首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The voltammetric responses of chlorine in aqueous acid solutions have been explored using different carbon-based electrodes. Edge-plane pyrolytic graphite has more electrochemical reversibility than glassy carbon, basal-plane pyrolytic graphite, or boron-doped diamond electrodes. A significant reduction in the overpotential is observed on the edge-plane pyrolytic-graphite electrode in contrast with the other carbon-based electrode substrates. These results suggest that edge-plane pyrolytic graphite can be optimally used as the working electrodes in Clark-cell devices for low-potential amperometric gas sensing of Cl2.  相似文献   

2.
《Electroanalysis》2005,17(8):655-661
The first examples of using edge plane pyrolytic graphite electrodes for anodic and cathodic stripping voltammetry (ASV and CSV) are presented, notably the ASV of silver and the CSV of manganese. In the former example, detection limits for silver (based on 3σ) of 8.1 nM and 0.185 nM for 120 s and 300 s accumulation time, respectively, were achievable using the edge plane electrode, which were superior to those observed on glassy carbon, basal plane pyrolytic graphite and boron‐doped diamond electrodes. In the second example, a detection limit for manganese of 0.3 μM was possible which was comparable with that achievable with a boron‐doped diamond electrode but with an increased sensitivity. Comparison of the edge plane pyrolytic graphite electrode with boron‐doped diamond electrodes reveals that the edge plane electrode has comparable detection limits and sensitivities whilst exhibiting a lower signal‐to‐noise ratio and large potential window for use in trace analysis suggesting boron‐doped diamond can be conveniently replaced by edge plane pyrolytic graphite as an electrode material in many applications.  相似文献   

3.
Recent advances in electrochemical detection in capillary electrophoresis   总被引:3,自引:0,他引:3  
Baldwin RP 《Electrophoresis》2000,21(18):4017-4028
Recent advances in the design and application of electrochemical (EC) detection systems in capillary electrophoresis (CE) are reviewed, with the objective of providing the nonelectrochemist with a state-of-the-art picture of CEEC instrumentation and an overview of the principal analytes for which CEEC is best suited. The detection schemes considered here include those based both on amperometry and on potentiometry as both kinds of EC systems are being actively developed in CE and have the potential for broad application in analysis. Over the three-year period covered by this review, an important direction that CEEC has taken is the construction of more complex electrode systems beginning with the use of multiple EC electrodes and culminating with the adaptation of EC detection to microfabricated "lab-on-a-chip" analysis devices. In addition, CEEC applications have now grown to include a broad variety of inorganic, organic, and biochemical analytes and samples.  相似文献   

4.
《Electroanalysis》2005,17(17):1529-1533
The direct electrochemical oxidation of ascorbic acid at an edge plane pyrolytic graphite electrode (EPPG) is investigated and compared with other common carbon‐based electrodes, specifically glassy carbon, boron doped diamond and basal plane pyrolytic graphite. It is found that the EPPG electrode shows a significantly higher degree of electrochemical reversibility than the other electrode substrates giving rise to an analytically optimized limit of detection and sensitivity of 7.1×10?5 M and 0.065 A M?1 respectively.  相似文献   

5.
Ali Özcan 《Electroanalysis》2014,26(7):1631-1639
In this study, pencil graphite electrodes were activated electrochemically in the presence of different supporting electrolytes and used for the selective and sensitive determination of bisphenol A (BPA) in water samples. Synergistic effects of both LiClO4 and NaOH supporting electrolytes on the performance of the electrochemically treated pencil graphite electrode (ETPGE) were demonstrated in the oxidation of BPA. The electrochemical behavior of BPA on the ETPGE showed two irreversible oxidation peaks at 0.744 V and 0.877 V (vs. SCE). The detection limit was determined to be 3.1 nM. This single‐use electrode is a very promising candidate to overcome the passivation problems arising from the oxidation of BPA. The analytical application of the ETPGE was performed in tap and river water samples.  相似文献   

6.
Rechargeable lithium-ion batteries (LIBs) dominate the energy market, from electronic devices to electric vehicles, but pursuing greater energy density remains challenging owing to the limited electrode capacity. Although increasing the cut-off voltage of LIBs (>4.4 V vs. Li/Li+) can enhance the energy density, the aggravated electrolyte decomposition always leads to a severe capacity fading and/or expiry of the battery. Herein, a new durable electrolyte is reported for high-voltage LIBs. The designed electrolyte is composed of mixed linear alkyl carbonate solvent with certain cyclic carbonate additives, in which use of the ethylene carbonate (EC) co-solvent was successfully avoided to suppress the electrolyte decomposition. As a result, an extremely high cycling stability, rate capability, and high-temperature storage performance were demonstrated in the case of a graphite|LiNi0.6Co0.2Mn0.2O2 (NCM622) battery at 4.45 V when this electrolyte was used. The good compatibility of the electrolyte with the graphite anode and the mitigated structural degradation of the NCM622 cathode are responsible for the high performance at high potentials above 4.4 V. This work presents a promising application of high-voltage electrolytes for pursuing high energy LIBs and provides a straightforward guide to study the electrodes/electrolyte interface for higher stability.  相似文献   

