首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
This work investigates for the first time the potential of mixed-mode (anion-exchange with reversed-phase) high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (ICP-MS) for the simultaneous retention and selective separation of a range of inorganic and organically-bound selenium (Se) species. Baseline separation and detection of selenocystine (SeCys2), Se-methyl-selenocysteine (SeMC), selenomethionine (SeMet), methylseleninic acid (MSA), selenite, γ-glutamyl-methyl-selenocysteine (γ-glutamyl-SeMC), and selenate in a Se standard mixture by mixed-mode HPLC-ICP-MS was achieved by switching between two citrate mobile phases of different pH and ionic strength within a single chromatographic run of 20 min. Limits of detection obtained for these Se species ranged from 80 ng kg?1 (for SeMC) to 123 ng kg?1 (for selenate). Using this approach as developed for selenium speciation, an adequate separation of inorganic and organic As compounds was also achieved. These include arsenite, arsenate, arsenobetaine (AsB) and dimethylarsenic acid (DMA), which may coexist with Se species in biological samples. Application of the newly proposed methodology to the investigation of the elemental species distribution in watercress (used as the model sample) after enzymatic hydrolysis or leaching in water by accelerated solvent extraction (ASE) was addressed. Only SeMet, SeMC and selenate could be tentatively identified in watercress extracts by mixed-mode HPLC-ICP-MS and retention time matching with standards. Recoveries (n = 3) of these Se species from samples spiked with standards averaged 102% (for SeMC), 94.9% (for SeMet) and 98.3% (for selenate). Verification of the presence of SeMet and SeMC in an enzymatic watercress extract was achieved by on-line HPLC-ESI MS/MS in selected reaction monitoring (SRM) mode.  相似文献   

2.
A simple, sensitive, and cost-effective analytical method was developed for the speciation analysis of inorganic selenium by combining a nano-TiO2 preconcentration with an ion chromatography-conductivity detection (IC-CD) system. The experimental conditions for the simultaneous adsorption and desorption of Se(IV) and Se(VI) were carefully investigated. Under the established optimum condition, the Se(IV) and Se(VI) ions could been simultaneously adsorbed onto the nano-TiO2 surface at pH 4.0, and then effectively desorbed by 0.1 M sodium hydroxide eluent. The adsorption process was fast and reached adsorption equilibrium within 10 min. The nano-TiO2 also exhibited high adsorption capacity with 11.3 mg g? 1 for Se(IV) and 8.34 mg g? 1 for Se(VI). The enrichment factors for Se(IV) and Se(VI) were calculated to be 39 and 30, respectively, with sample volume of 50 mL. The detection limits (3σ) were 0.8 μg L? 1 for Se(IV) and 0.4 μg L? 1 for Se(VI), which were sensitive enough for the routine analysis of water and drink samples. The relative standard deviation was calculated to be < 4% (n = 6) for detection of 30 μg L? 1 Se(IV) and 30 μg L? 1 Se(VI). The results of the present work confirmed that our developed nano-TiO2-IC-CD method could be applied for the detection of inorganic selenium species in tap water and drink samples with good recoveries in the range of 82%–108%.  相似文献   

3.
Chen B  He M  Mao X  Cui R  Pang D  Hu B 《Talanta》2011,83(3):724-731
Room-temperature ionic liquids (RTILs) improved reversed-phase high performance liquid chromatography (RP-HPLC) on-line combined with inductively coupled plasma mass spectrometry (ICP-MS) was developed for selenium speciation. The different parameters affecting the retention behaviors of six target selenium species especially the effect of RTILs as mobile phase additives have been studied, it was found that the mobile phase consisting of 0.4% (v/v) 1-butyl-3-methylimidazolium chloride ([BMIM]Cl), 0.4% (v/v) 1-butyl-2,3-dimethylimidazolium tetrafluroborate ([BMMIM]BF4) and 99.2% (v/v) water has effectively improved the peak profile and six target selenium species including Na2SeO3 (Se(IV)), Na2SeO4 (Se(VI)), l-selenocystine (SeCys2), d,l-selenomethionine (SeMet), Se-methylseleno-l-cysteine (MeSeCys), seleno-d,l-ethionine (SeEt) were separated in 8 min. In order to validate the accuracy of the method, a Certified Reference Material of SELM-1 yeast sample was analyzed and the results obtained were in good agreement with the certified values. The developed method was also successfully applied to the speciation of selenium in Se-enriched yeasts and clover. For fresh Se-enriched yeast cells, it was found that the spiked SeCys2 in living yeast cells could be transformed into SeMet. Compared with other ion-pair RP-HPLC-ICP-MS approaches for selenium speciation, the proposed method possessed the advantages including ability to regulate the retention time of the target selenium species by selecting the suitable RTILs and their concentration, simplicity, rapidness and low injection volume, thus providing wide potential applications for elemental speciation in biological systems.  相似文献   

