首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
A forced degradation study was successfully applied for the development of a stability-indicating assay method for the determination of atazanavir in presence of its degradation products. The method was developed and optimized by analyzing the forcefully degraded samples. Degradation of the drug was done under acidic, alkaline, oxidative, photolytic and thermal stress conditions. The proposed method was able to resolve all of the possible degradation products formed during the stress studies. The major impurities are generated in acidic and alkaline conditions. The product was found stable under thermal, photolytic and oxidative conditions. The developed method was validated for determination of atazanavir, and the method was found to be equality applicable to study the impurities formed during routine and forced degradation of atazanavir.  相似文献   

2.
The present paper describes the development of a stability indicating reversed phase column liquid chromatographic method for aripiprazole in the presence of its impurities and degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of aqueous hydrolysis, oxidative, photolytic and thermal stress degradation. The degradation of aripiprazole was observed under acid hydrolysis and peroxide. The drug was found to be stable to other stress conditions attempted. Successful separation of the drug from the synthetic impurities and degradation products formed under stress conditions was achieved on an Inertsil phenyl column using a mixture of 0.2% trifluoroacetic acid and acetonitrile (55:45, v/v). The developed LC method was validated with respect to linearity, accuracy, precision, specificity and robustness. The assay method was found linear in the range of 25–200 μg mL?1 with a correlation coefficient of 0.9999 and the linearity of the impurities were established from LOQ to 0.3%. Recoveries of the assay and impurities were found between 97.2 and 104.6%. The developed LC method for the related substances and assay determination of aripiprazole can be used to evaluate the quality of regular production samples. It can also be used to test the stability samples of aripiprazole. To the best of our knowledge, the validated stability indicating LC method which separates all the impurities disclosed in this investigation was not published elsewhere.  相似文献   

3.
4.
Macitentan (MAC) is a pulmonary arterial hypertension (PAH) drug marketed as a tablet and often has stability issues in the final dosage form. Quantitative determination of MAC and its associated impurities in tablet dosage form has not been previously reported. This study quantified impurities present in Macitentan tablets using a binary solvent-based gradient elution method using reversed phase-high performance liquid chromatography. The developed method was validated per International Conference on Harmonization (ICH) guidelines and the drug product was subjected to forced degradation studies to evaluate stability. The developed method efficiently separated the drug and impurities (48 min) without interference from solvents, excipients, or other impurities. The developed method met all guidelines in all characteristics with recoveries ranging from 85%-115%, linearity with r2 ≥ 0.9966, and substantial robustness. The stability-indicating nature of the method was evaluated using stressed conditions (hydrolysis:1 N HCl at 80℃/15 min; 1 N NaOH at 25℃/45 min; humidity stress (90% relative humidity) at 25℃ for 24 h, oxidation:at 6% (v/v) H2O2, 80℃/15 min, thermolysis:at 105℃/16 h and photolysis:UV light at 200 Wh/m2; Fluorescent light at 1.2 million luxh). Forced degradation experiments showed that the developed method was effective for impurity profiling. All stressed samples were assayed and mass balance was>96%. Forced degradation results indicated that MAC tablets were sensitive to hydrolysis (acid and alkali) and thermal conditions. The developed method is suitable for both assay and impurity determination, which is applicable to the pharmaceutical industry.  相似文献   

5.
The stability-indicating LC assay method was developed and validated for quantitative determination of cefoselis sulphate in the presence of degradation products formed during the forced degradation studies. An isocratic, RP-HPLC method was developed with C-18 (250 × 4.6 mm, 5 μm) column and 12 mM ammonium acetate-acetonitrile (95:5 V/V) as a mobile phase. The flow rate of the mobile phase was 1.0 mL min−1. Detection wavelength was 260 nm and temperature was 30°C. Cefoselis similarly to other cephalosporins was subjected to stress conditions of degradation in aqueous solutions including hydrolysis, oxidation, photolysis and thermal degradation. The developed method was validated with regard to linearity, accuracy, precision, selectivity and robustness. The method was applied successfully for identification and determination of cefoselis sulphate in pharmaceuticals and during kinetic studies.  相似文献   

6.
A simple and rapid reversed-phase liquid chromatographic method was developed for the related substances determination and quantitative evaluation of ziprasidone hydrochloride, which is used as an antipsychotic agent. Forced degradation studies were performed on bulk sample of ziprasidone hydrochloride using acid, base, oxidative hydrolysis, thermal stress and photolytic degradation. Mild degradation of the drug substance was observed during thermal stress and considerable degradation observed during base hydrolysis. The chromatographic method was fine tuned using the samples generated from forced degradation studies. Good resolution between the peaks corresponds to synthetic impurities and degradation products from the analyte were achieved on YMC Pack Pro C18 column using the mobile phase consists of a mixture of 0.05% v/v of phosphoric acid in water and acetonitrile. The stressed test solutions were assayed against the qualified working standard of ziprasidone hydrochloride and the mass balance in each case was close to 99.7% indicating that the developed method was stability-indicating. Validation of the developed method was carried out as per ICH requirements.  相似文献   

