both enrichment broths, results of the immunoassay and the reference method showed close correlation. The TECRA S. aureus Visual Immunoassay provides a rapid and convenient alternative to cultural methods and provides advantages to industry, such as greater speed of product and ingredient release and faster tracing of contamination problems. Because the immunoassay may be read either visually or with the aid of a plate reader, there is no need for an initial outlay on capital equipment. However, the assay can be automated if required.  相似文献   

9.
A collaborative study was conducted to compare the VIDAS Salmonella (SLM) with Rappaport-Vassiliadis (RV) method for detection of Salmonella in foods to the current standard method presented in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) and the culture method presented in AOAC's Official Methods of Analysis. The VIDAS SLM with RV method uses tetrathionate broth in combination with RV medium in place of selenite cystine broth for selective enrichment, thereby eliminating the hazardous waste issue for laboratories. Twenty five laboratories participated in the evaluation, each testing one or more of 8 test products: nonfat dry milk, dried egg, soy flour, lactic casein, milk chocolate, raw ground pork, raw ground turkey, and raw peeled shrimp. Results of the study showed no significant differences in the numbers of confirmed positive samples with the VIDAS SLM with RV procedure and the BAM/AOAC culture procedure. The VIDAS SLM with RV method was effective for rapid detection of Salmonella in foods. It is recommended that AOAC INTERNATIONAL modify the VIDAS Salmonella SLM procedure to include the RV method.  相似文献   

10.
Reveal Salmonella Enteritidis (SE) is a lateral flow-based immunodiagnostic assay used for rapid detection of Salmonella enterica serovar Enteritidis from pooled shell eggs and environmental samples. This assay uses highly specific antibodies to accurately detect S. Enteritidis. Studies were conducted to compare the performance of this test against reference procedures for detection of S. Enteritidis from both pooled shell eggs and environmental samples. Pooled shell eggs were inoculated with low levels ofS. Enteritidis and were enriched according to the procedure prescribed by the U.S. Food and Drug Administration. Uninoculated samples were included in each trial. Reveal SE exhibited 100% sensitivity and 100% specificity in comparison to the reference method in all trials. An abbreviated 48 h/(no hold) enrichment procedure was also developed and validated for detection ofS. Enteritidis from pooled shell egg samples. This shortened enrichment procedure can be used in conjunction with the Reveal SE test and offers a significant enrichment time savings of 96 h. Chi-square analysis revealed that there was no significant difference between the abbreviated Reveal method and the reference procedure for detection ofS. Enteritidis from pooled shell egg samples. Out of 245 natural drag swabs screened internally, only three samples tested Reveal SE positive and were confirmed by the reference procedure, resulting in 100% sensitivity and 100% specificity. An external laboratory screened 147 poultry house environmental samples and obtained 35 Reveal SE confirmed positives for Reveal SE sensitivity of 100% and specificity of 90%. Inoculation trials with drag swabs resulted in 96% sensitivity and 100% specificity. Thus, these data demonstrate that Reveal SE is a highly sensitive and specific assay for the detection of S. Enteritidis from both pooled shell eggs and environmental samples.  相似文献   

11.
Reveal Salmonella 2.0 is an improved version of the original Reveal Salmonella lateral flow immunoassay and is applicable to the detection of Salmonella enterica serogroups A-E in a variety of food and environmental samples. A Performance Tested Method validation study was conducted to compare performance of the Reveal 2.0 method with that of the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, raw shrimp, a ready-to-eat meal product, dry pet food, ice cream, spinach, cantaloupe, peanut butter, stainless steel surface, and sprout irrigation water. In a total of 17 trials performed internally and four trials performed in an independent laboratory, there were no statistically significant differences in performance of the Reveal 2.0 and reference culture procedures as determined by Chi-square analysis, with the exception of one trial with stainless steel surface and one trial with sprout irrigation water where there were significantly more positive results by the Reveal 2.0 method. Considering all data generated in testing food samples using enrichment procedures specifically designed for the Reveal method, overall sensitivity of the Reveal method relative to the reference culture methods was 99%. In testing environmental samples, sensitivity of the Reveal method relative to the reference culture method was 164%. For select foods, use of the Reveal test in conjunction with reference method enrichment resulted in overall sensitivity of 92%. There were no unconfirmed positive results on uninoculated control samples in any trials for specificity of 100%. In inclusivity testing, 102 different Salmonella serovars belonging to serogroups A-E were tested and 99 were consistently positive in the Reveal test. In exclusivity testing of 33 strains of non-salmonellae representing 14 genera, 32 were negative when tested with Reveal following nonselective enrichment, and the remaining strain was found to be substantially inhibited by the enrichment media used with the Reveal method. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device development time.  相似文献   

