首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Rigid spherical macroporous adsorbent beads with surface hydroxyl groups were prepared by cross-linking of cellulose. These beads had diameter in the range 100-200 microm and a mean pore size of about 3 microm with about 60% pore volume. The matrix (bulk density approximately 1600 kg m(-3)) could be expanded into a stable bed and used for protein chromatography. Chromatographic runs were performed on a 10 mm diameter column under non-retaining and retaining conditions on the prepared matrix (called Celbeads) and performance of the runs was measured in terms of the height equivalent to a theoretical plate (HETP). The HETP curves in both packed and expanded bed modes followed profiles typical of macroporous adsorbents, i.e. increasing and levelling with velocity. Unimpaired performance of the matrix at increasing flow-rates permitted expanded bed elution of adsorbed solutes without loss of efficiency in terms of purification factor and product concentration. As a model system, Celbeads was used to purify lactate dehydrogenase from porcine muscle homogenate by dye-affinity chromatography. The prepared matrix provided about 100 theoretical plates per meter for the enzyme system at a linear flow velocity of 1.27 cm x min(-1) in an expanded bed elution mode, and gave enzyme yields of 100% with a purification factor of 31 using an optimized procedure. The adsorbent could be cleaned in place with 5 M urea and used repeatedly without loss of performance.  相似文献   

2.
The present paper describes a chromatographic capture/purification step for the recovery of proteins directly from undiluted and unclarified cell culture broths using supermacroporous dimethylacrylamide (DMAA) cryogel. The interconnected character and the size (10-100 microm) of the pores of the adsorbent make it possible to process whole cell fermentation broths without blocking the column. Cu2+-iminodiacetic acid (IDA) DMAA cryogel has been used for the isolation and purification of excreted (His)6-tagged single chain (sc) Fv antibody fragments, (His)6-scFv, from E. coli cell culture. Bound protein was recovered with 0.2 M imidazole or with 20 mM EDTA and was practically cell-free. Chromatographic capture using Cu2+-IDA cryogel column was performed at flow rates of 300 and 600 cm/h, respectively and resulted in 84-96% recovery of (His)6-scFv fragments with a purification factor of 13-15. The DMAA cryogel adsorbent is mechanically stable, can withstand harsh cleaning-in-place procedure and is relatively inexpensive. Chromatographic isolation of proteins using cryogels allows efficient removal of cells and can be operated at a flow rate as high as 600 cm/h. This novel technique has proven to be a scalable process, does not require special equipment and can be a good alternative to expanded bed adsorption and other integrated isolation techniques.  相似文献   

3.
Immobilization of polysaccharides (yeast mannan and gum arabic) on the macroporous poly(glycidyl methacrylate) monodisperse microspheres coated with silica (SiO2)‐containing amino groups on the surface was used to prepare affinity sorbents for lectin purification. The efficiency of isolating mannose specific Pisum sativum lectin was demonstrated on sorbent with immobilized yeast mannan and that of galactose specific Glycine hispida lectin on sorbent with immobilized gum arabic. The microspheres with immobilized polysaccharides can be used for selecting an affinity sorbent for purification of other mannose‐ and galactose‐specific lectins. In contrast to yeast mannan, the gum arabic immobilized on the microspheres possesses much narrower specificity and is suitable for purification of only those galactose specific lectins which interact well with l ‐rhamnose or l ‐arabinose. The synthesized macroporous particles are capable of immobilizing 50 mg of polysaccharide per 1 g of the matrix, which is 10 times higher than the capacity of epoxy‐activated Sepharose 6B. That makes it possible to obtain the same lectin quantity using a column of 10 times smaller volume. Another advantage of novel affinity sorbents comparing corresponding Sepharose gels is the possibility of sorbent drying after use. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
Yang F  Lin Z  He X  Chen L  Zhang Y 《Journal of chromatography. A》2011,1218(51):9194-9201
A macroporous boronate affinity monolithic column was prepared and applied to specifically capture glycoproteins using metal-organic gels (MOGs) as a porogenic template. This newly explored application of MOGs has proven to be a more convenient method for the formation of macropores in contrast to traditional porogenic methods. The poly (3-acrylamidophenylboronic acid-co-ethylene dimethacrylate) monolithic columns were synthesized in stainless columns by in situ polymerization. To fabricate the macroporous formation with a uniformed open-channel network, the preparation conditions, such as reaction temperature, the concentration of the MOGs and the ratio of monomers were systematically investigated. The prepared macroporous monoliths were characterized by scanning electron microscope (SEM) and mercury intrusion porosimetry. Furthermore, horseradish peroxidase (HRP) and transferrin (TF) were chosen as test glycoproteins, and the chromatographic analysis demonstrated that the macroporous boronate affinity monoliths exhibited a higher selectivity and better dynamic binding capacity toward glycoproteins compared with non-glycoproteins. The resulted affinity monolithic column was successfully employed to specifically capture TF from a bovine serum sample.  相似文献   

