共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Diiodothyronines 3,5-diiodothyronine (3,5-T2), 3',5'-diiodothyronine (3',5'-T2), and 3,3'-diiodothyronine (3,3'-T2) are important metabolites of 3,5,3'-triiodothyronine (T3) and 3,3',5'-triiodothyronine (rT3; reverse T3). In this paper, a novel and rapid method for identifying and quantifying 3,5-T2, 3',5'-T2 and 3,3'-T2 has been introduced using electrospray ionization tandem mass spectrometry (ESI-MS/MS). Fragmentation patterns were proposed on the basis of our data obtained by ESI-MS/MS. MS2 spectra in either negative ionization mode or positive ionization mode can be used to differentiate 3,5-T2, 3',5'-T2 and 3,3'-T2. On the basis of the relative abundance of fragment ions in MS2 spectra under the positive ionization mode, quantification of the 3,5-T2, 3',5'-T2 and 3,3'-T2 isomers in mixtures is also achieved without prior separation. 相似文献
3.
Zhang Y Conrad AH Thoma R Conrad GW 《Rapid communications in mass spectrometry : RCM》2006,20(3):481-486
In this work two monoiodothyronines, 3-T1 and 3'-T1, have been analyzed using electrospray ionization tandem mass spectrometry (ESI-MS/MS). Fragmentation patterns were proposed based on our data obtained by ESI-MS/MS. MS2 spectra in either negative or positive ion mode can be used to differentiate 3-T1 and 3'-T1. Based on the relative abundance of fragment ions in MS2 spectra in the negative ion mode, quantification of the 3-T1 and 3'-T1 isomers in mixtures is achieved without prior separation. Solid-phase extraction in combination with ESI-MS/MS provides a practicable procedure that can be used to determine the molar ratio of 3-T1 and 3'-T1 in human serum with an error less than 3%. The detection limits for 3-T1 and 3'-T1 were 0.5 and 0.7 pg/microL, respectively. 相似文献
4.
Comprehensive mass spectral fragmentation patterns have been established for sequencing chromatographically isolated A-type proanthocyanidins (PAs) using electrospray ionization tandem mass spectrometry (ESI-MS(n)) in the positive ion mode similar to those used for sequencing previously reported B-type PAs. Sequence-identifying fragmentations for A-type PAs include heterocyclic ring fission (HRF), retro-Diels-Alder (RDA) fission, benzofuran-forming (BFF) fission, and quinone methide (QM) fission. There is commonality in fragmentation patterns between A-type and B-type PAs, but distinguishing features in the mass spectral patterns between the two classes include 2-Da mass differences in the pseudo molecular ions, the propensity for the A-type PAs to undergo QM fissions and yield bis-quinoid ions as opposed to mono-quinoid ions in the upper unit of the sequence, and the reluctance of A-type linkages to undergo RDA, BFF, and BFF/H(2)O fissions from the upper unit. The positions of one or more A-type (C2-->O-->C7') ether linkages have been located in sequences of PAs ranging in chain lengths of two to five monomer units using ESI-MS(n) data. Using the fragmentation information from ESI-MS(n) experiments, a total of 17 PAs were structurally sequenced by systematic real time ESI-MS(n). Among them ten A-type and six B-type hop PAs are reported here for the first time. 相似文献
5.
Characterizing polymerase chain reaction (PCR) amplicons has been accomplished for the first time using flow injection analysis coupled to electrospray ionization mass spectrometry (ESI-MS). The PCR amplicons were amplified at the human tyrosine hydroxylase short tandem repeat locus from an individual homozygotic for the 9.3 allele. One product was amplified using Pfu polymerase and yielded a blunt-ended amplicon of 82 base-pairs (bp) in length. The second PCR product was amplified using Taq polymerase that resulted in an amplicon with cohesive termini of 82 bp plus either mono- or diadenylation. The two PCR amplicons were alternatively injected using a 0.5-microL loop at 2 microM for the Pfu amplicon and 1 microM for the Taq amplicon with a flow rate of 200 nL/min during data acquisition. Both PCR amplicons were accurately identified using mass measurements illustrating the compatibility of ESI-MS for genotyping short tandem repeat sequences and the potential for high-throughput genotyping of large PCR amplicons. 相似文献
6.
