首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This article describes the comparison of different versions of an easy, rapid and low-cost sample preparation approach for the determination of pesticide residues in fruits and vegetables by concurrent use of gas and liquid chromatography (GC and LC) coupled to mass spectrometry (MS) for detection. The sample preparation approach is known as QuEChERS, which stands for “quick, easy, cheap, effective, rugged and safe”. The three compared versions were based on the original unbuffered method, which was first published in 2003, and two interlaboratory validated versions: AOAC Official Method 2007.01, which uses acetate buffering, and European Committee for Standardization (CEN) Standard Method EN 15662, which calls for citrate buffering. LC–MS/MS and GC–MS analyses using each method were tested from 50 to 1000 ng/g in apple–blueberry sauce, peas and limes spiked with 32 representative pesticides. As expected, the results were excellent (overall average of 98% recoveries with 10% RSD) using all 3 versions, except the unbuffered method gave somewhat lower recoveries for the few pH-dependent pesticides. The different methods worked equally well for all matrices tested with equivalent amounts of matrix co-extractives measured, matrix effects on quantification and chemical noise from matrix in the chromatographic backgrounds. The acetate-buffered version gave higher and more consistent recoveries for pymetrozine than the other versions in all 3 matrices and for thiabendazole in limes. None of the versions consistently worked well for chlorothalonil, folpet or tolylfluanid in peas, but the acetate-buffered method gave better results for screening of those pesticides. Also, due to the recent shortage in acetonitrile (MeCN), ethyl acetate (EtOAc) was evaluated as a substitute solvent in the acetate-buffered QuEChERS version, but it generally led to less clean extracts and lower recoveries of pymetrozine, thiabendazole, acephate, methamidophos, omethoate and dimethoate. In summary, the acetate-buffered version of QuEChERS using MeCN exhibited advantages compared to the other tested methods in the study.  相似文献   

2.
Use of pesticides has turned out to be an obligatory input to agriculture and public health. Versatile use of pesticides had resulted in contamination of all basic necessities of life, i.e. air, water and food. Among various pesticides, organophosphorus pesticides (OPPs), derivative of phosphoric acid, are the most extensively used insecticides or acaricides in many crops. Due to low persistency and high killing efficiency of OPPs, many agriculturalists regularly use this group of pesticides for various vegetables and fruits crops. The continuous use of pesticides has caused the deleterious effects to ecosystem. In response to this, a number of methods have been developed by several regulatory agencies and private laboratories and are applied routinely for the quantification and monitoring of multi pesticide residues in vegetables and crops. The present review pertains to various extraction and quantification procedures used world wide to analyze OPPs residues in various vegetables and fruits.  相似文献   

3.
Rice consumption has increased worldwide over recent decades, as it has become one of the most common foods. Although the analysis of environmental samples coming from rice areas has been well documented, there is less information regarding the analysis of pesticide residues in rice-grain samples.Rice (paddy, brown and white) can be considered a complex matrix, leading to difficulties in the application of the different multiresidue methods described in the literature. This review addresses and compares the principal extraction and clean-up methodologies [e.g., liquid-liquid extraction, solid-phase extraction, pressurized-liquid extraction, QuEChERS (quick, easy, cheap, effective, rugged and safe), gel-permeation chromatography and supercritical-fluid extraction - with QuEChERS-based methods being the most frequently employed].Traditionally, the determination of pesticide residues in rice has been based on gas chromatography with mass spectrometry (MS). But the application of new classes of pesticides has driven laboratories to increase the use of liquid chromatography with tandem MS. The limits of detection and quantification are in the ranges 0.09-90 μg/kg and 1-297 μg/kg, respectively, for the methodologies reported. These values agree with the current internationally-accepted maximum residue limits (MRLs).Based on the European Union (EU) database, more than 3000 analyses of pesticide residues in rice have been performed by official EU laboratories over the past decade. Of these, 6% reported pesticide residues above the MRLs.Physico-chemical properties can explain the occurrence of pesticides in rice commodities: lipophilic pesticides are frequently found in brown rice, whereas fungicides are mainly found in milled rice. Carbendazim, malathion, iprodione, tebuconazole, quinclorac and tricyclazole are the pesticides most frequently found in white rice, while buprofezin, hexaconazole, chlorpyrifos and edifenphos are most commonly found in paddy rice.Pesticide-residue concentrations can be affected during rice processing - with concentrations generally lower in the final products. However, few studies focusing on primary processing have addressed the setting of precise values applicable for the processing factors.  相似文献   

