首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
《Analytical letters》2012,45(3):569-578
Abstract

Applying capillary zone electrophoresis (CZE) to separate the components of Cephradine for Injection: cephradine, and L‐arginine, as well as cephalexin, which is the degradation product of cephradine was studied. The best results were achieved with background electrolyte consisting of 50 mM disodium hydrogen phosphate buffer at pH 6.5 and an applied voltage of 20 kV in a bare fused‐silica capillary. The samples were injected at 50 mbar for 4 s. The capillary temperature was 25°C and the UV detection was performed at a wavelength of 195 nm. Histidine was used as internal standard (IS) to ensure acceptable precision data. The linear ranges of cephradine, L‐arginine, and cephalexin were 93.8–6255.6 µg/mL, 47.9–3195.2 µg/mL, and 6.1–405.4 µg/mL, respectively. Quantitative parameters such as accuracy, precision, limit of detection (LOD), and limit of quantitation(LOQ) were all established in CZE mode.  相似文献   

2.
A mixture of five tetracycline (TC) derivatives: minocycline (MC), demeclocycline (DMCTC), doxycycline (DC), and sancycline (SC), as well as each TC derivative from its main degradation product were separated by capillary zone electrophoresis (CZE). The influence of the pH and the concentration and nature of the background electrolyte (BGE) on the separations was investigated. Ethylenediaminetetraacetic acid (EDTA; 1 mM) was used as additive in a 25 mM phosphate buffer (pH 2.3) because this BGE enabled the rapid separation of the TC derivatives and of each TC derivative from its respective degradation product in less than 6 min. After optimization of the separation conditions, the analytical characteristics of the method were investigated. The parameters involved were linearity, precision (repeatability and reproducibility), and limits of detection (LODs). LODs obtained for the five TC derivatives studied were about 3 microg/mL. Finally, the CZE method developed was applied to study the stability of TC derivatives and to analyze the TC derivative content in three different pharmaceutical preparations.  相似文献   

3.
To probe separation mechanism and determination with capillary zone electrophoresis (CZE) and liquid chromatography (LC), nine compounds with identical flavanone skeleton were studied. Optimum separation of LC was attained with gradient of acetonitrile and 5mM phosphate buffer (pH 6.9). For CE, electrolyte buffer was 4.5mM SDS in 32mM sodium tetraborate buffer (pH 9.2). The distinguishing feature in this work was successful separation of monohydroxyl stereoisomers by CZE. Polarity is generally increased with hydroxyl groups. In a separation mechanism study, polarity would be reduced by intramolecular hydrogen bond between hydroxyl of C5 and carbonyl group of C4. Comparison of the retention results among monohydroxyl flavanones shows polarity with hydroxyl at C6 the least, and that at C4' and C7 nearly equal. Also, elution order of flavones and flavanones would be adverse due to the hydroxyl at C3 in LC. From the numerical value pK(a) of flavanone, the C7-OH is the smallest, and two hydroxyl groups in an adjacent position is always less than the unique one caused by forming a stable 5-membered ring. Investigation of separation mechanism yield only the effect of constituent but also reasonable explanation for contradictory results between Wulf and our laboratory, this due to the hydroxyl at C3.  相似文献   

4.
Capillary zone electrophoresis (CZE) has been elaborated for separation, identification and determination of ciprofloxacin and its impurities. The separation, phosphate buffer pH 6.0 was supplemented with 0.075 M pentane-1-sulfonic acid sodium salt. The elaborated method was validated. The selectivity, linearity, limits of detection (LOD) and quantification (LOQ), precision, and accuracy of capillary zone electrophoresis were evaluated. The results obtained by CZE were also compared with those obtained by liquid chromatography. Regarding the validation results the CE method fulfils the current European Pharmacopoeia (Eur. Ph.) requirements. The evaluated CE method could be applicable to the analysis of different medicinal products containing ciprofloxacin.  相似文献   

5.
Lee D  Shamsi SA 《Electrophoresis》2000,21(12):2405-2411
Nine component mixtures of a furan library were simultaneously separated by capillary zone electrophoresis (CZE) using a phosphate buffer as a background electrolyte at low pH. The effects of buffer concentration, buffer pH, type and concentration of organic solvents on the electrophoretic mobility, resolution, and analysis time were systematically investigated. Resolution and efficiency of furan library components were further improved using cyclodextrin (CD)-modified CZE. Under optimum conditions, eight of the nine furans were baseline-resolved in less than 10 min at 30 kV using 50 mM phosphate buffer, 10% v/v acetonitrile (ACN), pH 2.0, with 5 mM gamma-CD.  相似文献   

