首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Micellar electrokinetic capillary chromatography (MEKC) has been developed as a promising method for the determination of lignans in plant samples. The separation conditions have been optimized with respect to the different parameters including sodium dodecyl sulfate (SDS) and acetonitrile concentration, pH of the background electrolyte, separation voltage, and capillary temperature. The background electrolyte consisting of 40 mM SDS and 35% acetonitrile in 10 mM tetraborate buffer (pH 9.3) was found to be the most suitable electrolyte for this analysis. The applied voltage of 28 kV (positive polarity) and the capillary temperature 25 degrees C gave the best separation of lignans. The interday reproducibility of the peak areas and the migration times was below 2.0%. The results of MEKC analyses were compared with those obtained by capillary electrochromatography (CEC) and reversed-phase high-performance liquid chromatography (RP-HPLC). The possibilities of using this method for the determination of lignans in drug and in serum samples were also tested.  相似文献   

2.
Phytochemical investigation of the fruit of Schisandra chinensis led to the isolation of a schisanartane nortriterpenoid, schindilactone H (1); an 18-norschiartane bisnortriterpenoid, wuweizidilactone I (2); two tetrahydrofuran-type lignans, schinlignins A and B (18 and 19); and three dibenzyl butane-type lignans, schineolignins A-C (20-22), together with 16 known compounds. The structures of these new compounds were elucidated on the basis of extensive analysis of spectroscopic data.  相似文献   

3.
Considering the current interest in capillary electrochromatography (CEC), performed in packed columns, we present the different methods used to pack capillary columns for use in CEC. General considerations on column packing are given and the column fabrication process is discussed in sufficient detail to allow instruction to those who are not experienced in the field. Five different packing methods are discussed to deliver packing material into the capillary column from a practical view point: slurry pressure packing, packing with supercritical CO2, electrokinetic packing, using centripetal forces, and packing by gravity. Entrapment of particulate material by sintering and sol-gel technology is also mentioned. Although slurry pressure packing procedures are most common, higher separation efficiencies are obtained using other packing approaches. Electrokinetic packing seems to be the simplest technique to deliver the packing material into the capillary columns. Nevertheless, as with the other packing techniques, skill and experience are required to complete all the steps involved in the fabrication of packed columns for CEC.  相似文献   

4.
Tian K  Qi S  Cheng Y  Chen X  Hu Z 《Journal of chromatography. A》2005,1078(1-2):181-187
In this paper, a micellar electrokinetic chromatographic (MEKC) method using ionic liquid as modifier for the quantification of the active components of lignans found in the medicinal herbs Schisandra species was developed for the first time. Preliminary investigations employing sodium dodecyl sulfate (SDS) as surfactant did not lead to the necessary resolution of the studied compounds, the addition of ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate (BMIM-BF4) to the SDS micellar system resulted in the complete separation of all the compounds. The effects on the separation by several parameters such as BMIM-BF4 and SDS concentration, applied voltage, background electrolyte pH and concentration, were evaluated. Under the optimal conditions (5 mM borate-5 mM phosphate buffer in the presence of 20 mM SDS and 10 mM BMIM-BF4, pH 9.2, applied voltage 25 kV and detection at 254 nm), the method successfully applied to the determination of lignans in extracts of Schisandra chinensis (Turcz.) Baill. and Schisandra henryi C.B. Clarke in less than 13 min. The separation mechanism was also discussed.  相似文献   

5.
应用自主研发的具有分离-富集模式的制备色谱工厂,建立了分离制备五味子木脂素有效部位及其单体化合物的方法。该方法首先以C18(250 mm×4.6 mm,5 μm)为色谱柱,水和甲醇为流动相,分离度和保留时间为考察指标,采集4个不同梯度的色谱信息,通过XTool色谱专家系统软件模拟,确定五味子木脂素第一、二维色谱条件;然后采用线性放大的方法,以C18(250 mm×30 mm,10 μm)为第一、二维分离柱,C18(80 mm×30 mm,10 μm)为富集柱,水为富集稀释液,对五味子木脂素进行二维色谱分离纯化;最后第一维分离得到9个可重复组分,第二维分离得到20个高纯度化合物,其中有6个单体化合物。结果表明该法重现性良好,可以实现五味子木脂素的系统性分离,对五味子化学成分的研究具有重要意义。  相似文献   