4.
A new method for the speciation analysis of selenite (Se-IV), selenate (Se-VI), and selenocyanate (SeCN) is described and first results are presented on the distribution of these species in wastewater samples from a Brazilian oil refinery plant. The method is based on the ion chromatographic separation of these species followed by on-line detection of 77Se, 78Se, and 82Se using quadrupole inductively coupled plasma-mass spectrometry (ICPMS). The system employed consisted of a HPLC pump equipped with a manual syringe loading injector, and an anion exchange column (Metrosep A Supp1), the latter interfaced with the ICPMS via a concentric nebulizer–cyclonic spray chamber sample introduction device. Several eluents already described in the literature for the speciation analysis of inorganic selenium were tested, permitting in most cases a good separation of Se(IV) and Se(VI), however, resulting all in very long residence times (> 30 min) and associated peak broadening for the SeCN ion. This drawback could be effectively avoided by using as the mobile phase a solution of cyanuric acid (3 mmol L−1), modified with acetonitrile (2% v/v) and percchlorate acid (2.5 mmol L−1). Typical retention times (s) for the three analyte species were: selenite (210) < selenate (250) < selenocyanate (450). Repeatabilities in peak position were better than 1% and in peak area evaluation about 3%. Absolute limits of detection (in ng) for these species using an ELAN 5000 instrument and a 500-μL sample injection loop are 0.04, 0.05 and 0.09, respectively. No certified reference materials were available for this study, however, results on spiked wastewater samples showed acceptable recoveries (80–110%) and repeatabilities (RSD < 5%), thus validating this method for its intended purpose. Once optimized, the method was applied to wastewater samples from an oil refinery plant. In all samples until now analyzed, selenocyanate was by far the most abundant selenium species reaching concentrations of up to 90 μg L−1. Selenite was detected only in one sample and selenate could not identified in any of the samples analyzed. Total concentrations of selenium in most samples, assessed by hydride generation ICPMS and by solution nebulization inductively coupled plasma optical emission spectrometry (ICPOES), exceeded those obtained from speciation analysis, indicating the presence of other selenium species not observed by the here used methodology.  相似文献   

5.
An analytical procedure for selenium speciation of analysis of selenourea (SeU), selenoethionine (SeE), selenomethionine (SeM), Se(VI), Se(IV), dimethylselenide (dMeSe) and dimethyldiselenide (dMedSe) was developed, based on two complementary liquid chromatography (LC) techniques coupled with inductively coupled plasma-mass spectrometry (ICP-MS). Specifically, strong anion exchange (SAX) chromatography coupled with ICP-MS was used for the separation and quantification of all the earlier mentioned Se compounds, except for the two methyl selenides, which could be separated and determined by reversed phase chromatography coupled with ICP-MS. This procedure was applied to a soil sample from the warm springs area of Thermopyles (Greece). For leaching the Se species from the soil sample, four extraction methods, using water at ambient temperature, hot water, methanol and 0.5 M HCl, were tested for their efficiency of extracting the different Se species. The speciation results obtained by the LC-ICP-MS methods were compared with those obtained by voltammetric techniques. The determination of total selenium in the sample was achieved by graphite furnace atomic absorption spectrometry, as well as by ICP-atomic emission spectrometry, after suitable digestion of the sediment sample.  相似文献   

