1.
Diffusion-weighted echo-planar magnetic resonance imaging is potentially of great importance as a diagnostic imaging tool; however, the technique currently suffers a number of limitations, including the image distortion caused by the eddy current induced fields when the diffusion-weighting magnetic field gradient pulses are applied. The distortions cause mis-registration between images with different diffusion-weighting, that then results in artifacts in quantitative diffusion images. A method is presented to measure the magnetic fields generated from the eddy currents for each of three orthogonal gradient pulse vectors, and then to use these to ascertain the image distortion that occurs in subsequent diffusion-weighted images with arbitrary gradient pulse vector amplitude and direction, and image plane orientation. The image distortion can then be reversed. Both temporal and spatial dependence of the residual eddy current induced fields are included in the analysis. Image distortion was substantially reduced by the correction scheme, for arbitrary slice position and angulation. This method of correction is unaffected by the changes in image contrast that occur due to diffusion weighting, and does not need any additional scanning time during the patient scan. It is particularly suitable for use with single-shot echo planar imaging.  相似文献   

2.
A hybrid strategy for geometric distortion correction of echo-planar images is demonstrated. This procedure utilizes standard field mapping for signal displacement correction and the so-called reverse gradient acquisition for signal intensity correction. (The term reverse gradient refers to an acquisition of two sets of echo-planar images with phase encoding gradients of opposite polarity.) The hybrid strategy is applied to human brain echo-planar images acquired with and without diffusion-weighting. A comparison of the hybrid distortion corrected images to those corrected with standard field mapping only demonstrates much better performance of the hybrid method. A variant of the hybrid method is also demonstrated which requires the acquisition of only one pair of opposite polarity images within a set of images.  相似文献   

3.
We evaluated two methods for correcting inhomogeneity-induced signal losses in magnetic resonance gradient-echo imaging that either use gradient compensation or simply acquire thin sections. The strategies were tested in the human brain in terms of achievable quality of T2*-weighted images at the level of the hippocampus and of functional activation maps of the visual cortex. Experiments were performed at 2.0 T and based on single-shot echo-planar imaging at 2. 0 x 2.0 mm(2) resolution, 4 mm section thickness, and 2.0 s temporal resolution. Gradient compensation involved a sequential 16-step variation of the refocusing lobe of the slice-selection gradient (TR/TE = 125/53 ms, flip angle 15 degrees ), whereas thin sections divided the 4-mm target plane into either four 1-mm or eight 0.5-mm interleaved multislice acquisitions (TR/TE = 2000/54 ms, flip angle 70 degrees ). Both approaches were capable of alleviating the inhomogeneity problem for structures in the base of the brain. When compared to standard 4-mm EPI, functional mapping in the visual cortex was partially compromised because of a lower signal-to-noise ratio of inhomogeneity-corrected images by either method. Relative to each other, consistently better results were obtained with the use of contiguous thin sections, in particular for a thickness of 1 mm. Multislice acquisitions of thin sections require minimal technical adjustments.  相似文献   

4.
A procedure is developed to quantify and improve the signal-to-noise ratio (SNR) of magnetic resonance images. The image SNR is quantified using the correlation function of two independent acquisitions of an image. To test the performance of the quantification, SNR measurement data are fitted to theoretically expected curves. The proposed correlation technique is also used to improve the SNR by estimating the amplitude of the signal spectrum. The technique is applied to a set of MR images, and its performance in terms of gain in SNR, contrast-to-noise ratio (CNR), and resolution loss is compared to that of classical noise filters. The SNR as well as the CNR is improved significantly with minor loss of resolution. Finally, it is shown that the correlation technique can be implemented in a highly efficient way in almost any acquisition procedure of a magnetic resonance imaging system.  相似文献   