6.
Methacrylate-ester-based monoliths containing quaternary ammonium groups were prepared in situ in capillary columns and in simultaneous experiments in vials, employing thermal initiation. The chromatographic properties of the monoliths were determined with capillary electrochromatography (CEC), and their morphology was studied with mercury-intrusion porosimetry on the bulk materials. Materials with different, well repeatable pore-size distributions could be prepared. A satisfactory column-to-column and run-to-run repeatability was obtained for the electro-osmotic mobility, the retention characteristics (k-values) and the efficiency on the columns prepared and tested in the CEC mode. A relatively high electro-osmotic flow was observed in the direction of the positive electrode. The electro-osmotic mobility was found to be influenced only marginally by mobile-phase parameters such as the pH, ionic strength, and acetonitrile content. The retention behavior of the monolithic columns was similar to that of columns packed with C18-modified silica particles. Columns could be prepared with optimum plate heights ranging from 6 microm for unretained compounds to 20 microm for well retained (k=2.5) polyaromatic hydrocarbons. However, for specific analytes a - still unexplained - lower chromatographic column efficiency was observed.  相似文献   

7.
This review summarizes recent developments in the field of enantiomer separation by capillary electrochromatography using fritless packed columns. Various enantiomers have been separated by employing fritless packed columns prepared in a fused silica capillary either by the immobilization of chiral packing materials by sintering or sol-gel technology or by in situ polymerization of a mixture containing chiral selectors. The details of the column preparation procedures and the attainable column performance are described.  相似文献   

8.
In this study, the molecular imprinting method was used to separate enantiomeric forms of chiral antidepressant drug, R,S-citalopram (R,S-CIT) in aqueous solution by CEC system combining the advantages of capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC). For that, an amino acid-based molecularly imprinted monolithic capillary column was designed and used as a stationary phase for selective separation of S-citalopram (S-CIT) for the first time. S-CIT was selectively separated from the aqueous solution containing the other enantiomeric form of R-CIT, which is the same in size and shape as the template molecule. Morphology of the molecularly imprinted (MIP S-CIT) and non-imprinted (NIP S-CIT) monolithic capillary columns was observed by scanning electron microscopy. Imprinting efficiency of MIP S-CIT monolithic capillary column used for selective S-CIT separation was verified by comparing with NIP S-CIT and calculated imprinting factor (I.F:1.81) proved the high selectivity of the MIP S-CIT for S-CIT. Cavities formed for S-CIT form enabled selective (α = 2.08) separation of the target molecule from the other enantiomeric R-CIT form. Separation was achieved in a short period of 10 min, with the electrophoretic mobility of 7.68 × 10−6 m2/Vs for R,S-CIT at pH 7.0 10 mM PB and 50% ACN ratio. The performance of both MIP S-CIT and NIP S-CIT columns was estimated by repeating the R,S-CIT separations with intra-batch and inter-batch studies for reproducibility of retention times of R,S-CITs. Estimated RSD values that are lower than 2% suggest that the monolithic columns separate R,S-CIT enantiomers without losing separation efficiency.  相似文献   

9.
Designed especially for capillary electrochromatography (CEC), silicate-entrapped columns are made by trapping particles of chromatographic packing material in a network of silica. Once entrapped, the capillary no longer requires frits. This renders a more homogeneous and stable packed bed. Accidental breakage of the fragile frits is not an issue with these robust columns. Columns packed with reverse-phase material subjected to silicate entrapment demonstrated faster separations of retained analytes and increased efficiencies compared with nonentrapped columns. The method was also used to prepare chiral CEC columns by entrapping a molecular imprinted polymeric (MIP) packing having minimal surface charge density, thus being unable alone to support sufficient electroosmotic flow for CEC.  相似文献   

10.
In this study, eight benzophenones, which are commonly used as UV filters in various cosmetics and plastics, were analyzed by capillary electrochromatography with a methacrylate ester-based monolithic column. The effects of the composition and pH of mobile phase, porogenic solvent ratio, and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) content on benzophenone separations were examined. For all benzophenones, separation performances were markedly improved in monolithic columns with larger 1-propanol ratio and higher AMPS content. Furthermore, a twofold increase in AMPS content almost reduced the separation time in half when a monolithic column had an adequately high surface area, i.e. monolithic column was produced in a higher ratio of 1-propanol. As well, the retention behaviors of these analytes in the monolithic column were strongly influenced by the level of acetonitrile in the mobile phase, and the pH of the mobile phase also had an apparent influence on separation resolution.  相似文献   

11.
A study was carried out in which 50 microm I.D. fused-silica capillaries were packed with 3 microm octadecylsilane bonded silica, from the same batch, by four methods; liquid slurry and carbon dioxide supercritical carrier, each with and without the use of an ultrasonic probe. A neutral test mixture was analysed by capillary column in reversed-phase mode, and the reproducibility of the electroosmotic flow and of migration time, column efficiency and retention factors, was determined. Initially results suggested that there was no significant difference between properties of columns packed by different methods, and a more thorough statistical evaluation confirmed this; differences observed in the column performance were attributed to random variations between replicate columns, and not between packing methods. However, the variation was least when applying the ultrasonication during liquid slurry.  相似文献   