7.
《Analytical letters》2012,45(12):603-611
Abstract

A silicone rubber based graphite electrode has been used as an indicator electrode for potentiometric acid-base titrations. The electrode potential changes an average of 30 mV per pH-unit. If the electrodes are pretreated with a solution of an oxidant before use, the pH-sensitivity is increased. The electrode can be used in both aqueous and non-aqueous solutions. A measuring cell, composed of a silicone rubber based graphite electrode of small surface area and a chloride-selective reference electrode, can be used for acid-base titrations in the micro range.  相似文献   

8.
石墨毡电极是组成钒电池的关键材料,其较低的电化学活性是造成钒电池功率密度较低的关键因素之一. 本论文采用一种简便的石墨毡电极分步氧化活化法,先将石墨毡在高锰酸钾溶液中进行氧化,后置于活化溶液中激发其反应活性. 通过对处理后的石墨毡进行循环伏安、交流阻抗测试、XPS以及SEM表征,发现氧化时间和活化溶液组成是影响电极性能的因素,在本文中,先经过3天氧化时间,后在配比为3:1的活化溶液中处理的电极,较其他方法处理的电极,电荷传递电阻明显降低,其与溶液之间的接触电阻最低,为7.33 Ω·cm 2,氧化还原峰值比更接近于1,有效提高了反应的活性与可逆性,经X射线光电子能谱分析发现性能提高的原因与表面含氧官能团数目增加有关. 单电池性能测试结果进一步证实,利用该方法处理的石墨毡为电极的单电池,较未经处理的电池相比性能更优,有更高的放电容量和能量效率,在100 mA·cm -2电流密度下,能量效率较未处理电极高出7.47%. 与热处理法、酸处理法及电化学氧化法相比较,该方法不需要辅助设备,不消耗能源.  相似文献   

9.
Electrochemical properties of new electrode material—compact of boron-doped synthetic diamond—is studied for the first time. Cylindrical samples 3.5–4 mm in diameter and 2.5 mm in height were obtained by thermobaric processing of graphite–boron carbide mixtures in the diamond thermodynamic stability region (at the pressure of 8–9 GPa and temperature of ~2500 K). Their electrode behavior is studied using cyclic voltammetry and electrochemical impedance spectroscopy techniques. The cyclic voltammograms of the compact samples showed that their electrode characteristics are similar to those of traditional thin-film diamond electrodes obtained by the chemical vapor deposition (CVD) technique. In particular, they demonstrate rather wide potential window, low background current in indifferent electrolytes, and good reproducibility. It can be concluded that the diamond compacts practically are not inferior to the thin-film CVD-diamond electrodes and can serve as indicator electrodes, e.g., in electroanalysis. At the same time their compact form may be a convenience in the designing of electrolyzers and other electrochemical devices.  相似文献   

10.
Antimony is an element of significant environmental concern, yet has been neglected relative to other heavy metals in electroanalysis. As such very little research has been reported on the electroanalytical determination of antimony at unmodified carbon electrodes. In this paper we report the electrochemical determination of Sb(III) in HCl solutions using unmodified carbon substrates, with focus on non-classical carbon materials namely edge plane pyrolytic graphite (EPPG), boron doped diamond (BDD) and screen-printed electrodes (SPE). Using differential pulse anodic stripping voltammetry, EPPG was found to give a considerably greater response towards antimony than other unmodified carbon electrodes, allowing highly linear ranges in nanomolar concentrations and a detection limit of 3.9?nM in 0.25?M HCl. Furthermore, the sensitivity of the response from EPPG was 100 times greater than for glassy carbon (GC). Unmodified GC gave a comparable response to previous results using the bare substrate, and BDD gave an improved, yet still very high limit of detection of 320?nM compared to previous analysis using an iridium oxide modified BDD electrode. SPEs gave a very poor response to antimony, even at high concentrations, observing no linearity from standard additions, as well as a major interference from the ink intrinsic to the working electrode carbon material. Owing to its superior performance relative to other carbon electrodes, the EPPG electrode was subjected to further analytical testing with antimony. The response of the electrode for a 40?nM concentration of Sb(III) was reproducible with a mean peak current of 1.07?µA and variation of 8.4% (n?=?8). The effect of metals copper, bismuth and arsenic were investigated at the electrode, as they are common interferences for stripping analysis of antimony.  相似文献   

