首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Summary An on-line, solid-phase extraction gas chromatography atomic-emission detection (SPE-GC-AED) system has been set up using an on-column interface to transfer 100 l of desorbing solvent to the GC part of the system. Analytical characteristics such as recovery, precision and linearity of calibration plots were comparable with those of the off-line combination of SPE-GC-AED using organophosphorus pesticides as test compounds. The fully on-line set-up causes a marked improvement in detection because of the quantitative transfer of the analytes from the SPE module to the GC: detection limits are as low as 5–20 ng l–1 for the analysis of 10 ml raw and spiked surface water samples using the phosphorus channel. Detection levels can be further enhanced by processing up to 100 ml samples. The integrated analytical system is robust. The potential of the on-line set up has been demonstrated for the analysis of surface water and waste water.  相似文献   

2.
A rapid, sensitive and efficient liquid phase microextraction (LPME) method was developed to determine trace concentrations of some organophosphorus pesticides in water samples. This method combines liquid phase microextraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little organic solvent consumption. It involves exposing a floated drop of an organic solvent on the surface of aqueous solution in a sealed vial. Experimental parameters which control the performance of LPME such as type of organic solvent, organic solvent and sample volumes, sample stirring rate, sample solution temperature, salt addition and exposure time were investigated and optimized. Finally, the enrichment factor, dynamic linear range (DLR), limit of detection (LOD) and precision of the method were evaluated by the water samples spiked with organophosphorus pesticides. Using optimum extraction conditions, very low detection limits (0.01-0.04 μg L−1) and good linearities (0.9983 < r2 < 0.9999) were achieved. The LPME was performed for determination of organophosphorus pesticides in different types of natural water samples and acceptable recoveries (96-104%) and precisions (3.5 < R.S.D.% < 8.9) were obtained. The results suggested that the newly proposed LPME method is a rapid, accurate and effective sample preparation method and could be successfully applied for extraction and determination of organophosphorus pesticides in water samples.  相似文献   

3.
A recently synthesized polyaniline (PANI) has been used and evaluated as a sorbent for solid-phase extraction of a variety of polar pesticides and some of their degradation products from water samples. Several classes of pesticides including phenoxy acids, triazines, ureas, oxime carbamates and carbamates were selected for this study. The determination of these pesticides was carried out using cyclodextrin modified micellar electrokinetic chromatography equipped with diode array detection. The recovery results using PANI were compared with those obtained by C18, Isolute ENV+, Oasis HLB and LiChrolut EN. Effect of humic acid, as a major interference, on extraction recovery was also studied. The performance of the method was evaluated by analysis of tap and river water. The RSD of method was between 6 and 14% (n=3) and detection limits were in the range of 0.01–0.5 g L–1 using 350-mL water samples.  相似文献   

4.
A simple and rapid solid-phase microextraction (SPME) method is presented based on activated charcoal–PVC fiber for determination of some organophosphorus pesticides from aqueous samples in direct mode SPME. After optimization of the experimental variables affecting SPME of the target compounds from aqueous solutions, the proposed method was applied to determine pesticides in fruit juice. The analytes in this procedure were preconcentrated for 15 min on the SPME fiber and subsequently desorbed by heating the fiber at 200 °C for 5 min in the GC injection port. Separation was on a capillary column GC followed by flame ionization detection. Recoveries of the pesticides studied in aqueous samples ranged 42%–63% and repeatability for all analytes was < 9% for a single fiber. Fiber-to-fiber reproducibility was < 18%.  相似文献   

5.
A novel, simple, and inexpensive approach to sorptive extraction, which we call solvent in silicone tube extraction (SiSTEx), was applied to pesticide residue analysis and its effectiveness and efficiency were evaluated. In SiSTEx, which is a form of open tubular sorptive extraction, a piece of silicone tubing (4 cm long, 1.47 mm ID, 1.96 mm OD in this study) is attached to the cap of a 20 mL glass vial that contains the aqueous sample. The tubing is plugged at the end dangling in the sample solution, and MeCN (e.g., 40 microL) added by syringe to the inner tube volume through a septum in the cap. A stir-bar is used to mix the sample for a certain time (e.g., 60 min), which allows chemicals to partition into the tubing where they diffuse across the silicone and partition into the MeCN. The final MeCN extract is then analyzed for the concentrated analytes. In this study, the SiSTEx approach was evaluated for the analysis of organophosphorus (OP) and organochlorine (OC) pesticides in fruits and vegetables using GC/pulsed flame photometric (PFPD) and halogen specific (XSD) detectors for analysis. The produced samples were initially extracted by a rapid MeCN procedure, and 5 mL of the initial extract was diluted four-fold with water to undergo sorptive extraction for 60 min. The final extract was analyzed by GC/PFPD + XSD for 14 OP and 22 OC pesticides. This simple approach was able to detect 26 of the 36 pesticides at 10 ng/g or less original equivalent sample concentration with average reproducibility of 11% RSD. For those 26 pesticides, a 44-fold lower detection limit on average was achieved in matrix extracts using SiSTEx despite the four-fold dilution with water.  相似文献   

