首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, environmentally friendly and high efficient extraction method was proposed for the determination of five phthalates in aquatic products by gas chromatography combined with mass spectrometry detector (GC-MS). When this method was adopted, samples were pretreated by modified QuEChERS(quick, easy, cheap, effective, rugged and safe) method. An environmentally friendly extractant(ethanol aqueous solution) replaced toxic acetonitrile for extracting phthalates in the protein-matrix samples. Fluorescence quenching spectra of bovine serum albumin(BSA) with phthalates show that there was a high-affinity interaction between phthalate and protein, decreasing the extraction efficiency of phthalates from fish samples. However, in the 80%(volume fraction, φ) ethanol aqueous solution, a slow but full protein denaturation takes place, which would cause the unfolding of protein and the release of phthalates. Meanwhile, the fat-soluble impurities are extracted less in φ(ethanol) 80% aqueous solution than in either φ(ethanol) 100% or hydrophobic solvents in the liquid-liquid extraction procedure. Therefore the purification steps were greatly simplified. Overall recoveries were 81.77%―90.5% with limits of detection between 2.53 and 9.61 μg/L, and relative standard deviation values at 1.15%―4.85%. The proposed approach was satisfactorily applied to the determination of phthalates in real aquatic products, such as fish, shrimp and oyster.  相似文献   

2.
A simple and rapid sample preparation method of dispersive liquid-liquid microextraction(DLLME) was applied in the simultaneous determination of six parabens in the aqueous cosmetics. The analysis was performed on gas chromatography coupled with a flame ionization detection(GC-FID). The mixed solution containing 30 μL of chloroform(extraction solvent) and 300 μL of tetrahydrofuran(dispersive solvent) was rapidly injected into the sample solution for the purpose of microextraction. After that, the solution mentioned above was centrifuged at 4000 r/min for 10 min, and then the organic sediment phase was detected by GC-FID. The effects of experimental parameters, such as the extraction solvent and the volume of it, and the dispersive solvent and the volume of it, on the yield of the extraction were studied in detail. Under the optimum conditions, the enrichment factors of the target analytes range from 87 to 214. Linearity ranges are 0.05-10.0μg/mL for methylparaben and 0.025--5.0 μg/mL for the other five parabens. The relative standard deviations(RSDs) are lower than 8.2%(n=6). The proposed method was applied to the analysis of six parabens in eleven aqueous cosmetics. The recoveries of the target analytes in the spiked real samples are in the range of 81.0%-103%.  相似文献   

3.
A simple and efficient method for the selective separation and preconcentration of Ag+ using homogeneous liquid-liquid extraction was developed. Tetraspirocyclohexylcalix[4]pyrrole (TSCC4P) was synthesized and investigated as a suitable selective complexing ligand for Ag+. Zonyl FSA (FSA) was applied as a phase-separator agent under mild pH conditions. Under the optimal conditions ([TSCC4P] = 3.4 x 10(-4) M, [THF] = 25.0% v/v, [FSA] = 1.25% w/v, and pH = 4.5), 5 microg of Ag+ in 6.0 ml aqueous phase could be extracted quantitatively into 20 microl of the sedimented phase. The maximum concentration factor was 300-fold. The limit of detection of the proposed method was 0.005 ng/ml. The reproducibility of the proposed method was at most 3.5%. The influence of the pH, type and volume of the water-miscible organic solvent, concentration of FSA, concentration of the complexing ligand and the effect of different diverse ions on the extraction and determination of Ag+ were investigated. The proposed method was applied to the extraction and determination of Ag+ in different water samples.  相似文献   

4.
The degradation of hydrogenated nitrile-butadiene rubber(HNBR) soaped in aqueous solutions of H2S and HCl was investigated. The samples unexposed and exposed to different solutions were characterized by 13C nuclear magnetic resonance(13C NMR), X-ray photoelectron and infrared spectroscopies. In contrast to those of unexposed samples and samples soaped in HCl solution, the mechanical properties of samples exposed to H2S solution significantly deteriorated, in which the new groups of C(=O)―NH2, C―S―C and C=S emerged. The mechanism of C=S and C―S―C formation was speculated, except for that of the formation of group C(=O)―NH2, which was widely discussed in acidic condition such as HCl solution. The formation of C―S―C was due to radical reaction initiated by mercapto radical and that of C=S was due to nucleophilic reaction initiated by mercapto cations. This finding is helpful to understanding the seal failure of HNBR in working environment containing H2S.  相似文献   