Minakata K Nozawa H Gonmori K Yamagishi I Suzuki M Hasegawa K Watanabe K Suzuki O 《Analytical and bioanalytical chemistry》2011,400(7):1945-1951
An electrospray ionization tandem mass spectrometric (ESI-MS-MS) method has been developed for the determination of cyanide
(CN–) in blood. Five microliters of blood was hemolyzed with 50 μL of water, then 5 μL of 1 M tetramethylammonium hydroxide solution
was added to raise the pH of the hemolysate and to liberate CN– from methemoglobin. CN– was then reacted with NaAuCl4 to produce dicyanogold, Au(CN)2–, that was extracted with 75 μL of methyl isobutyl ketone. Ten microliters of the extract was injected directly into an ESI-MS-MS
instrument and quantification of CN– was performed by selected reaction monitoring of the product ion CN– at m/z 26, derived from the precursor ion Au(CN)2– at m/z 249. CN– could be measured in the quantification range of 2.60 to 260 μg/L with the limit of detection at 0.56 μg/L in blood. This
method was applied to the analysis of clinical samples and the concentrations of CN– in the blood were as follows: 7.13 ± 2.41 μg/L for six healthy non-smokers, 3.08 ± 1.12 μg/L for six CO gas victims, 730 ± 867 μg
for 21 house fire victims, and 3,030 ± 97 μg/L for a victim who ingested NaCN. The increase of CN– in the blood of a victim who ingested NaN3 was confirmed using MS-MS for the first time, and the concentrations of CN– in the blood, gastric content and urine were 78.5 ± 5.5, 11.8 ± 0.5, and 11.4 ± 0.8 μg/L, respectively. 相似文献
7.
8.
Structural analysis of saponins from medicinal herbs using electrospray ionization tandem mass spectrometry 总被引:4,自引:0,他引:4
Liu S Cui M Liu Z Song F Mo W 《Journal of the American Society for Mass Spectrometry》2004,15(2):133-141
The underivatized saponins from Tribulus terrestris and Panax ginseng have been investigated by electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)). In ESI-MS spectra, a predominant [M + Na](+) ion in positive mode and [M - H](-) ion in negative mode were observed for molecular mass information. Multi-stage tandem mass spectrometry of the molecular ions was used for detailed structural analysis. Fragment ions from glycoside cleavage can provide information on the mass of aglycone and the primary sequence and branching of oligosaccharide chains in terms of classes of monosaccharides. Fragment ions from cross-ring cleavages of sugar residues can give some information about the linkages between sugar residues. It was found that different alkali metal-cationized adducts with saponins have different degrees of fragmentation, which may originate from the different affinity of a saponin with each alkali metal in the gas phase. ESI-MS(n) has been proven to be an effective tool for rapid determination of native saponins in extract mixtures, thus avoiding tedious derivatization and separation steps. 相似文献
9.
Eighteen isoprenylated flavonoids (8 flavanones, 3 flavanols, and 7 chalcones) isolated from Kushen or synthesized were studied by positive and negative ion electrospray ionization multistage tandem mass spectrometry (ESI-MS(n)). Plausible fragmentation patterns were obtained by comparing their MS(n) spectra with each other, which were further supported by high-resolution MS data and two model compounds. It was shown that the 2'-OH group would make the C-ring of flavonoids studied more labile through a six-membered mechanism, resulting in base peaks of (1,3)A+ (positive mode) and (1,4)A(-) (negative mode). In addition, the 2'-OH is also responsible for the neutral loss of water in (+)ESI/MS(2) of flavanones. The neutral loss of water (or methanol) in (-)ESI/MS(2) of flavanols was elucidated by a E2 elimination mechanism. Different relative abundances (RA) of (1,3)A(+) and S(+) in (+)ESI/MS(2) spectra were used to discriminate flavanones with their open-ring products, chalcones, since the equilibrium for flavanone<-->chalcone isomerization in ESI ion source could not be obtained in positive mode. 相似文献
10.