11.
单链脱氧核糖核酸在石墨电极表面固定化的研究   总被引:14,自引:3,他引:14  
用5%(V/V)3-氨基丙基三乙氧基硅烷(PrNH2硅烷Ⅱ)在石墨电极表面硅烷化以导入氨基(-NH2),然后用乙基-(3-二甲基丙基)碳二亚胺盐要卤)EDC)关活化剂,将单链DNA(共价固定在石墨电极表面。采用显微分光光度法、红外光谱法和电化学方法对电极表面的ssDNA层进行了表征,并用紫外-可见光谱法对电极表面固定化ssDNA的杂交特性进行了研究。结果表明,ssDNA可以比较均匀地固定在石墨电极  相似文献   

12.
Pyrolytic carbon films (PCFs) were prepared by chemical vapor deposition (CVD) at different deposition temperatures. As an example of using PCF electrode in electroanalysis, the direct electrooxidation of ascorbic acid (AA) at the PCF electrode was investigated and compared with common carbon‐based electrodes such as glassy carbon (GC), edge plane pyrolytic graphite (EPPG), and basal plane pyrolytic graphite (BPPG) electrodes. It was found that the PCF electrodes prepared under deposition temperatures higher than 1050 °C showed a higher sensitivity and lower overpotential compared to the other carbon electrodes. The electrode was successfully applied for determination of AA in real samples.  相似文献   

13.
Solid asymmetric electrochemical capacitors (EC) using polyvinyl alcohol (PVA)–heteropoly acid (HPA) electrolytes and RuO2–graphite electrodes were developed. The devices were about 0.2 mm thick and had a working voltage window of 0–1.5 V, 50% wider than that of any proton-conducting symmetric EC. Pseudocapacitance from HPA contributes to the total capacitance of the asymmetric EC within a certain potential window. The PVA–HPA polymers have been proven to function both as electrolyte and as pseudocapacitive electrode material in EC cells.  相似文献   

14.
Li insertion–deinsertion into composite graphite electrodes, comprising synthetic graphite flakes (6 μm average size), polyvinylidene difluoride binder (PVdF), and copper current collectors, in commonly used alkyl carbonate solutions were studied by in situ atomic force microscopy (AFM). In this study, we were able to probe by in situ AFM the behavior of practical, composite graphite electrodes in ethylene carbonate–dimethyl carbonate (EC–DMC) solutions containing salts such as LiAsF6 and LiPF6 during entire lithiation–delithiation cycles. These in situ micro/nanomorphological studies could probe surface film formation on the graphite particles, as well as periodic volume changes in the graphite flakes during Li insertion–deinsertion cycles. These cyclic volume changes can explain the capacity fading of graphite electrodes upon prolonged cycling, in Li-ion batteries. While the overall morphology of these electrodes remains steady upon cycling in the appropriate solutions (in which the Li–C electrodes are efficiently passivated), there is a continuous problem in the extent of accommodation of the small volume changes in the graphite particles upon lithiation–delithiation, by the surface films. It is suggested that graphite electrodes fail during prolonged cycling due to small scale, continuous reactions of the active mass with solution species, which gradually increase their impedance and decrease the content of the lithium stored in the electrodes.  相似文献   

15.
A novel flow-injection amperometric method was proposed for the sensitive and enzymeless determination of hydrogen peroxide based on its electrocatalytic reduction at a palladium nanoparticle-modified pretreated pencil graphite electrode in a laboratory-constructed electrochemical flow cell. Cyclic voltammograms of the unmodified and modified electrodes were recorded in pH 7.0 phosphate buffer containing 0.10 M KCl at a scan rate of 50?mV s?1 for the investigation of electrocatalytic reduction of hydrogen peroxide at the palladium nanoparticle-modified pretreated pencil graphite electrode. Cyclic voltammograms of the pretreated pencil graphite electrode revealed an irreversible oxidation peak and a weak reduction peak of hydrogen peroxide at +1100?mV and –450?mV vs. an Ag/AgCl/KCl saturated reference electrode. However, the reduction of hydrogen peroxide was observed at –100?mV with an increase in current in the cyclic voltammograms of the palladium nanoparticle-modified pretreated pencil graphite electrode compared to the unmodified electrode. These results indicate that the palladium nanoparticle-modified pretreated pencil graphite electrode exhibits efficient electrocatalytic activity for the reduction of hydrogen peroxide. A linear concentration range was obtained between .01 and 10.0?mM hydrogen peroxide with a detection limit of 3.0 µM from flow injection amperometric current–time curves recorded in pH 7.0 phosphate buffer at –100?mV and a 2.0?mL min?1 flow rate. The novelty of this work relies on its use of a laboratory-constructed flow cell constructed for the pencil graphite electrode using these inexpensive, disposable, and electrochemically reactive modified electrodes for the amperometric determination of hydrogen peroxide in a flow injection analysis system.  相似文献   

