1.
A polypyrrole/palladium composite film was prepared on a glassy carbon electrode by the electrochemical deposition method. The palladium particles were uniformly dispersed on a polypyrrole film that was previously electrodeposited on a glassy carbon electrode. By controlling the polymerization process of pyrrole, a highly porous polypyrrole film was obtained; this kind of structure provided more surface areas for depositing palladium particles. The sizes of Pd particles deposited on the porous polypyrrole film are about 15-30 nm. The X-ray photoelectron spectroscopy results showed there was strong interaction between polypyrrole film and palladium particles. This modified electrode showed excellent current efficiency (49.5%) for electrochemical hydrogenation of 4-chlorophenol and the phenol was the sole product. The potential effect on the dechlorination process was also investigated.  相似文献   

2.
Jan-Wei Shie 《Talanta》2009,78(3):896-75
A conductive biocomposite film (MWCNTs-NF-Hb) containing multi-walled carbon nanotubes (MWCNTs) incorporated with entrapped haemoglobin (Hb) in nafion (NF) has been synthesized on glassy carbon electrode (GCE), gold (Au), indium tin oxide (ITO) and screen printed carbon electrode (SPCE) separately by potentiostatic methods. The presence of both MWCNTs and NF in the biocomposite film enhances the surface coverage concentration (Γ), and increases the electron transfer rate constant (Ks) to 132%. The biocomposite film exhibits a promising enhanced electrocatalytic activity towards the reduction of O2, H2O2 and CCl3COOH. The cyclic voltammetry has been used for the measurement of electrocatalysis results of analytes by means of biocomposite film-modified GCEs. The MWCNTs-NF-Hb-modified GCEs’ sensitivity values are higher than the values obtained for other film modified GCEs. The surface morphology of the biocomposite films which have been deposited on ITO has been studied using scanning electron microscopy and atomic force microscopy. The studies have revealed that there was an incorporation of NF and immobilization of Hb on MWCNTs. Finally, the flow injection analysis has been used for the amperometric studies of analytes at MWCNTs-Hb and MWCNTs-NF-Hb film modified SPCEs. The amperometric study results have shown higher slope values for MWCNTs-NF-Hb biocomposite film.  相似文献   

3.
利用多壁碳纳米管具有较低的还原电位,以多壁碳纳米管作为还原剂和负载基底,通过无电沉积法制备了负载纳米金粒子的碳纳米管催化剂。此种材料具有更多的活性位点,避免了纳米金粒子表面保护剂的存在造成其催化活性降低的缺陷,发现其对典型黄酮类化合物-芦丁和黄芩苷具有良好的电化学催化性能和较高的灵敏度,并将其应用于电化学分析检测黄酮类化合物。  相似文献   

4.
A glassy carbon electrode (GCE) was modified with the nickel(II)-bis(1,10-phenanthroline) complex and with multi-walled carbon nanotubes (MWCNTs). The nickel complex was electrodeposited on the MWCNTs by cyclic voltammetry. The modified GCE displays excellent electrocatalytic activity to the oxidation of ascorbic acid (AA). The effects of fraction of MWCNTs, film thickness and pH values were optimized. Response to AA is linear in the 10 to 630 μM concentration range, and the detection limit is 4 μM (at a signal-to-noise ratio of 3:1). The modified electrode was applied to determine AA in vitamin C tablets and in spiked fruit juice.
Graphical Abstract
A simple and sensitive ascorbic acid electrochemical sensor was fabricated by electrodepositing of nickel complex onto multi-walled carbon nanotubes/glassy carbon electrode. The sensor has high selectivity, rapid current response, is easy to construct and can be utilized for ascorbic acid determination.  相似文献   