5.
Using phage display technology, a 22-mer peptide was selected as a ligand with unique specificity for the murine monoclonal ST2146 antibody that recognizes the EGF repeats region of the human tumor-associated antigen tenascin-C. This peptide, synthesized in an 8-branched form to enhance its binding properties, is useful in replacing the native antigen in the affinity and immunoreactivity characterization of the ST2146 antibody and its biotinylated derivatives. Affinity resins, prepared by immobilizing the mimotope or its shorter 10-mer binding unit on a chromatographic support, were able to capture ST2146 directly from the hybridoma supernatant, with antibody recovery and host cell protein (HCP) reduction similar to or better than protein A sorbent, a purity degree exceeding 95%, and full recovery of antibody activity. The affinity constants of both peptides, as determined by frontal analysis of broad-zone elution affinity chromatography and BiaCore measurements, were very similar and included in a range suitable for affinity ligands. Column capacity, determined by applying a large excess of purified ST2146 to 1 mL of column bed volume, was close to 50 mg/mL for both resins. These matrices retain their ST2146 binding properties after various treatments, including sanitization, thus indicating very high stability in terms of ligand leakage and degradation. Moreover, the short form shows higher enzymatic stability, thus proving more suitable as ligand for ST2146 affinity purification.  相似文献   

6.
The worldwide production of whey increases by around 186 million tons each year and it is generally considered as a waste, even when several whey proteins have important economic relevance. For its valorization, inexpensive ligands and integrated chromatography methods need to be developed for specific and low‐cost protein purification. Here, we describe a novel affinity process with the dye Yellow HE‐4R immobilized on Sepharose for bovine lactoferrin purification. This approach based on a low‐cost ligand showed an efficient performance for the recovery and purification of bovine lactoferrin directly from whey, with a yield of 71% and a purification factor of 61.  相似文献   

7.
Angiotensin-converting enzyme from human lung was purified to apparent homogeneity using a five-step purification procedure consisting of ammonium sulfate precipitation, ion-exchange chromatography on DEAE Sephadex A-50, gel permeation on Sephadex G-200, chromatofocusing on a polybuffer exchange (PBE 94) column and high-performance liquid chromatographic gel permeation on a Bio-Sil TSK-250 column. This procedure gave an approximately 700-fold purification with a 20% yield compared to a 550-fold purification and a 1% yield with an affinity chromatography-based procedure. The 20-fold greater yield of the five-step procedure offers a major advantage for preparative use in the structural characterization of angiotensin-converting enzyme.  相似文献   