5.
用分子荧光法、气相色谱法探讨了有机磷药物在以蛋白质为主要基质的水产品中的存在状态, 并研究了蛋白质对有机磷药物提取的影响. 结果表明, 有机磷药物与蛋白质有较强结合作用. 体积分数为70%~90%乙腈水溶液可引起蛋白质变性伸展, 利于释放结合的药物, 从而提高蛋白质基质中的有机磷提取回收率. 以体积比乙腈∶乙酸∶水=90∶1∶9的溶液提取鱼肉样品中的有机磷药物, 以PSA, GDX-103为混合颗粒吸附剂, 以无水硫酸镁、无水醋酸钠为混合无机盐除水剂, 经离心分离去除基质后萃取液直接进样测定了鱼肉中5种有机磷药物(敌敌畏、甲胺磷、乐果、甲基对硫磷和乙基对硫磷), 测定回收率为72.97%~107.21%, 检出限为0.002~0.045 mg•kg-1. 方法操作步骤简单、快速、高效.  相似文献   

6.
A method for the analysis of trace polycyclic aromatic hydrocarbons(PAHs) in aqueous samples has been established by polydimethylsiloxane(PDMS) rod aided stir bar sorptive extraction(SBSE). The homemade PDMS rod has a size of 30 mm?3 mm o.d. with a volume of ca. 200 ?L, stable in thermal desorption process. The enriched PAHs by the PDMS rod were released in a homemade thermal desorption system coupled with gas chromatography. Experimental parameters for extraction of six PAHs were optimized including extraction time, pH, ionic strength and temperature of solution. The procedure has good recoveries of 80.0%―100.3% and very low limits of detection of 4.0―33 ng/L. PAHs in rain and river water were analyzed by this method.  相似文献   

7.
Zhu B  Chen H  Li S 《色谱》2012,30(2):201-206
以密度小于水的轻质溶剂为萃取剂,建立了无需离心步骤的溶剂去乳化分散液-液微萃取-气相色谱(SD-DLLME-GC)测定水样中多环芳烃的新方法。传统分散液-液微萃取技术一般采用密度大于水的有机溶剂为萃取剂,并需要通过离心步骤促进分相。而本方法以密度比水小的轻质溶剂甲苯为萃取剂,将其与丙酮(分散剂)混合并快速注入水样,获得雾化体系;然后注入乙腈作为去乳化剂,破坏该雾化体系,无需离心,溶液立即澄清、分相;取上层有机相(甲苯)进行GC分析。考察了萃取剂、分散剂、去乳化剂的种类及其体积等因素对萃取率的影响。以40 μL甲苯为萃取剂,500 μL丙酮为分散剂,800 μL乙腈为去乳化剂,方法在20~500 μg/L范围内呈现出良好的线性(r2=0.9942~0.9999),多环芳烃的检出限(S/N=3)为0.52~5.11 μg/L。用所建立的方法平行测定5份质量浓度为40 μg/L的多环芳烃标准水样,其含量的相对标准偏差为2.2%~13.6%。本法已成功用于实际水样中多环芳烃的分析,并测得其加标回收率为80.2%~115.1%。  相似文献   