Presented is a method for analyzing sulfated peptides, and differentiating the post-translational modification (PTM) from its isobaric counterpart phosphorylation, using quadrupole time-of-flight (Qq/TOF) mass spectrometry (MS) and positive ion nanoelectrospray MS/MS. A set of commercially available sulfo- and phosphopeptide standards was analyzed via in-source dissociation and MS/MS to generate fragmentation signatures that were used to characterize and differentiate the two modifications. All of the phosphorylated peptides retained their +80 Da modifications under collision-induced decomposition (CID) conditions and peptide backbone fragmentation allowed for the site-specific identification of the modification. In sharp contrast, sulfated peptides lost SO3 from the precursor as the collision energy (CE) was increased until only the non-sulfated form of the peptide was observed. The number of 80 Da losses indicated the number of sulfated sites. By continuing to ramp the CE further, it was possible to fragment the non-sulfated peptides and obtain detailed sequence information. It was not possible to obtain site-specific information on the location of the sulfate moieties using positive ion MS/MS as none of the original precursor ions were present at the time of peptide backbone fragmentation. This method was applied to the analysis of recombinant human B-domain deleted factor VIII (BDDrFVIII), which has six well-documented sulfation sites and several potential phosphorylation sites located in two of the sulfated regions of the protein. Seven peptides with single and multiple +80 Da modifications were isolated and analyzed for their respective PTMs. The fragmentation patterns obtained from the BDDrFVIII peptides were compared with those obtained for the standard peptides; and in all cases the peptides were sulfated. None of the potential phosphorylation sites were found to be occupied, and these results are consistent with the literature. 相似文献
11.
A rapid and sensitive electrospray ionization tandem mass spectrometric (ESI-MS-MS) procedure was developed for the determination of cyanide (CN−). CN− in biological fluids was reacted with NaAuCl4 to produce dicyanogold, Au(CN)2−, which was extracted with methyl isobutyl ketone (MIBK). One microliter of the extract was injected directly into an ESI-MS-MS instrument. Quantification of CN− was performed by selected reaction monitoring of the product ion CN− at m/z 26 that derived from precursor ion Au(CN)2− at m/z 249. CN− could be measured in the quantification range of 10−7 to 5 × 10−5 M with the limit of detection at 4 × 10−8 M using 10 μL of urine within 10 min. A victim's urine and gastric content were diluted with water to 4-fold and 500-fold and measured, respectively. 相似文献
12.
Fragmentation study of simvastatin and lovastatin using electrospray ionization tandem mass spectrometry 总被引:2,自引:0,他引:2
The fragmentation mechanism of simvastatin and lovastatin was investigated using both triple quadrupole and ion trap mass spectrometers. The elimination of the ester side-chain followed by dehydration and dissociation of the lactone moiety were observed as the main fragmentation pathways for both compounds. Another major fragmentation process was a C==C double-bond facilitated rearrangement. Our tandem mass spectrometric (MS/MS) data suggested that the beta-hydroxy group was involved in the fragmentation by interacting with the carboxyl group generated from the ring opening of the lactone. As a result, a facile neutral loss of 60 Da (CH(3)COOH or a combination of CH(2)==C==O and H(2)O) was detected. MS/MS studies of the structural analogs also provided evidence that the dehydration of the beta-hydroxy lactone generated preferentially the beta,gamma-unsaturated lactones. 相似文献
13.
Twenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem mass spectrometry (ESI-MS and ESI-MS/MS) and electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry (ESI-FAIMS-MS and ESI-FAIMS-MS/MS), in positive and negative ionization modes. Three separate sets of ESI-FAIMS conditions were used for the separation and detection of the 20 AAs. Typically ESI-FAIMS-MS showed somewhat improved sensitivity and significantly better signal-to-noise ratios than ESI-MS mainly due to the elimination of background noise. However, the difference between ESI-FAIMS-MS and ESI-MS/MS was significantly less. ESI-FAIMS was able to partially or completely resolve all the isobaric amino acid overlaps such as leucine, isoleucine and hydroxyproline or lysine and glutamine. Detection limits for the amino acids in ESI-FAIMS-MS mode ranged from 2 ng/mL for proline to 200 ng/mL for aspartic acid. Overall, ESI-FAIMS-MS is the preferred method for the quantitative analysis of AAs in a hydrolyzed yeast matrix. 相似文献
14.
A series of chalcones were characterized by electrospray ionization tandem mass spectrometry (MS(n)). Several ionization modes were evaluated, including protonation, deprotonation and metal complexation, with metal complexation being the most efficient. Collision-activated dissociation (CAD) was used to characterize the structures, and losses commonly observed include H(2), H(2)O, CO and CO(2), in addition to methyl radicals for the methoxy-containing chalcones. CAD of the metal complexes, especially [Co(II) (chalcone-H) 2,2'-bipyridine](+), allowed the most effective differentiation of the isomeric chalcones with several diagnostic fragment ions appearing upon activation of the metal complexes. MS(n) experiments were performed to support identification of some fragment ions and to verify the proposed fragmentation pathways. In several cases, MS(n) indicated that specific neutral losses occurred by stepwise pathways, such as the neutral loss of 44 u as CH3* and HCO*, or CH(4) and CO, in addition to CO(2). 相似文献
15.