8.
The monodisperse, poly(glycidylmethacrylate-co-ethylenedimethacrylate) beads with macroporous in the range of 8.0-12.0 microm were prepared by a single-step swelling and polymerization method. The seed particles prepared by dispersion polymerization exhibited good absorption of the monomer phase. The pore size distribution of the beads was evaluated by gel permeation chromatography and mercury instrusion method. Based on this media, a hydrophobic interaction chromatographic (HIC) stationary phase for HPLC was synthesized by a new chemically modified method. The prepared resin has advantages for biopolymer separation, high column efficiency, low column backpressure, high protein mass recovery and good resolution for proteins. The dynamic protein loading capacity of the synthesized HIC packings was 40.0 mg/ml. Six proteins were fast separated in less than 8.0 min using the synthesized HIC stationary phase. The HIC resin was firstly used for the purification and simultaneous renaturation of recombinant human interferon-gamma (rhIFN-gamma) in the extract solution containing 7.0 mol/l guanidine hydrochloride with only one step. The purity and specific bioactivity of the purified of rhIFN-gamma was found more than 95% and 1.3 x 10(8) IU/mg, respectively.  相似文献   

9.
We describe microchip‐based phosphate‐affinity electrophoresis (μPAE) for separation of peptides aimed at determination of kinase activity. The μPAE exploits two recently published technologies: autonomous sample injection for PDMS microchips and a phosphate‐specific affinity ligand, Phos‐tag. We prepared a fluorescently labeled substrate peptide, specific to human c‐Src, and its phosphorylated form. We synthesized a Phos‐tag–poly(dimethylacrylamide) conjugate. The conjugate and the sample solutions were autonomously injected into a PDMS–glass hybrid microchip. The two solutions were contacted together in the microchannel. When the peptides were electrophoresed into the Phos‐tag–poly(dimethylacrylamide) region, the phosphorylated peptide was specifically trapped, and separated from the nonphosphorylated peptide in 10 s. The results were quantified by the areas of the fluorescence peaks. The calibration plot obtained with standard samples showed an excellent linearity and a LOD of 0.9% phosphorylated peptide among the total peptides. For c‐Src‐reacted samples, the results from the μPAE were in good agreement with those from matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry. The μPAE was also successful in the presence of inhibitors for c‐Src. The measured 50% inhibitory concentration values for staurosporine, PP2, and SU6656 were in good agreement with the literature values.  相似文献   

10.
Immobilized triazine dye affinity chromatography has been widely used for protein purification. In this paper, cibacron Blue F3G-A was immobilized,through a spacer arm, onto a rigid hydrophilic porous polymer by reacting an epoxy-group-containing poly(vinyl alcohol) with 6-aminohexyl-N'-Cibacron Blue F3G-A,which was obtained by reacting Cibacron Blue F3G-A with excess of 1,6-diaminohexane, in a pH 8.6 buffer. The epoxy-group-containing poly(vinyl alcohol) was prepared by hydrolysis of macroporous crosslinded poly(vinyl acetate),which was synthesized by suspension copolymerization of vinyl acetate and triallyl isocyanurate in the presence of butyl acetate and n-heptane as diluents. The cibacron Blue F3G-A-immobilized poly(vinyl alcohol)was packed in a stainless steel column (250×5 mm I. D.) and the chromatographic behaviors of several proteins (cytochrome c, lysozyme, bovine serum albumin, insulin, and lactate dehydrogenase) were determined.  相似文献   

11.
The purification of proteins by affinity chromatography is based on their highly specific interaction with an immobilized ligand followed by elution under conditions where their affinity towards the ligand is markedly reduced. Thus, a high-degree purification by a single chromatographic step is achieved. However, when several proteins in the crude mixture share affinity to a common immobilized ligand, they may not be resolved by affinity chromatography and subsequent "real" chromatographic purification steps may be required. It is shown that by using properly selected gradient elution conditions, the affinities of the various proteins towards the immobilized ligand may be gradually modulated and their separation may be achieved. This is exemplified by the isolation and separation of a group of Ca(2+)-activated proteins, Calmodulin, S100a and S100b, from bovine brain extract, using a melittin-Eupergit C affinity column which is developed with Ca(2+)-chelator gradients. As expected, separation of the three proteins into individual peaks, eluted in order of increasing affinity to the matrix, was obtained. Sigmoid selectivity curves calculated from the elution volumes under different elution conditions for each of the proteins were obtained, illustrating the chromatographic behaviour of the gradient affinity separation system.  相似文献   