5.
In this study, 4‐thiophenol modified glassy carbon electrode was prepared by the reduction of 4‐diazothiophenol tetrafluoroborate salt. Silver nanoparticles were attached to the thiophenol modified surface to prepare a thiophenol‐silver nanoparticle composite film. 4‐Aminothiopenol molecules were deposited by self‐assembling technique to form multi‐layered nanofilms of TP/SNP/PhNH2 on glassy carbon substrate. These surfaces were characterized by cyclic voltammetry, electrochemical impedance spectroscopy, X‐ray photoelectron spectroscopy, reflectance‐absorption infrared spectroscopy, and ellipsometry at each multilayer film growth process. Atomic force microscopic images of GC/TP/SNP/PhNH2 surfaces were also acquired. The characterization methods show that the amine group containing surface permits the subsequent modification by a variety of coupling reactions for the immobilization of more complex systems. An application of the electrode modification for the determination of uric acid with a significantly lower detection limit is described. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
Shie JW  Yogeswaran U  Chen SM 《Talanta》2008,74(5):1659-1669
A novel conductive biocomposite film (MWCNTs–DNA–cyt c) which contains multi-walled carbon nanotubes (MWCNTs) along with the incorporation of DNA and cytochrome c (cyt c) has been synthesized on glassy carbon electrode (GCE), gold (Au), indium tin oxide (ITO) and screen printed carbon electrode (SPCE) by potentiostatic methods. The presence of both MWCNTs and DNA in the biocomposite film enhances the surface coverage concentration (Γ), increases the electron transfer rate constant (Ks) up to 21% and decreases the degradation of cyt c during the cycling. The biocomposite film also exhibits a promising enhanced electrocatalytic activity towards the reduction of halogen oxyanions and oxidation of biochemical compounds such as ascorbic acid and l-cysteine. The cyclic voltammetry has been used for the measurement of electroanalytical properties of analytes by means of biocomposite film modified GCEs. The sensitivity of MWCNTs–DNA–cyt c modified GCE possess higher values than the values obtained for DNA–cyt c film modified GCE. Further, the reduction potentials of halogen oxyanions Epc, clearly shows that the activity of the biocomposite is dependent on the electronegativity of halogen oxyanions. Electrochemical quartz crystal microbalance studies revealed the enhancements in the functional properties of MWCNTs, DNA and cyt c. We have studied the surface morphology of the biocomposite films using scanning electron microscopy and atomic force microscopy, which revealed that DNA and cyt c have been incorporated on MWCNTs. Finally, the flow injection analysis has been used for the amperometric detection of analytes at MWCNTs–DNA–cyt c film modified SPCE.  相似文献   

7.
TiO(2) nanoparticles were homogeneously coated on multiwalled carbon nanotubes (MWCNTs) by hydrothermal deposition, and this nanocomposite might be a promising material for myoglobin (Mb) immobilization in view of its high biocompatibility and large surface. The glassy carbon (GC) electrode modified with Mb-TiO(2)/MWCNTs films exhibited a pair of well-defined, stable and nearly reversible cycle voltammetric peaks. The formal potential of Mb in TiO(2)/MWCNTs film was linearly varied in the range of pH 3-10 with a slope of 48.65 mV/pH, indicating that the electron transfer was accompanied by single proton transportation. The electron transfer between Mb and electrode surface, k(s) of 3.08 s(-1), was greatly facilitated in the TiO(2)/MWCNTs film. The electrocatalytic reductions of hydrogen peroxide were also studied, and the apparent Michaelis-Menten constant is calculated to be 83.10 microM, which shows a large catalytic activity of Mb in the TiO(2)/MWCNTs film to H(2)O(2). The modified GC electrode shows good analytical performance for amperometric determination of hydrogen peroxide. The resultant Mb-TiO(2)/MWCNTs modified glassy carbon electrode exhibited fast amperometric response to hydrogen peroxide reduction, long term life and excellent stability. Finally the activity of the sensor for nitric oxide reduction was also investigated.  相似文献   

8.
姜炜  黄蕾  张玉忠 《分析化学》2011,39(7):1038-1042
构建了基于金纳米粒子/聚阿魏酸/多壁碳纳米管(AuNPs/PFA/MWCNTs)修饰电极的DNA计时库仑法生物传感器.利用循环伏安技术在多壁碳管修饰的玻碳电极表面上聚合一层阿魏酸,在恒电位条件下,在阿魏酸表面沉积金纳米粒子,巯基DNA作为探针通过金硫键固定在金纳米粒子表面.电化学交流阻抗技术(EIS)与扫描电镜(SEM...  相似文献   

