首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Summary A method is described for the determination of free chlorine, hypochlorite, chlorite and chlorate in sodium chloride brine originating from an industrial diaphragm electrolysis process. Typical analysis of the electrolysis brine: Cl2 + HOCl/OCl: 25 mmol/l; ClO2 : <0.2 mmol/l; ClO3 : 25 mmol/l. An essential part of the analysis is the treatment of the sample with an arsenite-phosphate buffer solution (pH 7) in order to prevent loss of free chlorine and undesirable decomposition of hypochlorite into chlorate. Free chlorine and hypochlorite are determined by titrating the excess of arsenite at pH 7–8 with chloramine-T in the presence of iodide. In weakly acidic solution (pH0.5)chlorite liberates iodine. The pH is brought back to 8 with hydrogen carbonate; now the iodine reacts with the arsenite and the excess of arsenite is titrated with chloramine-T (Cl2 + ClO + ClO2 ). In a 1.5 M HCl solution and at 100C also chlorate reacts with arsenite. Now the excess of arsenite is titrated in acidic solution with chloramine-T in the presence of bromide (total oxidant). The equivalence points are determined biamperometrically with two platinum electrodes (Epol=100 mV).
Biamperometrische Bestimmung von freiem Chlor, Hypochlorit, Chlorit und Chlorat in Natriumchloridsole
Zusammenfassung Das beschriebene Verfahren wird für die Analyse der Natriumchloridsole aus einem industriellen Diaphragma-Elektrolysebetrieb angewendet. Typische Analyse der Sole: Cl2 + HOCl/OCl: 25 mmol/l; ClO2 : <0,2 mmol/l; ClO3: 25 mmol/l. Ein wichtiger Teil der Analyse ist die Behandlung der Probe mit einer Arsenit-Phosphatpufferlösung (pH 7), um Chlorverluste und unerwünschte Umsetzung von Hypochlorit zu Chlorat zu verhüten. Freies Chlor und Hypochlorit werden durch Titration des Arsenitüberschusses bei pH 7–8 mit Chloramin-T in Gegenwart von Jodid bestimmt. In schwach-saurer Lösung (pH0,5) erfolgt aus Chlorit und Jodid eine quantitative Umsetzung zu Jod. Der pH der Lösung wird mit Hydrogencarbonat auf 8 gebracht; bei diesem pH-Wert reagiert Jod mit Arsenit; der Arsenitüberschu\ wird wieder mit Chloramin-T titriert (Cl2 + ClO + ClO2 ). In einer 1,5 M HCl-Lösung und bei 100C reagiert auch Chlorat mit Arsenit. Der Arsenitüberschu\ wird jetzt in saurer Lösung mit Chloramin-T in Gegenwart von Bromid bestimmt (Gesamtoxidant). Die Titrationsendpunkte werden biamperometrisch mit Hilfe von zwei Platinelektroden (Epol=100 mV) indiziert.
  相似文献   

2.
Summary A polarographic investigation on the N-benzoylphenylhydroxylamine (BPHA) complex of tin has been made in a mixture of chloroform and methanol. From the studies it has been confirmed that the complex is formed by tetravalent tin. A tentative mechanism of the oxidation of tin(II) in presence of BPHA has been suggested. Moreover, a rapid, sensitive and specific method of determination of tin in trace quantities by derivative pulse polarography has been developed. The chloroform extract can be directly subjected to polarography after addition of requisite quantities of water and methanolic lithium perchlorate. Effect of different supporting electrolytes on the system has been studied. By the described method 7×10–7 M to 2×10–5 M tin can be determined without interference from large quantities of the elements commonly associated with tin and also from a large number of other elements and complexing agents.
Polarographische Untersuchung des N-Benzoylphenylhydroxylamin-Komplexes mit Zinn und pulspolarographische Bestimmung von Zinn im Spurenbereich nach Extraktion
Zusammenfassung Eine polarographische Untersuchung des N-Benzoyl-phenylhydroxylamin (BPHA)-Komplexes mit Zinn in einer Mischung von Chloroform und Methanol wurde durchgeführt. Es konnte festgestellt werden, daß der Komplex von vierwertigem Zinn gebildet wird. Ein Mechanismus der Oxidation von Zinn(II) in Gegenwart von BPHA wird vorgeschlagen. Die entwickelte Methode eignet sich in Verbindung mit der derivativen Pulspolarographie zur schnellen, spezifischen und empfindlichen Bestimmung von Zinn im Spurenbereich. Nach Zugabe einer bestimmten Menge Wasser und methanolischer Lithiumperchloratlösung kann der Chloroform-Extrakt des Zinn-BPHA-Komplexes direkt polarographiert werden. Der Einfluß verschiedener Leitsalze wurde untersucht. Mit diesem Verfahren läßt sich Zinn im Bereich von 7×10–7 M bis 2×10–5 M in Anwesenheit großer Mengen anderer Metallionen und Komplexierungsmittel bestimmen.
  相似文献   

