首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Mixtures of silver(I) and citrate that are used to produce silver nanoparticles evoke intense chemiluminescence with tris(2,2'-bipyridyl)ruthenium(II) and cerium(IV), which can be exploited for the determination of citrate ions and other analytes over a wide concentration range.  相似文献   

2.
We report a simple and efficient technique for the covalent immobilisation of a tris(2,2'-bipyridyl)ruthenium(II) derivative suitable for both chemiluminescence and electrochemiluminescence detection.  相似文献   

3.
4.
Ding SN  Xu JJ  Chen HY 《Electrophoresis》2005,26(9):1737-1744
The major goal of this work was to develop a new solid-state electrochemiluminescence (ECL) detector suitable for capillary electrophoresis (CE). The detector was fabricated by coating a sol-gel derived zirconia (ZrO(2))-Nafion composite film on a graphite electrode, then the zirconia-Nafion modified electrode was immersed in tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3) (2+)) solution to immobilize this active chemiluminescence reagent. The voltammetric and ECL behaviors of the detector were investigated and optimized in tripropylamine solution. The ratio of 53% for zirconia in the zirconia-Nafion composite provided the highest luminescence intensity of immobilized Ru(bpy)(3) (2+). The ECL can maintain its stability very well in the phosphate solution in the period of 5-90 h when the solid-state ECL detector was immersed in the solution all the time. The optimum distance of capillary outlet to the solid-state ECL detector has been found to be ca. 50-80 microm for a 75 microm capillary. The effects of ionic strength and pH of ECL solution on peak height were investigated. The CE with solid-state ECL detector system was successfully used to detect tripropylamine, lidocaine, and proline. The detection limits (S/N = 3) were 5 x 10(-9) mol.L(-1) for tripropylamine, 1 x 10(-8) mol.L(-1) for lidocaine and 5 x 10(-6) mol.L(-1) for proline, and the linear ranges were from 1.0 x 10(-8) to 1.0 x 10(-5) mol.L(-1) for tripropylamine, 5.0 x 10(-7) mol.L(-1) to 1.0 x 10(-5) mol.L(-1) for lidocaine and 1.0 x 10(-5) to 1.0 x 10(-3) mol.L(-1) for proline, respectively.  相似文献   

5.
The cyclic voltammetry and electrogenerated chemiluminescent (ECL) reactions of a series of quinolone and fluoroquinolone antibiotics were investigated in a flow injection analysis (FIA) system. 7-Piperazinyl fluoroquinolone antibiotics were found to participate as a coreactant in an oxidative-reductive ECL mechanism with tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) as the luminescent reagent. The reaction mechanism was investigated in order to understand and optimize the processes leading to light emission. The optimal conditions included a solution pH ∼7 at a flow rate of 3.0 mL min−1 with no added organic modifier and application of 1.2 V vs. a Pt quasi-reference electrode (QRE). Fluoroquinolones containing a tertiary distal nitrogen on the piperazine ring, such as enrofloxacin and ofloxacin, reacted to produce more intense ECL than those with a secondary nitrogen, such as ciprofloxacin and norfloxacin. The method linear range, precision, detection limits, and sensitivity for the detection of enrofloxacin and ciprofloxacin were compared to that of tripropylamine. The method was applied to the determination of the ciprofloxacin content in a pharmaceutical preparation. The assay is discussed in terms of its analytical figures of merit, ease of use, speed, accuracy and application to pharmaceutical samples.  相似文献   