9.
Principles and practical application of combinatorial electrochemistry in search for new electroactive materials in electroanalysis have been explored. Nanoparticles of three different metals: silver, gold and palladium have been independently synthesized on the glassy carbon spherical powder surface by electroless deposition process and characterized using both spectroscopic and electrochemical techniques. These three materials were then combined together onto basal plane pyrolytic graphite electrode surface and the application of the combinatorial approach to find the electrode material for bromide detection as model target analyte was demonstrated. The component electroactive for bromide detection was next identified and it was found that silver nanoparticles were the active ones. A composite electrode based on silver nanoparticle modified glassy carbon powder and epoxy resin was then fabricated and it was found to allow accurate determination of bromide. The electroactivity for the bromide determination of the composite electrode was compared with that of a bulk silver electrode and it was shown that the composite electrode is very efficient with a comparable electroactivity with only a portion of precious metals being used for its construction.  相似文献   

10.
TiO2 nanoparticles were homogeneously coated on multi-walled carbon nanotubes by hydrothermal deposition, this nanocomposite may be a promising material for myoglobin immobilization in view of its high biocompatibility and large surface. The glassy carbon electrode modified with Mb-TiO2/MWCNTs films exhibited a pair of weU defined, stable and nearly reversible cycle voltammetric peaks. The electron transfer between Mb and electrode surface, Ks of 3.08 s^-1, was greatly facilitated in the TiO2/ MWCNTs film. The electrocatalytic reductions of hydrogen peroxide were studied, the apparent Michaelis-Menten constant is calculated to be 83.10 μmol/L, which shows a large catalytic activity of Mb in the TiO2/MWCNTs film to H2O2.  相似文献   

11.
通过电沉积的方式在多壁碳纳米管(MWCNTs)修饰玻碳电极表面上沉积铂(pt)纳米粒子,并运用循环伏安法(CV)、示差脉冲伏安法(DPV)探讨了芦丁在铂纳米/碳纳米管/玻碳电极上的电化学行为.实验结果表明,芦丁在该修饰电极上呈现一对良好氧化还原峰,其氧化峰电流与浓度在3.2×10(-8)~1.2×10(-5)mol/L...  相似文献   

12.
A cysteamine (CysAm) nanostructure was generated to act as an intermediate layer between gold electrode and carbon nanotubes. A bare gold electrode was placed in a solution of CysAm to create a self-assembled monolayer on its surface. The modified electrode was then incubated with a solution of multi-walled carbon nanotubes. Cyclic voltammetry and atomic force microscopy were used to characterize the modified electrode. The results indicated that the number of functionalized MWCNTs on the surface of the electrodes increased by enhancing incubation time.
Figure
The aim of this paper is to investigate the variations of incubation time of bare gold electrode inside cysteamine solution for immobilization of MWCNTs on cysteamine modified electrode. It is found that the number of functionalized MWCNTs on the surface of cysteamine modified electrode increased by enhancing incubation time bare gold electrode inside cysteamine solution.  相似文献   

13.
In this paper, a novel and convenient electrochemical sensor for detection of methimazole (MMI) by differential pulse voltammetry is presented. This sensor was fabricated by dripping well-dispersed MWCNTs onto glassy carbon electrode (GCE) surface, and then poly-l-Arg (P-L-Arg) film was deposited on the electrode. Finally, Cu nanoparticles (CuNPs) were electrochemically deposited on the resulting film by using cyclic voltammetry to prepare CuNPs-P-L-Arg/MWCNTs/GCE. The surface morphology of the electrodes has been studied by scanning electron microscopy. Studies reveal that the irreversible oxidation of MMI was highly facile on CuNPs-P-L-Arg/MWCNTs/GCE. The dynamic detection range of this sensor to MMI was 5.2–50 µM, with the detection limit of 2 µM. A new voltammetric method for determination of MMI was erected and shows good sensitivity and selectivity, very easy surface update and good stability. The analytical application of the modified electrode is demonstrated by determining MMI in biological fluids (serum).  相似文献   