12.
Huang HY  Chiu CW  Huang IY  Yeh JM 《Electrophoresis》2004,25(18-19):3237-3246
Five common food preservatives were analyzed by capillary electrochromatography, utilizing a methacrylate ester-based monolithic capillary as separation column. In order to optimize the separation of these preservatives, the effects of the pore size of the polymeric stationary phase, the pH and composition of the mobile phase on separation were examined. For all analytes, it was found that an increase in pore size caused a reduction in retention time. However, separation performances were greatly improved in monolithic columns with smaller pore sizes. The pH of the mobile phase had little influence on separation resolution, but a dramatic effect on the amount of sample that was needed to be electrokinetically injected into the monolithic column. In addition, the retention behaviors of these analytes were strongly influenced by the level of acetonitrile in the mobile phase. An optimal separation of the five preservatives was obtained within 7.0 min with a pH 3.0 mobile phase composed of phosphate buffer and acetonitrile 35:65 v/v. Finally, preservatives in real commercial products, including cold syrup, lotion, wine, and soy sauces, were successfully determined by the methacrylate ester-based polymeric monolithic column under this optimized condition.  相似文献   

13.
CEC is a high performance electrodriving liquid phase separation technique. It does not need complex and sophisticated high pressure instrumentation for nanoflow driving. This is attractive for parallel multicolumn analysis. To this end, high throughput methods for column preparation are needed to support the use of multiple columns. In this study, we directly used CEC mobile phase solution as the packing solvent, and realized rapid preparation of capillary columns based on a single particle fritting technology. The method presented high preparation throughput compared with other reported methods based on various fritting technologies. The single particle fritting approach promoted column preparation throughput to 1 column/h, including all the fritting, packing and conditioning steps. The rapidly prepared columns showed consistently high efficiency of up to 150 000 plates per meter, and usefulness in reversed phase CEC of neutral, charged and biomolecules. With standard peptides as the sample, excellent long term reproducibility (better than 0.8%RSD, ten days, for retention times) was observed.  相似文献   

14.
A novel approach is introduced and evaluated for the preparation of silica-based monoliths by a sol–gel technique where in situ polymerization was carried out by γ-ray irradiation within the capillary. The γ-radiation-initiated synthesis generated radicals directly on the monomer, thereby avoiding use of any initiator. The chromatographic behavior of the capillary monolithic columns was studied in the modes of CEC, p-CEC and low pressure-driven separation, all of which exhibited reversed-phase character. Various operational parameters, such as column temperature, separation voltage, acetonitrile content and buffer pH, were varied to assess their influence on column performance in the separation of a series of neutral compounds including thiourea, benzene, toluene, ethyl benzene, biphenyl and naphthalene. A scanning electron micrograph of a cross-section of the capillary column showed that the gel took the form of a spherical particle aggregate and adhered to the column inner wall. It provided a viable alternative to either thermally initiated or photo polymerization for the preparation of monolithic columns.  相似文献   

15.
Malik A 《Electrophoresis》2002,23(22-23):3973-3992
The development of sol-gel open-tubular column technology in capillary electrochromatography (CEC) is reviewed. Sol-gel column technology offers a versatile means of creating organic-inorganic hybrid stationary phases. Sol-gel column technology provides a general approach to column fabrication for microseparation techniques including CEC, and is amenable to both open-tubular and monolithic columns. Direct chemical bonding of the stationary phase to the capillary inner walls provides enhanced thermal and solvent stability to sol-gel columns. Sol-gel stationary phases inherently possess higher surface area, and thus provide an effective one-step alternative to conventional open-tubular column technology. Sol-gel column technology is applicable to both silica-based and transition metal oxide-based hybrid stationary phases, and thus, provides a great opportunity to utilize advanced material properties of a wide range of nontraditional stationary phases to achieve enhanced selectivity in analytical microseparations. A wide variety of stationary phase ligands can be chemically immobilized on the capillary inner surface using a single-step sol-gel procedure. Sol-gel chemistry can be applied to design stationary phases with desired chromatographic characteristics, including the possibility of creating columns with either a positive or a negative charge on the stationary phase surface. This provides a new tool to control electroosmotic flow (EOF) in the column. Column efficiencies on the order of half a million theoretical plates per meter have been reported for sol-gel open-tubular CEC columns. The selectivity of sol-gel stationary phases can be easily fine-tuned by adjusting the composition of the coating sol solution. Open-tubular columns have significant advantages over their packed counterparts because of the simplicity in column making and hassle-free fritless operation. Open-tubular CEC columns possess low sample capacity and low detection sensitivity. Full utilization of the analytical potential of sol-gel open-tubular columns will require a concomitant development in the area of high-sensitivity detection technology.  相似文献   