5.
Functional magnetic resonance imaging (fMRI) exploits the blood oxygenation level dependent (BOLD) effect to detect neuronal activation related to various experimental paradigms. Some of these, such as reversal learning, involve the orbitofrontal cortex and its interaction with other brain regions like the amygdala, striatum or dorsolateral prefrontal cortex. These paradigms are commonly investigated with event-related methods and gradient echo-planar imaging (EPI) with short echo time of 27 ms. However, susceptibility-induced signal losses and image distortions in the orbitofrontal cortex are still a problem for this optimized sequence as this brain region consists of several slices with different optimal echo times. An EPI sequence with slice-dependent echo times is suitable to maximize BOLD sensitivity in all slices and might thus improve signal detection in the orbitofrontal cortex. To test this hypothesis, we first optimized echo times via BOLD sensitivity simulation. Second, we measured 12 healthy volunteers using a standard EPI sequence with an echo time of 27 ms and a modified EPI sequence with echo times ranging from 22 ms to 47 ms. In the orbitofrontal cortex, the number of activated voxels increased from 87±44 to 549±83 and the maximal t-value increased from 4.4±0.3 to 5.4±0.3 when the modified EPI was used. We conclude that an EPI with slice-dependent echo times may be a valuable tool to mitigate susceptibility artifacts in event-related whole-brain fMRI studies with a focus on the orbitofrontal cortex.  相似文献   

6.
Undersampled spiral CSI (spCSI) using a free induction decay (FID) acquisition allows sub-second metabolic imaging of hyperpolarized 13C. Phase correction of the FID acquisition can be difficult, especially with contributions from aliased out-of-phase peaks. This work extends the spCSI sequence by incorporating double spin echo radiofrequency (RF) pulses to eliminate the need for phase correction and obtain high quality spectra in magnitude mode. The sequence also provides an added benefit of attenuating signal from flowing spins, which can otherwise contaminate signal in the organ of interest. The refocusing pulses can potentially lead to a loss of hyperpolarized magnetization in dynamic imaging due to flow of spins through the fringe field of the RF coil, where the refocusing pulses fail to provide complete refocusing. Care must be taken for dynamic imaging to ensure that the spins remain within the B?-homogeneous sensitive volume of the RF coil.  相似文献   

7.
梯度是磁共振成像(MRI)的关键环节.通过采集谱仪梯度波形信号并进行分析,提取出各通道波形的特征点,从而有助于快速准确地判断谱仪梯度硬件电路或脉冲序列编写是否存在问题.采用虚拟仪器LabVIEW软件控制高速采集卡DAQ-2005设计实现多路采集系统,对谱仪的梯度输出进行采集.通过对波形数据进行直方图统计、滤波、差分计算等分析,提取出波形的特征点,这些特征点包含时间与幅度信息.使用实验室自主研发的谱仪进行了多次实验,对该方法进行验证,证明了该方法的有效性,也为谱仪研制和脉冲序列开发提供了一种辅助测试方法.  相似文献   

8.
With improved B 0 homogeneity along with satisfactory gradient performance at high magnetic fields, snapshot gradient-recalled echo-planar imaging (GRE-EPI) would perform at long echo times (TEs) on the order of T2*, which intrinsically allows obtaining strongly T2*-weighted images with embedded substantial anatomical details in ultrashort time. The aim of this study was to investigate the feasibility and quality of long TE snapshot GRE-EPI images of rat brain at 9.4 T. When compensating for B 0 inhomogeneities, especially second-order shim terms, a 200 x 200 microm2 in-plane resolution image was reproducibly obtained at long TE (>25 ms). The resulting coronal images at 30 ms had diminished geometric distortions and, thus, embedded substantial anatomical details. Concurrently with the very consistent stability, such GRE-EPI images should permit to resolve functional data not only with high specificity but also with substantial anatomical details, therefore allowing coregistration of the acquired functional data on the same image data set.  相似文献   

9.
Dynamic nuclear polarization of metabolically active compounds labeled with (13)C has been introduced as a means for imaging metabolic processes in vivo. To differentiate between the injected compound and the various metabolic products, an imaging technique capable of separating the different chemical-shift species must be used. In this paper, the design and testing of a pulse sequence for rapid magnetic resonance spectroscopic imaging (MRSI) of hyperpolarized (13)C is presented. The pulse sequence consists of a small-tip excitation followed by a double spin echo using adiabatic refocusing pulses and a "flyback" echo-planar readout gradient. Key elements of the sequence are insensitivity to calibration of the transmit gain, the formation of a spin echo giving high-quality spectral information, and a small effective tip angle that preserves the magnetization for a sufficient duration. Experiments in vivo showed three-dimensional coverage with excellent spectral quality and SNR.  相似文献   