6.
《Analytical letters》2012,45(14):1971-1979
In this paper, bamboo charcoal was successfully developed for the solid-phase extraction adsorbent for the determination of six organophosphorus pesticides in water samples. After the bamboo charcoal was pretreated and packed in the solid-phase extraction cartridge, the organophosphorus pesticides in water samples were carried out the solid-phase extraction. To establish a perfect solid-phase extraction procedure, the experimental conditions including the eluent, eluent volume, pH of the sample, flow rate of the sample, and loading volume of the sample were all investigated. When 100 mL water samples in the pH range of 6–7 were loaded with the flow rate of 2.5 mL · min?1 and then eluted with 10 mL acetonitrile, the proposed extraction method was validated by the recovery, correlation coefficient (R2), repeatability (RSD, n = 7) and LODs, which were 69.6–93.4%, 0.9982–0.9998, 2.9–5.6%, and 0.08–1.04 µg · L?1, respectively. Furthermore, the analysis of the tap, snow, and river water samples demonstrated the feasibility of the proposed SPE method for real water samples. Based on the aforementioned factors, it could be concluded that bamboo charcoal was a good solid-phase extraction adsorbent, and this proposed solid-phase extraction method was suitable for the effective enrichment and determination of the organophosphorus pesticides in water samples.  相似文献   

7.
A dispersive liquid-liquid microextraction (DLLME) procedure coupled with GC/MS detection is described for preconcentration and determination of some organophosphorus and azole group pesticides from water samples. Experimental conditions affecting the DLLME procedure were optimized by means of an experimental design. A mixture of 60 microL chlorobenzene (extraction solvent) and 750 microL acetonitrile (disperser solvent), 3.5 min extraction time, and 7.5 mL aqueous sample volume were chosen for the best recovery by DLLME. The linear range was 1.6-32 microg/L. The LOD ranged from 48.8 to 68.7 ng/L. The RSD values for organophosphorus and azole group pesticides at spiking levels of 3, 6, and 9 microg/L in water samples were in the range of 1.1-12.8%. The applicability and accuracy of the developed method were determined by analysis of spiked water samples, and the recoveries of the analyzed pesticides from artesian, stream, and tap waters at spiking levels of 3, 6, and 9 microg/L were 89.3-105.6, 89.5-103.0, and 92.0-111.3%, respectively.  相似文献   

8.
For the first time a dispersive liquid–liquid microextraction method on the basis of an extraction solvent lighter than water was presented in this study. Three organophosphorus pesticides (OPPs) were selected as model compounds and the proposed method was carried out for their preconcentration from water samples. In this extraction method, a mixture of cyclohexane (extraction solvent) and acetone (disperser) is rapidly injected into the aqueous sample in a special vessel (see experimental section) by syringe. Thereby, a cloudy solution is formed. In this step, the OPPs are extracted into the fine droplets of cyclohexane dispersed into aqueous phase. After centrifuging the fine droplets of cyclohexane are collected on the upper of the extraction vessel. The upper phase (0.40 μL) is injected into the gas chromatograph (GC) for separation. Analytes were detected by a flame ionization detector (FID) (for high concentrations) or MS (for low concentrations). Some important parameters, such as the kind of extraction and dispersive solvents and volume of them, extraction time, temperature, and salt amount were investigated. Under the optimum conditions, the enrichment factors (EFs) ranged from 100 to 150 and extraction recoveries varied between 68 and 105%, both of which are relatively high over those of published methods. The linear ranges were wide (10–100 000 μg/L for GC‐FID and 0.01–1 μg/L for GC‐MS) and LODs were low (3–4 μg/L for GC‐FID and 0.003 μg/L for GC‐MS). The RSDs for 100.0 μg/L of each OPP in water were in the range of 5.3–7.8% (n = 5).  相似文献   

9.
Solid‐phase extraction coupled with dispersive liquid–liquid microextraction was developed as an ultra‐preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion‐methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid‐phase extraction coupled with dispersive liquid–liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid‐phase extraction coupled with dispersive liquid–liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9–6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples.  相似文献   