6.
《Analytical letters》2012,45(10):1458-1470
Abstract

A capillary zone electrophoresis (CZE) method for the simultaneous determination of the β-blocker drugs atenolol and chlorthalidone in pharmaceutical formulations has been developed. The CZE separation was performed under the following conditions: capillary temperature, 25°C; applied voltage, 25 kV; 20 mM H3PO4–NaOH running buffer (pH 9.0); and detection wavelength, 198 nm. Phenobarbital was used as internal standard. The method was validated and showed not only good precision and accuracy but also good robustness. The method has been successfully applied to the simultaneous determination of both atenolol and chlorthalidone in pharmaceutical tablets.  相似文献   

7.
许庆平  何友昭 《色谱》2006,24(4):392-395
在磷酸缓冲体系中采用毛细管区带电泳法测定卷烟中的生物碱时,检测灵敏度低,分离度差。考察了卷烟中生物碱的 提取条件,分离缓冲溶液的类型、pH值和浓度,卷烟中生物碱测定方法的线性范围、检出限、重现性和回收率。结果发 现,当采用410 mmol/L的酒石酸溶液(pH 2.8)为缓冲体系时,卷烟中生物碱的检测灵敏度和分离度均有明显改善,烟碱 的线性范围为0.06~0.80 mg/L(其他生物碱为0.006~0.10 mg/L),检出限为0.002~0.01 mg/L,相对标准偏差为2.2%~10%,回收率为87.6%~102%。  相似文献   

8.
An electrophoretically mediated microanalysis method with a partial filling technique was developed for flavin-containing monooxygenase, form 3 (FMO3). The in-line enzymatic reaction was performed in 100 mM phosphate reaction buffer (pH 7.4) whereas 150 mM phosphate buffer (pH 3.3) was used as a background electrolyte. A long plug of cofactor NADPH dissolved in reaction buffer was hydrodynamically injected into a fused-silica capillary, followed by enzyme and substrate solution. The reaction was initiated at 37 degrees C in the thermostated part of the cartridge by the application of 9 kV for 0.9 min. The voltage was turned off to increase the product amount (zero-potential amplification) and again turned on at a constant voltage of 10 kV to elute all the components. Direct detection was performed at 191 nm. The developed electrophoretically mediated microanalysis method was applied for the kinetics study of FMO3 using clozapine as a substrate probe. A Michaelis-Menten constant (K(m)) of 410.3 microM was estimated from the corrected peak area of the product, clozapine N-oxide. The calculated value of the maximum reaction velocity (V(max)) was found to be 1.86 nmol/nmol enzyme/min. The acquired FMO3 kinetic parameters are in accordance with the published literature data.  相似文献   

9.
The combination of capillary isotachophoresis (ITP) and capillary zone electrophoresis (CZE) in the column-coupling configuration has been optimized in a mode in which the background electrolyte employed in the CZE step was different from the leading and terminating electrolytes of the ITP step. The optimum composition of the electrolyte system was 0.01 M HCl, 0.02 M IMI, 0.2% HEC, pH 7.2 (leading electrolyte), 0.01 M HEPES, pH 8.2 (terminating electrolyte), and 25 mM MES, 50 mM TRIS, 30 mM boric acid, 0.2% HEC, pH 8.3 (background electrolyte). All solutions contained 20% methanol. The timing of the transfer of isotachophoretically stacked analyte zones into the CZE column was also optimized. An ITP–CZE method with UV detection at 270 nm was developed for separation of nine phenolic acids (protocatechuic, syringic, vanillic, cinnamic, ferulic, caffeic, ρ-coumaric, chlorogenic, and gentisic acids) in a model mixture and used for assay of some of these acids in a methanolic extract of herba epilobi. Application of ITP–CZE resulted in 100-fold better sensitivity than conventional CZE; limits of detection ranged between 10 and 60 ng mL−1. When MES–TRIS–borate-based buffer, pH 8.3, was used in the CZE separation step the linearity of the ITP–CZE response was satisfactory (correlation coefficients were from 0.9937 to 0.9777). Repeatability was also satisfactory (RSD values ranged between 0.77% and 1.28% for migration times and between 1.65% and 13.69% for peak area). Revised: 23 March and 27 April 2006  相似文献   