3.
Zusammenfassung Es wird über eine photometrische Methode berichtet, die es gestattet, Spuren von Zinn in Blei und antimonhaltigen Bleilegierungen schnell und genau zu bestimmen. Das Blei wird als Bleichlorid abgetrennt und das Filtrat fast zur Trockne eingedampft. Der Bückstand wird mit einer Lösung aus Natriumjodid (6,5 M) und Perchlorsäure (1 M) aufgenommen, aus der das Zinn selektiv mit Benzol extrahiert wird. Die photometrische Zinnbestimmung erfolgt mit dem sehr empfindlichen und fast spezifischen Reagens Hämatein. Nach dieser Methode können bis zu 2 · 10–4% Sn in Blei bestimmt werden. Die Bestimmungsgrenze bei antimonhaltigen Legierungen ist abhängig von dem Antimongehalt. Bei einer Zinnkonzentration von 1,7 · 10–2% in einer Bleilegierung mit 7% Sb beträgt die relative Standardabweichung ± 3%.
Photometric determination of tin in lead and lead alloys containing antimony
Lead is separated as lead chloride and the filtrate is evaporated almost to dryness. The residue is dissolved in a solution of sodium iodide (6,5 M) and perchloric acid (1 M), and the tin is quantitatively extracted with benzene. For its photometric determination the very sensitive and highly selective reagent haematein is used. Up to 2×10–4% tin in lead could be determined. The estimation limit in antimonial lead alloy depends upon the antimony content. With a tin concentration of 1.7×10–2% in an antimonial lead alloy containing 7% Sb, the relative standard deviation corresponds to ± 3%.
  相似文献   

4.
Summary Traces of titanium in sea water have been preconcentrated by anion-exchange from acidified samples in the presence of thiocyanate. Titanium adsorbs strongly on a column of Amberlite CG 400 (SCN) and can be stripped easily by elution with 2 M hydrochloric acid — 1.5% hydrogen peroxide solution. Titanium in the effluent is determined spectrophotometrically with diantipyrylmethane as colour reagent. The combined method allows to determine traces of titanium very selectively and sensitively in sea water as well as non-saline water on a 41 sample basis. The method yields a coefficient of variation of 7% at a titanium level of 0.4 g per l.
Kombinierte Anionenaustauscher-Trennung und spektralphotometrische Bestimmung von Titanspuren in Meerwasser
Zusammenfassung Titanspuren wurden in Gegenwart von Thiocyanat durch Anionenaustausch aus der angesäuerten Probe angereichert. Titan wird an Amberlite CG 400 (SCN) stark adsorbiert und kann durch Elution mit 2M HCl — 1,5% H2O2 leicht abgelöst werden. Im Eluat wird es spektralphotometrisch mit Diantipyrylmethan bestimmt. Die kombinierte Methode gestattet eine selektive und empfindliche Bestimmung in einer 41-Probe von Meer- oder auch Süßwasser. Für einen Gehalt von 0,4 g Ti/l beträgt der Variationskoeffizient 7%.
  相似文献   

5.
Zusammenfassung Zur Bestimmung von Zinn in armen Zinnerzen und deren Aufbereitungsabgängen wird folgender Weg vorgeschlagen:Die Kieselsäure des Roherzes wird vor einem Peroxidaufschluß mit Flußsäure abgeraucht und vorliegendes Eisen im wesentlichen als Eisenoxidaquat durch Filtration der alkalischen Aufschlußlösung entfernt. Der Rest des Eisens und alle weiteren Störelemente werden im ammoniakalischen Medium mit ÄDTA maskiert und das Zinn in Gegenwart von Beryllium mit Ammoniak als SnO2 · aq ausgefällt. Der Nederschlag wird in verd. Schwefelsäure aufgelöst und das Zinn als Zinn(IV) mit Phenylfluoron colorimetrisch bestimmt.Das angewandte Analysenverfahren ist frei von systematischen Fehlern und hat bei 95%iger statistischer Sicherheit einen Streubereich von ±0,006% (absolut) im Bereich von 0,0 bis wenigstens 0,5% Zinn.
Summary The following method is proposed for the determination of tin in poor tin ores and their dressing wastes: Silicic acid is removed from the raw ore by fuming with hydrofluoric acid, subsequently the sample is fused with sodium peroxide and iron is separated as Fe2O3 · aq by filtration of the alkaline solution of the decomposed material. Any residual iron and other interfering elements are masked by EDTA in ammoniacal medium and tin is precipitated as SnO2 · aq by ammonia in presence of beryllium. The precipitate is dissolved in diluted sulphuric acid and tin is determined as SnIV by colorimetry with phenylfluorone. The method is not liable to systematic errors. Having a confidence level of 95% the variation is ±0.006% (abs.) in the range of 0.0 to at least 0.5% of tin.