6.
In this study, thiourea (TU) was novelly developed as a reduction reagent for on-line pre-reduction of selenium(VI) before conventional hydride generation (HG) by KBH4/NaOH–HCl. After TU on-line pre-reduction, the HG efficiency of Se(VI) has been greatly improved and because even higher than that of the same amount of Se(IV) obtained in the conventional HG system. The possible pre-reduction mechanism is discussed. The detection limit (DL) of selenate reaches 10 pg mL 1 when using on-line TU pre-reduction followed by HG atomic fluorescence detection. When TU pre-reduction followed by HG is used as an interface between ion-pair high performance liquid chromatography and atomic fluorescence spectrometry, selenocystine, selenomethionine, selenite and selenate can be measured simultaneously and quantitatively. The DLs of these are 0.06, 0.08, 0.05 and 0.04 ng mL 1, respectively, and the relative standard deviations of 9 duplicate runs for all the 4 species are less than 5%. Furthermore, it was successfully applied to Se speciation analysis of cultured garlic samples, and validated by determination of total selenium and selenium species in certified reference material NIST 1946.  相似文献   

7.
We have developed an on-line digestion device-based on the nano-TiO2-catalyzed photooxidation of arsenic species—for coupling between microbore anion-exchange chromatography (μ-LC) and hydride generation (HG)-inductively coupled plasma mass spectrometry (ICP-MS) systems that can be used for the determination of urinary arsenic species. To maximize the signal intensities of the desired arsenic species, we optimized the photocatalytic oxidation efficiency of the analyte species and developed a rapid on-line pre-reduction process for converting the oxidized species into As(III) prior to HG-ICP-MS determination. Under the optimized conditions for the nano-TiO2-catalyzed photooxidation-i.e., using 1 g of nano-TiO2 per-liter, at pH 5.2, and illuminating for 3 min- As(III), monomethylarsenoic acid (MMA), and dimethylarseinic acid (DMA) can be converted quantitatively into As(V). To attain maximal hydride generation efficiency, 0.5% Na2S2O4 solution, which can reduce As(V) to As(III) virtually instantaneously upon on-line mixing, was added as a pre-reductant prior to performing the HG step. In light of all the HG efficiency of tested arsenicals were improved and a segmented-flow technique was employed to avoid the loss of peak resolution when using our proposed on-line μ-LC-UV/nano-TiO2/HG-ICP-MS, the detection limits for As(III), MMA, DMA, and As(V) were all in the range of sub-microgram-per-liter (based on 3 sigma). A series of validation experiments-analysis of neat and spiked urine samples-indicated that our proposed methods can be applied satisfactorily to the determination of As(III), MMA, DMA, and As(V) in urine samples.  相似文献   

8.
The purpose of this paper is to develop an easy and quick on-line selenium speciation method (LC-UV-HG-AFS) in cow milk obtained after different supplementation to cow feed. This study focuses on selenium speciation in cow milk after the use of different selenium species (organic selenium as selenised yeast and inorganic selenium as sodium selenite) in the supplementation of forages. Separation was carried out on a μBondapack C18 column with the positively charged ion-pairing agent tetraethylammonium chloride in the mobile phase. The optimization of pre-reduction conditions was carried out; this step was done with UV irradiation and a heating block to improve the reduction of the different Se-compounds. Variables such as exposure time, hydrochloric acid concentration and temperature were studied. The detection limits for SeCyst2, Se(IV), SeMet and Se(VI) were 0.4, 0.5, 0.9 and 1.0 μg l−1, respectively. The proposed method was applied to cow milk samples. The milk samples obtained after an organic supplementation of feeding as selenised yeast present three species of selenium, SeCyst2, Se(IV) and SeMet, while only SeCyst2 and Se(IV) are present in milk samples obtained after an inorganic supplementation of feeding.  相似文献   

