首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and accurate spectrophotometric method for determination of trace amounts of silver ion in tap and wastewater solution and photographic solutions has been described. The spectrophotometric determination of silver ion using 2-mercaptobenzoxazole (MBO) in the presence of Triton X-100 as nonionic surfactant has been carried out. The Beer's law is obeyed over the concentration range of 0.1-9.0 microg mL(-1) of Ag+ ion with the detection limits of 1.6 ng mL(-1). The influence of type and amount of surfactant, pH, complexation time and amount of ligand on sensitivity of method were optimized. Finally the repeatability, accuracy and the effect of interfering ions on the determination of silver ion were evaluated. There is a good agreement between results of proposed method and atomic absorption spectrometry.  相似文献   

2.
Highly sensitive and interference-free sensitized spectrophotometric method for the determination of Ni(II) ions is described. The method is based on the reaction between Ni(II) ion and benzyl dioxime in micellar media in the presence of sodium dodecyl sulfate (SDS). The absorbance is linear from 0.1 up to 25.0 microg mL-1 in aqueous solution with repeatability (RSD) of 1.0% at a concentration of 1 microg mL-1 and a detection limit of 0.12 ng mL-1 and molar absorption coefficient of 68,600L mol-1 cm-1. The influence of reaction variables including type and amount of surfactant, pH, and amount of ligand and complexation time and the effect of interfering ions are investigated. The proposed procedure was applied to the determination of trace amounts of Ni(II) ion in tap water, river water, chocolate and vegetable without separation or organic solvent extraction.  相似文献   

3.
Hanna WG 《Talanta》1999,50(4):809-818
The complexation of para-Cl-phenylazo-R-acid azo dye with Pd(II) has been studied spectrophotometrically. Protonation constant (pK(a)) of the ligand has been calculated and the stability conditional constants of para-Cl-phenylazo-R-acid ligand with palladium ion has been determined at a constant temperature (25.0 degrees C), where the molar ratio of this complex is 1:1 (metal:ligand) with logbeta(1)=3.75, and 1:2 with logbeta(2)=8.55. Solid complex of para-Cl-phenylazo-R-acid has been prepared and characterized on the basis of elemental analysis and FTIR spectral data. A procedure for the spectrophotometric determination of Pd(II) using para-Cl-phenylazo-R-acid as a new azo chromophore is proposed where it is rapid, sensitive and highly specific. Beer's law was obeyed in the range 0.50-10.00 ppm at pH 5.0-6.0 to form a violet-red complex (epsilon=7.7 x 10(4) l(-1) mol(-1) cm(-1) at lambda(max)=560 nm). Metal ions such as Cu(II), Cr(III), La(III), Yb(III), Y(III), and Rh(III) interfere with the complex. Ammonium salt of trimellitic acid is used to precipitate some of the interfering ions and a scheme for separation of Pd(II) from a synthetic mixture similar in composition to platinum ore or deposit was made.  相似文献   

4.
Singh HB  Agnihotri NK  Singh VK 《Talanta》1999,48(3):623-631
A sensitive derivative spectrophotometric method using 1-nitroso-2-naphthol has been developed for determination of trace amounts of cobalt in the presence of a neutral surfactant. Photometric parameters, viz., lambda(max), molar absorption coefficient and analytical sensitivity of the complex formed in micellar media are 420 nm, 3.18x10(4) l mol(-1) cm(-1) and 2.05 ng ml(-1), respectively. Beer's law holds from 0.20 to 3.0 mug ml(-1) of the analyte concentration. The method has a high sensitivity with a detection limit of 1.68 ng ml(-1). A selective determination of cobalt in presence of copper(II) or iron(III) using derivative spectral profiles and without any masking or pre-separation is also reported. Samples of drugs and standard alloys analysed by the proposed method yielded results comparable to those obtained using recommended procedures.  相似文献   