Diplomarbeit P. Gärtner 6.  相似文献   

6.
    
Zusammenfassung Die zu untersuchende zinnorganische Verbindung wird mit konz. Schwefelsäure und Wasser stoffperoxid aufgeschlossen und das Zinn mit 3-Pyridylfluoron photometrisch bestimmt. Die Genauigkeit des Verfahrens entspricht den Anforderungen der Elementaranalyse. Bei Zinngehalten von 10–70% lag der absolute Fehler im Bereich von + 0,14 bis – 0,06%.
Photometric determination of tin in organic tin compounds with 3-pyridylfluorone
3-Pyridylfluorone is used for the photometric determination of tin in organic tin compounds after decomposition with conc. sulphuric acid and hydrogen peroxide. The high accuracy of this method allows elemental analysis. With concentrations of 10–70% the absolute error was + 0.14 to –0.06%.


Für die Durchführung dieser Arbeit wurden dankenswerterweise Forschungsmittel aus dem ERP-Sondervermögen bereitgestellt.  相似文献   

7.
Zusammenfassung Die invers-voltammetrisehe Bestimmung von Zinn kann bei einem 105fachen Bleiüberschuß nach der Oxydation des Zinn-Hämateinkomplexes an einer Kohlepaste-Elektrode durchgeführt werden. Dazu wird die bleihaltige salzsaure Zinnlösung mit einer Lösung von Hämatein in Dioxan versetzt und nach einer Vorelektrolyse bei offenem Stromkreis das Voltammogramm zwischen ±0,0 und +1,0 V (GSE) aufgenommen. Das Strommaximum des Oxydationspeaks liegt bei +0,72 V. Die Peakhöhe ist bei einem 104- bis 105fachen Bleiüberschuß der Zinnkonzentration zwischen 10 und 100 ng/ml proportional. Das Bestimmungsverfahren wird an einem Bleistandard mit einem Zinngehalt von 0,005% erprobt. Die relative Standardabweichung der Analysenergebnisse beträgt 4,6%. Die Bestimmung kann auch in Gegenwart eines 105fachen Überschusses von Zink vorgenommen werden. Fe(III), Cu(II), Sb(III) und Sb(V) stören, wenn sie in zu hoher Konzentration vorhegen. — Zur Bestimmung von Blei in Gegenwart von Zinn wird Pb(II) zu Pb(IV) oxydiert, das als Bleidioxid während der Vorelektrolyse abgeschieden und durch kathodischen Spannungsablauf wieder gelöst wird. Die Bestimmung kann in Gegenwart eines 100fachen Zinnüberschusses erfolgen, wenn die Zusatzmethode angewandt wird. — Es werden einige von der üblichen invers-voltammetrischen Praxis abweichenden Besonderheiten und die Reaktionsfolgen beider Bestimmungsverfahren diskutiert.
Inverse-voltammetric determination of tin and lead in the presence of each other at the carbon-paste electrode
The inverse-voltammetric determination of tin can be carried out in the presence of a 105-fold excess of lead by oxydation of the tin hematein complex on the carbon-paste electrode. For that purpose, to the solution containing tin and lead a solution of hematein in dioxane is added and the voltammogram is recorded between 0.0 and +1.0 V (SSE). Pre-electrolysis is performed at ±0.0 V without polarizing the electrode. The peak potential of the oxydation signal appears near +0.72 V. The peak height is proportional to the concentration of tin in the range between 10 and 100 ng/ml. The determination is not disturbed by a 104- to 105-fold excess of lead and zinc. The method is applied to a standard sample of lead containing 0.005% tin. The standard deviation was 4.6%. Fe(III), Cu(II), Sb(III) and Sb(V) interfere if these elements are present in too high a concentration. — In the determination of lead in the presence of tin, Pb(II) is oxidized forming PbO2 which is deposited on the surface of the electrode and redissolved by subsequent cathodic voltage scanning. The determination of lead can be carried out by the addition technique in the presence of a 100-fold excess of tin.— The order of the reactions and some further details of both methods are discussed.