8.
以乙腈-无机盐-水双水相体系,建立了一种环保、高效的用于气相色谱法检测鱼肉样品中拟除虫菊酯的样品前处理方法.实验利用荧光猝灭法与气相色谱法研究了拟除虫菊酯药物在以蛋白质为主要基质的水产品中的存在状态,考察了双水相的形成条件,并探讨了蛋白质对双水相萃取率的影响.结果表明,拟除虫菊酯药物通过疏水作用力与蛋白质牢固结合.以体积分数为80%的乙腈水溶液作为萃取液可以引起水产品中的蛋白质基质缓慢而彻底地变性,从而充分释放与蛋白质结合的药物,实现拟除虫菊酯的均相高效萃取.80%的乙腈水溶液具有较强的化学极性,因而在双水相系统上相中与药物残留共同萃入的脂溶性杂质较少,萃取液净化步骤大大简化.在双水相上相中加入无水MgSO4,PSA去除水分与杂质后,直接进样进行气相色谱检测.该方法用于鱼肉样品中六种拟除虫菊酯的萃取检测,回收率为81.1%~96.4%,检出限为8~14ng·mL-1.  相似文献   

9.
A fast and reliable method was developed for the selective separation and preconcentration of Cu2+ ions using homogeneous liquid-liquid extraction using a novel benzo-substituted macrocyclic diamide, 5,6,7,8,9,10-hexahydro-2H-1,13,4,7,10-benzodioatriazacyclo-pentadecine-3,11(4 H,12 H)-dione, as a selective complexing agent. An aqueous solution of Zonyl FSA (FSA) was used as a phase-separation agent at pH 4.5. Electrothermal atomic absorption spectrometry was used for Cu2+ determination after preconcentration. The influences of pH, type and volume of the water-miscible organic solvent, concentration of FSA, concentration of the ligand and the effect of diverse ions were investigated. Factorial design and response surface methods were used for the optimization purposes. Under the optimum experimental conditions, 50 ng of Cu2+ in 5 mL aqueous sample could be extracted quantitatively into 76 µL of the sediment phase. The maximum preconcentration factor was 65. The calibration curve was linear in the concentration range 0.2 to 4.0 µg L?1. The detection limit and relative standard deviation were 4 ng L?1 and 4.6%, respectively. The method was successfully applied to the extraction and determination of Cu2+ in natural water samples.  相似文献   

10.
A simple and efficient method for the selective separation and preconcentration of uranium(VI) using homogeneous liquid-liquid extraction was developed. Tri-n-octylphosphine oxide (TOPO) and tri-n-butylphosphate (TBP) were investigated as complexing ligands, and perfluorooctanoate ion (PFOA-) was applied as a phase separator agent under strongly acidic conditions. Under the optimal conditions ([PFOA-] = 1.7 x 10(-3) M, [TOPO] = 5.4 x 10(-4) M, [HNO3] = 0.3 M, [acetone] = 3.2% v/v) 10 microg of uranium in 40 ml aqueous phase could be extracted quantitatively into 8 microl of the sedimented phase. The maximum concentration factor was 5000-fold. However, an effort for the quantitative extraction using TBP was inefficient and the percent recovery was at most 56.7. The influence of the type and concentration of acid solution, optimum amount of the ligand, type and volume of the organic solvent, concentration of PFOA, volume of the aqueous sample and effect of different diverse ions on the extraction and determination of uranium(VI) were investigated. The proposed method was applied to the extraction and determination of uranium(VI) in natural water samples.  相似文献   

11.
The authors performed ionic liquid-based microwave-assisted liquid-liquid microextraction(IL-based MALLME) coupled with high performance liquid chromatographic separation for the determination of 6 sulfonamides (SAs) from animal oils. The target analytes were extracted from animal oil samples with sodium hydroxide solution containing 1-butyl-3-methylimidazolium tetrafluoroborateand as the extraction solvent under microwave irradiation. The experimental parameters of the IL-based MALLME, including types of ILs, volume of IL, amount of ion-pairing agent(NH4PF6), pH value of sample solution, and extraction temperature and time were evaluated. The limits of detection and quantification obtained were in a range of 0.4―0.5 μg/kg and a range of 1.2―1.8 μg/kg, respectively. The accuracy of the method was evaluated by analyzing five spiked animal oil samples at two fortified levels(5 and 50 μg/kg), and the recoveries of SAs varied from 81.4% to 114.5% with relative standard deviations ranging from 0.8% to 9.0%.  相似文献   