7.
The present study dealt with the forced degradation behaviour of rosuvastatin under ICH prescribed stress conditions. The drug was found to be labile under acid hydrolytic and photolytic conditions, while it was stable to base/neutral hydrolytic, oxidative and thermal stress. In total, 11 degradation products were formed, which were separated on a C-18 column using a stability-indicating method. LC-MS analyses indicated that five degradation products had the same molecular mass as that of the drug, while the remaining six had 18 Da less than the drug. Structure elucidation of all the degradation products was executed using sophisticated and modern structural characterization tools, viz. LC-MS/TOF, LC-MSn, on-line H/D exchange and LC-NMR. The degradation pathway and mechanisms of degradation of the drug were delineated. Additionally, in silico toxicity was predicted for all the degradation products using TOPKAT and DEREK software and compared with the drug. This study demonstrates a comprehensive approach of degradation studies during the drug development phase.
Figure
Degradation pathway of rosuvastatin  相似文献   

8.
A simple isocratic, RP-ultra-performance LC method was developed and validated for the determination of lacidipine, three process impurities formed during synthesis, and three degradation products present in drug substance and the drug product. An efficient chromatographic separation was achieved on an Acquity BEH C18 column using pH 4.5 ammonium acetate-acetic acid buffer-methanol (70 + 30, v/v) mobile phase. The monitoring wavelength was 240 nm, and the flow rate 0.25 mL/min. Forced degradation studies using acid, alkali, peroxide, water, heat, and light were conducted, and all impurities were separated. The method was validated successfully for specificity, precision, linearity, accuracy, LOD, LOQ, and robustness, according to International Conference on Harmonization guidelines. The linearity of the calibration curve for lacidipine and each impurity was found to be very good (r2 > 0.999). This method is shown to be suitable for analysis of lacidipine to evaluate the quality of drug substance and a drug product.  相似文献   

9.
We developed novel stability‐indicating HPLC method for simultaneous estimation of 14 impurities in excedrin tablet, a formulation with a combination of acetaminophen, aspirin, and caffeine. In addition, a new impurity that was generated through degradation of aspirin at high temperatures during the accelerated stability conditions was positively identified and confirmed, using liquid chromatography–mass spectrometry technique. The HPLC method was optimized using the Inertsustain C18, 250 × 4.6 mm, 5.0 μm column, employing simple gradient method. Forced degradation studies were performed under acidic, basic, oxidative and thermal conditions to prove the scope and stability‐indicating the nature of the method. The optimized method was validated as per the International Conference on Harmonization guidelines. The HPLC method showed linearity from LOQ concentration to 21 μg mL?1. Precision and intermediate precision values were <5% RSD. The validated HPLC method is currently applied for the routine testing of excedrin tablet formulations in quality control laboratories.  相似文献   

10.
A novel stability-indicating high-performance liquid chromatographic (HPLC) method was developed and validated for assay and determination of impurities of emtricitabine in drug substance. Emtricitabine was found to be degraded under acidic, alkaline, and oxidative stress conditions and to be more labile under oxidative conditions. The drug proved to be stable to dry heat and photolytic degradation. Resolution of major and minor degradation impurities was achieved on an Intersil ODS-3V column utilizing 10 mM sodium phosphate buffer and methanol (85:15) as mobile phase. Detection was at 280 nm. Validation studies were performed as per ICH recommended conditions. The developed method was found to be linear, accurate, specific, selective, precise, and robust.  相似文献   

11.
A novel and selective stability-indicating liquid chromatographic method has been developed and validated for the analysis of dimethindene maleate, the related substance 2-ethylpyridine, and three degradation products. Dimethindene maleate was subjected to forced degradation study by acid and basic hydrolysis, oxidation, and thermal decomposition. Three degradation products that were formed during the forced degradation study were separated from dimethindene using a Zorbax SB CN column (150 × 4.6 mm; 5 μm); cyanopropyl-bonded stationary phase was applied for the first time for the separation of dimethindene and its impurities. The proposed method was validated and was found suitable for quality control and stability tests of pharmaceuticals containing dimethindene maleate.  相似文献   

12.
NPC 1161C (+/-8-[(4-amino-1-methylbutyl)amino-5-(3,4-dichlorophenoxy)-6-methoxy-4-methylquinoline succinate]) is a novel investigational antimalarial drug of interest for its in vivo oral potency, activity against blood and tissue stage parasites, favorable toxicity profile, long duration of action, and utility in both prophylaxis and treatment models. The pharmaceutical development of NPC 1161C warranted the availability of an assay for the detection and quantification of the drug and its separation from the impurities and degradation products. A simple and rapid stability-indicating reversed-phase HPLC method was developed and validated according to ICH guidelines. The method was found to be linear, precise and accurate. It also proved to be selective in the presence of impurities and degradation products during forced degradation studies. The method was found to be robust by factorial experimental design and was well within the recommended parameters of system suitability testing. Degradants of the drug during stress studies were also identified using high resolution mass spectrometry.  相似文献   

13.