10.
A simple, fast, inexpensive and reliable capillary zone electrophoresis (CZE) method for the determination of econazole nitrate in cream formulations has been developed and validated. Optimum conditions comprised a pH 2.5 phosphate buffer at 20 mmol L(-1) concentration, +30 kV applied voltage in a 31.5 cm x 50 microm I.D. capillary. Direct UV detection at 200 nm led to an adequate sensitivity without interference from sample excipients. A single extraction step of the cream sample in hydrochloric acid was performed prior to injection. Imidazole (100 microg mL(-1)) was used as internal standard. Econazole nitrate migrates in approximately 1.2 min. The analytical curve presented a coefficient of correlation of 0.9995. Detection and quantitation limits were 1.85 and 5.62 microg mL(-1), respectively. Excellent accuracy and precision were obtained. Recoveries varied from 98.1 to 102.5% and intra- and inter-day precisions, calculated as relative standard deviation (RSD), were better than 2.0%. The proposed CZE method presented advantageous performance characteristics and it can be considered suitable for the quality control of econazole nitrate cream formulations.  相似文献   

11.
A sensitive high-performance capillary zone electrophoresis (CZE) with head-column field-amplified sample stacking (FASS) in binary system has been developed for the simultaneous determination of zotepine and its active metabolite, norzotepine, in human plasma. The separation of zotepine and norzotepine was performed using a background electrolyte consisting of 50% ethylene glycol-borate buffer (20mM, pH 8.0) solution with 20% methanol as the running buffer and on-column detection at 200 nm. Under the optimal FASS-CZE condition, good separation with high efficiency and short analysis time is achieved. Several parameters affecting the separation and sensitivity of the drug were studied, including sample matrix, pH and concentrations of the borate buffer, ethylene glycol and methanol. Using clozapine as an internal standard, the linear ranges of the method for the determination of zotepine and norzotepine in human plasma were over 3-100 ng/mL; the detection limits of zotepine and norzotepine in plasma were 2 and 1 ng/mL, respectively. A sample pretreatment by means of solid-phase extraction (SPE) with subsequent quantitation by FASS-CZE was used. The application of the proposed method for determination of zotepine and norzotepine in plasma collected after oral administration of 125 mg zotepine in one schizophrenic patient was demonstrated.  相似文献   

12.
Five flavonoids (hyperoside, isoquercitrin, quercitrin, quercetin and rutin) were separated and determined in extracts of Hypericum perforatum leaves or flowers by capillary zone electrophoresis (CZE) with isotachophoretic (ITP) sample pre-treatment using on-line column coupling configuration. The background electrolyte (BGE) used in the CZE step was different from the leading and terminating ITP electrolytes but all the electrolytes contained 20% (v/v) of methanol. The optimal leading electrolyte was 10 mM HCl of pH* approximately 7.2 (adjusted with Tris) and the terminating electrolyte was 50 mM H3BO3 of pH* approximately 8.2 (adjusted with barium hydroxide). This operational system allowed to concentrate and pre-separate selectively the flavonoid fraction from other plant constituents before the introduction of the flavonoids into the CZE capillary. The BGE for the CZE step was 50 mM Tris buffer of pH* approximately 8.75 containing 25 mM N-[tris(hydroxymethyl)methyl]-3-aminopropanesulfonic acid as co-ion and 55 mM H3BO3 as complex-forming agent. The ITP-CZE method with spectrophotometric detection at 254 nm was suitable for the quantitation of the flavonoids in real natural samples; kaempferol was used as internal standard. The limit of detection for quercetin-3-O-glycosides was 100 ng ml(-1) and calibration curves were rectilinear in the range 1-10 microg ml (-1) for most of the analytes. The RSD values ranged between 0.9 and 2.7% (n=3) when determining approximately 0.07-1.2% of the individual flavonoids in dried medicinal plants.  相似文献   