4.
1,2‐Benzenedicarboxylic acid esters, commonly referred to as phthalate esters, form a group of compounds that are mainly used as plasticizers in polymers. Because phthalate esters are not chemically bound to the plastics, they can be released easily from products and migrate into the food or water that comes into direct contact. Due to their widespread use, they are considered as ubiquitous environmental pollutants. Phthalate esters are regarded as endocrine disrupting compounds by means of their carcinogenic effect. Phthalate esters can be analyzed by gas chromatography or high‐performance liquid chromatography, however, their sensitivity and selectivity limit their direct use for determination of phthalates at very low level of concentrations exist in environmental samples with complex matrices. Therefore a sample pretreatment prior to their analysis is necessary. In this review, the historical development and overview of sample preparation methodologies have briefly been discussed and a comprehensive application of these methods in combination with different analytical techniques for preconcentration and determination of phthalate esters in various matrices have been summarized. Finally, a critical comparison of the different approaches in terms of enrichment factors achieved, extraction efficiency, precision, selectivity and simplicity of operation is provided.  相似文献   

5.
Pesticides are widely used in agriculture and can be transferred to animals in a number of ways. Consequently, reliable analytical methods are required to determine pesticide residues in foods of animal origin. The present review covers published methods and research articles (1990-2010) in which pesticide residues have been extracted from meat and meat products, milk and dairy products, fish and seafood, and eggs, then cleaned up, and isolated by chromatographic techniques to be identified and quantified by various detection methods. Recovery rates, quantification limits, the matrix effect and related parameters have all been considered. Lastly, future developments in this field are outlined.  相似文献   

6.
Direct injection and solid‐phase extraction methods for the determination of diquat and paraquat in surface and drinking water were developed using liquid chromatography with tandem mass spectrometry. The signal intensities of analytes based on six ion‐pairing reagents were compared with each other, and 12.5 mM nonafluoropentanoic acid was selected as the best suited amongst them. A clean‐up method was developed using Oasis hydrophilic–lipophilic balance; this was compared to the direct injection method, with respect to limits of detection, interference, precision, and accuracy. Limits of quantification of diquat and paraquat were 0.03 and 0.01 μg/L using the direct injection method, and 0.002 and 0.001 μg/L using the hydrophilic–lipophilic balance method. When the hydrophilic–lipophilic balance method was used to analyze target compounds in 114 surface water and 30 drinking water samples, paraquat and diquat were detected within a concentration range of 0.001–0.12 and 0.002–0.038 μg/L in surface water, respectively. When the direct injection method was used to analyze target compounds in the same samples, the detected concentrations of paraquat and diquat were within 25% in samples being >0.015 μg/L using the hydrophilic–lipophilic balance method. The liquid chromatography with tandem mass spectrometry method using direct injection can thus be used for routine monitoring of paraquat and diquat in surface and drinking water.  相似文献   

7.
Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites and degradation products, non-target suspected screening of an increasing number of residues, and even unknowns identification are also becoming inherent LC-MS advantages thanks to the latest advances. For routine analysis and, in particular, for official surveillance purposes in food control, analytical methods properly validated following strict guidelines are needed. After a brief introduction and an outline of the legislation applicable around the world, aspects such as improvement of specificity of high-throughput methods, resolution and mass accuracy of identification strategies and quantitative accuracy are critically reviewed in this article. In them, extraction, separation and determination are emphasized. The main objective is to offer an assessment of the state of the art and identify research needs and future trends in determining pesticide and veterinary drug residues in food by LC-MS.  相似文献   

8.
A demanding task in pesticide residue analysis is yet the development of multi-residue methods for the determination of pesticides in vegetables with relatively high fat content (i.e. edible oils and fatty vegetables). The separation of pesticides and other chemical contaminants from high-fat food samples prior to subsequent steps in the analytical process is yet a challenging issue to which much effort in method development has being applied. This review addresses the main sample treatment methodologies for pesticide residue analysis in fatty vegetable matrices. Even with the advent of advanced hyphenated techniques based on mass spectrometry these complex fatty matrices usually require extensive sample extraction and purification. Current methods involve the use of one or the combination of some of the following techniques for both the sample extraction and clean-up steps: liquid-liquid partitioning, solid-phase extraction (SPE), gel-permeation chromatography (GPC), matrix solid-phase dispersion (MSPD), etc. An overview of methods developed for these contaminants in fatty vegetables matrices is presented. Sample extraction and purification techniques are discussed and their most recent applications are highlighted. This review emphasizes that sample preparation is a critical step, but also the determination method is, and cannot be treated separately from sample treatment. In recent years, the appearance and use of new, more polar pesticides has fostered the development of liquid chromatography/mass spectrometry (LC-MS) besides gas chromatography. The main features of LC-MS for the analysis of multi-class pesticides in fatty vegetable samples will be also underlined, with an emphasis on the multi-class, multi-residue strategy and the difficulties associated.  相似文献   

