首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This study presents matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) as a powerful tool to analyze and characterize oligonucleotides covalently linked to a solid support during their synthesis. The analysis of the fragment ions generated either in negative or positive mode allows direct and easy access to the nucleotide sequence and identification of the internucleosidic linkage. The mechanisms of the fragmentation of the solid-supported oligonucleotides induced by MALDI-TOFMS are discussed. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

2.
The use of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) for the quantitative determination of phospholipid (PL) molecular species has been problematic, due primarily to the formation of multiple signals (corresponding to the molecular ion and other adducts) for some classes of PL. For example, analysis of phosphatidylcholine (PC) yielded signals that corresponded to protonated and sodiated molecules in the MALDI spectrum. The resulting spectral overlap among various molecular species (e.g. [PC(16:0/18:2) + Na] and [PC(18:2/18:3)]) made it impossible to ascertain their relative amounts using this technique. Other spectral ambiguities existed among different structural isomers, such as PC(18:1/18:1) and PC(18:0/18:2). We determined that molecular species could be resolved by MALDI-TOFMS by first removing the polar head (e.g. phosphocholine) from the phospholipid to effect production of only the sodiated molecules of the corresponding diacylglycerols (DAGs). Analysis of the resulting spectrum allowed unequivocal determination of the molecular species profile of PC from potato tuber and soybean. Estimation of fatty acid composition based on the molecular species determined by MALDI-TOFMS analysis agreed with that from GC-FID analysis. Post-source decay (PSD) was used to resolve standard isomers of PC (e.g. 18:1/18:1 vs. 18:0/18:2). Our results indicated that PSD is a useful approach for resolving structural isomers of PL molecular species.  相似文献   

3.
A quick and effective sample preparation is demonstrated for matrix-assisted laser desorption/ionization (MALDI) analysis of nonpolar polymers. Polyisoprene, polystyrene, and polybutadiene polymers were investigated by using as matrix a 2,5-dihydroxybenzoic acid and silver nitrate combination. Silver cationized oligomers produce useful spectra that can be signal averaged to characterize polymer distributions extending up to 6000 u by using a 3-T Fourier transform mass spectrometer. Because an electrostatic ion deceleration protocol was used to extend the mass range, trapping discrimination is shown to exist for molecular weight distributions broader than about 2500 u. However, an integral procedure can be used to reconstruct the true polymer profiles through co-addition of signal transients obtained by using various gated deceleration times. For polymers with narrower mass distributions, silver cationization along with signal averaging provides rapid and accurate polymer characterization for nonpolar polymer systems by using standard MALDI Fourier transform mass spectrometry instrumentation.  相似文献   

4.
A fast method to detect and sequence photomodified oligodeoxynucleotides (ODNs) by exonuclease digestion and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is reported. Upon treatment of modified ODNs with both phosphodiesterase I and phosphodiesterase II, the digestion stops at the sites of photomodification. Post-source decay (PSD) of MALDI-produced ions from two enzymatic digestion end products distinguishes isomers such as 5'-d(T[cis-syn]TAAGC) and 5'-d(CGAAT[cis-syn]T), which have symmetrical or identical compositions at the 3' and 5' ends, respectively. Studies have also been done to follow the kinetics for enzyme degradation of photomodified ODNs. The calculated rate constants from a mathematical treatment of the time-dependent MALDI data clearly show that the enzymatic digestion rate slows as the enzyme approaches the modified site.  相似文献   

5.
Matrix-assisted laser desorption ionization is a recently developed new ionization technique which enables macromolecular compounds to be investigated by mass spectrometry. The general features of the technique are described, they have so far mainly been worked out for biopolymers such as proteins. Fast and precise molecular weight determination is possible up to 400,000 Dalton. First examples described in this paper indicate that the technique also holds great promise for the investigation of synthetic polymers.  相似文献   

6.
Matrix-assisted laser desorption/ionization mass spectrometry is an analytical technique enabling the mass analysis of biopolymers with masses up to at least 300,000 Da. Incorporation of analyte in a matrix consisting of small highly absorbing organic molecules and excitation with short pulses of intense laser light enables the production of intact molecule ions to be analyzed in a time-of-flight mass spectrometer. Mass accuracies of up to 0.01% can be achieved from sample amounts of 1 pmol or less. Proteins, glycoproteins, oligonucleotides and oligosaccharides have been analyzed. The short analysis time of several minutes makes the method well suited for combination with other biochemical methods.  相似文献   