12.
Singlepath Salmonella is an immunochromatographic (lateral flow) assay for the presumptive qualitative detection of Salmonella spp. in food. The AOAC Performance-Tested Method study evaluated Singlepath Salmonella as an effective method for the detection of Salmonella spp. in the following selected foods: dried skimmed milk, black pepper, dried pet food, desiccated coconut, cooked peeled frozen prawns, raw ground beef, and raw ground turkey. When the foods were inoculated with Salmonella spp. at levels ranging from low [0.23-1.08 colony forming units (CFU)/25 g] to high (2.3-6.0 CFU/25 g), a Chi-square value of 0.9 indicated that there was no significant difference between Singlepath Salmonella and the ISO 6579:2002 reference method. Singlepath Salmonella gave a false-positive rate of 7.3% and a false-negative rate of 2.5%. For the inclusivity study, all 105 Salmonella serovars reacted with Singlepath Salmonella. For the exclusivity study, 58 non-Salmonella spp. were tested. There were no cross-reactions with Singlepath Salmonella from these strains.  相似文献   

13.
The relative effectiveness of the SimPlate Coliform and E. coli Color Indicator (CEc-CI) method was compared to the AOAC 3-tube Most Probable Number (MPN) methods for enumerating and confirming coliforms and Escherichia coli in foods (966.23 and 966.24). In this study, test portions were prepared and analyzed according to the conditions stated in both the AOAC methods and SimPlate directions for use. Six food types were artificially contaminated with coliform bacteria and E. coli: frozen burritos, frozen broccoli, fluid pasteurized milk, whole almond nut meats, cheese, and powdered cake mix. Method comparisons were conducted. Overall, the SimPlate method demonstrated <0.3 log difference for total coliform and E. coli counts compared to the AOAC reference methods for the majority of food types and levels analyzed. In all cases, the repeatability and reproducibility of the SimPlate CEc-CI method were not different from those of the reference methods and in certain cases, were statistically better than those of the AOAC 3-tube MPN methods. These results indicate that the SimPlate CEc-CI method and the reference culture methods are comparable for enumeration of both total coliforms and E. coli in foods.  相似文献   

14.
A Performance Tested Method validation study was conducted for a new lateral flow immunoassay (Reveal Listeria 2.0) for detection of Listeria spp. in foods and environmental samples. Results of inclusivity testing showed that the test detects all species of Listeria, with the exception of L. grayi. In exclusivity testing conducted under nonselective growth conditions, all non-listeriae tested produced negative Reveal assay results, except for three strains of Lactobacillus spp. However, these lactobacilli are inhibited by the selective Listeria Enrichment Single Step broth enrichment medium used with the Reveal method. Six foods were tested in parallel by the Reveal method and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) reference culture procedure. Considering data from both internal and independent laboratory trials, overall sensitivity of the Reveal method relative to that of the FDA/BAM procedure was 101%. Four foods were tested in parallel by the Reveal method and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedure. Overall sensitivity of the Reveal method relative to that of the USDA-FSIS procedure was 98.2%. There were no statistically significant differences in the number of positives obtained by the Reveal and reference culture procedures in any food trials. In testing of swab or sponge samples from four types of environmental surfaces, sensitivity of Reveal relative to that of the USDA-FSIS reference culture procedure was 127%. For two surface types, differences in the number of positives obtained by the Reveal and reference methods were statistically significant, with more positives by the Reveal method in both cases. Specificity of the Reveal assay was 100%, as there were no unconfirmed positive results obtained in any phase of the testing. Results of ruggedness experiments showed that the Reveal assay is tolerant of modest deviations in test sample volume and device incubation time.  相似文献   

15.
Six foods representative of a wide variety of processed, dried powder processed, and raw food types were analyzed by the Visual Immunoprecipitate Assay (VIP) for Salmonella and AOAC INTERNATIONAL culture method. Paired samples of each food type were simultaneously analyzed; one sample by the VIP method and one by the AOAC culture method. A total of 24 laboratories representing federal government agencies and private industry, in the United States and Canada, participated in this collaborative study. Food types were inoculated with species of Salmonella with the exception of raw ground chicken, which was naturally contaminated. No statistical differences (p < 0.05) were observed between VIP for Salmonella interpretation and the AOAC culture method for any inoculation level of any food type or naturally contaminated food. The method was adopted Official First Action status by AOAC INTERNATIONAL.  相似文献   