9.
A novel, fast, and cheap nonchromatographic method for direct speciation of dissolved inorganic and organic selenium species in environmental and biological samples was developed by flow injection (FI) dual-column preconcentration/separation on-line coupled with ICP-MS determination. In the developed technique, the first column packed with nanometer-sized Al(2)O(3) could selectively adsorb the inorganic selenium [Se(IV), Se(VI)], and the retained inorganic selenium could be eluted by 0.2 mol l(-1) NaOH, while the organic Se [selenocystine (SeCys(2)) and selenomethionine (Se-Met)] was not retained. On the other hand, the second column packed with mesoporous TiO(2) chemically modified by dimercaptosuccinic acid (DMSA) could selectively adsorb Se(IV) and SeCys(2) and barely adsorb Se(VI) and Se-Met. When the sample solution was passed through the column 1, separation of inorganic selenium and organic selenium could be achieved first. Then, the effluent from column 1 was successively introduced into the column 2 and the speciation of organic selenium could be attained due to the different adsorption behaviors of Se-Met and SeCys(2) on DMSA modified TiO(2). After that, the eluent from column 1 contained Se(IV), and Se(VI) was adjusted to desired pH and injected into column 2, and the speciation of Se(IV) and Se(VI) could also be realized thanks to their different retention on column 2. The parameters affecting the separation were investigated systematically and the optimal separation conditions were established. The detection limits obtained for Se(IV), Se(VI), Se-Met and SeCys(2) were 45-210 ng l(-1) with precisions of 3.6-9.7%. The proposed method has been successfully applied for the speciation of dissolved inorganic and organic selenium in environmental and biological samples. In order to validate the methodology, the developed method was also applied to the speciation of selenium in certified reference material of SELM-1 yeast, and the determined values were in good agreement with the certified values.  相似文献   

10.
Zhao Y  Zheng J  Yang M  Yang G  Wu Y  Fu F 《Talanta》2011,84(3):983-988
An enzyme-assisted extraction used to extract all species of selenium in rice sample and a sensitive analytical method for the determination of ultratrace Se(VI), Se(IV), SeCys2 (selenocystine) and SeMet (selenomethionine) with capillary electrophoresis-inductively coupled plasma mass spectrometry were firstly described in this study. The extraction method is simple, effective and can be used to extract trace selenium compounds in rice with high extraction efficiency and no altering its species. The analytical method has a detection limit of 0.1-0.9 ng Se/mL, and can be used to determine trace Se(VI), Se(IV), SeCys2 and SeMet in rice directly without any derivatization and pre-concentration. With the help of above methods, we have successfully determined Se(VI), Se(IV), SeCys2 and SeMet in selenium-enriched rice within 18 min with a recovery of 90-103% and a RSD (relative standard deviation, n = 6) of 3-7%. Our results indicated that selenium-enriched rice contained only one species of selenium, SeMet, and its concentration is in range of 0.136-0.143 μg Se/g dried weight. The proposed method providing a realistic approach for the nutritional and toxical evaluation of different selenium compounds in nutritional supplements.  相似文献   

11.
Liquid chromatography–inductively coupled plasma-mass spectrometry (LC–ICP-MS) was used for arsenic speciation analysis in tissues of bivalve mollusks (Anomalocardia brasiliana sp. and Macoma constricta sp.). Microwave and ultrasound radiation, combined with different extraction conditions (solvent, sample amount, time, and temperature), were evaluated for As-species extraction from the mollusks' tissues. Accuracy, extraction efficiency, and the stability of As species were evaluated by analyzing certified reference materials (DORM-2, dogfish muscle; BCR-627, tuna fish tissue; and SRM 1566b, oyster tissue) and analyte recovery tests. The best conditions were found to be microwave-assisted extraction using 200 mg of samples and water at 80 °C for 6 min. The agreement of As-species concentration in samples ranged from 97% to 102%. Arsenobetaine (AsB) was the main species present in bivalve mollusk tissues, while monomethylarsonic acid (MMA) and arsenate (As(V)) were below the limit of quantification (0.001 and 0.003 μg g 1, respectively). Two unidentified As species also were detected and quantified. The sum of the As-species concentration was in agreement (90 to 104%), with the total As content determined by ICP-MS after sample digestion.  相似文献   