16.
Porous sol-gel frits are fabricated in a capillary column by filling it with a solution of 3-(trimethoxysilyl)propyl methacrylate, hydrochloric acid, water, toluene (porogen), and a photoinitiator (Irgacure 1800) and exposing it to UV light at 365 nm for 5 min. The separation column (30 cm x 75 microm I.D.) contains between the inlet and outlet frits a 15-cm packed segment filled with 5-microm silica particles modified with the chiral compound (S)-N-3,5-dinitrobenzoyl-1-naphthylglycine. A detection window (1 mm long) is placed immediately after the outlet frit. To demonstrate the performance of this chiral separation column, mixtures of 16 different amino acids (three of which are not naturally occurring) derivatized with the fluorogenic reagent 4-fluoro-7-nitro-2,1,3-benzoxadiazole were separated by capillary chromatography. The enantiomeric separation of the column results in a resolution ranging from 1.21 to 8.29, and a plate height ranging from 8.7 to 39 microm.  相似文献   

17.
Immobilized liposome chromatography (ILC) has been proven to be a useful method for the study or rapid screening of drug-membrane interactions. To obtain an adequate liposomal membrane phase for ILC, unilamellar liposomes were immobilized in gel beads by avidin-biotin binding. The retardation of 15 basic drugs on the liposome column could be converted to membrane partitioning coefficients, K(LM). The effects of small or large unilamellar liposomes and multilamellar liposomes on the drug-membrane partitioning were compared. The K(LM) values for both small and large liposomes were similar, but higher than those for the multilamellar liposomes. The basic drugs showed stronger partitioning into negatively charged liposomes than into either neutral liposomes or positively charged liposomes. The membrane fluidity of the immobilized liposomes was modulated by incorporating cholesterol into the liposomal membranes, by changing the acyl chain length and degree of unsaturation of the phospholipids, and by changing the temperature for ILC runs. Our data show that K(LM) obtained using ILC correlated well with those reported by batch studies using free liposomes. It is concluded that negatively charged or cholesterol-containing large unilamellar liposomes are suitable models for the ILC analysis of drug-membrane interactions.  相似文献   

18.
A series of micro-monolithic columns with different porosities were prepared for capillary electrochromatography (CEC) by in-situ copolymerization of butyl methacrylate, ethylene glycol dimethacrylate, and 2-acrylamido-2-methyl-1-propane-sulfonic acid in the presence of a porogen in fused-silica capillaries of 100 microm I.D. Different column porosities were obtained by changing the ratios of monomers to porogenic solvents. Columns were investigated and evaluated under both pressure-driven (high-performance liquid chromatography, HPLC) and electro-driven (capillary electrochromatography, CEC) conditions. Each column exhibited different efficiency and dependency on flow velocity under electro-driven conditions. Abnormally broad peaks for some relatively bulky molecules were observed. Possible explanations are discussed. The differences in column efficiency and retention behavior between the two eluent-driven modes were studied in detail. In addition, other column properties, such as morphology, porosity, stability and reproducibility, were extensively tested.  相似文献   

19.
20.
The need for novel packing materials in both capillary electrochromatography (CEC) and capillary liquid chromatography (CLC) is apparent and the development towards more selective, application-oriented chromatographic phases is under progress world-wide. In this study we have synthesized new polyethyleneimine (PEI) functionalized Mn(2)O(3), SiO(2), SnO(2), and ZrO(2) particles for the fabrication of packed capillary columns for CEC and CLC. The nanocasting approach was successful for the preparation of functionalized metal oxide materials with a controlled porosity and morphology. PEI functionalization was done using ethyleneimine monomers to create particles which are positively charged in aqueous solution below pH 9. This functionalization allowed the possibility to have both hydrophobic (due to its alkyl chain) and ionic interactions (due to positively charged amino groups) with selected compounds. For comparison aminopropyl-functionalized silica was also synthesized and tested. Both slurry pressure and electrokinetic packing procedures used gave similar results, but fast sedimentation of the material caused some problems during the packing. The high stability and wide pH range of PEI-functionalized SiO(2) material, with potential for hydrophobic and electrostatic interactions, proved to be useful for the CEC and CLC separation of some model acidic and neutral compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号