5.
Zhao Y  Han G 《Talanta》1994,41(8):1247-1250
A spectrophotometric procedure is suggested for the determination of Cr(III). The reaction between Cr(III) and 2-(5-bromo-2-pyridylazo)-5-dimethylaminophenol is accelerated by sodium dodecyl sulphate(SDS), sodium benzoate causes a further increase in the absorbance of the chelate. The optimum pH range for the reaction is 5-5.8(benzoate buffer). The chelate exhibits maximum absorbance at 590 nm, obeys Beer's law over the concentration range 0.02-0.56 microg/ml of Cr(III), has molar absorptivity of 7.8 x 10(4) 1. mol(-1) cm(-1) and a Sandell sensitivity of 0.66 ng/cm. The metal to ligand ratio is 1:2 in the absence of SDS and 1:1 in its presence. A procedure for the determination of Cr(III) and Cr(VI), when present together, is described. The method has been applied to the analysis of Cr(III) in tap water.  相似文献   

6.
A simple and sensitized spectrophotometric method for the determination of trace amounts of beryllium has been described. The method is based on the formation of a ternary complex by the reaction of beryllium with haematoxylin in the presence of micellar medium (cationic surfactant, cetyltrimethylammonium bromide). The ternary complex of beryllium has a maximum absorbance at 592 nm and showed an excellent sensitivity (molar absorption coefficient of 7.07 x 10(4)L mol(-1)cm(-1) and the Sandell's sensitivity being 1.27 x 10(-4) microg cm(-2)) and reproducibility (within-day precision: R.S.D.相似文献   

7.
Aluminum is the third most abundant metal in the Earth’s crust. Despite its ubiquitous nature it is present in small amount in living organisms. Aluminum toxicity has been implicated in the pathogenesis of renal distinct clinical syndromes, including progressive and fatal encephalopathy and bone diseases. In the present study, Al was selected for the analysis by complexometric method. This method was based on the formation of a red colored ternary complex by the reaction of Aluminum with Aluminon (Aurin tricarboxylic acid triammonium salt) in the presence of micellar medium. The ternary complex of Aluminum with the surfactant Triton X-100 shows a maximum absorbance at 530 nm wavelength at pH 4.0 while with the sodium dodecyl sulfate it shows a maximum absorbance at 525 nm and at pH 5.0. The reaction was proceeded by the variation in pH and concentrations of surfactants, aluminon, aluminum. Their effects on the reaction of aluminum with aluminon complex in micellar media were recorded by UV-visible spectrophotometer. The reaction was found to be extremely rapid at room temperature. The system obeys Lambert Beer’s law between 0.24 and 21.74 μg/mL concentrations with Triton X-100. The values of slope, intercept and correlation coefficients were 0.07, 0.348 and 0.989, respectively. The concentration varied between 0.24 and 24.14 μg/mL with sodium dodecyl sulfate and the values of slope, intercept and correlation coefficients were 0.029, 0.148 and 0.962, respectively. The foreign ion effect was also tested by keeping the constant concentration of metal ion and determining its concentration in the presence of different foreign ions. The method was also applied for the determination of Al(III) in pharmaceutical formulations and water samples, which showed an excellent resemblance between reported and obtained results.  相似文献   

8.
A very simple and selective spectrophotometric method for simultaneous determination of Co(II) and Ni(II) by 1-(2-pyridylazo) 2-naphthol (PAN), in micellar media, using H-point standard addition method (HPSAM) is described. The ligand and its metal complexes (Co(II)-PAN and Ni(II)-PAN) were made water-soluble by the neutral surfactant Triton X-100, and therefore, no extraction with organic solvents was required. Formation of both the complexes was complete within 10 min at pH 9 (adjusted by ammonia buffer). The linear range was 0.10-2.00 microg ml(-1) for Co(II) and 0.05-1.50 microg ml(-1) for Ni(II). The relative standard deviation (R.S.D.) for the simultaneous determination of 0.50 microg ml(-1) each of Co(II) and Ni(II) was 2.32 and 3.13%, respectively. Interference effects of common anions and cations were studied and the method was applied to simultaneous determination of Co(II) and Ni(II) in alloy samples. The method was compared with derivative spectrophotometric method.  相似文献   

9.
The complexation of chromium by different flavonoid dyes in micellar media has been studied, in particular the reaction between chromium and quercetin. Micellar effects, the reaction pathway proposed and the application of the method to the determination of Cr(VI) and Cr(VI) + Cr(III) mixtures are discussed.  相似文献   

