首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The recent findings of antibiotic residues in aquatic environment at trace level have gained much concern for the detrimental effect on ecological and human health due to bacterial resistance. Here, the feasibility of using electrospray ionization ion mobility spectrometry (ESI-IMS) for analysis antibiotics in liquid sample is demonstrated. Reduced mobilities and collision cross sections of 18 antibiotics are experimentally measured and compared with theoretical values according to mass-mobility correlation. Gentamicin is used as an example to investigate the capability of ESI-IMS for multi-component analysis of antibiotics. Mixtures of antibiotics at different concentrations are analyzed. The estimated detection limit for amoxicillin is 0.7 mg L−1 (70 pg) and the linear range of response maintains over two orders. This method will be a potential technique for the analysis of antibiotics in aquatic environment.  相似文献   

2.
Benzodiazepines are a commonly abused class of drugs; requiring analytical techniques that can separate and detect the drugs in a rapid time period. In this paper, the two-dimensional separation of five benzodiazepines was shown by electrospray ionization (ESI) ion mobility spectrometry (IMS)-mass spectrometry (MS). In this study, both the two dimensions of separation (m/z and mobility) and the high resolution of our IMS instrument enabled confident identification of each of the five benzodiazepines studied. This was a significant improvement over previous IMS studies that could not separate many of the analytes due to low instrumental resolution. The benzodiazepines that contain a hydroxyl group in their molecular structure (lorazepam and oxazepam) were found to form both the protonated molecular ion and dehydration product as predominant ions. Experiments to isolate the parametric reasons for the dehydration ion formation showed that it was not the result of corona discharge processes or the potential applied to the needle. However, the potential difference between the needle and first drift ring did influence both the relative intensity ratios of the two ions and the ion sensitivity.  相似文献   

3.
4.
Dion HM  Ackerman LK  Hill HH 《Talanta》2002,57(6):1161-1171
The results from this study illustrate the first time electrospray ionization-ion mobility spectrometry (ESI-IMS) has been used to separate inorganic cations in aqueous solutions. Using ESI-IMS nine inorganic cation solutions were analyzed. Counter ions affected both the sensitivity and the identity of the response ions. Aluminum sulfate, lanthanum chloride, strontium chloride, uranyl acetate, uranyl nitrate, and zinc sulfate produced spectra containing a single response ion. Aluminum nitrate and zinc acetate solutions produced multiple ion peaks, which increased the detection limits and the difficulty of identification. Cation detection limits ranged from 0.16 to 13 ng μl−1 depending on the solution studied. The identities of the ion species detected were unconfirmed, but mass spectrometry literature suggested the detection of positively charged cation-solvent or cation-solvent-anion complexes. Finally, cations from strontium and lanthanum chloride solutions were separated with a resolution of 2.2. The results from this study suggest that ESI-IMS has potential as a field technique for the detection of metal cations and their complexes in the environment.  相似文献   

5.
An electrospray ionization (ESI) source was used to generate gas-phase molecular anions of the amino acids leucine and isoleucine ((M–H); m/z −130), which were separated by high- field asymmetric waveform ion mobility spectrometry (FAIMS) and detected by quadrupole mass spectrometry (MS). This combination of ESI-FAIMS-MS enabled selective determination of either amino acid in mixtures that contained at least a 625-fold excess of the other. Comparisons with conventional ESI-MS showed a 50-fold improvement in the signal to background ratio for a 1 μM solution of leucine.  相似文献   