9.
A critical review is made on the use of hyphenated liquid chromatography/mass spectrometry (LC–MS) for the identification and quantification of pesticides and their metabolites in human biosamples (whole blood, plasma, serum and urine). The first applications of LC–MS in this field began in the early 1990s. Since then, increasing interest has been shown in applying this powerful technique, with most applications dealing with the determination of a variety of chemically diverse metabolites in urine. The use of different LC–MS interfaces and mass spectral detection modes are discussed. Special attention is given to tandem mass spectrometry (MS/MS) due to its inherent advantages of increased sensitivity and selectivity, as well as its advantages for identification and confirmation of analytes in samples. Quantification can be severely affected by matrix effects, the most common being inhibition of the ionisation of analytes in the mass spectrometer, which leads to unacceptable errors if no correction is made. Different approaches can be employed to minimise this undesirable matrix effect, the preferred being the use of labelled internal standards (when available) in isotope dilution methods or the application of an efficient clean-up, performed off-line or automated on-line. Adequate criteria for confirming the identities of residues detected are required in order to avoid false positives. The criterion most commonly used with a triple quadrupole instrument is the monitoring of two MS/MS transitions together with the ion abundance ratio. TOF mass analysers are seldom used in pesticide residue analysis despite their improved resolution and mass accuracy characteristics, which makes them very suitable for confirmation purposes. The main reasons for the relative unpopularity of TOF MS in residue analysis are its limited sensitivity and its high acquisition cost. In this paper, we present a critical assessment on current techniques, trends and future developments, and give illustrative examples to point out the main characteristics of LC–MS for pesticide residue analysis in biological fluids.  相似文献   

10.
In this review, recent developments for the determination of emerging organic contaminants (EOCs) in plant tissues are discussed focusing on the homogenization, extraction and determination steps involved. Eleven classes of EOCs, namely antibiotics, analgesics, antiepileptics, antidepressants, antiseptics, plasticizers, fragrances, surfactants, flame retardants, and phenoxy acid herbicides, have been evaluated. Methods are critically reviewed in terms of all the analytical steps involved in the analysis, sampling and sample preparation, separation, and the detection strategies employed. The extraction from tissue samples was performed in most cases by solid–liquid extraction, whereas the clean-up was performed by solid-phase extraction. The identification and quantification of EOCs in crops from the agricultural field (i.e. parts per billion range) is usually performed by using mass spectrometry techniques such as single quadrupole mass spectrometry or tandem mass spectrometry coupled to high resolution chromatographic techniques. Enzyme-linked immunosorbent assays are more rarely used. New developments such as in vivo solid-phase microextraction (SPME) and the assessment of the bioavailability–bioaccesibility of contaminants in crops are shown. The main scope of this review is to critically evaluate the current state of the art of the analytical techniques used and to identify the research needs in the determination of EOCs in crops.  相似文献   

11.
Until now, time-of-flight (TOF) mass analysers have only been very rarely used in pesticide residue analysis (PRA) of water samples. However, the inherent characteristics of TOF MS make these analysers well-suited to this field, mainly for qualitative purposes. Thus, the high sensitivity obtained from full-scan acquisition in comparison to other MS analysers and the high resolution of TOF MS suggest its suitability for screening purposes; it also increases the multiresidue capabilities of methods based on it and decreases the chance of recording false positives. Although these characteristics can also be helpful for quantification, confirmation and elucidation, some limitations on the use of TOF for these purposes have been observed. These limitations are more noticeable when dealing with samples containing very low analyte concentrations, which is the normal situation for PRA in water. The use of hybrid quadrupole–time-of-flight instruments (QTOF) minimises the limitations of TOF, facilitating the simultaneous detection and unequivocal confirmation of pesticides found in the sample. Additionally, the acquisition of accurate product ion full-scan mass spectra can help to elucidate the structures of unknown compounds. In this paper, the potential of TOF and QTOF hyphenated to liquid chromatography for PRA in water is explored, emphasizing both the advantages and limitations of this approach for screening, quantification, confirmation and elucidation purposes. Emphasis is placed on the determination of polar pesticides and transformation products—the analytes that fit well with LC–API–(Q)TOF MS technology.  相似文献   