6.
7.
Electrochemiluminescence(ECL) is a powerful transduction technique used in biosensing and in vitro diagnosis, while the mechanism of ECL generation is complicated and affected by various factors. Herein the effect of ionic strength on ECL generation by the classical tris(2,2'-bipyridyl)ruthenium(II)[Ru(bpy)32+]/tri-n-propylamine(TPrA) system was investigated. It is clear that the ECL intensity decreases significantly with the increase of ionic strength, most likely arising from the reduced deprotonation rate of TPrA+·. We further combined microtube electrode(MTE) with ECL microscopy to unravel the evolution of ECL layer with the variation of ionic strength. At a low concentration of Ru(bpy)32+, the thickness of ECL layer(TEL) nearly kept unchanged with the ionic strength, indicating the surface-confined ECL generation is dominated by the oxidative-reduction route. While at a high concentration of Ru(bpy)32+, ECL generation is dominated by the catalytic route and TEL increases remarkably with the increase of ionic strength, because of the extended diffusion length of Ru(bpy)33+ at a reduced concentration of TPrA·.  相似文献   

8.
In this paper, a novel electrochemiluminescence (ECL) sensor was constructed to determine herring sperm (HS) double-stranded (ds) DNA. Tetramethoxysilane and dimethyldimethoxysilane were selected as co-precursors to form an organically modified silicate (ORMOSIL) film for the immobilization of multiwall carbon nanotubes (MWNTs) wrapped by poly(p-styrenesulfonate) (PSS), and then Tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) was successfully immobilized on a glassy carbon electrode via ion-association. PSS was employed to increase the conductivity of the ORMOSIL film and disperse the cut MWNTs, which were cut and shortened in a mixture of concentrated sulfuric and nitric acids, in the film. It was found that MWNTs could adsorb Ru(bpy)32+ and acted as conducting pathways to connect Ru(bpy)32+ sites to the electrode. MWNTs also played a key role as materials for the mechanical and thermal properties. The ECL performance of this modified electrode was evaluated in a flow injection analysis (FIA) system, and the detection limit (S/N = 3) for HS ds-DNA was 2.0 × 10−7 g mL−1 with a linear range from 1.34 × 10−6 to 6.67 × 10−4 g mL−1 (R2 = 0.9876). In addition, the ECL sensor presented excellent characteristics in terms of stability, reproducibility and application life.  相似文献   

9.
Costin JW  Barnett NW  Lewis SW 《Talanta》2004,64(4):894-898
Flow injection methodology is described for the determination of proline in red and white wines using tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection. Selective conditions were achieved for proline at pH 10, while other amino acids and wine components did not interfere. The precision of the method was less than 1.00% (R.S.D.) for five replicates of a standard (4 × 10−6 M) and the detection limit was 1 × 10−8 M. The level of proline in white and sparkling wines using the developed methodology was equivalent to those achieved using HPLC-FMOC amino acid analysis. SPE removal of phenolic material was required for red wines to minimize Ru(bipy)33+ consumption and its associated effect on accuracy.  相似文献   

10.
Meng H  Wu F  He Z  Zeng Y 《Talanta》1999,48(3):571-577
A chemiluminescence (CL) detection for the determination of sulfite using the reaction of Ru(bipy)(3)(2+) (bipy=2,2'-bipyridyl) -SO(3)(2-)-KMnO(4) is described. The concentration of sulfite is proportional to the CL intensity from 5.0x10(-8) to 1.25x10(-4) mol l(-1). The limit of detection is 2.5x10(-8) mol l(-1) and the relative standard deviation is 4.9% for the 2x10(-5) mol l(-1) sulfite solution in six repeated measurements. This method has been successfully applied to the determination of sulfite in sugar and sulfur dioxide in air by using triethanolamine (TEA) as the absorbent material.  相似文献   

11.
A chemiluminescence (CL) method using flow injection (FI) has been investigated for the rapid and sensitive determination of enalapril maleate. The method is based on the CL reaction of the drug with tris(2,2'-bipyridyl)ruthenium(II), Ru(bipy)3(2+) and acidic potassium permanganate. After selecting the best operating parameters, calibration graphs were obtained over concentration ranges of 0.005-0.2 microg/ml and 0.7-100 microg/ml with a detection limit (S/N=2) of 1.0 ng/ml. The average % found was 99.9 +/- 0.7 and 100.2 +/- 0.3 for the two concentration ranges respectively. %RSD (n=10) for 5.0 microg/ml was 0.44. The method was successfully applied to the determination of enalapril maleate in dosage forms and biological fluids without interferences.  相似文献   