16.
A new DNA hybridization assay in microwell format for detection of Listeria spp. in foods and environmental samples was developed. This assay uses Listeria-specific oligonucleotide probes labeled with horseradish peroxidase and a photometrically determined end point. Validation studies with 15 different food commodities and a variety of environmental sample types were conducted to compare the performance of this alternative test versus reference methods. Meats, seafood, dairy products, and vegetables comprised the categories of food tested. Food samples were inoculated at 2 levels and refrigerated or frozen for at least 72 h. Uninoculated (negative) control samples were included in each trial. Samples were enriched according to the procedure recommended by either the U.S. Food and Drug Administration (FDA) or the U.S. Department of Agriculture (USDA), Food Safety and Inspection Service (FSIS). Samples enriched for 24 h were transferred to Oxford agar plates and incubated for 24 h. The surface of the plates was then swabbed and any growth present was transferred to phosphate buffer solution for the performance of the DNA assay. A standard confirmation procedure was used to compare the number of positive samples obtained with the DNA method versus reference methods. Statistical analyses of the results indicate that the proposed alternative method performs equally to cultural reference methods. The DNA assay is able to detect as low as 1 colony-forming unit of Listeria in a 25 g food sample, with results available as early as 48 h after the start of sample enrichment.  相似文献   

17.
Multiwalled carbon nanotubes were impregnated with 4-(2-thiazolylazo)resorcinol and used for the separation and preconcentration of Cd(II), Pb(II), Zn(II) and Ni(II) ions from food samples. The analytes were quantitatively recovered at pH 7.0 and eluted with 3?mol?L?1 acetic acid. The effects of pH value, flow rate, eluent type and sample volume on the recoveries, and the effects of alkali, earth alkali and transition metals on the retention of the analytes were studied. The method was validated using the standard certified reference materials SRM 1570A (spinach leaves) and IAEA 336 (lichen), and the results were found to be compatible with the certified values of reference materials. The new enrichment procedure was applied to the determination of these ions in various food samples.
Figure
Multiwalled carbon nanotubes were impregnated with 4-(2-thiazolylazo)resorcinol and used for the separation and preconcentration of Cd(II), Pb(II), Zn(II) and Ni(II) ions from food samples. The analytes were quantitatively recovered at pH 7.0 and eluted with 3 mol L-1 acetic acid. The method was validated using the standard certified reference materials SRM 1570A (spinach leaves) and IAEA 336 (lichen), and the results were found to be compatible with the certified values of reference materials. The new enrichment procedure was applied to the determination of these ions in various food samples.  相似文献   

18.
A multilaboratory study was conducted to compare the automated BAX System to the standard cultural methods for detection of Salmonella in selected foods. Five food types--frankfurters, raw ground beef, mozzarella cheese, raw frozen tilapia fish, and orange juice--at 3 inoculation levels, were analyzed by each method. A sixth food type, raw ground chicken, was tested using 3 naturally contaminated lots. A total of 16 laboratories representing government and industry participated. In this study, 1386 samples were analyzed, of which 1188 were paired samples and 198 were unpaired samples. Of the 1188 paired samples, 461 were positive by both methods and 404 were negative by both methods. Thirty-seven samples were positive by the BAX System but negative by the standard reference method, and 11 samples were positive by standard cultural method and negative by the BAX System. Of the 198 unpaired samples, 106 were positive by the BAX System and 60 were positive by the standard cultural method. A Chi square analysis of each of the 6 food types, at the 3 inoculation levels tested, was performed. For all foods, the BAX System demonstrated results comparable to those of the standard reference methods based on the Chi square results.  相似文献   

19.
In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.  相似文献   

20.
In the field of food quality, bovine milk products are of particular interest due to the social and economic importance of the dairy products market. However, the risk of fraudulent manipulation is high in this area, for instance, replacing milk powder by whey is very interesting from an economic point of view. Therefore, there is a need to have suitable analytical methods available for the determination of all milk components, which is currently not the case, especially for the main proteins. The detection of potential manipulations requires then a clear analytical characterisation of each type of bovine milk, what constitutes the goal of this work. The separation of the major milk proteinic components has been carried out by ion-pair reversed-phase HPLC with photodiode array detection, using a C4 column. The overall optimisation has been achieved using a statistical experimental design procedure. The identification of each protein was ascertained using retention times, peak area ratios and second derivative UV spectra. Quantification was based on calibration curves drawn using purified proteins. Major sources of uncertainty were identified and the full uncertainty budget was established. The procedure was initially developed using the skimmed milk powder certified reference material CRM 063R and then applied to various types of commercial milks as well as to raw milk. The method is able to separate and quantify the seven major proteins (K-casein, alphas2-casein, alphas1-casein, beta-casein, alpha-lactalbumin, beta-lactoglobulin B and beta-lactoglobulin A) in one run and also to provide precise determinations of the total protein concentration. These are important results towards the further development of a reference method for major proteins in milk. In addition, the use of a certified material reference is suggested in order to make comparisons of method performances possible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号