6.
High field asymmetric waveform ion mobility spectrometry (FAIMS) provides atmospheric pressure, room temperature, low-resolution separation of gas-phase ions. The FAIMS analyzer acts as an ion filter that can continuously transmit one type of ion, independent of m/z. The combination of FAIMS with electrospray ionization and mass spectrometry (ESI-FAIMS-MS) is a powerful technique and is used in this study to investigate the cluster ions of leucine enkephalin (YGGFL). Separation by FAIMS of leucine enkephalin ions having the same m/z (m/z 556.5), [M + H]+ and [2M + 2H]2+, was observed. In addition, four complex ions of leucine enkephalin, [2M + H]+, [4M + 2H]2+, [6M + 3H]3+, and [8M + 4H]4+, all having m/z 1112, were shown to be separated in FAIMS. Fragmentation of ions as the result of harsh conditions within the mass spectrometer interface (FAIMS-MS) was shown to provide similar information to that obtained from MS/MS experiments in conventional ESI-MS.  相似文献   

7.
The Kinetic Method (KM), applied commonly for thermochemical determinations, is used here for sterically-controlled isomeric determination of N- versus C-terminal Arg-containing dipeptide isomers (ArgX versus XArg; where X = His, Leu, Lys, Pro, Ser, Phe, and Tyr). The KM is offered as an alternate approach to direct collision-induced dissociation (CID) procedures. Through formation, isolation, and dissociation of a sterically-encumbered, metal-centered complex with electrospray ionization ion trap mass spectrometry technology, reference dipeptide molecules are screened to quantitatively differentiate a mixture of isomers based on their arrangement about the metal center. Arg-containing dipeptide molecules are chosen because of their contribution in a wide array of protein and peptide functions. Additionally, problems cited previously for evaluation of systems containing Arg residues (due to the incorporation of the guanidinium moiety) by the KM are addressed. The method is shown to be successful for highlighting favorable reference analytes (e.g., ArgPhe, ArgLeu, ProArg, PheArg, among others) for exceptional discrimination (R(iso) > 2.0) of the majority of N- and C-terminal Arg-containing peptides tested.  相似文献   

8.
直接电喷雾离子阱质谱法快速表征烟叶   总被引:1,自引:0,他引:1  
建立了一种快速、简单的同时检测烟叶中多酚类和非挥发性有机酸的电喷雾离子阱质谱方法。该方法采用水溶液萃取烟叶,萃取液无需色谱柱分离提纯,直接进入质谱检测,得到烟草质谱轮廓图。采用该方法对25种不同产地、不同等级的烟叶样品进行了测量,并结合模式识别的方法,对这25种烟叶进行了聚类分析,其结果基本符合烟草专家的等级划分。最后对各类烟叶进行了统计分析,得到了表征各类烟叶的平均质谱轮廓和各特征组分对区分烟叶贡献大小。表明该方法可以用于辅助烟叶等级划分及卷烟配方设计。  相似文献   

9.
10.
The separation and ion focusing properties of High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) depend on desolvated ions entering the device, leading to a compound-specific, reproducible compensation voltage (CV) for each ion. This study shows that the conditions identified for stable spray and satisfactory ion desolvation in normal electrospray ionization mass spectrometry (ESI-MS) operation might significantly differ from those required for FAIMS-MS. In a typical setup with high-flow electrospray conditions, ions could be incompletely desolvated, resulting in the formation of unidentified clusters with differing behavior in a FAIMS environment. This causes compound-specific shifts of as much as 10 V in CV values when the mobile phase composition and/or flow rate are varied. The shifts diminish and finally disappear when the flow rate of methanol, used as mobile phase, is reduced to 40 microL/min and that of acetonitrile to 20 microL/min. The reproducibility of the observed CV was determined by scanning the CV while infusing a five-component mixture into a 400 microL/min flow of methanol or 50:50 acetonitrile/water. The relative standard deviation (RSD) for these multiple scans ranged from 0.7% to 6%. Therefore, under a constant set of experimental parameters, the CV does not shift appreciably. These observations have an impact on method development strategies. High flow rates can be used with the FAIMS device, since the CV values are reproducible, but it is likely that clusters are forming. Therefore, CV scans should be performed under conditions which mimic the chromatographic elution or flow injection analysis conditions, including matrix composition, to minimize errors in CV determination. An alternative approach is to determine the liquid flow rate at which the CV becomes compound-specific and to split the mobile phase stream accordingly. These experimental results may be specific to the setup used for this study and may not be directly applicable to other instrument FAIMS devices.  相似文献   