Anna Vallverdú‐Queralt Olga Jáuregui Alexander Medina‐Remón Cristina Andrés‐Lacueva Rosa M. Lamuela‐Raventós 《Rapid communications in mass spectrometry : RCM》2010,24(20):2986-2992
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
16.
Phytochelatins (PCs, also known as class III metallothioneins), a family of sulfhydryl-rich peptides with the formula (gamma-GluCys)(n)Gly(Pc(n), n = 2-11), are induced in plants, yeast and fungi exposed to heavy metals, and are thought to detoxify metals by forming PC- metal complexes. Although PCs have been detected, PC- metal complexes have not been well characterized. In this work, nano-electrospray ionization tandem mass spectrometry (nano-ESI-MS/MS) and capillary liquid chromatography/electrospray ionization tandem mass spectrometry (capillary LC/ESI-MS/MS) methods were used to analyze PC - Cd complexes isolated from Datura innoxia, also known as Jimsonweed, cell culture exposed to Cd. With nano-ESI-MS/MS and capillary LC/ESI-MS/MS we could simultaneously detect the presence of PCs and PC - Cd complexes from plant cell extracts, unambiguously identify these species and elucidate the nature of individual PC - Cd complexes. Phytochelatins with n = 3-6 were detected, as were PC - Cd complexes with PC(3), PC(4) and PC(5). This is the first study to report the size and nature of native PC - Cd complexes from plant tissue samples. These results demonstrate that the direct analysis of plant extracts using nano-ESI-MS/MS and capillary LC/ESI-MS/MS methods is simple and sensitive to the range of PCs and PC - Cd complexes in plants. Hence these methods open up new opportunities for further quantitative analysis of PCs and PC - metal complexes in cell culture and plant systems to understand the relationship between the biosynthesis of these compounds and metal tolerance. 相似文献
17.
18.
The electrospray ionization ion trap multiple-stage tandem mass spectrometry (ESI-MSn) and electrospray ionization Fourier transform ion cyclotron resonance multiple-stage tandem mass spectrometry (ESI-FT-ICR-MSn) have been applied successfully to the direct investigation of a number of dibenzocyclooctadiene lignan constituents from the methanol extracts of the Fructus Schisandrae in the positive ion mode. The detailed structural characterization of the same skeleton and different peripheral substituents had been studied and the precise elemental compositions of ions at high mass resolution had been obtained. So the fragmentation mechanisms could be clarified. And the lignan components in Schisandra chinensis (Turcz.) Baill. fruits (SCF) and Schisandra sphenanthera Rehd. et Wils. fruits (SSF) were identified by comparing the structural information and fragmentation mechanisms. Then a pair of isobaric compounds was differentiated. Meanwhile these two similar fruits were distinguished. The research results demonstrated that ESI-MSn technique is a sensitive, selective and effective tool for the direct analysis and rapid determination of constituents in complex mixtures from nature products. And these should be useful for the identification of similar compounds and differentiation of similar species from Chinese herbs. 相似文献
19.
Study of electrospray ionization tandem mass spectrometry of the benzofuranone compounds 总被引:1,自引:0,他引:1
Zhan Qi Niu~ 《中国化学快报》2008,19(3):324-328
A detailed analysis of benzofuranone compounds under multiple tandem mass spectrometry (ESI-MS^n) conditions is reported. Element composition data of the fragment ions were obtained with the aid of comparison of the multiple tandem mass spectra of four compounds, and the structures of which are identical except for some substituted groups or epimers or cis-trans-isomers. Attempts have been made to provide rational pathways for the formation of the fragment ions from these protonated compounds. And the structure-fragmentation relationships will facilitate the characterization of the structures of other analogs. 相似文献
20.
Study of the electrospray ionization tandem mass spectrometry of sildenafil derivatives 总被引:3,自引:0,他引:3
A detailed analysis of the product ion spectrum generated from the protonated molecule of sildenafil (Viagra(R)) under multiple tandem mass spectrometry (ESI-MS(n)) conditions using an ion-trap mass spectrometer is reported. Molecular composition data of the fragment ions were obtained with the aid of comparisons of the multiple tandem mass spectra of eight sildenafil derivatives in two series, the structures of which are identical except for some substituted alkyl groups. Attempts have been made to provide rational pathways for the formation of the fragment ions from these protonated sildenafil derivatives. The structure-fragmentation relationships will facilitate the characterization of the structures of other sildenafil analogs. 相似文献