12.
A novel temperature-controlled headspace liquid-phase microextraction (TC-HS-LPME) device was established in which volatile solvents could be used as extractant. In this device, a PTFE vial cap with a cylindrical cavity was used as the holder of the extraction solvent. Up to 40 μl of extraction solvent could be suspended in the cavity over the headspace of aqueous sample in the vial. A cooling system based on thermoelectric cooler (TEC) was used to lower the temperature of extractant in PTFE vial cap to reduce the loss of volatile solvent during extraction process and increase the extraction efficiency. The selection of solvents for HS-LPME was then extended to volatile solvents, such as dichloromethane, ethyl acetate and acetone. The use of volatile extraction solvents instead of semi-volatile solvent reduced the interference of the large solvent peak to the analytes peaks, and enhanced the compatibility of HS-LPME with gas chromatograph (GC). Moreover, the use of larger volume of extractant solvent increases the extraction capacity and the injection volume of GC after extraction, thus improving detection limits. Several critical parameters of this technique were investigated by using chlorobenzenes (CBs) as the model analytes. High enrichment factors (498–915), low limits of detection (0.004–0.008 μg/L) and precision (3.93–5.27%) were obtained by using TC-HS-LPME/GC-FID. Relative recoveries for real samples were more than 83%.  相似文献   

13.
In the present work, a combination of microwave-assisted extraction with magnetic ionic liquid–based dispersive liquid–liquid microextraction was developed for the extraction of chloramine–T from fish samples. In this method, the sample was mixed with a hydrochloric acid solution and exposed to microwave irradiations. By doing so, chloramine–T was converted to p–toluenesulfonamide and extracted from the sample into an aqueous phase. Then, a mixture of acetonitrile (as a dispersive solvent) and magnetic ionic liquid (as an extraction solvent) was rapidly injected into the obtained solution. In the following, the magnetic solvent droplets including the extracted analytes were isolated from the aqueous solution in the presence of an external magnetic field and after diluting with acetonitrile injected into high-performance liquid chromatography equipped with a diode array detector. Under the optimum extraction conditions, high extraction recovery (78%), low limits of detection (7.2 ng/g) and quantification (23.9 ng/g), good repeatability (relative standard deviations ≤5.8 and 6.8% for intra– and inter-day precisions, respectively), and wide linear range (23.9–1000 ng/g) were obtained. Finally, various fish samples marketed in Tabriz city (East Azarbaijan, Iran) were analyzed with the suggested method.  相似文献   

14.
Guo L  Lee HK 《Journal of chromatography. A》2011,1218(31):5040-5046
For the first time, the low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction was developed for the fast, simple, and efficient determination of 16 priority polycyclic aromatic hydrocarbons (PAHs) in environmental samples followed by gas chromatography-mass spectrometric (GC-MS) analysis. In the extraction procedure, a mixture of extraction solvent (n-hexane) and dispersive solvent (acetone) was injected into the aqueous sample solution to form an emulsion. A demulsification solvent was then injected into the aqueous solution to break up the emulsion, which turned clear and was separated into two layers. The upper layer (n-hexane) was collected and analyzed by GC-MS. No centrifugation was required in this procedure. Significantly, the extraction needed only 2-3 min, faster than conventional DLLME or similar techniques. Another feature of the procedure was the use of a flexible and disposable polyethylene pipette as the extraction device, which permitted a solvent with a density lighter than water to be used as extraction solvent. This novel method expands the applicability of DLLME to a wider range of solvents. Furthermore, the method was simple and easy to use, and some additional steps usually required in conventional DLLME or similar techniques, such as the aforementioned centrifugation, ultrasonication or agitation of the sample solution, or refrigeration of the extraction solvent were not necessary. Important parameters affecting the extraction efficiency were investigated in detail. Under the optimized conditions, the proposed method provided a good linearity in the range of 0.05-50 μg/L, low limits of detection (3.7-39.1 ng/L), and good repeatability of the extractions (RSDs below 11%, n=5). The proposed method was successfully applied to the extraction of PAHs in rainwater samples, and was demonstrated to be fast, efficient, and convenient.  相似文献   