10.
Zeng Z  Xu Q 《Talanta》1992,39(4):409-413
The synthesis of 5-(4-sodium sulphonatephenylazo)-8-aminoquinoline (SPAQ) is described, and a simple, rapid, selective and sensitive new spectrophotometric method for determination of gold is developed. SPAQ reacts with gold(III), and in the presence of cetyl trimethyl ammonium bromide cationic surfactant and upon making the solution alkaline, forms a blue-green 1:3 (metal:ligand) with an absorption maximum at 605 nm. Beer's law is obeyed over the concentration range 0-2 microg/ml gold. The molar absorptivity and Sandell's sensitivity of the method are 1.48 x 10(5) 1.mole(-1).cm(-1) and 0.0013 microg/cm(2), respectively. The interference of various ions has been studied and the method has been used for the determination of microamounts of gold in ores and anode slimes.  相似文献   

11.
研究并建立了非离子表面活性剂聚乙二醇辛基苯基醚(Tx-100)胶束增敏离子缔合物分光光度法测定微量银的分析方法。实验结果表明,在表面活性剂存在下,方法的灵敏度比未增敏体系提高了近5倍,络合物稳定性也大大增加。方法的最佳酸度是pH=4.0,银浓度在0~0.4mg·mL-1符合比耳定律。以EDTA为掩蔽剂,只有Br-、I-、CN-、S2-有干扰。方法用于人工合成样品和显影废液中微量银的分析,准确度和精密度令人满意。  相似文献   

12.
《Analytical letters》2012,45(12):997-1008
Abstract

The spectrophotometric method for the determination of cyanide, which is based on the reaction of cyanide ion with 5,5′-dithiobis(2-nitrobenzoic acid) to displace the corresponding absorbing thiol anion, has been reinvestigated using an aqueous cetyltrimethylammonium bromide micellar reaction medium. The rate of the analytical reaction is increased considerably in the presence of the cationic surfactant. Thus, the time required for the spectrophotometric determination of cyanide ion in the 0.18 – 2.80 μg/ml range using this procedure is decreased from 25 minutes to 1 – 3 minutes.  相似文献   

13.
Wei Q  Duan C  Wang J  Ma H  Du B 《Annali di chimica》2006,96(7-8):451-461
A new catalytic kinetic spectrophotometric method for the determination of trace amount of chromium (VI) in microemulsion medium has been developed. The method is based on the catalytic effect of chromium (VI) on the oxidation of nuclear fast red in the presence of Tween-80 microemulsion and HAc-NaAc buffer solution (pH = 5.2). The linear ranges are in the range of 0 approximately 0.0480 microg mL(-1) of Cr (VI) at 528 nm and the detection limit is 1.56x10(-9)g mL(-1). The method has been applied in determination of Cr (VI) in water and food samples with satisfactory results. The relative standard deviation is less than 4.6 % and the recovery is 93.5 approximately 104 %.  相似文献   

14.
A partial least-squares regression (PLS) was developed for the simultaneous spectrophotometric determination of aluminum and beryllium in geochemical samples by xylenol orange as the chromogenic reagent in water media and in micellar media. The effects of pH, xylenol orange concentration and surfactant concentration on the complexes formation reactions were studied. In the absence of surfactant the complex color development takes place at 2 h after mixing the reagents. By using CTAB as micellar media the complexes formation was improved and the rate of the complexation reactions increased. By using PLS-1 algorithm satisfactory results were obtained. The proposed procedure showed to be useful for prediction of Al and Be values from 0.1 to 1.0 mg L(-1).  相似文献   

15.
The H-point standard addition method (HPSAM), based on spectrophotometric measurements for simultaneous determination of beryllium and aluminium, is described. This method is based on the difference between their rates of reactions with Chrome Azurol S (CAS) in cetyltrimethylammonium bromide (CTAB) micellar media. The results showed that beryllium and aluminium could be determined simultaneously in the ranges of 10-200 and 10-300 ng mL(-1), respectively. Under working conditions, the proposed method was successfully applied to the simultaneous determination of beryllium and aluminium in environmental, geochemical and alloy samples.  相似文献   