A novel and selective stability-indicating liquid chromatographic method has been developed and validated for the analysis of dimethindene maleate, the related substance 2-ethylpyridine, and three degradation products. Dimethindene maleate was subjected to forced degradation study by acid and basic hydrolysis, oxidation, and thermal decomposition. Three degradation products that were formed during the forced degradation study were separated from dimethindene using a Zorbax SB CN column (150 × 4.6 mm; 5 μm); cyanopropyl-bonded stationary phase was applied for the first time for the separation of dimethindene and its impurities. The proposed method was validated and was found suitable for quality control and stability tests of pharmaceuticals containing dimethindene maleate.

  相似文献   

14.
A validated specific stability indicating reversed-phase high-performance liquid chromatography method was developed for the quantitative determination of Amsacrine as well as its related substances determination in bulk samples, in presence of degradation products, and its process related impurities. Forced degradation studies were performed on bulk samples of Amsacrine as per International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human use (ICH) prescribed stress conditions using acid, base, oxidative, thermal stress, and photolytic degradation to show the stability indicating power of the method. Significant degradation was observed during basic hydrolysis, slight degradation was observed in oxidative and thermal stress, and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies and the impurity spiked solution. Good resolution between the peaks corresponds to process-related impurities and degradation products from the analyte were achieved on Inertsil ODS column using the mobile phase consists a mixture of 1.0% triethyl amine in 20 mM potassium dihydrogen orthophosphate, with pH adjusted to 6.5, with ortho phosphoric acid in water and acetonitrile using a simple linear gradient. The detection was carried out at wavelength 248 nm. The mass balance in each case was in between 99.4% to 99.9%, indicating that the developed method was stability-indicating. Validation of the developed method was carried out as per ICH requirements. The developed method was found to be suitable to check the quality of bulk samples of Amsacrine at the time of batch release and also during its stability studies.  相似文献   

15.
Macitentan (MCT) is an endothelin receptor antagonist used for the treatment of pulmonary arterial hypertension. In the present study, MCT was subjected to forced degradation as per ICH guidelines. The drug degraded extensively in acidic, basic as well as neutral hydrolytic conditions and seven degradation products (DPs) were formed. All these DPs were selectively separated using high-performance liquid chromatography (HPLC) with a stationary phase of Inertsil C18 column (150 × 4.6 mm, 5 μm) and a mobile phase consisting of gradient mixture of 0.02% trifluoroacetic acid (TFA) and acetonitrile (ACN). The developed HPLC method was transferred to LC–ESI–QTOF–MS/MS for identification of DPs. The final mass spectrometric conditions were optimized for better ionization of drug and DPs with optimum mass signal sensitivity. All the formed DPs were new and well separated with sufficient resolution. The developed HPLC method was validated as per ICH-guidelines and can be used in drug testing labs for determination of quality of MCT in bulk and finished formulations.  相似文献   

16.
A simple, fast, specific, stability-indicating, and precise reversed-phase liquid chromatographic method was developed for the determination of Cefdinir in its different dosage forms, i.e., capsules and suspensions. The method was developed and optimized by analyzing the placebo preparation, formulations, and degraded samples of the drug substance according to the International Conference on Harmonization. The proposed method can successfully separate the drug from degradation products formed under stress conditions along with pharmaceutical ingredients such as preservatives. The developed method was used successfully to determine Cefdinir in capsules and Insta-use suspensions. The developed method was found to be linear for a concentration range of 6-14 microg/mL. Average recoveries obtained with the method were 99.3 +/- 0.4 and 99.6 +/- 0.4% for Insta-use suspensions and capsules, respectively. The method was shown to be specific, precise, and robust.  相似文献   