12.
Gammelgaard B  Larsen EH 《Talanta》1998,47(2):503-507
Aqueous solutions and blood plasma spiked with selenite (Se(IV)), selenate (Se(VI)), selenomethionine (SeMet) or trimethylselenonium (TMSe) iodide were analyzed by Zeeman-corrected electrothermal atomic absorption spectrometry (ETAAS) using palladium as a chemical modifier, and by inductively coupled plasma mass spectrometry (ICP-MS). Using ETAAS, the sensitivities for Se(IV), SeMet and TMSe in aqueous solution were similar, whereas the sensitivity of Se(VI) was 63% of that value. In blood plasma, the ETAAS sensitivities of Se(IV) and Se(VI) were equal, whereas the sensitivities of SeMet and TMSe were 87 and 56%, respectively, of that value. In contrast, the ICP-MS sensitivities obtained for Se(VI), TMSe and SeMet were between 96 and 98% of that obtained for Se(IV) in aqueous solution and in blood plasma. It is concluded, that ICP-MS is superior to ETAAS as the problem of differences in sensitivity of the selenium species when using ETAAS are not prevalent when using the ICP-MS technique.  相似文献   

13.
Carbon tetrachloride vapor as gaseous phase modifier in a graphite furnace electrothermal vaporizer (GFETV) converts heavy volatile analyte forms to volatile and medium volatile chlorides and produces aerosol carrier effect, the latter being a less generally recognized benefit. However, the possible increase of polyatomic interferences in inductively coupled plasma mass spectrometry (GFETV–ICP-MS) by chlorine and carbon containing species due to CCl4 vapor introduction has been discouraging with the use of low resolution, quadrupole type MS equipment. Being aware of this possible handicap, it was aimed at to investigate the feasibility of the use of this halogenating agent in ICP-MS with regard of possible hazards to the instrument, and also to explore the advantages under these specific conditions. With sample gas flow (inner gas flow) rate not higher than 900 ml min−1 Ar in the torch and 3 ml min−1 CCl4 vapor flow rate in the furnace, the long-term stability of the instrument was ensured and the following benefits by the halocarbon were observed. The non-linearity error (defined in the text) of the calibration curves (signal versus mass functions) with matrix-free solution standards was 30–70% without, and 1–5% with CCl4 vapor introduction, respectively, at 1 ng mass of Cu, Fe, Mn and Pb analytes. The sensitivity for these elements increased by 2–4-fold with chlorination, while the relative standard deviation (RSD) was essentially the same (2–5%) for the two cases in comparison. A vaporization temperature of 2650 °C was required for Cr in Ar atmosphere, while 2200 °C was sufficient in Ar + CCl4 atmosphere to attain complete vaporization. Improvements in linear response and sensitivity were the highest for this least volatile element. The pyrolytic graphite layer inside the graphite tube was protected by the halocarbon, and tube life time was further increased by using traces of hydrocarbon vapor in the external sheath gas of the graphite furnace. Details of the modification of the gas supply for HGA-600MS furnace and the design of the volatilization device are described.  相似文献   

14.
An on-line FIA pretreatment with HBr/KBrO3, assisted by on-line focused microwave-induced digestion, has been coupled with hydride generation-atomic absorption spectrometry (HG-AAS) for final detection for total selenium determination. This total selenium determination is virtually independent of the different Se species investigated (selenite, selenate, selenomethionine, selenoethionine and selenocystine). Detection limits of 0.8 μg l−1 of Se can be achieved by AAS with precisions better than 5%. This continuous flow system for selenium determination allows a high sample throughput (about 30 samples h−1 can be analyzed) in which high automation can be achieved and constitutes a convenient real-time continuous detector for the different selenocompounds tested. Direct non-chromatographic speciation of inorganic selenium (selenite and selenate in their mixtures) is demonstrated by simple on-off operation of the focused microwaves connected in the flow system.

Validation of this simple on-line FIA system has been carried out by analyzing total Se recovered from spiked tap waters and by speciating mixtures of Se(IV) and Se(VI) spiked to the same samples. The fast conversion of Se compounds into volatile selenium could be considered as a sort of specific “general” detector for Se compounds which can be extremely useful for Se speciation by hybrid chromatographic techniques.  相似文献   