11.
The direct separation of isomeric glucuronide metabolites from propranolol dosed tissue extracts by differential mobility spectrometry-mass spectrometry (DMS-MS) with the use of the polar gas-phase chemical modifier acetonitrile was demonstrated. The DMS gas-phase separation was able to resolve the isomeric metabolites with separation times on the order of milliseconds instead of minutes which is typically required when using pre-ionization chromatographic separation methods. Direct separation of isomeric metabolites from the complex tissue extract was confirmed by implementing a high-performance liquid chromatography (HPLC) separation prior to the DMS-MS analysis to pre-separate the species of interest. The ability to separate isomeric exogenous metabolites directly from a complex tissue extract is expected to facilitate the drug development process by increasing analytical throughput without the requirement for pre-ionization cleanup or separation strategies.  相似文献   

12.
Recently discovered ionization methods for use in mass spectrometry (MS), are widely applicable to biological materials, robust, and easy to automate. Among these, matrix assisted ionization vacuum (MAIV) is astonishing in that ionization of low and high-mass compounds are converted to gas-phase ions with charge states similar to electrospray ionization simply by exposing a matrix:analyte mixture to the vacuum of a mass spectrometer. Using the matrix compound, 3-nitrobenzonitrile, abundant ions are produced at room temperature without the need of high voltage or a laser. Here we discuss chemical analyses advances using MAIV combined with ion mobility spectrometry (IMS) real time separation, high resolution MS, and mass selected and non-mass selected MS/MS providing rapid analyte characterization. Drugs, their metabolites, lipids, peptides, and proteins can be ionized simultaneously from a variety of different biological matrixes such as urine, plasma, whole blood, and tissue. These complex mixtures are best characterized using a separation step, which is obtained nearly instantaneously with IMS, and together with direct ionization and MS or MS/MS provides a fast analysis method that has considerable potential for non-targeted clinical analyses.  相似文献   

13.
14.
搭建了一套纳升级电喷雾-离子源离子迁移谱仪。首先,分别对尾吹气流速、溶剂流速等影响仪器去溶剂化效果的参数进行了研究和优化。在此基础上,用一系列胺类化合物对该仪器的去溶剂化效果、分辨能力以及灵敏度进行了表征。实验结果表明,该仪器能够对电喷雾离子液滴实现完全去溶剂化;三辛胺的检出限可以达到10 μg/L。最后,将该仪器用作高效液相色谱的检测器,在无需衍生化的条件下对胺类混合物样品进行检测。由三乙胺、二乙胺以及丁胺组成的混合样品被成功分离并测定。该系统对三乙胺、二乙胺以及丁胺的线性响应范围均达到近两个数量级。  相似文献   

15.
Current commercially available ion mobility spectrometers are intended for the analysis of chemicals in the gas phase. Sample introduction methods, such as direct air sampling, a GC injector or a thermal desorber, are commonly an integral part of these instruments. This paper describes an electrospray ionization ion mobility spectrometer system that allows direct introduction samples in solution phase. This allows direct analysis of non-volatile organic and biological samples, and avoids decomposition of thermally liable samples, providing reliable chemical identification. In addition, the new ion mobility spectrometer allows mobility analysis with high resolving power. Commonly used commercial IMS systems provide resolving powers between 10 and 30; this new ion mobility spectrometer has resolving power greater than 60 for routine analysis. A high resolution instrument is necessary for many applications where a complex mixture needs to be separated and quantified. This paper demonstrates the advantages of using a high resolution ion mobility spectrometer and an electrospray ionization source for the analysis of non-volatile pharmaceuticals as well as dissolved explosive in solution phase.  相似文献   