17.
A validated, specific, stability-indicating reversed-phase liquid chromatographic method has been developed for quantitative analysis of moxifloxacin and its related substances in bulk samples and pharmaceutical dosage forms in the presence of degradation products and process-related impurities. Forced degradation studies were performed on bulk samples of moxifloxacin, in accordance with ICH guidelines, using acidic, basic, and oxidizing conditions, and thermal and photolytic stress, to show the stability-indicating power of the method. Significant degradation was caused by oxidative stress and by basic conditions; no degradation was observed under the other stress conditions. The method was optimized by analysis of the samples generated during the forced degradation studies and sample solutions spiked with the impurities. Good resolution between the analyte peak and peaks corresponding to process-related impurities and degradation products was achieved on a C18 column with a simple linear mobile phase gradient prepared from aqueous sodium dihydrogen orthophosphate dihydrate containing triethylamine, pH adjusted to 3.0 with orthophosphoric acid, and methanol. Detection was performed at 240 nm. Limits of detection and quantification were established for moxifloxacin and its process related impurities. When the stressed test solutions were assayed against moxifloxacin working standard solution the mass balance was always between 99.3 and 100.1%, indicating the method was stability-indicating. The method was validated in accordance with ICH guidelines, and found to be suitable for checking the quality of bulk samples of moxifloxacin at the time of release of a batch and during storage (long term and accelerated stability testing was conducted).  相似文献   

18.
A forced degradation study on glibenclamide was performed under conditions of hydrolysis, oxidation, dry heat, and photolysis and a high-performance column liquid chromatographic-ultraviolet (HPLC-UV) method was developed to study degradation behavior of the drug under the forced conditions. The degradation products formed under different forced conditions were characterized through isolation and subsequent infrared/nuclear magnetic resonance/mass spectral analyses, or through HPLC/mass spectrometric (HPLC/MS) studies. The drug degraded in 0.1 M HCI and water at 85 degrees C to a major degradation product, 5-chloro-2-methoxy-N-2-(4-sulfamoylphenyl)ethyl]benzamide (III), and to a minor product, 1-cyclohexyl-3-[[4-(2-aminoethyl)-phenyl]sulfonyl]urea (IV). Upon prolonged heating in the acid, the minor product IV disappeared, resulting in formation of 5-chloro-2-methoxy-benzoic acid (II) and an unidentified product (I). Heating of the drug in 0.1 M NaOH at 85 degrees C yielded II and IV as the major products and I and III as the minor products. The drug and the degradation products formed under different conditions were optimally resolved on a C18 column using ammonium acetate buffer (0.025 M, pH 3.5)-acetonitrile (45 + 55) mobile phase at a flow rate of 0.6 mL/min, with detection at 230 nm. The method was validated for linearity, precision, accuracy, and specificity. Limit of detection (LOD) and limit of quantitation (LOQ) values were also determined. The method could be successfully applied for simultaneous quantification of glibenclamide and the major product, III. The response of the method was linear in a narrow [0.4-10 micro/mL, correlation coefficient (r2) = 0.9982] and a wide (0.4-500 microg/mL, r2 = 0.9993) concentration range for glibenclamide, and in the concentration range of 0.025-50 microg/mL (r2 = 0.9998) for III. The method proved to be precise and accurate for both glibenclamide and III. It was specific for the drug and also selective for each degradation product, and LOQ values for the drug were 0.1 and 0.4 microg/mL, whereas those for III were 0.010 and 0.025 microg/mL, respectively.  相似文献   

19.
A gradient reversed-phase liquid chromatographic assay was developed for the quantitative determination of the non-steroidal anti-inflammatory drug valdecoxib. The developed method was also applicable to the determination of related substances in the bulk drug. Forced degradation studies were performed on bulk valdecoxib using acid (2.0 N hydrochloric acid), base (2.0 N sodium hydroxide), oxidation (6.0% v/v hydrogen peroxide), water hydrolysis, heat (60 °C) and photolysis. Mild degradation was observed using alkaline conditions and considerable degradation observed during oxidative stress. Chromatographic separation of process-related impurities and degradation products was achieved using a 5 micron Zorbax SB-CN LC column. The mobile phase consisted of aqueous potassium dihydrogen phosphate (pH 3.0) and acetonitrile. Stressed samples were assayed using the developed LC method and determination of the mass balance accounted for 99.5%, thus indicating the suitability of this stability-indicating method. Linearity, accuracy, precision and robustness have also been evaluated.  相似文献   

20.
The stability-indicating LC assay method was developed and validated for quantitative determination of cefcapene pivoxil in the presence of degradation products formed during forced degradation studies. An isocratic RP-HPLC method was developed with a Lichrospher RP-18 (250 mm × 4.6 mm, 5 μm) column and the mobile phase composed of 45 volumes of acetonitrile and 55 volumes of mixture composed of citric acid 10 mmol L?1 and potassium chloride 18 mmol L?1. The flow rate of the mobile phase was 1 mL min?1. Detection wavelength was 270 nm and temperature was 30 °C. Cefcapene pivoxil, similar to other cephalosporins, was subjected to stress conditions of degradation in aqueous solutions including hydrolysis, oxidation, and thermal degradation. The method was validated with regard to linearity, accuracy, precision, selectivity, and robustness. The method was applied successfully for the determination of cefcapene pivoxil during kinetic studies in aqueous solutions (pH and thermal degradation) and in solid state (oxidative, thermal, and radiolytic degradation).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号