12.
We developed novel magnetic nano-carriers around 180 nm in diameter for affinity purification. Prepared magnetic nano-carriers possessed uniform core/shell/shell nano-structure composed of 40 nm magnetite particles/poly(styrene-co-glycidyl methacrylate (GMA))/polyGMA, which was constructed by admicellar polymerization. By utilizing relatively large 40 nm magnetite particles with large magnetization, the magnetic nano-carriers could show good response to permanent magnet. Thanks to uniform polymer shell with high physical/chemical stability, the magnetic nano-carriers could disperse in a wide range of organic solvent without disruption of core/shell structure and could immobilize various kinds of drugs. We examined affinity purification using our prepared magnetic nano-carriers with anti-cancer agent methotrexate (MTX) as ligand. Our magnetic nano-carriers showed higher performance compared to commercially available magnetic beads in terms of purification efficiency of target including extent of non-specific binding protein.  相似文献   

13.
In the present work, isoelectric point (pl) separation of proteins by pH-gradient ion-exchange chromatography (IEC) on packed capillary columns is demonstrated. The development of a miniaturized flow-through pH probe for reliable pH monitoring of the column effluent, which was an important technical challenge for adapting this technique to capillary dimensions, was solved by designing a low microliter per minute flow rate housing to a commercially available micro pH probe. Highly linear outlet pH-gradients within the pH range 8.5-4.0 were obtained when applying simple inexpensive buffers consisting solely of piperazine, N-methylpiperazine and imidazole on 10 cm x 0.32 mm i.d. fused silica capillaries packed with anion-exchange poly(styrene divinylbenzene)-based macroporous materials, i.e. 10 microm Mono P from Amersham Biosciences and 10 microm PL-SAX from PolymerLabs. Furthermore, when using a pH-gradient from 6.8 to 4.3, both columns were able to baseline separate the A and B genetic variants of beta-lactoglobulin, which differ with two amino acid residues only, but the PL-SAX column provided almost a two-fold decrease in peak widths compared to the Mono P column. The influence of varying the buffer concentration, injection volume and column temperature on the peak widths and resolution of the beta-lactoglobulins was investigated, e.g. a 100 microl sample of dilute beta-lactoglobulins was injected directly on the column with practically no increase in peak width as compared to what obtained with conventional injection volumes. Finally, a pH-gradient from 6.8 to 4.3 was used to separate proteins in skimmed bovine milk on the PL-SAX column. The milk was simply diluted 1:10 (v/v) with water and filtrated before injection.  相似文献   

14.
This work reports the synthesis and characterization of poly(N-acryloyl-tris(hydroxymethyl)aminomethane-co-glycidyl methacrylate-co-N,N′-methylenebisacrylamide) [poly(NAT-GMA-BIS)] discs using different porogenic solvents. The macroporous polymer obtained with PEG 6000 as co-porogen showed the best porous properties of the series. End-point immobilization of heparin (Hep, as ligand) was then carried out on the products through reductive amination. Thus, the products were reacted with ethylenediamine (EDA) and hexamethylenediamine (HMDA) in order to introduce amine groups and to analyze the length of the spacer on the immobilization of heparin. Then, the highest value of amine groups [1.280 and 0.919 mmol amine/g dry support for poly(NAT-GMA-BIS)-EDA and poly(NAT-GMA-BIS)-HMDA, respectively] was obtained at 40 °C after 48 h of reaction. Finally, the amount of ligand coupled to discs was not influenced by the two length spacers assayed. The amount of Hep coupled on discs [591.50 and 489.90 μg Hep/g dry polymer for poly(NAT-GMA-BIS)-EDA-Hep and poly(NAT-GMA-BIS)-HMDA-Hep, respectively] was similar to that obtained using macroporous polymer beads reported by other authors. The supports yielded were used to assay the retention of antithrombin III (AT-III). The retention was greater for the EDA-containing product with a larger amount of heparin. These novel heparin-containing macroporous poly(NAT-GMA-BIS) discs could be used as potential affinity chromatography supports.  相似文献   