16.
《Analytical letters》2012,45(15):2444-2459
Abstract

Polymeric membrane electrodes (PMEs) and coated graphite electrodes (CGEs) containing 1,3,4-trisubstituted-2-azetidinone derivatives as ion carriers are reported here for bismuth(III) ion selectivity. These electrodes exhibited Nernstian response for Bi3+ ions over a wide concentration range (5.0 × 10?7 M to 1.0 × 10?1 M for CGE) with a lower detection limit of 3.98 × 10?7 M (for CGE) and wide pH range (1.3–5.0). Compared to polymeric membrane electrode, the coated graphite electrode has shown better selectivity for Bi3+ ions with respect to common metal ions. Proposed electrodes have been used for the estimation of Bi3+ ions in pharmaceutical and glass samples.  相似文献   

17.
Recently, it was shown that electrochemical methods can be used for analysis of poorly water-soluble proteins and for study of their structural changes and intermolecular (protein–ligand) interactions. In this study, we focused on complex electrochemical investigation of recombinant protein FTT1103, a disulfide oxidoreductase with structural similarity to well described DsbA proteins. This thioredoxin-like periplasmic lipoprotein plays an important role in virulence of bacteria Francisella tularensis. For electrochemical analyses, adsorptive transfer (ex situ) square-wave voltammetry with pyrolytic graphite electrode, and alternating-current voltammetry and constant-current chronopotentiometric stripping analysis with mercury electrodes, including silver solid amalgam electrode (AgSAE) were used. AgSAE was used in poorly water-soluble protein analysis for the first time. In addition to basic redox, electrocatalytic and adsorption/desorption characterization of FTT1103, electrochemical methods were also used for sensitive determination of the protein at nanomolar level and study of its interaction with surface of AgSA microparticles. Proposed electrochemical protocol and AgSA surface-inhibition approach presented here could be used in future for biochemical studies focused on proteins associated with membranes as well as on those with disulfide oxidoreductase activity.  相似文献   

18.
High ordered mesoporous materials (SBA-15) modified with Al and/or B and Pt nanoparticles (Pt NPs) were used for preparing modified graphite paste electrodes (Pt/M−SBA-15-GPE, where M=Al−, B− or Al−B−) and applied for paracetamol (PA) detection. The electrodes were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Square wave voltammetry (SWV) technique was used to obtain the analytical parameters for PA detection. The acquired values of electrochemical and analytical parameters recommend the mesoporous compound containing Pt NPs to be used as composite electrode material for PA detection in real samples.  相似文献   

19.
An easy to build potentiometric stripping analysis system for heavy metal determinations (Zn, Cd, Pb, Cu) is described which reaches good sensitivity and precision. Main components are an IBM compatible computer, an ADDA-conversion card and two selfmade electrodes, so it can be realized for one tenth of the price of complete commercial systems. A graphite pencil lead covered with a Hg-film is used as working electrode and a Ag/AgCl electrode as a combined reference/counter electrode. Reproducibility and calibration measurements are reported, heavy metal determinations on soil samples are compared with AAS results.  相似文献   

20.
The electrocatalytic oxidation of oxalate at several carbon based electrodes including basal plane (BPPG) and edge plane (EPPG) pyrolytic graphite and glassy carbon (GC) electrode, was studied. The electrodes were examined for the sensing of oxalate ions in aqueous solutions and all three electrodes showed a response to oxalate additions. The peak of oxalate oxidation at BPPG electrode appeared at lower potential, +1.13 V vs. SCE, than at EPPG (+1.20 V vs. SCE) and GC electrode (+1.44 V vs. SCE). Oxalate oxidation at BPPG electrode was studied in more details for response characteristics (potential and current), effects of pH, temporal characteristics of response potential and current. The results indicated that oxalate oxidation proceeds as two‐electron process at the BPPG electrode with a transfer coefficient β and a diffusion coefficient D evaluated to be 0.45 and 1.03 (±0.04)×10?5 cm2 s?1 respectively. The BPPG electrode was found to be suitable for oxalate determination in aqueous media showing linear response to oxalate concentration with a sensitivity of 0.039 AM?1 and a limit of detection of 0.7 μM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号