14.
We have investigated the direct electron transfer (DET) promoted by carbon nanotubes (CNTs) on an electrode containing immobilized glucose oxidase (GOx) with the aim to develop a third-generation glucose biosensor and a mediator-free glucose biofuel cell anode. GOx was immobilized via chitosan (CS) on a glassy carbon electrode (GCE) modified with multi-walled carbon nanotubes (MWCNTs). Cyclic voltammetric revealed that the GOx on the surface of such an electrode is unable to simultaneously demonstrate DET with the electrode and to retain its catalytic activity towards glucose, although the MWCNTs alone can promote electron transfer between GOx and electrode. This is interpreted in terms of two types of GOx on the surface, the distribution and properties of which are quite different. The first type exhibits DET capability that results from the collaboration of MWCNTs and metal impurities, but is unable to catalyze the oxidation of glucose. The second type maintains its glucose-specific catalytic capability in the presence of a mediator, which can be enhanced by MWCNTs, but cannot undergo DET with the electrode. As a result, the MWCNTs are capable of promoting the electron transfer, but this is without value in some mediator-free applications such as in third-generation glucose biosensors and in mediator-free anodes for glucose biofuel cells.
Graphical Abstract
Two types of glucose oxidase (GOx) are immobilized on the surface of multi-walled carbon nanotubes (MWCNTs)-modified electrode. DET (direct electron transfer)-GOx exhibits DET ability deriving from the collaboration of MWCNTs and metal impurities, is unable to electrooxidize glucose. GCA (glucose-specific catalytic activity)-GOx cannot undergo DET with the electrode.  相似文献   

15.
The electrochemical behavior of several biologically active catecolamines in studied on a glassy carbon electrode with the surface preliminarily modified by a composite film containing preliminarily carboxylated multi-walled carbon nanotubes (MWNT). The coatings are characterized by the methods of cyclic voltammetry and scanning microscopy. It is shown that the use of hybrid composites prepared by immobilizing MWNT and gold nanoparticles into the film of poly(isonicotinic) acid provides the high diffusion permeability of the surface layers and the efficiency of the electron transfer as regards catecolamines. The possibility of using these electrodes for selective determination of these substances in drugs widely used in the modern practical medicine is demonstrated.  相似文献   

16.
A sensitive and selective electrochemical method was developed for simultaneous determination of uric acid (UA), xanthine (XA) and hypoxanthine (HX) based on a poly (pyrocatechol violet)/carboxyl functionalized multi-walled carbon nanotubes composite film modified electrode. The preparation and basic electrochemical performance of the novel composite film modified glassy carbon electrode were investigated in details. The electrochemical behaviors of UA, XA and HX at the modified electrode were studied by cyclic voltammetry. The results showed that this new electrochemical sensor exhibited excellent electrocatalytic activity towards the oxidation of the three analytes. The mechanism of catalysis was discussed. The anodic peaks of the three species were well defined with lowered oxidation potential and enhanced oxidation peak currents, so the modified electrode was used for simultaneous voltammetric measurement of UA, XA and HX by differential pulse voltammetry. Under the optimum conditions, the detection limits were 0.16 μmol L(-1) for UA, 0.05 μmol L(-1) for XA and 0.20 μmol L(-1) for HX, respectively (S/N of 3). The proposed method has been successfully applied to simultaneous determination of UA, XA and HX in human serum samples.  相似文献   

17.
利用电聚合法和脉冲沉积技术制备了纳米银/聚多巴胺修饰的玻碳电极. 通过循环伏安法和示差脉冲伏安法研究了该修饰电极上对硝基苯酚的电化学行为; 讨论了扫描速度和支持电解质等条件对对硝基苯酚在修饰电极上催化还原的影响. 结果表明, 对硝基苯酚的示差脉冲峰电流在4×10-5~3×10-4 mol/L范围内呈良好的线性关系.  相似文献   