10.
Functional magnetic resonance imaging (fMRI) is widely used to pinpoint active brain areas. Changes in neuronal activity modulate the local blood oxygenation level, and the associated modulation of the magnetic field homogeneity can be detected with magnetic resonance imaging. Thus, the blood oxygenation level-dependent (BOLD) fMRI indirectly measures neuronal activity. Similar modulation of magnetic field homogeneity was here elicited by other means to generate a BOLD-like change in a new phantom constructed to provide reference activations during fMRI. Magnetic inhomogeneities were produced by applying current to coils located near the phantom containing 1.5 ml of Gd-doped water. The signal-to-noise ratio of the images, produced by gradient-recalled echo-planar imaging, varied between 104 and 107 at a selected voxel when the field was and was not inhomogenized, respectively. The contrast of signals between homogeneous and inhomogeneous conditions was generally stable, except in 3% of time points. During the periods of greatest deviations an observable change would have been detected in a simultaneously measured BOLD signal. Such changes could result from the imaging method or occur through glitches in hardware or alterations in the measurement environment. With identical measurement setups, the phantom could allow comparing intersession or intersubject brain activations.  相似文献   

11.
Triple quantum filtered sodium MRI techniques have been recently demonstrated in vivo. These techniques have been previously advocated as a means to separate the sodium NMR signal from different physiological compartments based on the differences between their relaxation rates. Among the different triple quantum coherence transfer filters, the three-pulse coherence transfer filter has been demonstrated to be better suited for human imaging than the traditional four-pulse implementation. While the three-pulse structure has distinct advantages in terms of RF efficiency, the lack of a refocusing pulse in the filter introduces an increased dependence on the main magnetic field inhomogeneities, which can sometimes lead to significant signal loss. In this paper, we characterize these dependencies and introduce a method for their compensation through the acquisition of a B(0) map and the use of a modified phase cycling scheme.  相似文献   

12.
This letter describes a data acquisition setup for recording, and processing, running speech from a person in a magnetic resonance imaging (MRI) scanner. The main focus is on ensuring synchronicity between image and audio acquisition, and in obtaining good signal to noise ratio to facilitate further speech analysis and modeling. A field-programmable gate array based hardware design for synchronizing the scanner image acquisition to other external data such as audio is described. The audio setup itself features two fiber optical microphones and a noise-canceling filter. Two noise cancellation methods are described including a novel approach using a pulse sequence specific model of the gradient noise of the MRI scanner. The setup is useful for scientific speech production studies. Sample results of speech and singing data acquired and processed using the proposed method are given.  相似文献   

13.
Simultaneous electroencephalography (EEG)/functional magnetic resonance imaging (fMRI) acquisition can identify the brain networks involved in generating specific EEG patterns. Yet, the combination of these methodologies is hampered by strong artifacts that arise due to electromagnetic interference during magnetic resonance (MR) image acquisition. Here, we report corrections of the gradient-induced artifact in phantom measurements and in experiments with an awake behaving macaque monkey during fMRI acquisition at a magnetic field strength of 4.7 T. Ninety-one percent of the amplitude of a 10 microV, 10 Hz phantom signal could successfully be recovered without phase distortions. Using this method, we were able to extract the monkey EEG from scalp recordings obtained during MR image acquisition. Visual evoked potentials could also be reliably identified. In conclusion, simultaneous EEG/fMRI acquisition is feasible in the macaque monkey preparation at 4.7 T and holds promise for investigating the neural processes that give rise to particular EEG patterns.  相似文献   