15.
Qingyang Liu 《Mikrochimica acta》2009,167(1-2):141-145
An on-line nano-TiO2 controlled volatilization system was developed for inorganic selenium speciation based on the irradiation of thiourea with ultraviolet light. It provides an effective hyphenation unit for atomic fluorescence spectrometry. The effects of several factors such as the acidity, the concentration of thiourea, the amounts of TiO2, the concentration of KBH4 and the flow rates of carrier gas were investigated. Under optimal conditions, the limit detections for Se(IV) and Se(VI) were 2.38 and 3.39 ng mL?1 (100?µL injection, 3 times of the baseline noise), respectively. The relative standard for deviations of 50 ng mL?1 Se(IV) and Se(VI) were 3.7% and 2.7%, respectively. The method has been applied for determination of inorganic selenium species in real samples and the recoveries were between 93% and 98%.  相似文献   

16.
A new selenized yeast reference material (SELM-1) produced by the Institute for National Measurement Standards, National Research Council of Canada (INMS, NRC) certified for total selenium (2,059±64 mg kg−1), methionine (Met, 5,758±277 mg kg−1) and selenomethionine (SeMet, 3,431±157 mg kg−1) content is described. The ±value represents an expanded uncertainty with a coverage factor of 2. SeMet and Met amount contents were established following a methanesulfonic acid digestion of the yeast using GC-MS and LC-MS quantitation. Isotope dilution (ID) calibration was used for both compounds, using 13C-labelled SeMet and Met. Total Se was determined after complete microwave acid digestion based on ID ICP-MS using a 82Se spike or ICP-OES spectrometry using external calibration. An international intercomparison exercise was piloted by NRC to assess the state-of-the-art of measurement of selenomethione in SELM-1. Determination of total Se and methionine was also attempted. Seven laboratories submitted results (2 National Metrology Institutes (NMIs) and 5 university/government laboratories). For SeMet, ten independent mean values were generated. Various acid digestion and enzymatic procedures followed by LC ICP-MS, LC AFS or GC-MS quantitation were used. Four values were based on species-specific ID calibration, one on non-species-specific ID with the remainder using standard addition (SA) or external calibration (EC). For total selenium, laboratories employed various acid digestion procedures followed by ICP-MS, AFS or GC-MS quantitation. Four laboratories employed ID calibration, the remaining used SA or EC. A total of seven independent results were submitted. Results for methionine were reported by only three laboratories, all of which used various acid digestion protocols combined with determination by GC-MS and LC UV. The majority of participants submitted values within the certified range for SeMet and total Se, whereas the intercomparison was judged unsuccessful for Met because only two external laboratories provided values, both of which were outside the certified range.  相似文献   

17.
Analytical methods for the speciation of selenium compounds: a review   总被引:1,自引:0,他引:1  
Selenium, like sulphur, exists in the environment in several oxidation states and as a variety of inorganic and organic compounds. Dissolved inorganic selenium can be found in natural waters as selenide Se (–II), as colloidal elemental selenium Se (0), as selenite anions HSeO 3 and SeO 3 2– i.e. Se (+IV) and as the selenate anion (SeO 4 2– ) i.e. Se (+VI). Organic forms of selenium that may be found in organisms, air or in the aqueous environment, are volatile (methylselenides) or non volatile (trimethylselenonium ion, selenoamino acids and their derivatives). Knowledge of the different chemical forms and their environmental and biomedical distribution is important because of the dependence of bioavailability and toxicity on speciation. This paper reviews the different analytical methods used for the speciation of selenium compounds, with special attention to inorganic selenium and organoselenium species.  相似文献   

18.
In the present work electrothermal vaporization (ETV) was used in both inductively coupled plasma mass spectrometry (ICP-MS) and optical emission spectrometry (OES) for sample introduction of solution samples. The effect of (Pd + Mg)-nitrate modifier and CaCl2 matrix/modifier of variable amounts were studied on ETV-ICP-MS signals of Cr, Cu, Fe, Mn and Pb and on ETV-ICP-OES signals of Ag, Cd, Co, Cu, Fe, Ga, Mn and Zn. With the use of matrix-free standard solutions the analytical curves were bent to the signal axes (as expected from earlier studies), which was observed in the 20–800 pg mass range by ICP-MS and in the 1–50 ng mass range by ICP-OES detection. The degree of curvature was, however, different with the use of single element and multi-element standards. When applying the noted chemical modifiers (aerosol carriers) in microgram amounts, linear analytical curves were found in the nearly two orders of magnitude mass ranges. Changes of the CaCl2 matrix concentration (loaded amount of 2–10 μg Ca) resulted in less than 5% changes in MS signals of 5 elements (each below 1 ng) and OES signals of 22 analytes (each below 15 ng). Exceptions were Pb (ICP-MS) and Cd (ICP-OES), where the sensitivity increase by Pd + Mg modifier was much larger compared to other elements studied. The general conclusions suggest that quantitative analysis with the use of ETV sample introduction requires matrix matching or matrix replacement by appropriate chemical modifier to the specific concentration ranges of analytes. This is a similar requirement to that claimed also by the most commonly used pneumatic nebulization of solutions, if samples with high matrix concentration are concerned.  相似文献   