7.
Transition-metal acetylacetonate complexes of the form Metal(acac)(2), where Metal = Fe(II), Co(II), Ni(II), Cu(II), and Zn(II), and Metal(acac)(3), where Metal = V(III), Cr(III), Mn(III), Fe(III), and Co(III), were investigated by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The data was acquired using the aprotic, electron transfer matrix, 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene]malononitrile (DCTB), and the observation of positive radical ions is shown clearly to depend on the metal element and the oxidation state it occupies. The ionization energy of DCTB was calculated to be 8.08 eV by density functional theory methods, which is notably lower than the experimental value, but within the range of other computational values. This value is very close to those of the analytes, so the existing electron transfer mechanism which is based on the ionization energies of the matrix and analyte, cannot be used predictively. Similarly, the data neither proves nor disproves the validity of the existing electron transfer ionization mechanism, with respect to metal coordination complexes without strong chromophores. In this case, periodic trends may be more useful in explaining the observed species and the prediction of species from sets of similar complexes. The addition of a sodium salt benefits the MALDI-TOFMS characterization of certain compounds studied, but the benefit of the addition of ammonium or silver salts is negligible.  相似文献   

8.
Laser desorption mass spectrometry with liquid matrix-assistance has been used to study a series of selected porphyrins and metalloporphyrins. This work presents the results of using a liquid matrix with fibrous material as the substrate for liquid matrix assisted laser desorption of porphyrins and metalloporphyrins. The liquid matrices used for porphyrin studies were o-nitrophenyl octyl ether (NPOE) and 15-crown-5. The use of a liquid matrix with soft laser ionization enhances molecular ion formation. We also have investigated the use of NPOE as a liquid matrix for identifying mixtures of up to six porphyrins in a single shot spectrum without prior separation. The (M + H)+ peak of each metalloporphyrin component in the mixture is clearly indicated in the spectra and no obvious interference effects were observed.  相似文献   

9.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to detect an immune complex formed between beta-lactoglobulin and polyclonal anti-beta-lactoglobulin antibody in the gas phase. The most important experimental parameters to detect such a specific antibody-antigen complex by MALDI were the use of solutions at near-neutral pH and of sinapinic acid matrix prepared by the dried-droplet method. Under such conditions, predominantly one but also two molecules of antigen protein were complexed by the antibody. Specific formation of the antibody-antigen complex was confirmed by performing competitive reactions. Addition of antibody to a 1:1 mixture of beta-lactoglobulin and one control protein resulted not only in the appearance of the expected antibody-antigen complex, but also in a strong decrease in the free beta-lactoglobulin signal, while the abundance of the control protein was not influenced.  相似文献   

10.
Metal labelling of peptides and proteins using high-affinity metal-chelating compounds has found widespread applications in the medical and bioanalytical fields. In the present study we investigated the analysis of peptides derivatized either with cysteine- or amino group-directed metal-bound DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) chelators in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The metal complexes of DOTA were shown to be stable under MALDI-MS conditions. The introduction of the metal label led in a number of cases to significantly increased signal-to-noise (S/N) values and thus improved sensitivity of the labelled peptides compared to their unlabelled counterparts, especially for multiply labelled peptides. The presence of the labels did alter the tandem mass spectrometric (MS/MS) behaviour, namely the formation of sequence specific a-, b- and y-ion series, in dependence of the position of the label within the peptide sequence. For cysteine-derivatized peptides several label-specific reporter ions and characteristic immonium ions could be identified. Amino-directed labelling led only to the formation of characteristic immonium ions in ε-amino groups of lysine, whereas N-terminal labelling in some cases led to the formation of a(1)- and b(1)-ions. The results clearly show that MALDI-MS is suitable for the analysis of metal-labelled peptides, which was also confirmed in liquid chromatography (LC)/MALDI-based identification of proteins in a model protein mixture labelled with Cys-reactive DOTA. Here, in comparison to a run with alkylated cysteines, more than 50% more cysteine-containing peptides were identified.  相似文献   

11.
12.
Daniel JM  Ehala S  Friess SD  Zenobi R 《The Analyst》2004,129(7):574-578
A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. alpha-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA.  相似文献   