15.
Polychlorinated biphenyls (PCBs) in sludge are usually extracted by a technique such as Soxhlet with subsequent fractionation prior to long GC runs using GC-ECD or GC-HRMS. In this study, the extraction of selected chlorinated biphenyls (CBs) from a spiked sludge sample by three rapid techniques, i.e. ultrasonic (USE), pressurised-liquid (PLE), and microwave-assisted (MAE) extraction using a domestic microwave, was studied, with subsequent direct GC-ECD, GC-MS, or GC x GC-microECD analysis of the extracts. The main goal was to select an appropriate, and miniaturised, extraction method after only a brief optimisation and demonstrate the power of GC x GC analysis of dirty extracts. For PLE similar CB recoveries were found when extracting with either n-hexane or n-hexane/acetone (1/1). For USE and MAE, n-hexane/acetone (1/1) was the preferred extraction solvent. USE gave the best recoveries (80-95%; except 130% for CB 105). The only clean-up needed prior to GC-MS or GC x GC-gECD analysis was the removal of sulphur-containing compounds. GC-ECD was not suitable for these dirty extracts. The lowest LODs for the CBs (20 fg or 0.1 ng/g sludge) were found when combining USE and GC x GC-microECD, because of the powerful extraction, high separation power and excellent detectability provided by this technique.  相似文献   

16.
An optimized method for the determination of two major carbon‐based engineered nanoparticles (C60 and C70) in marketed fish samples is described. The method involves the use of microwave‐assisted extraction (MAE) coupled with liquid chromatography ‐ tandem mass spectrometry with atmospheric pressure photoionization (LC‐APPI‐MS/MS). Factors affecting the extraction efficiency of the analytes from fish samples were optimized by a central composite design method. The optimal extraction temperature and time for MAE were found to be 233 °C for 22 min, and the extraction solution was composed of toluene and acetone in a ratio of 4.64:1. The limits of quantitation (LOQs) were 0.1 and 0.05 ng/g for C60 and C70, respectively. The precision for these analytes at two spiked levels, as indicated by relative standard deviations (RSDs), were less than 10% for both intra‐ and inter‐day analysis. Accuracy, expressed as the mean extraction recovery, was between 85 and 98%. The method was further validated based on EU Commission Decision 2002/657/EC, including a decision limit (CCα) and detection capability (CCβ) for marketed fish samples.  相似文献   

17.
Solid-phase microextraction (SPME) coupled to ultrasonic extraction was evaluated for extracting trace amounts of two agrochemical fungicides, vinclozolin and dicloran, in soil samples. Extraction was performed following two experimental approaches prior to the submission of the aqueous extracts to SPME-GC analysis. In the first approach, extraction involved sample homogenization with a water solution containing 5% (v/v) acetone and centrifugation prior to fiber extraction. In the second approach, the extraction of the fungicides from the soil samples was conducted using acetone as organic solvent which was then diluted with water to give a 5% (v/v) content. The pesticides were isolated with fused silica fiber coating with 85 μm polyacrylate. Parameters that affect both the extraction of the fungicides by the soil samples and the trapping of the analytes by the fiber were investigated and their impact on the SPME-GC-MS was studied. The procedures with respect to repeatability and limits of detection were evaluated by soil spiked with both analytes. Repeatability was between 5.6 and 14.2% and the limits of detection were 2-13 ng g−1. The efficiency of acetone/SPME was generally better than that for water/SPME procedure showing good linearity (R2>0.99) with coefficient variations below 9%, recoveries higher than 91% and limits of detection between 2 and 3 ng g−1. Finally, the recoveries obtained with acetone/SPME procedure were compared with the conventional liquid-liquid extraction using real soil samples. The acetone/SPME method was shown to be an inexpensive, fast and simple preparation method for the determination of target analytes at low nanogram per gram levels in soils.  相似文献   