13.
Doripenem, the latest carbapenem antibiotic licensed in the United States (15 October 2007) and the European Union (25 July 2008), has been implemented into therapeutic use along with imipenem, meropenem and ertapenem. The described method of zone electrophoresis in a low pH buffer for the separation of doripenem from its impurities has been successfully performed using field‐amplified sample stacking (FASS), followed by UV absorption detection at 214 nm. The best results were obtained with phosphate buffer (100 mM) pH 2.9 containing 10% (v/v) of methanol, as the background electrolyte. Uncoated fused‐silica capillary (60/52 cm; 75 μm id) with normal polarity, and voltage values of 25 kV, was used throughout the investigation. The optimised method of doripenem determination was validated in terms of linearity, accuracy and precision, and provides a detection limit of 3.0 μg/mL of doripenem. The repeatability, expressed by relative standard deviation (RSD) of the migration time, for doripenem and its degradation products varied from 1.37 to 2.51%, whereas the corrected peak areas were about 0.91–9.87%. Satisfactory separation was achieved within 20 min of electrophoresis; moreover, all carbapenems (imipenem, meropenem, ertapenem and doripenem) were well separated from each other during this time. The evaluated CZE method was applied in the analysis of a medicinal product containing doripenem Doribax® powder for solution for infusion.  相似文献   

14.
Monoclonal antibodies (mAbs) have become an important class of biopharmaceuticals used for the treatment of various diseases. Their quantification during the manufacturing process is important. In this work, a capillary zone electrophoresis (CZE) method was developed for the monitoring of the mAb concentration during cell-culture processes. CZE method development rules are outlined, particularly discussing various capillary coatings, such as a neutral covalent polyvinyl alcohol coating, a dynamic successive multiple ionic-polymer coating, and dynamic coatings using background electrolyte additives such as triethanolamine (T-EthA) and triethylamine. The dynamic T-EthA coating resulted in most stable electro-osmotic flows and most efficient peak shapes. The method is validated over the range 0.1–10 mg/ml, with a linear range of 0.08–1.3 mg/ml and an extended range of 1–10 mg/ml by diluting samples in the latter concentration range 10-fold in water. The intraday precision and accuracy were 2%–12% and 88%–107%, respectively, and inter-day precision and accuracy were 4%–9% and 93%–104%, respectively. The precision and accuracy of the lowest concentration level (0.08 mg/ml) were slightly worse and still well in scope for monitoring purposes. The presented method proved applicable for analysing in-process cell-culture samples from different cell-culture processes and is possibly well suited as platform method.  相似文献   

15.
毛细管区带电泳法测定葡萄籽中儿茶素类化合物   总被引:9,自引:0,他引:9  
李奕  高军涛  张志玲  刘虎威  赵保路 《色谱》2000,18(6):491-494
 采用毛细管区带电泳法测定了 10种中国产葡萄籽中的 4个主要儿茶素类化合物 :(+)儿茶素、(- )表儿茶素、(± )表没食子儿茶素、(± )表儿茶素没食子酸酯的含量。在 0 0 2mol/L硼砂和 0 0 0 5mol/L磷酸盐的混合缓冲体系 (pH 10 0 )的背景缓冲液中 ,4个化合物在 10min内取得了令人满意的分离。迁移时间的重现性(RSD)小于 2 % ,峰面积的重现性 (RSD)小于 5 %。在质量浓度为 0 0 0 5g/L~ 0 5 g/L时 ,线性相关系数大于0 995。检测限为 3mg/L~ 10mg/L。该方法简单、快速、准确 ,可作为葡萄籽分析和药用开发过程中分析儿茶素类化合物的有效方法推广使用。  相似文献   

16.
Tuberculosis (TB), an infectious disease caused by Mycobacterium tuberculosis, infects approximately one third of the current world population. Isoniazid is one of the most frequently used first-line anti-TB drugs. In this study, we developed a sensitive cation-selective exhaustive injection–sweeping–micellar electrokinetic chromatography method (CSEI-Sweep-MEKC) for analyzing isoniazid in human plasma. Parameters including acetonitrile (ACN) percentage in the separation buffer; the injection time, and concentration of the high-conductivity buffer; sodium dodecyl sulfate (SDS) concentration; phosphate concentration in the sample matrix; and the sample injection time were all optimized to obtain the best analytical performance. The optimal background electrolyte comprised 50 mM phosphate buffer, 100 mM SDS, and 15% ACN. Non-micelle background electrolyte, containing 75 mM phosphate buffer and 15% ACN, was first injected into the capillary, followed by a short plug of 200 mM phosphate (high-conductivity buffer). Run-to-run repeatability (n = 3) and intermediate precision (n = 3) of peak area ratios were found to be lower than 8.7% and 11.4% RSD, respectively. The accuracy of the method was within 98.1–106.9%. The limit of detection of isoniazod in human plasma was 9 ng mL−1. Compared with conventional MEKC, the enhancement factor of the CSEI-Sweep-MEKC method was 85 in plasma samples. The developed method was successfully used to determine isoniazid concentration in patient plasma. The results demonstrated that CSEI-Sweep-MEKC has the potential to analyze isoniazid in human plasma for therapeutic drug monitoring and clinical research.  相似文献   