13.
Oxidative damage to proteins can occur under physiological conditions through the action of reactive oxygen species, including those containing nitrogen such as peroxynitrite (ONO2-). Peroxynitrite has been shown in vitro to target tyrosine residues in proteins through free radical addition to produce 3-nitrotyrosine. In this work, we show that mass spectral patterns associated with 3-nitrotyrosine containing peptides allow identification of peptides containing this modification. Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry was used to characterize a synthetic peptide AAFGY(m-NO2)AR and several peptides containing 3-nitrotyrosine derived from bovine serum albumin treated with tetranitromethane. A unique series of ions were found for these peptides in addition to the mass shift of +45 Da corresponding to the addition of the nitro group. Specifically, two additional ions were observed at roughly equal abundance that correspond to the loss of one and two oxygens, and at lower abundances, two ions are seen that suggest the formation of hydroxylamine and amine derivatives. These latter four components appear to originate by laser-induced photochemical decomposition. MALDI-MS analysis of the synthetic peptide containing 3-nitrotyrosine revealed this same pattern. Post-source decay (PSD) MALDI-time-of-flight (TOF) and collisional activation using a prototype MALDI quadrupole TOF yielded extensive fragmentation that allowed site-specific identification of 3-nitrotyrosine. Conversion of peptides containing 3-nitrotyrosine to 3-aminotyrosine with Na2S2O4 yielded a single molecular ion by MALDI with an abundant sidechain loss under PSD conditions. These observations suggest that MALDI can provide a selective method for the analysis and characterization of 3-nitrotyrosine-containing peptides.  相似文献   

14.
A study of the collision-induced dissociation post-source decay (PSD) spectra of free oligosaccharides is presented. These spectra, when obtained with helium as collision gas, show (1,5)X fragments containing the reducing end sugar. The presence of these fragments permits Y ions and, consequently, B and C peaks to be identified. This is a common behaviour from which it has been possible to delineate a general method for the easy assignment of the peaks in PSD spectra of underivatized neutral sugars, allowing the sequence of a real unknown to be obtained.  相似文献   

15.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and laser desorption/ionization (LDI-)TOFMS have been used to characterize Suwannee River humic substances, obtained from the International Humic Substances Society (IHSS), and Armadale soil fulvic acid (ASFA). An array of MALDI matrices were tested for use with humic substances, including alpha-cyano-4-hydroxycinammic acid (CHCA), 2-(4-hydroxyphenylazo)benzoic acid (HABA), 2,5-dihydroxybenzoic acid (DHBA), sinapinic acid, dithranol and norharmane. DHBA yielded the best results, exhibiting superior ionization efficiency, low noise, broad applicability to the analytes of interest, and most importantly producing an abundance of high mass ions, the highest observed being m/z 1848. A number of sample preparation modes were investigated; the overlayer method improved sample/matrix homogeneity and hence shot-to-shot reproducibility. The choice of the matrix, mass ratio of analyte to matrix, and the sample preparation protocol, were found to be the most critical factors governing the quality of the mass spectra. Matrix suppression was greatly enhanced by ensuring good mixing of matrix and analyte in the solid phase, proper optimization of the matrix/analyte ratio, and optimizing delayed extraction to ensure complete matrix-analyte reaction in the plume before ions are moved to the flight tube. A number of common features, in particular specific ions which could not be attributed to the matrices or to contaminants, were present in the spectra of all the humic substances, regardless of origin or operational definition. Additionally, a prominent repeating pattern of peaks separated by 55, 114 and 169 Da was clearly observed in both LDI and MALDI, suggesting that the humic compounds studied here may have quasi-polymeric or oligomeric features.  相似文献   

16.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has successfully been used to differentiate pseudo-enantiomeric (isotopically labelled) amino acids by using cyclodextrin as complexing host. By using different pseudo-enantiomeric mixtures (i.e. R(Dn) + S; and R + S(Dn)), it has been demonstrated that the preference of cyclodextrin for S-enantiomers is not due to the size differences caused by the hydrogen/deuterium substitution. It is postulated that this method can be extended to differentiate enantiomers (and determine enantiomeric excess) by using a pair of enantiomeric hosts, as demonstrated previously using other ionization techniques, but with much higher sensitivity.  相似文献   

17.
The negative ion mode of field desorption mass spectrometry is matrix dependent. The matrix is used to facilitate the desolvation of ions at field strengths below the onset of field induced electron detachment. The role of the matrix in the desolvation mechanism for negative ions is briefly described and the main properties of a matrix solution, such as viscosity, solubility for complex salts and acids, and adhesion to the emitter surface, on the ion formation are discussed. The application of matrix mixtures with strong adhesion to the emitter surface even at elevated temperatures and high field strengths are considered to be important for the further improvement of this ionization method.  相似文献   