19.
The intensity of individual gold nanoparticles with nominal diameters of 80, 100, 150, and 200 nm was measured using single-particle inductively coupled plasma-mass spectrometry (ICP-MS). Since the particles are not perfectly monodisperse, a distribution of ICP-MS intensity was obtained for each nominal diameter. The distribution of particle mass was determined from the transmission electron microscopy (TEM) image of the particles. The distribution of ICP-MS intensity and the distribution of particle mass for each nominal diameter were correlated to give a calibration curve. The calibration curves are linear, but the slope decreases as the nominal diameter increases. The reduced slope is probably due to a smaller degree of vaporization of the large particles.In addition to the degree of particle vaporization, the rate of analyte diffusion in the ICP is an important factor that determines the measured ICP-MS intensity. Simulated ICP-MS intensity versus particle size was calculated using a simple computer program that accounts for the vaporization rate of the gold nanoparticles and the diffusion rate and degree of ionization of the gold atoms. The curvature of the simulated calibration curves changes with sampling depth because the effects of particle vaporization and analyte diffusion on the ICP-MS intensity are dependent on the residence time of the particle in the ICP. Calibration curves of four hypothetical particles representing the four combinations of high and low boiling points (2000 and 4000 K) and high and low analyte diffusion rates (atomic masses of 10 and 200 Da) were calculated to further illustrate the relative effects of particle vaporization and analyte diffusion. The simulated calibration curves show that the sensitivity of single-particle ICP-MS is smaller than that of the ICP-MS measurement of continuous flow of standard solutions by a factor of 2 or more. Calibration using continuous flow of standard solution is semi-quantitative at best.An empirical equation is formulated for the estimation of the position of complete vaporization of a particle in the ICP. The equation takes into account the particle properties (diameter, density, boiling point, and molecular weight of the constituents of the particle) and the ICP operating parameters (ICP forward power and central channel gas flow rate). The proportional constant and exponents of the variables in the equation were solved using literature values of ICP operating conditions for single-particle inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES) measurements of 6 kinds of particles in 12 studies. The calculated position is a useful guide for the selection of sampling depth or observation height for ICP-MS and ICP-AES measurements of single particles as well as discrete particles in a flow, such as laser-ablated materials and airborne particulates.  相似文献   

20.
Lu CY  Yan XP 《Electrophoresis》2005,26(1):155-160
A new method for speciation analysis of two inorganic selenium species was developed by on-line coupling of capillary electrophoresis (CE) with hydride generation-atomic fluorescence spectrometry (HG-AFS) and on-line conversion of Se(VI) to Se(IV). Baseline separation of Se(VI) and Se(IV) was achieved by CE in a 50 cm x 75 microm inside diameter (ID) fused-silica capillary at -20 kV using a mixture of 15 mmol.L(-1) NaH2PO4 and 0.5 mmol.L(-1) cetyltrimethylammonium bromide (pH 7.5) as electrolyte buffer. Se(VI) was on-line reduced to Se(IV) by mixing the CE effluent with concentrated HCl. The precision (relative standard deviation, RSD, n=7) ranged from 0.7 to 1.3% for migration time, 6.4 to 3.7% for peak height response, and 5.9 to 6.1% for peak area for the two selenium species at the 500 microg.L(-1) (as Se) level. The detection limits were 33 and 25 microg.L(-1) (as Se) for Se(VI) and Se(IV), respectively. The recoveries of the two selenium species in five locally collected water samples ranged from 88 to 114%. The developed method was applied to speciation analysis of inorganic selenium species in spiked natural water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号