15.
The first step of bacterial or viral invasion is affinity and presumably multisite binding of bioparticles to an elastic matrix like a living tissue. We have demonstrated that model bioparticles such as inclusion bodies (spheres of about 1 microm in size) Escherichia coli cells (rods 1 x 3 microm), yeast cells (8 microm spheres), and synthetic microgel particles (0.4 microm spheres) are binding via different affinity interactions (IgG antibody-protein A, sugar-lectin, and metal ion-chelate) to a macroporous hydrogel (MH) matrix bearing appropriate ligands. The elastic deformation of the MH results in the detachment of affinity bound bioparticles. The particle detachment on elastic deformation is believed to be due to multipoint attachment of the particles to affinity matrix and the disturbance of the distance between affinity ligands when the matrix is deformed. No release of affinity bound protein occurred on elastic deformation. The efficiency of the particle release by the elastic deformation depends on the density of the ligands at the particle surface as well as on the elasticity of the matrix for relatively large particles. The release of the particles occurred irrespectively of whether the deformation was caused by external forces (mechanical deformation) or internal forces (the shrinkage of thermosensitive macroporous poly-N-isopropylacrylamide hydrogel on increase in temperature).  相似文献   

16.
This paper describes approaches to optimize the chromatographic performance for our recently developed LC-MS platform, extended range proteomic analysis (ERPA), for comprehensive protein characterization at the ultratrace level. Large digested peptide fragments up to 10 kDa (e.g., from lysyl endopeptidase digestion) with or without modifications were well separated with high resolution using narrow bore (20 and 50 microm I.D.) poly(styrene-divinylbenzene) (PS-DVB) monolithic columns constructed by in situ solution polymerization. Importantly, the macroporous structure of the monolithic columns facilitated mass transport of large peptides with improved recovery relative to small pore size reversed-phase packings. High sequence coverage (>95%), including identification of phosphorylated and glycosylated particles was achieved for beta-casein and epidermal growth factor receptor (EGFR) at the 4 and 20 fmol levels per injection, respectively, using the 20 microm I.D. PS-DVB monolithic column. For peptides with greater ionization efficiency, the detection limit could be lowered to approximately 400 zmol. Typically, the separation system produced a peak capacity of approximately 200 for a 10 cm column. This paper demonstrates that narrow-bore monolithic columns are suitable for high sensitivity and high-resolution separation of large peptide fragments by LC-MS analysis.  相似文献   

17.
A new type of supermacroporous, monolithic, cryogel affinity adsorbent was developed, allowing the specific capture of urokinase from conditioned media of human fibrosarcoma cell line HT1080. The affinity adsorbent was designed with the objective of using it as a capture column in an integrated perfusion/protein separation bioreactor setup. A comparative study between the utility of this novel cryogel based matrix and the conventional Sepharose based affinity matrix for the continuous capture of urokinase in an integrated bioreactor system was performed. Cu(II)-ion was coupled to epoxy activated polyacrylamide cryogel and Sepharose using iminodiacetic acid (IDA) as the chelating ligand. About 27-fold purification of urokinase from the conditioned culture media was achieved with Cu(II)-IDA-polyacrylamide cryogel column giving specific activity of about 814 Plough units (PU)/mg protein and enzyme yields of about 80%. High yields (95%) were obtained with Cu(II)-IDA-Sepharose column by virtue of its high binding capacity. However, the adsorbent showed lower selectivity as compared to cryogel matrix giving specific activity of 161 PU/mg protein and purification factor of 5.3. The high porosity, selectivity and reasonably good binding capacity of Cu(II)-IDA-polyacrylamide cryogel column make it a promising option for use as a protein capture column in integrated perfusion/separation processes. The urokinase peak pool from Cu(II)-IDA-polyacrylamide cryogel column could be further resolved into separate fractions for high and low molecular weight forms of urokinase by gel filtration chromatography on Sephacryl S-200. The selectivity of the cryogel based IMAC matrix for urokinase was found to be higher as compared to that of Cu(II)-IDA-Sepharose column.  相似文献   