14.
Single-shot line scan imaging using stimulated echoes   总被引:2,自引:0,他引:2  
A new high-speed MRI method is described for single-shot line scan imaging (LSI) based on stimulated echoes (STE). To allow for multislice imaging, the technique comprises a series of slice-selective preparation pulses (each corresponding to the first RF pulse of a STE sequence), a slab-selective refocusing pulse (second RF pulse), and multiple line-selective read pulses (third RF pulses). An alternative version employs packages of two slice-selective pulses followed by multiple line-selective read pulses. Experimental applications deal with human brain imaging on a clinical MRI system at 2.0 T. The technique offers user-selectable trade-offs between volume coverage (1-15 sections) and in-plane spatial resolution (1-5 mm linear pixel dimension) within total acquisition times of less than 500 ms. Although LSI yields a lower signal-to-noise ratio than Fourier imaging, single-shot LSI with STEs is free from resonance offset effects (e.g., magnetic field inhomogeneities and susceptibility differences) that are typical for echo-planar imaging. Moreover, the technique exhibits considerable robustness against motion and provides access to arbitrary fields-of-view, i.e., localized imaging of inner volumes without aliasing artifacts due to phase wrapping.  相似文献   

15.
优化重聚脉冲提高梯度场核磁共振信号强度   总被引:1,自引:0,他引:1       下载免费PDF全文
李新  肖立志  刘化冰  张宗富  郭葆鑫  于慧俊  宗芳荣 《物理学报》2013,62(14):147602-147602
缩短射频脉冲宽度, 有助于解决脉冲电力消耗大、样品吸收率高、信噪比低等极端条件核磁共振探测的关键问题. 本文首先分析射频脉冲角度对核磁共振自旋回波信号强度的影响机理, 基于Bloch方程推导了回波信号幅度与扳转角、重聚角的关系. 在特制核磁共振分析仪上采用变脉冲角度技术, 分别在均匀磁场和梯度磁场条件下实现对扳转角和重聚角与回波信号强度关系的数值模拟和实验测量. 结果表明, 梯度场中, 扳转角为90°、重聚角为140°的射频脉冲组合获得最大首波信号强度, 比180°脉冲对应的回波幅值提高13%, 能耗降低至78%. 选用该重聚角(140°) 优化设计饱和恢复脉冲序列探测流体的纵向弛豫时间T1特性, 准确获得 T1分布.该结果对于低电力供应、且对信噪比有较高要求的核磁共振测量, 如随钻核磁共振测井和在线核磁共振快速检测等, 具有重要意义. 关键词: 核磁共振 信号强度 重聚脉冲角度 Bloch方程  相似文献   

16.
Clinical blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is becoming increasingly valuable in, e.g., presurgical planning, but the commonly used gradient-echo echo-planar imaging (GE-EPI) technique is sometimes hampered by macroscopic field inhomogeneities. This can affect the degree of signal change that will occur in the GE-EPI images as a response to neural activation and the subsequent blood oxygenation changes, i.e., the BOLD sensitivity (BS). In this study, quantitative BS maps were calculated directly from gradient-echo field maps obtainable on most clinical scanners. In order to validate the accuracy of the calculated BS-maps, known shim gradients were applied and field maps and GE-EPI images of a phantom were acquired. Measured GE-EPI image intensity was then compared with the calculated (predicted) image intensity (pII) which was obtained from the field maps using theoretical expressions for image-intensity loss. The validated expressions for pII were used to calculate the corresponding predicted BOLD sensitivity (pBS) maps in healthy volunteers. Since the field map is assumed to be valid throughout an entire fMRI experiment, the influence of subject motion on the pBS maps was also assessed. To demonstrate the usefulness of such maps, pBS was investigated for clinically important functional areas including hippocampus, Broca's area and primary motor cortex. A systematic left/right pBS difference was observed in Broca's area and in the hippocampus, most likely due to magnetic field inhomogeneity of the particular MRI-system used in this study. For all subjects, the hippocampus showed pBS values above unity with a clear anterior–posterior gradient and with an abrupt drop to zero pBS in the anterior parts of hippocampus. It is concluded that GE field maps can be used to accurately predict BOLD sensitivity and that this parameter is useful to assess spatial variations which will influence fMRI experiments.  相似文献   