16.
A simple and reliable method has been developed for the determination of uranium(VI). The method is based on the separation and preconcentration of uranium(VI) using a column packed with 8-hydroxyquinoline immobilized on surfactant coated alumina prior to its spectrophotometric determination with arsenazo III. The effect of pH, sample flow rate and volume, elution conditions, and foreign ions on the sorption of uranium(VI) has been investigated. A preconcentration factor of 200 was achieved by passing 1000 mL of sample through the column. The relative standard deviation for 10 replicate analyses at the 100 ng/mL level of uranium(VI) was 2.1% and the detection limit was 0.12 ng/mL. The method was success-fully applied to the determination of uranium in natural water samples. The accuracy was assessed through recovery experiments and the analysis of a certified reference material.  相似文献   

17.
A simple and highly sensitive spectrophotometric method for the determination of anthracycline anticancer agents, such as Daunorubicin hydrochloride (DAU), was established by using aluminum(III) and Chromazurol S (CAS) in a nonionic surfactant micellar medium. In the case of determination of DAU, the apparent molar absorptivity was 1.3 x 10(5) dm3 mol(-1) cm(-1) at 615 nm. Beer's law was obeyed in the concentration range of 0.028 - 2.82 microg ml(-1) for DAU. Owing to no need for solvent extraction, this method could be applied to assays of DAU and related drugs in pharmaceutical preparations.  相似文献   

18.
A new rapid, selective and sensitive on-line microwave flow injection-kinetic method was developed for spectrophotometric determination of micro amounts of Ir(III), based on its catalytic effect on the m-acetylchlorophosphonazo (CPA-mA) and KIO(4) reaction in NaOH media. An on-line microwave oven was employed to accelerate the reaction. The reaction was followed spectrophotometrically by measuring the decrease of the absorbance of CPA-mA at 580 nm. The effect of five variables for the determination of Ir(III) was optimized by means of a multilayer artificial neural network using extended delta-bar-delta (EDBD) algorithms. Under the optimum experimental conditions, Ir(III) could be determined in the range 0.060-0.60 micro gZZZ;mL(-1) with detection limit of 0.02 micro gZZZ;mL(-1) and the sampling frequency of 34 h(-1). The proposed method was applied to the determination of micro amounts of Ir(III) in refined ore and secondary alloy with the recoveries from 91.4% to 109%.  相似文献   

19.
Baranowska I  Barszczewska K 《Talanta》1992,39(9):1205-1208
Volumetric and spectrophotometric methods for molybdenum determination based on reaction with 2,2'-biquinoxalyl (2,2'-BQx) in concentrated hydrochloric acid media have been developed. Absorption spectra of the 1,1'-dihydro 2,2'-biquinoxalylene complex shows the most intensive absorption band at 685 nm with molar absorptivity = 3.3 x 10(4) 1. mole(-1). cm(-1). The compound is characterized by good durability to high temperatures and concentrated acid media. The mentioned indicator gives distinct colour changes at the titration end-point. The spectrophotometric method for molybdenum determination is based on the use of the difference in absorbance between the oxidized and reduced forms of 2,2'-BQx. The indicator is reduced with Sn(II) and then part of it is reoxided as a result of addition of Mo(VI). The difference in absorbance between the blank determination and molybdenum sample increases linearily in the concentration range 0.2-2.0 mug Mo/cm(3). 2,2'-Biquinoxalyl was used as an indicator in the volumetric method for the determination of molybdenum concentrations in steel alloy. The interfering ions FE(III) and Cr(III) are easily eliminated as the precipitate of hydroxides. The mineral acids, hydrochloric sulphuric and perchloric acids, have been tested as reaction media.  相似文献   

20.
阳离子表面活性剂增敏催化光度法测定痕量铬(Ⅵ)   总被引:3,自引:0,他引:3  
基于存在增敏剂十六烷基三甲基溴化铵,铬(Ⅵ)催化过氧化氢氧化胭脂红酸的反应,拟定了测定痕量铬(Ⅵ)的新催化光度法。本法由于添加了十六烷基三甲基溴化铵,灵敏度提高3.3倍,测定铬(Ⅵ)含量的线性范围为0.005~0.16μg/mL,检出限为1.0×10-3μg/mL,相对标准偏差为0.5%(n=9),可用于测定水样中的铬(Ⅵ)。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