18.
A new liquid-liquid microextraction method based on the solidification of floating organic drops coupled with gas chromatography was developed for the determination of trace benzene, toluene and xylene(BTX) in water samples. In the microextraction procedure, a microdrop of n-decanol was delivered to the surface of the analytes’ solution, and stirred for a desired time. Following the absolute extraction, the sample vial was cooled in an ice bath for 10 min. The solidified n-decanol was then transferred into a plastic tube and melted naturally; and 1 μL of it was injected into gas chromatography for analysis. Factors relevant to the extraction efficiency were studied and optimized. The optimal experimental conditions were: 15 μL of n-decanol as extractive solvent, 30 mL of solution containing analytes, no salt, the stirring rate 400 r/min, the extraction temperature 30 °C, and the extraction time 30 min. Under those optimized conditions, the detection limit(LOD) of analytes was in a range of 0.05―0.10 ng/mL by the developed method. A good linearity(r>0.99) in a calibration range of 0.01―100 μg/mL was obtained. The recoveries of the real samples at different spiked levels of BTX were in the range from 92.2% to 103.4%.  相似文献   

19.
In this study, a simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME) combined gas chromatography-electron capture detection (GC-ECD), for the determination of chlorobenzenes (CBs) in water samples, has been described. This method involves the use of an appropriate mixture of extraction solvent (9.5 μl chlorobenzene) and disperser solvent (0.50 ml acetone) for the formation of cloudy solution in 5.00 ml aqueous sample containing analytes. After extraction, phase separation was performed by centrifugation and the enriched analytes in sedimented phase were determined by gas chromatography-electron capture detection (GC-ECD). Our simple conditions were conducted at room temperature with no stiring and no salt addition in order to minimize sample preparation steps. Parameters such as the kind and volume of extraction solvent, the kind and volume of disperser solvent, extraction time and salt effect, were studied and optimized. The method exhibited enrichment factors and recoveries ranging from 711 to 813 and 71.1 to 81.3%, respectively, within very short extraction time. The linearity of the method ranged from 0.05 to 100 μg l−1 for dichlorobenzene isomers (DCB), 0.002-20 μg l−1 for trichlorobenzene (TCB) and tetrachlorobenzene (TeCB) isomers and from 0.001 to 4 μg l−1 for pentachlorobenzene (PeCB) and hexachlorobenzene (HCB). The limit of detection was in the low μg l−1 level, ranging between 0.0005 and 0.05 μg l−1. The relative standard deviations (R.S.D.s) for the concentration of DCB isomers, 5.00 μg l−1, TCB and TeCB isomers, 0.500 μg l−1, PeCB and HCB 0.100 μg l−1 in water by using the internal standard were in the range of 0.52-2.8% (n = 5) and without the internal standard were in the range of 4.6-6.0% (n = 5). The relative recoveries of spiked CBs at different levels of chlorobenzene isomers in tap, well and river water samples were 109-121%, 105-113% and 87-120%, respectively. It is concluded that this method can be successfully applied for the determination of CBs in tap, river and well water samples.  相似文献   

20.
A new method of dispersive liquid-liquid microextraction (DLLME) combined with GC-electron capture detection (GC-ECD) was proposed for the extraction and determination of four polychlorinated biphenyls (PCBs) congeners in fish samples. Acetone was used as extraction solvent for the extraction of PCBs from fish samples. The target analytes in the acetone solvent were rapidly transferred to chlorobenzene, which was used as extraction solvent in DLLME procedures. Under the optimum conditions, linearity was obtained in the concentration range from 1.25 to 1250 μg/kg for PCB 52, and 0.25 to 250 μg/kg for PCB 101, 138 and 153. Coefficients of correlation (r2) ranged from 0.9993 to 0.9999. The repeatability was tested by spiking fish samples at 10 μg/kg PCBs, and RSD% (n = 8) varied between 2.2 and 8.4%. The LODs were between 0.12 and 0.35 μg/kg. The enrichment factors of PCBs were from 87 to 123. The relative recoveries of the four PCB congeners for the perch, pomfret and yellow-fin tuna at spiking levels of 10, 20 and 50 μg/kg were in the range of 81.20–100.6%, 85.00–102.7% and 87.80–108.4%, respectively. The results demonstrated that DLLME combined with GC-ECD was a simple, rapid, and efficient technique for the extraction and determination of PCBs in fish samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号