17.
The effectiveness of solid-echo and magic-echo phase-encoding solid-state magnetic resonance imaging methods was tested to determine possible improvement of sensitivity and spatial resolution for investigation of various types of solid polymers. The dipolar interaction refocusing pulse sequences have been used to elongate the possible phase-encoding period and to improve the signal sensitivity. The comparison of both dipolar refocusing techniques with conventional single point imaging method was made. The optimization of the phase-encoding time and magnetization recovery periods were performed basing on (1)H spectra and longitudinal relaxation measurements, respectively. The influence of imaging artifacts (intrinsic for each technique) on image quality was investigated. The effectiveness of the artifacts suppression methods was tested.  相似文献   

18.
In the present paper, for the first time, the feasibility to detect primary magnetic field changes caused by neuronal activity in vivo by spin-echo (SE) magnetic resonance imaging (MRI) is investigated. The detection of effects more directly linked to brain activity than secondary hemodynamic–metabolic changes would enable the study of brain function with improved specificity. However, the detection of neuronal currents by MRI is hampered by such accompanying hemodynamic changes. Therefore, SE image acquisition, rather than gradient-echo (GE) image acquisition, was preferred in the present work since the detection of primary neuronal and not blood oxygenation level-dependent (BOLD)-related effects may be facilitated by this approach. First of all, a precise spatiotemporal synchronization of image acquisition with the neuronal event had to be performed to avoid refocusing of the dephasing phenomenon during the course of the SE sequence. At this aim, we propose the combined use of visual evoked potential (VEP) recordings and BOLD-fMRI measurements prior to SE MRI scanning. Moreover, we exemplify by theory and experimentation how the control of artefactual signal changes due to BOLD and movement effects may be further improved by the experimental design. Finally, results from a pilot study using the proposed combination of VEP recordings and MRI techniques are reported, suggesting the feasibility of this method.  相似文献   

19.
Fast and quiet MRI using a swept radiofrequency   总被引:1,自引:0,他引:1  
A novel fast and quiet method of magnetic resonance imaging (MRI) is introduced which creates new opportunities for imaging in medicine and materials science. The method is called SWIFT, sweep imaging with Fourier transformation. In SWIFT, time-domain signals are acquired in a time-shared manner during a swept radiofrequency excitation of the nuclear spins. With negligible time between excitation and signal acquisition, new possibilities exist for imaging objects consisting of spins with extremely fast transverse relaxation rates, such as macromolecules, semi-solids, and quadrupolar nuclei. The field gradient used for spatial-encoding is not pulsed on and off, but rather is stepped in orientation in an incremental manner, which results in low acoustic noise. This unique acquisition method is expected to be relatively insensitive to sample motion, which is important for imaging live objects. Additionally, the frequency-swept excitation distributes the signal energy in time and thus dynamic range requirements for proper signal digitization are reduced compared with conventional MRI. For demonstration, images of a plastic object and cortical bone are shown.  相似文献   

20.
The generalized magic asymmetric gradient stimulated echo (generalized MAGSTE) sequence compensates background gradient cross-terms and can be adjusted to asymmetric timing boundary conditions which for instance are present in echo-planar MR imaging. However, its efficiency is not optimal because one of the two diffusion-weighting gradients applied in each interval usually must have a reduced amplitude to ensure the desired cross-term compensation. In this work, a modification of generalized MAGSTE is investigated where this gradient pulse is replaced by two gradient pulses with full amplitude but opposite polarities. It is shown that with these bipolar gradients (i) the sequence retains the cross-term compensation capability for an appropriate choice of the gradient pulse durations and (ii) the diffusion-weighting efficiency is improved, i.e. higher k and b values can be achieved without prolonging the echo time. These results are confirmed in MR imaging experiments on phantoms and in vivo in the human brain at 3 T using spin-echo and echo-planar MR imaging. In the examples shown, the b value could be increased between about 30% and 200% when using the bipolar gradient pulses. Thus, bipolar gradients may help to improve the applicability of the generalized MAGSTE sequence.  相似文献   