10.
For the first time, the low‐density solvent‐based vortex‐assisted surfactant‐enhanced emulsification liquid–liquid microextraction, followed by GC‐flame photometric detection has been developed for the determination of eight organophosphorus pesticides in aqueous samples. A small volume of organic extraction solvent (toluene) was dispersed into the aqueous samples by the assistance of surfactant and vortex agitator. The extraction was performed in a special disposable polyethylene pipette, allowing using the reagents with lower density than water as extraction solvents. The influence parameters were systemically investigated and optimized: toluene (30 μL) and Triton X‐100 (0.2 mmol/L) were used as the extraction solvent and the surfactant, respectively, and the extraction was performed for 1 min under room temperature without adding sodium chloride. Under the optimum conditions, the validation parameters such as the RSD (n = 6; 2.1–11.3%), LOD (0.005 and 0.05 μg/L), and linear range (0.1–50.0 μg/L with correlation coefficients (0.9958–0.9992) showed the method was satisfying. The proposed method has been successfully applied to the determination of the organophosphorus pesticides in real samples with recoveries between 82.8 and 100.2%.  相似文献   

11.
Picó  Y.  Vreuls  J. J.  Ghijsen  R. T.  Brinkman  U. A. Th. 《Chromatographia》1994,38(7-8):461-469
Summary A small cartridge containing a drying agent is inserted between a solid phase extraction (SPE) column and a gas chromatograph (GC) to enable the introduction of water-free desorption solvent into the GC in on-line liquid chromatography (LC)-type enrichment of trace-level analytes from water samples. Some characteristics of the drying agents, such as their capacity to retain water and their re-usability after heating, have been tested. Possible interactions of the drying agent with the analytes, e.g., irreversible adsorption or catalyzed degradation, have been checked for a wide range of alkanes, alkylbenzenes chlorobenzenes, chlorophenols and phthalate esters. Using the on-line SPE-GC system with flame ionization detection (FID) and spiked samples containing different levels of the test compounds, the repeatability was shown to be satisfactory (6–17%). For 10 mL samples, the detection limits were lower than 0.1 g/L. The on-line SPE-GC-FID system here presented can be used for the repeated analysis of water samples without exchange of the dyring cartridge. The technique is applied to the analysis of tap water.  相似文献   

12.
T. A. Berger 《Chromatographia》1995,41(7-8):471-484
Summary Nearly 100 pesticides were eluted with good peak shapes from silica columns using methanol/carbon dioxide mobile phases. The pesticides included organophosphorus, organochlorine, phenylurea, sulfonylurea, triazine, carbamate and phenoxyacid pesticides, demonstrating the wide applicability of SFC to pesticide analysis. A subset of 31 pesticides were on-line extracted from large water samples, typically 10 to 20 ml, but up to 100 ml. The extracts were separated on a 1.6 meter long column packed with 5 μm particles, then detected simultaneously with a photodiode array UV detector plus an electron capture (ECD) and a nitrogen-phosphorus (NPD) detector. Recovery, reproducibility, linearity, response factors and detection limits were determined. Detection limits from a 5 ml water sample were in the range of 100 to 500 parts per trillion (1/1012). Larger samples appear capable of lowering these limits to below 10 ppt.  相似文献   

13.
A new, simple and cost-effective method based on the use of multi-walled carbon nanotubes (MWCNTs) as solid-phase extraction stationary phases is proposed for the determination of a group of seven organophosphorus pesticides (i.e. ethoprophos, diazinon, chlorpyriphos-methyl, fenitrothion, malathion, chlorpyriphos and phosmet) and one thiadiazine (buprofezin) in different kinds of soil samples (forestal, ornamental and agricultural) using gas chromatography with nitrogen phosphorus detection. Soils were first ultrasound extracted with 10 mL 1:1 methanol/acetonitrile (v/v) and the evaporated extract redissolved in 20 mL water (pH 6.0) was passed through 100 mg of MWCNTs of 10-15 nm o.d., 2-6 nm i.d. and 0.1-10 μm length. Elution was carried out with 20 mL dichloromethane. The method was validated in terms of linearity, precision, recovery, accuracy and selectivity. Matrix-matched calibration was carried out for each type of soil since statistical differences between the calibration curves constructed in pure solvent and in the reconstituted soil extract were found for most of the pesticides under study. Recovery values of spiked samples ranged between 54 and 91% for the three types of soils (limits of detection (LODs) between 2.97 and 9.49 ng g−1), except for chlorpyrifos, chlorpyrifos-methyl and buprofezin which ranged between 12 and 54% (LODs between 3.14 and 72.4 ng g−1), which are the pesticides with the highest soil organic carbon sorption coefficient (KOC) values. Using a one-sample test (Student's t-test) with fortified samples at two concentration levels in each type of soil, no significant differences were observed between the real and the experimental values (accuracy percentages ranged between 87 and 117%). It is the first time that the adsorptive potential of MWCNTs for the extraction of organophosphorus pesticides from soils is investigated.  相似文献   