18.
We report the direct laser desorption/ionization (LDI) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis of four inorganic coordination complexes: monometallic [Ir(dpp)(2)Cl(2)](PF(6)), homonuclear trimetallic ([(bpy)(2)Ru(dpp)](2)RuCl(2))- (PF(6))(4), and heteronuclear [(tpy)Ru(tpp)Ru(tpp)RhCl(3)](PF(6))(4) and ([(bpy)(2)Ru(dpp)](2)IrCl(2))(PF(6))(5) (dpp = 2,3-bis-(2'-pyridyl)pyrazine, bpy = 2,2'-bipyridine, tpy = 2,2',6',2"-terpyradine, tpp = 2,3,5,6,-tetrakis-(2'-pyridyl)pyrazine). Spectral intensities and fragmentation patterns are compared and evaluated for instrument parameters, matrix selection, and matrix-to-analyte ratio. Direct LDI and MALDI mass spectra of the monometallic complex showed the same ion peaks and differed only in the relative peak intensities. Direct LDI of the trimetallic complexes produced only low-mass fragments containing one metal at most. MALDI spectra of the trimetallic complexes exhibited little fragmentation in the high-mass region (>1500 Da) and less fragmentation in the low-mass region compared to direct LDI. Significant fragments of the molecules were detected and identified, including ligand fragments, intermediate-mass fragments such as [Ru(tpy)](+), and molecular ions with varying degrees of PF(6)(-) loss ([M - n(PF(6))](+), where n = 1-3). A correlation exists between the solution-phase electrochemistry and the observed [M - n(PF(6))](+) series of peaks for the trimetallic complexes. Proper matrix selection for MALDI analysis was vital, as was an appropriate matrix-to-analyte ratio. The results demonstrate the applicability of MALDI-TOFMS for the structural characterization of labile inorganic coordination complexes.  相似文献   

19.
The intact fungal spores of several strains of four Aspergillus species, Aspergillus flavus, A. oryzae, A. parasiticus, and A. sojae, were directly analyzed by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Very simple MALDI mass spectra are obtained by directly mixing spores with a matrix such as alpha-cyano-4-hydroxycinnamic acid or sinapinic acid. The mass spectra are obtained from the ablation of cell walls of spores owing to the acidity of the matrix solution. The MALDI results show that aflatoxigenic strains and non-aflatoxigenic strains have different mass peak profiles. Furthermore, the MALDI results of non-aflatoxigenic A. flavus and A. parasiticus spores resemble those of the closely related A. oryzae and A. sojae spores, respectively.  相似文献   

20.
A protocol for the preparation of polymeric samples for time-of-flight matrix-assisted laser desorption ionization mass spectrometry (TOF-MALDI-MS) analysis was developed. Dithranol was identified as a good matrix for polystyrene (PS), and the addition of silver for cationization of molecules was determined to be necessary. Based on this preparative method, low molecular weight samples of other polymers [polyisoprene, polybutadiene, poly(ethylene oxide), poly(methyl methacrylate), and polydimethylsiloxane] were analyzed with molecular weights up to 49 ku. The effects of laser intensity were determined to influence the molecular weight distribution of intact oligomers, most significantly for low molecular weight polymers. Linear and reflectron modes of analysis were evaluated; better signal intensity and resolution were obtained in the reflectron mode. The TOF-MALDI-MS measurements are compared with time-of-flight secondary ion mass spectrometry (TOF-SIMS) and gel permeation chromatography (GPC) for the same polymers. The M n values calculated by TOF-MALDI-MS consistently are higher than values calculated by TOF-SIMS for all classes of polymers with molecular weights up to 8 ku. The molecular weights of the PS calculated from TOF-MALDI-MS are in good agreement with GPC (±10%). The composition of the terminal group on a polymer chain may affect the ion yields. The ion yields of intact oligomers were evaluated as a function of end group composition for both TOF-MALDI-MS and TOF-SIMS. The slight disparity of results between TOF-SIMS and TOF-MALDI-MS for the perfluoroalkyl-terminated PS suggests that the oligomers are desorbed preferentially from the surface in the TOF-SIMS analysis, rather than having an increased ionization probability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号