17.
A capillary zone electrophoretic method has been developed and optimized for separation of four atypical antipsychotics (AAPs): clothiapine (cT), clozapine (cZ), olanzapine (O), and quetiapine (Q). A three-level full-factorial design was applied to study the effect of the pH and molarity of the running buffer on separation. Combination of the studied parameters permitted the separation of the four AAPs, which was best carried out using 80 mM sodium phosphate buffer (pH 3.5). The same system can also be applied for the quantitative determination of these compounds. The method was then validated regarding linearity, precision, and accuracy. Especially, the possibility of simultaneous quantification and identification of the active ingredient in the finished product is very attractive.  相似文献   

18.
In the complex neuronal network, chemical messengers like neuropeptides play a key role in signaling. To understand the mechanism of signaling, it is necessary to analyze the levels of neuropeptides from biological sources, which is important for neuroscience research. In the present work, a detailed investigation of the capillary zone electrophoresis (CZE) method was carried out to detect and quantify Substance P (SP), a bioactive neuropeptide, in rat brain tissues. The method involves specifically, a combination of solid phase extraction and immunoprecipitation prior to the CZE quantification. In this procedure, antibodies are used to capture the analyte of interest before the separation by CZE. Different separation parameters like buffer type, concentration, pH and applied voltage were the steps taken to study and achieve high efficiency CZE separation. CZE analysis was performed in an untreated fused-silica capillary column (35 cm×75 μm i.d.) and 185 nm wavelength using 100 mM phosphate buffer (pH 2.5) as a separation buffer. Electrophoresis in acidic mode and successive washing procedures solved the adsorption problem. The method provides a rapid analysis time of less than 15 min with 3.91% of RSD. Simultaneously, SP was quantified by Matrix Assisted Laser Desorption Ionization-Time of Flight-Mass Spectrometry (MALDI-TOF-MS) and compared with CZE data. Starting from milligram amounts of brain tissue, the method allowed the detection of low picomole amounts of SP and the combined use of CZE and MALDI-TOF-MS was a success in quantification in this study.  相似文献   

19.
Multiple response simultaneous optimization by using the desirability function was used for the development of a capillary electrophoresis method for the simultaneous determination of four active ingredients in pharmaceutical preparations: vitamins B6 and B12, dexamethasone and lidocaine hydrochloride. Five responses were simultaneously optimized: the three resolutions, the analysis time and the capillary current. This latter response was taken into account in order to improve the quality of the separations. The separation was carried out by using capillary zone electrophoresis (CZE) with a silica capillary and UV detection (240 nm). The optimum conditions were: 57.0 mmol l−1 sodium phosphate buffer solution, pH 7.0 and voltage = 17.2 kV. Good results concerning precision (CV lower than 2%), accuracy (recoveries ranged between 98.5 and 102.6%) and selectivity were obtained in the concentration range studied for the four compounds. These results are comparable to those provided by the reference high performance liquid chromatography (HPLC) technique.  相似文献   

20.
The aim of the study was to develop a new capillary zone electrophoresis (CZE) method for determination of enzymatic activity of hyaluronidase. The method permits monitoring of the process of hyaluronic acid digestion by hyaluronidase. Studies were performed using CZE instrument equipped with capillary of 64.5 cm total length, 56 cm effective length and internal diameter 75 µm. Separation was performed in the phosphate buffer (pH 8.10) in the electric field of 20 kV, λ = 220 nm. The procedure was based on mixing a known quantity of hyaluronic acid and an aliquot of hyaluronidase solution, followed by obtaining CZE profiles after a known period of incubation (0.5 h). The activity of hyaluronidase was calculated using multiple regression analysis in which sizes of the peaks of the main degradation products were used. The newly developed method was fully validated and it is appropriate to evaluate the activity of hyaluronidase originating from different sources with high precision and accuracy. t‐Tests showed that there were no significant differences between results obtained using turbidimetric, viscosimetric and the new CZE method. The developed method is characterized by a short duration of analysis, low volume of analyzed sample, small amount of buffers used and low cost of analysis. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号