12.
Two enantiomers of a new 4,5-pineno-2,2'-bipyridine ligand were synthesized and subsequently incorporated into hemicage ligands through a phenyl linker to yield ligands (+)-L1 and (-)-L1 or through a mesityl linker to yield ligands (+)-L2 and (-)-L2. Complexation of these ligands to Ru(II) afforded diastereomerically pure Delta and Lambda isomers, as verified through circular dichroism and circularly polarized luminescence spectroscopy. Ligands (+)-L2 and (-)-L2 were further coordinated to Zn(II) to form a complex with intriguing photophysical properties. Whereas Zn(bpy)32+ was shown to be a fluorescent emitter outside the visible spectrum, the caging process provided an unprecedented enhancement of intersystem crossing and subsequent switching to the phosphorescent emission of blue light. Additionally, the chiroptical properties of the Zn(II) complexes were also studied.  相似文献   

13.
Asensitive and selective method employing chemiluminescence(CL) coupled with flow injection(FI) is reported for nalbuphine hydrochloride(NAL) assay in pharmaceutical formulations. The enhancement effect of NAL on the CL reaction between tris(2,2'-bipyridyl)ruthenium(II) chloride-diperiodatocuprate(III) {Ru[(bpy)3]2+-Cu(III) complex} in acidic medium is used as analytical measurement. The optimal conditions of the CL reaction were sulfuric acid 1.0×10-3 mol/L, Ru[(bpy)3]2+ 7.5×10-5 mol/L, Cu(III)/Ag(III) complexes 4.0×10-4/5.0×10-4 mol/L, sample loop volume of 120 μL and flow rate of 2.5 mL/min. The sensitivities of the method in terms of detection(S/N=3) and quantification(S/N=10) limits are 5×10-4 and 0.001 ppm(1 ppm=1 mg/L), respectively. The linear response of the instrument in the form of CL intensity with respect to NAL concentration is over the range 0.001-15.0 ppm(R2=0.9999) with relative standard deviation from 0.8% to 3.2% and injection throughput of 120 injection/h. The applications of the method include the quantitative analysis of NAL in pharmaceutical injection samples. Variations and the average results of the proposed method are not signi-ficantly different from the results of a reported method by applying F- and paired student t-test. The most likely CL reaction mechanism is written in accordance with spectrophotometric and CL studies.  相似文献   

14.
An electrogenerated chemiluminescence (ECL) method for the determination of pethidine, atropine, homatropine and cocaine is described. The optimum conditions were found to be similar for all of these compounds although the ECL emission intensity for cocaine was an order of magnitude lower than for pethidine due to their different chemical structures. Linear calibrations were obtained for all the compounds at pH 10 in borate buffer (0.05 mol l-1) at 1.3 V. Limits of detection of 6.8 x 10(-8), 2.2 x 10(-7), 3.2 x 10(-7) and 6.5 x 10(-7) mol l-1, respectively, were achieved for pethidine, atropine, homatropine and cocaine in standard solutions. Solid-phase extraction was used to separate the drugs from their matrix and the method was applied to the determination of spiked urine samples. The limits of quantitation for pethidine, atropine, homatropine and cocaine in urine were 1.0 x 10(-6), 2.0 x 10(-6), 2.0 x 10(-6) and 4.0 x 10(-6) mol l-1, respectively, with recoveries of between 90 and 110%.  相似文献   