12.
Gasoline, diesel, ethanol and more recently also biodiesel are the four types of fuel used for automobile, truck and other transportation vehicle. The presence of metallic and metalloid species in automotive fuels is undesirable, except in the form of additives in order to improve specific characteristics of the fuel. Metallic or metalloid elements may derive from the raw product, such as nickel and vanadium in petroleum-based fuel or phosphorus in biodiesel, or they may be introduced during production and storage, such as copper, iron, nickel and zinc in case of petroleum-based fuel and alcohol or sodium and potassium in the case of biodiesel. The most famous additive to fuel is undoubtedly lead, the use of which has been banned or drastically reduced now in many countries of the world. The problems related to the trace element content may be economic, such as fuel degradation and poisoning of automotive catalysts, and/or environmental, such as the emission of metal compounds to the atmosphere. The analytical methods that have been developed for metal and metalloid quantification in automotive fuel are reviewed in this article. The main atomic spectrometric techniques used for trace metal and metalloid determination in fuels, particularly atomic absorption spectrometry with flames, graphite furnaces and with chemical vapor generation, and inductively coupled plasma coupled with optical emission and mass spectrometry are presented, including the different sample preparation procedures proposed for these techniques.  相似文献   

13.
In the present work, a review of the analytical methods developed in the last 15 years for the determination of endocrine disrupting chemicals (EDCs) in human samples related with children, including placenta, cord blood, amniotic fluid, maternal blood, maternal urine and breast milk, is proposed. Children are highly vulnerable to toxic chemicals in the environment. Among these environmental contaminants to which children are at risk of exposure are EDCs —substances able to alter the normal hormone function of wildlife and humans—. The work focuses mainly on sample preparation and instrumental techniques used for the detection and quantification of the analytes. The sample preparation techniques include, not only liquid–liquid extraction (LLE) and solid-phase extraction (SPE), but also modern microextraction techniques such as extraction with molecular imprinted polymers (MIPs), stir-bar sorptive extraction (SBSE), hollow-fiber liquid-phase microextraction (HF-LPME), dispersive liquid–liquid microextraction (DLLME), matrix solid phase dispersion (MSPD) or ultrasound-assisted extraction (UAE), which are becoming alternatives in the analysis of human samples. Most studies focus on minimizing the number of steps and using the lowest solvent amounts in the sample treatment. The usual instrumental techniques employed include liquid chromatography (LC), gas chromatography (GC) mainly coupled to tandem mass spectrometry. Multiresidue methods are being developed for the determination of several families of EDCs with one extraction step and limited sample preparation.  相似文献   

14.
Pesticides are widely applied and they can produce a variety of transformation products (TPs), through different pathways and mechanisms. Nowadays there is a growing interest related to the determination of pesticide TPs in several matrices (environmental, food and biological samples), due to these compounds can be more toxic and persistent than parent compounds, and some of them can be used as markers of exposure to different pesticides. Although solid-phase extraction (SPE) is mainly used for the extraction of TPs, alternative techniques such as solid-phase microextraction (SPME) and liquid-phase extraction (LPE) can be used. These TPs are mainly determined by liquid chromatography (LC) due to the recent developments in this technique, especially when it is coupled to mass spectrometry (MS) detectors, allowing the determination of known and/or unknown TPs. Furthermore, MS is a very valuable tool for the structural elucidation of unknown TPs. This review discusses all phases of analytical procedure, including sample treatment and analysis, indicating the main problems related to the extraction of TPs from several matrices due to their high polarity, as well as the different alternatives found for the simultaneous determination of parent compounds and TPs, using chromatographic techniques coupled to MS detection.  相似文献   