16.
The pressure dependence of sheath gas assisted electrospray ionization (ESI) was investigated based on two complementary experimental setups, namely an ESI-ion mobility (IM) spectrometer and an ESI capillary - Faraday plate setup housed in an optically accessible vacuum chamber. The ESI-IM spectrometer is capable of working in the pressure range between 300 and 1000 mbar. Another aim was the assessment of the analytical capabilities of a subambient pressure ESI-IM spectrometer. The pressure dependence of ESI was characterized by imaging the electrospray and recording current-voltage (I-U) curves. Qualitatively different behavior was observed in both setups. While the current rises continuously with the voltage in the capillary-plate setup, a sharp increase of the current was measured in the IM spectrometer above a pressure-dependent threshold voltage. The different character can be attributed to the detection of different species in both experiments. In the capillary-plate experiment, a multitude of charged species are detected while only desolvated ions attribute to the IM spectrometer signal. This finding demonstrates the utility of IM spectrometry for the characterization of ESI, since in contrast to the capillary-plate setup, the release of ions from the electrospray droplets can be observed. The I-U curves change significantly with pressure. An important result is the reduction of the maximum current with decreasing pressure. The connected loss of ionization efficiency can be compensated by a more efficient transfer of ions in the IM spectrometer at increased E/N. Thus, similar limits of detection could be obtained at 500 mbar and 1 bar.  相似文献   

17.
18.
This study shows that electrospray ionization mass spectrometry (ESI-MS), combined with a heated turbo ion-spray interface, allows monitoring protein stabilization by glycerol in solution. Measurements obtained with the two proteins lysozyme and cytochrome c are presented. The observed mass-to-charge (m/z) distributions reveal the stabilizing effect of the additive on the protein conformations against temperature and acid-induced unfolding, as well as against denaturation by acetonitrile. The data obtained with lysozyme allow detection of minor conformational changes upon glycerol addition to the native protein, and suggest that the protein structure in the presence of the additive is slightly compressed compared with its state in water. This result corroborates previous evidence obtained by nuclear magnetic resonance. It is also shown that analysis of the m/z distributions obtained by ESI-MS can lead to detection of partially folded and partially populated states in protein samples.  相似文献   

19.
This study investigated the ion mobility (IM) and the collision cross section (CCS) of fatty acids (FAs) using electrospray IM MS. The IM analysis of 18 FA ions showed intriguing differences among the saturated FAs, monounsaturated FAs, multi‐unsaturated FAs, and cis‐isomer/trans‐isomer with respect to the aliphatic tail chains. The length of aliphatic tail chain present in the ion structures had a strong influence on the differentiation of drift, while the number of double bond showed a weaker influence. The tiny drift differences between cis‐isomer and trans‐isomer were also observed. In the CCS measurements, two internal standards were involved in the mobility calibration and accuracy estimation. It insured our empirical CCS values were of high experimental precision (±0.35% or better) and accuracy (±0.25% or better). Moreover, the mass‐to‐charge ratio (m/z) – mobility plots obtained by ion mobility spectrometry with mass spectrometry analysis of FAs – was used to investigate the structural relationship between the molecules. Each series of FAs sharing a similar structure was aligned in the linear plot. Finally, the developed procedure was applied to the determination of FAs in rat adipose tissues, and it allowed the presence of 13 FAs to be confirmed with their exact masses and CCS values. These studies reveal the direct relationship between the behaviors in IM and the molecular structures and thus may provide further validations to the FA identification process. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
A combination of electrospray ionization, high-field asymmetric waveform ion mobility spectrometry, and mass spectrometry (ESI-FAIMS/MS) was used to analyze standard solutions of microcystins-LR, -RR, and -YR. The ability of FAIMS to separate ions in the gas phase reduced the amount of background in the mass spectrum without compromising the absolute signal for these microcystins. This reduction in background resulted in a ten-fold improvement in the signal-to-background ratio over conventional ESI-MS. Detection limits, using direct infusion, were determined to be 4, 2, and 1 nM for microcystins-LR, -RR, and -YR, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号