18.
Penicillin acylase (PA, EC 3.5.1.11) is used as a raw material in the production of semi-synthetic penicillins. Although there are many methods for PA purification, affinity chromatography is advantageous as it provides efficient one step purification. In this study, poly(2-hydroxyethyl methacrylate) based cryogel column containing hydrophobic N-methacryloyl-L-tryptophan (MATrp) functional monomer as a ligand was prepared. Interaction of MATrp with amino acids in PA structure is the basis of hydrophobic interaction chromatography in this study. PHEMA and PHEMATrp cryogel columns were characterized by surface area measurements, infrared spectroscopy, swelling tests, elemental analysis and scanning electron microscopy (SEM). Initial PA concentration, pH, effect of temperature, amount of ligand, flow rate, ionic strength and time on PA adsorption on PHEMATrp cryogel were investigated. Optimum pH was determined as 5.0 for PA adsorption and maximum adsorption capacity was obtained as 6.40 mg/g. It was observed that adsorption capacity increased with the increasing of temperature. Also, PA adsorption increased up to 0.25 M salt concentration and decreased in higher salt concentrations. Data obtained in this affinity system suggests that hydrophobic interactions are dominant. In the last stage of the study, PA was purified from Penicillium chrysogenum with 76.3% yield and 332.3 purification factor.  相似文献   

19.
We present a novel procedure for affinity partitioning of recombinant proteins fused to the choline-binding module C-LytA in aqueous two-phase systems containing poly(ethylene glycol) (PEG). Proteins tagged with the C-LytA module and exposed to the two-phase systems are quantitatively localized in the PEG-rich phase, whereas subsequent addition of the natural ligand choline specifically shifts their localization to the PEG-poor phase by displacement of the polymer from the binding sites. The described procedure is simple, scalable and reproducible, and has been successfully applied to the purification of four diverse proteins, resulting in high yields and purity.  相似文献   

20.
The influenza virus surface glycoprotein antigen neuraminidase (NA) is a crucial viral enzyme with many potential medical applications; therefore, the development of efficient upstream and downstream processing strategy for the expression and purification of NA is of high importance. In the present work the NA gene from the H1N1 influenza virus strain A/Beijing/262/95 was cloned from viral RNA and expressed in expresSF+ insect cells using the baculovirus expression vector system (BVES). A limited affinity-ligand library was synthesized and evaluated for its ability to bind and purify the recombinant H1N1 neuraminidase. Affinity-ligand design was based on mimicking the interactions of the lock-and-key (LAK) motif (Phe-Gly-Gln), a common structural moiety found in the subunit interface of glutathione S-transferase I (GST I), and plays an important structural role in subunit-subunit recognition. Solid-phase combinatorial chemistry was used to synthesize 13 variants of the lock-and-key lead ligand (Phe-Trz-X, where X was selected alpha-amino acid) using the 1,3,5-triazine moiety (Trz) as the scaffold for assembly. One immobilized ligand, bearing phenylalanine and isoleucine linked on the chlorotriazine ring (Phe-Trz-Ile), displayed high affinity for NA. Absorption equilibrium and molecular modeling studies were carried out to provide a detailed picture of Phe-Trz-Ile interaction with NA. This LAK-mimetic affinity adsorbent was exploited in the development of a facile purification protocol for NA, which led to 335-fold purification in a single-step. The present purification procedure is the most efficient reported so far for recombinant NA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号