14.
Summary A sample preparation method has been developed for the determination of chlorinated phenols in water. The method is based on a supported liquid membrane extraction system connected on-line to liquid chromatography with electrochemical detection. The supported liquid membrane technique utilizes a porous PTFE membrane. The membrane is impregnated with an organic solvent which forms a barrier between two aqueous phases and enables selective extraction. The technique can easily be coupled in a flow system. In this investigation five chlorinated phenols (1–5 chlorine atoms) were extracted from natural water samples. Extraction for 30 minutes resulted in detection limits of approximately 25 ng L–1.  相似文献   

15.
A novel sample pre-treatment technique termed dispersive suspended microextraction (DSME) coupled with gas chromatography-flame photometric detection (GC-FPD) has been developed for the determination of eight organophosphorus pesticides (ethoprophos, malathion, chlorpyrifos, isocarbophos, methidathion, fenamiphos, profenofos, triazophos) in aqueous samples. In this method, both extraction and two phases’ separation process were performed by the assistance of magnetic stirring. After separating the two phases, 1 μL of the suspended phase was injected into GC for further instrument analysis. Varieties of experiment factors which could affect the experiment results were optimized and the following were selected: 12.0 μL p-xylene was selected as extraction solvent, extraction speed was 1200 rpm, extraction time was 30 s, the restoration speed was 800 rpm, the restoration time was 8 min, and no salt was added. Under the optimum conditions, limits of detections (LODs) varied between 0.01 and 0.05 μg L−1. The relative standard deviation (RSDs, n = 6) ranged from 4.6% to 12.1%. The linearity was obtained by five points in the concentration range of 0.1–100.0 μg L−1. Correlation coefficients (r) varied from 0.9964 to 0.9995. The enrichment factors (EFs) were between 206 and 243. In the final experiment, the developed method has been successfully applied to the determination of organophosphorus pesticides in wine and tap water samples and the obtained recoveries were between 83.8% and 101.3%. Compared with other pre-treatment methods, DSME has its own features and could achieve satisfied results for the analysis of trace components in complicated matrices.  相似文献   

16.
A novel and rapid solventless microwave‐assisted extraction coupled with low‐density solvent‐based in‐tube ultrasound‐assisted emulsification microextraction has been developed for the efficient determination of nine organophosphorus pesticides in soils by GC analysis with microelectron capture detection. A specially designed, homemade glass tube inbuilt with a scaled capillary tube was used as an extraction device to collect and measure the separated extractant phase easily. Parameters affecting the efficiencies of the developed method were thoroughly investigated. From experimental results, the following conditions were selected for the extraction of organophosphorus pesticides from 1.0 g of soil sample to 5 mL of aqueous solution under 226 W of microwave irradiation for 2.5 min followed by ultrasound‐assisted emulsification microextraction with 20 μL toluene for 30 s and then centrifugation at 3200 rpm for 3 min. Detections were linear in the range of 0.25–10 ng/g with detection limits between 0.04 and 0.13 ng/g for all target analytes. The applicability of the method to real samples was assessed on agricultural contaminated soils and the recoveries ranged between 91.4 and 101.3%. Compared to other methods, the present method was shown to be highly competitive in terms of sensitivity, cost, eco‐friendly nature, and analysis speed.  相似文献   