15.
Urocanic acid is a chromophore found in the skin that has been identified as an important immunosuppressant and carcinogenesis mediator through its photoisomerization from trans to cis form induced by ultraviolet radiation. Research on analytical methods that explore urocanic acid isomerization is indispensable to fully understand the deleterious effects mediated by this biomarker. In this context, the current relevant analytical methods for determination of these isomers in human samples are summarized in this review. The methods presented here are applicable to human samples collected by noninvasive methods (or minimally invasive), encompassing an array of analytical techniques, including high‐performance capillary electrophoresis, confocal Raman spectroscopy, gas chromatography, high‐performance liquid chromatography, and mass spectrometry, among others. Developed high‐performance liquid chromatography methods have proven to be advantageous, allowing noninvasive collections for in vivo analysis and the confocal Raman, specially, for real‐time analysis. Among all these methods, high‐performance liquid chromatography is the most investigated one with mass spectrometry or ultraviolet detector, and the mass spectrometry detector being the most studied in the last years, demonstrating high sensitivity, very low detection limits, and accurate identification, especially for clinical investigations.  相似文献   

16.
Automatic pesticide screening has been performed by use of a macro program to compare mass spectra acquired during GC-MS with those in designated mass spectral libraries containing a limited number of target compounds. The automated evaluation procedure has enabled fast recognition of pesticides in complex chromatograms.  相似文献   

17.
A multiresidue method for the determination of more than 80 pesticides in water has been developed and validated. The proposed method is based on SPE followed by GC coupled to MS/MS. Different variables affecting SPE procedure, such as cartridges, sample volume and solvents were studied, and mass spectrometric conditions were optimised in order to increase selectivity and sensitivity. Calibration curves were linear over the range of 0.03-0.5 microg/L. Recoveries were in the range of 70-110% and repeatability was below 20% for the lowest calibration point. LODs ranged from 0.001 to 0.025 microg/L and LOQs from 0.003 to 0.076 microg/L. Finally, the method was successfully applied to the analysis of water samples from southeast of Spain.  相似文献   

18.
A simple, rapid, and efficient ultrasound‐assisted emulsification microextraction method followed by gas chromatography mass spectrometry in selected ion monitoring mode was developed for the determination of organochlorine pesticides in honey samples. The type and volume of organic extraction solvent, pH, effect of added salt content, and centrifuging time and speed were investigated. Under the optimum extraction conditions, 30 μL of 1, 2‐dibromoethane (extraction solvent) was immersed into an ultrasonic bath for 1 min at 40°C. The limits of detection and quantification for all target pesticides were 0.003–0.06 and 0.01–0.2 ng/g, respectively. The extraction recovery was 91–100% and the enrichment factors were 168–192. The relative standard deviation for the method was <6% for intraday (n = 6) and <8% for interday precision (n = 4). The proposed method was successfully applied for the analysis of organochlorine pesticides in honey samples.  相似文献   

19.
This paper is a review of ion chromatographic (IC) separations of inorganic oxyhalide disinfection by-products (DBPs) in water and beverages. The review outlines the chemical mechanisms of formation, regulation of maximum allowable levels, chromatographic column selection and speciation. In addition, this review highlights the application of IC coupled to mass spectrometry (MS) for trace and elemental composition analysis of oxyhalides, along with the analytical considerations associated to enable sensitive analysis. Furthermore, a review of literature concerning IC determination of inorganic oxyhalide DBPs in environmental matrices, including water, published since 2005 is presented, with a focus on MS detection, and a discussion on the relative performance of the methods. Finally some prospective areas for future research, including fast, selective, multi-analyte analysis, for this application are highlighted and discussed.  相似文献   

20.
Since the discovery of their toxicity to aquatic environments, antifouling booster biocides (ABBs) have been widely researched and detected at trace levels in diverse environmental compartments including water, sediment, and, less frequently, biota. Hence, the reliable assessment of environmental risks posed by ABBs requires the development of analytical methods sufficiently robust, accurate, and precise for the simultaneous trace-level determination of ABBs. Herein, we summarize outstanding sample preparation procedures for the analysis of main ABBs in environmental matrices, describing techniques ranging from traditional extraction methods to novel miniaturized and micro-extraction ones, which have recently received much attention due to their reduced number of steps, low operational cost, and greater respect for the environment. The main applied chromatographic-based methods coupled to different detection techniques are also addressed. Despite the recent development of numerous ABBs determination methods, this topic continues to draw attention because of the lack of standardization among methods, despite legislation set up maximum standards levels for selected ABBs, and the need to monitor ABB transformation products for a reliable ecological risk assessment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号