18.
A composite film (MWCNTs-PNF) which contains multi-walled carbon nanotubes (MWCNTs) along with the incorporation of poly(new fuchsin) (PNF) has been synthesized on glassy carbon electrode (GCE), gold (Au) and indium tin oxide (ITO) by potentiostatic methods. The presence of MWCNTs in the composite film enhances surface coverage concentration (Γ) of PNF to ≈176.5%, and increases the electron transfer rate constant (ks) to ≈346%. The composite film also exhibits promising enhanced electrocatalytic activity towards the mixture of biochemical compounds such as adenine (AD), guanine (GU) and thymine (THY). The surface morphology of the composite film deposited on ITO has been studied using scanning electron microscopy and atomic force microscopy. These two techniques reveal that the PNF incorporated on MWCNTs. Electrochemical quartz crystal microbalance study reveals the enhancement in the functional properties of MWCNTs and PNF. The electrocatalytic responses of analytes at MWCNTs and MWCNTs-PNF films were measured using both cyclic voltammetry (CV) and differential pulse voltammetry (DPV). From electrocatalysis studies, well separated voltammetric peaks have been obtained at the composite film for AD, GU and THY, with the peak separation of 320.3 and 132.7 mV between GU-AD and AD-THY respectively. The sensitivity of the composite film towards AD, GU and THY in DPV technique is 218.18, 12.62 and 78.22 mA M−1 cm−2 respectively, which are higher than MWCNTs film. Further, electroanalytical studies of AD, GU and THY present in single-strand deoxyribonucleic acid (ssDNA) have been carried out using semi-derivative CV and DPV.  相似文献   

19.
We describe a modified glassy carbon electrode (GCE) for the sensitive determination of nitrite in waste water samples. The GCE was modified by electrodeposition of cobalt oxide nanoparticles on multi-walled carbon nanotubes (MWCNTs) deposited on a conventional GCE. Scanning electron microscopy and electrochemical techniques were used for the characterization of the composite material which is very uniform and forms a kind of nanoporous structure. Electrochemical experiments showed that the modified electrode exhibited excellent electrocatalytic properties for nitrite. Amperometry revealed a good linear relationship between peak current and nitrate concentration in the 0.5 to 250???M range with a detection limit of 0.3???M (S/N?=?3). The method has been applied to the amperometric detection of nitrite. The modified electrode displays good storage stability, reproducibility, and selectivity for a promising practical application.
Figure
The dense and entangled CoOx/MWCNTs nanocomposite showed a three-dimensional nanoporous structure. The three-dimensional nanoporous structure provided ample space to allow fast mass transport of ions through the electrolyte/electrode interface as well as a conductive network for enhancing electronic conductivity which was favorable to the catalytic application of CoOx.  相似文献   

20.
Xu  Wailan  He  Junlin  Gao  Liuliu  Zhang  Jing  Yu  Chao 《Mikrochimica acta》2015,182(13):2115-2122

We describe a nanostructured immunosensor for the cardiovascular biomarker netrin 1. A glassy carbon electrode was consecutively modified with multi-walled carbon nanotubes (MWCNTs), nafion (to retain the MWCNTs), thionine-coated gold nanoparticles (Thi@AuNPs), and monoclonal antibodies against netrin 1. The modified electrode was characterized by transmission electron microscopy, cyclic voltammetry, differential pulse voltammetry, UV-visible spectrophotometry and X-ray diffraction. The presence of Thi@AuNPs warrants direct and convenient immobilization of the antibody. This immunoelectrode enables netrin 1 to be determined, best at a voltage of −300 mV (vs. SCE), with a limit of detection of 30 fg mL−1 (at an S/N ratio of 3) after a 50 min incubation time. The detection range extends from 0.09 to 1800 pg∙mL−1. The method is simple, sensitive, specific and reproducible. We presume this stable and reproducible biosensor to be useful for the early detection of cardiovascular diseases.

A high sensitivity immunoassay was developed for the detection of netrin 1 based on multi-walled carbon nanotubes, thionine and gold nanoparticles. Its excellent performance is ascribed to the good conductivity of MWCNTs and the combination of materials.