17.
A new sol–gel hybrid methyltrimethoxysilane‐chloropropyltriethoxysilane was prepared as sorbent for solid‐phase extraction. The extraction efficiency of the prepared sol–gel hybrid methyltrimethoxysilane‐chloropropyltriethoxysilane was assessed by using three selected organophosphorus pesticides, namely, chlorpyrifos, profenofos, and malathion. Gas chromatography–mass spectrometry was used for detection of organophosphorus pesticides. Several vital parameters were optimized to identify the best extraction conditions. Under the optimum extraction conditions, solid‐phase extraction‐methyltrimethoxysilane‐chloropropyltriethoxysilane method showed good linearity range (0.05‐1 μg/mL) with coefficient of determination more than 0.995. The limits of detection obtained were in the range of 0.01–0.07 μg/mL and limits of quantification ranging from 0.03 to 0.21 μg/mL. The limits of detection obtained for the developed method were 2.3–6.5× lower than the limits of detection of commercial octadecyl silica sorbent. Real samples analysis was carried out by applying the developed method on red apple and purple grape samples. The developed method exhibited good recoveries (88.33–120.7%) with low relative standard deviations ranging from 1.6 to 3.3% compared to commercial octadecyl silica sorbent, which showed acceptable recoveries (70.3–100.2%) and relative standard deviations (6.3–8.8%). The solid‐phase extraction‐methyltrimethoxysilane‐chloropropyltriethoxysilane method is presented as an alternative extraction method for determination of organophosphorus pesticides.  相似文献   

18.
Summary Two procedures, based on large-volume injection with a programmed-temperature vaporizer (PTV), have been developed for the determination of several triazine and organophosphorus pesticides. The use of PTV for injection in gas chromatography (GC) has enabled the introduction of up to 200 μL sample extract into the GC, thus increasing the sensitivity of the method. PTV injection has been combined off-line with two different microextraction procedures—liquid-liquid partition and solid-phase extraction. A simple and rapid off-line liquid-liquid microextraction procedure (5 mL water/1 mL methyltert-butyl ether) was applied to surface water samples spiked at levels between 0.01 and 5μg L−1. Recoveries of the overall procedure were >80% and the precision was better than 15%. Detection limits were <30 ngL−1 from 200-μL injections in GC-NPD analysis of triazines and GC-FPD analysis of organophosphorus pesticides. Off-line automated solid-phase extraction with C18 cartridges has been applied to water samples (50 mL) spiked at 0.01, 0.1 and 1 μg L−1. The overall procedure was satisfactory (recoveries >80% and coefficients of variation <12%) and the limits of detection ranged from 1 to 9 ng L−1. Finally, several surface water samples were anlysed, and triazine herbicides were detected at concentrations of approx. 0.1–0.2 μg L−1. The results were similar to those obtained by conventional solvent extraction then GC-MSD after splitless injection of 2 μL.  相似文献   

19.
An in-syringe ultrasound-assisted emulsification microextraction (USAEME) was developed for the extraction of organophosphorus pesticides (OPPs) from water samples. The OPPs subsequently analyzed gas chromatography (GC) using a microelectron capture detector (μECD). Ultrasound radiation was applied to accelerate the emulsification of μL-level low-density organic solvent in aqueous solutions to enhance the microextraction efficiency of OPPs in the sample preparation for GC-μECD. Parameters affecting the efficiency of USAEME, such as the extraction solvent, solvent volume, pH, salt-addition, and extraction time were thoroughly investigated. Based on experimental results, OPPs were extracted from a 5 mL aqueous sample by the addition of 20 μL toluene as the extraction solvent, followed by ultrasonication for 30 s, and then centrifugation for 3 min at 3200 rpm, offered the best extraction efficiency. Detections were linear in the concentration of 0.01–1 μg/L with detection limits between 1 ng/L and 2 ng/L for OPPs. Enrichment factors ranged from 330 to 699. Three spiked aqueous samples were analyzed, and recovery ranged from 90.1% to 104.7% for farm-field water, and 90.1% to 101.8% for industrial wastewater. The proposed method provides a simple, rapid, sensitive, inexpensive, and eco-friendly process for determining OPPs in water samples.  相似文献   

20.
Summary A multiresidue method for the analysis of 28 common organophosphorus pesticides and 3 of their main metabolites (paraoxon-ethyl, paraoxon-methyl and malaoxon) in a variety of crop samples has been developed. An aliquot of the chopped sample is homogenized with an organic solvent. The efficiency of extraction methods using methanol, acetone and acetonitrile was evaluated. The acetonitrile gives higher recoveries and minimizes co-extractives from the samples matrix. The resulting aqueous acetonitrile extract is filtered and cleaned by solid phase extraction (SPE). For SPE three different types of adsorption materials (Carbograph 1, LiChrobut-EN and Amberchrom CG-161m) were compared. The cleaned-up extract is injected into the LC system. Three different analytical columns were tested in conjunction with two mobile phase compositions of different polarity. The use of LC-DAD techniques allowed the identification of both organophosphorus pesticides and metabolites by means of standard and spectral comparison, respectively. The accuracy of the quantitative determination measured in terms of average percentage recovery of 31 compounds in crop samples was 61–96% with a relative standard deviation of 5–10%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号