15.
Xu G  Pang HL  Xu B  Dong S  Wong KY 《The Analyst》2005,130(4):541-544
The dependence of the electrochemiluminescence of Ru(bpy)3(2+) (bpy = 2,2'-bipyridine) with tri-n-propylamine as co-reactant on the anionic surfactant SDS (sodium dodecyl sulfate) and the cationic surfactants CTAX (CTA = cetyltrimethylammonium cation, X = bromide, chloride and hydrogensulfate) was studied. Both SDS and CTAX, at low surfactant concentrations below the critical micelle concentrations, enhance the electrochemiluminescence at a platinum working electrode. A further enhancement of the light emission intensity by bromide ions was observed when CTAB (B = bromide) was used-an overall 30-fold increase in electrochemiluminescence efficiency was obtained at a CTAB concentration of 0.08 mM. Voltammetric data support adsorption of surfactant molecules on the electrode surface as the cause of the enhancement of electrochemiluminescence by ionic surfactants.  相似文献   

16.
The mono-isopropylamine salt of glyphosate was selectively determined directly in industrial and commercial formulations using flow injection analysis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection without the need for separation. Glyphosate and its mono-isopropylamine salt furnished detection limits of 7×10−9 and 3.5×10−10 M and relative standard deviations of 0.4% at 1×10−7 M and 0.8% at 5×10−8 M, respectively. The methodology is robust and reliable with samples subjected only to aqueous dilution prior to analysis.  相似文献   

17.
A flow-injection method is reported for the determination of thyroxine based on its enhancement effect on the tris(2,2'-bipyridyl)ruthenium(III) chemiluminescence reaction in the presence of NADH using immobilized alcohol dehydrogenase purified from baker yeast. The limit of detection (3 sigma blank) was 5.0 x 10(-8) M with a sample throughput of 80 h(-1). The calibration graph was linear over the range 0.5 - 10 x 10(-7) M (r2= 0.9988) with the relative standard deviation in the range 1.4 - 3.5% (n = 4). The effect of common excipients used in pharmaceutical preparations, some organic compounds and metal ions was studied. The method was applied to pharmaceutical thyroxine tablets, and the obtained results were not significantly different from the amount quoted.  相似文献   

18.
This paper describes, for the first time, a simple and effective synthetic route for covalently bonding the chemiluminescence reagent, (4-[4-(dichloromethylsilanyl)-butyl]-4'-methyl-2,2'-bipyridyl)bis(2,2'-bipyridyl)ruthenium(II) onto silica particles. The subsequent preparation of chemically regeneratable detection cells and their preliminary analytical evaluation with both sequential injection analysis and flow injection analysis are also reported. Unoptimised analytical figures of merit were established for standard solutions of codeine and sodium oxalate with detection limits calculated from three times the standard deviation of the blank signal, of 1 x 10(-8) M and 3 x 10(-7) M respectively. The chemically immobilised reagent exhibited some intriguing solvent and kinetic effects, which are also briefly discussed.  相似文献   

19.
Liu J  Cao W  Yang X  Wang E 《Talanta》2003,59(3):453-459
Tris(2,2′-bipyridyl)ruthenium(II) electrochemiluminescence detection in a capillary electrophoresis separation system was used for the determination of diphenhydramine. In this study, platinum disk electrode (300 μm in diameter) was used as a working electrode and the influence of applied potential and buffer conditions were investigated. Under optimal conditions: 1.2 V applied potential, pH 8.50, 15 kV separation voltage and 10 mmol l−1 running buffer, the calibration curve of diphenhydramine was linear over the range of 4×10−8 to 1×10−5 mol l−1. This technique gave satisfactory precision, and relative standard deviations of migration times and chemiluminescence peak intensities were less than 1 and 6%, respectively. The technique was applied to animal studies for determination of diphenhydramine extracted from rabbit plasma and urine samples, and the extraction efficiency were between 92 and 98.5%.  相似文献   

20.
A simple, rapid and sensitive method for the determination of psilocin and psilocybin is described. This is the first report on the determination of psilocin and psilocybin using flow injection analysis with acidic potassium permanganate and tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence. The limits of detection (signal-to-noise ratio = 3) are 9 × 10−10 M and 3 × 10−10 M for psilocin and psilocybin, respectively.A concise synthetic route for psilocin in three steps from readily available starting materials is also described. The structures were elucidated on the basis of spectroscopic data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号