Vorgetragen auf der GDCh-Hauptversammlung in Hamburg im September 1969.  相似文献   

8.
The kinetics of the oxidation of Mo(CN) 8 4– by IO 4 has been studied in ethanol—water solvent mixtures over a temperature range of 15–35 °C. The effect of solvent composition on the reaction rate and the mechanism has been investigated. Activation parameters are given. An inner-sphere mechanism, consistent with the kinetic results, is proposed.
Kinetik der Periodat-Oxidation von Octacyanomolybdat(IV) in Ethanol-Wasser
Zusammenfassung Die Kinetik der Oxidation von Mo(CN) 8 4– mit IO4/– wurde in Ethanol—Wasser über einen Temperaturbereich von 15–35 °C untersucht. Der Effekt der Lösungsmittelzusammensetzung auf die Reaktionsgeschwindigkeit und der Mechanismus der Reaktion werden diskutiert. Die Aktivierungsparameter sind angeführt. Es wird ein Inner-Sphere-Mechanismus vorgeschlagen, der mit den kinetischen Ergebnissen konsistent ist.
  相似文献   

9.
Zusammenfassung Die Möglichkeit der gleichzeitigen Bestimmung von Niob und Zinn mit Hilfe der Polarographie wird untersucht. Es wird gefunden, daß die Bestimmung zwar nicht gleichspannungspolarographisch, wohl aber square-wave-polarographisch durchführbar ist. Zur Analyse der binären Nb-Sn-Legierungen (etwa Nb3Sn) ist 8,0±0,1 m HCl+10 Vol-% Äthylenglykol als Grundelektrolyt geeignet. In diesem Elektrolyten erscheinen die erste Reduktionswelle des Niobs, NbVIV, und die zweite Reduktionswelle des Zinns, SnIISn, gut getrennt und vermeßbar. Die Differenz der Spitzenpotentiale (E pNbV/IV= -0.26V, E pSnII/O= -0.46V gegen Quecksilber-Bodenelektrode) beträgt 200 mV.Die beschriebene Methode hat im Vergleich zu den bekannten nichtpolarographischen Analysenvorschriften den Vorzug, eine bis zu 100 mal kleinere Einwaage (bei vergleichbarer Reproduzierbarkeit) und einen verringerten Zeitaufwand zu erfordern.Bei Einwaagen von 2–14 mg beträgt die Genauigkeit der Niobbestimmung 1% rel., die der Zinnbestimmung 2% rel. Eine einzelne Niob-Zinn-Simultanbestimmung dauert 4 Std.
Summary The possibility of a simultaneous polarographic determination of niob and tin is investigated.It has been found that the determination cannot be carried out by direct current polarography, but square-wave polarography yields good results.8.0±0.1 M HCl+10 vol-% ethylene glycol is suitable as supporting electrolyte for the analysis of the binary Nb-Sn-alloys (Nb3Sn).In this supporting electrolyte the first reduction-wave of niobium NbVNbIV, and the second reduction wave of tin, SnIISn0, are well developed and separated. The difference of the peak potential (E pNbV/IV= -0.26V, E pSnII/O= -0.46V vs. mercury-pool electrode) is 200 mV. Compared with conventional methods the method described has the advantage of requiring smaller amounts of sample (up to 100 times smaller by weight at comparable reproducibility) with a saving of time.With sample amounts of 2 to 14 mg the accuracy of the niobium determination is 1% rel., that of the tin determination is 2% rel. One single simultaneous determination of niobium and tin takes about four hours.


Herrn Prof. Dr. M. von Stackelberg zum 70. Geburtstag gewidmet.  相似文献   

10.
Zusammenfassung Herstellung und Anwendung gepackter Capillarsäulen (innerer Durchmesser: 0,3 mm) zur analytischen Trennung von Kationen durch Komplexelution im Mikromaßstab werden beschrieben. Als Säulenpackung dienen Kugeln eines stark sauren Kationenaustauschers mit einem mittleren Durchmesser von 25 . Die Detektion der getrennten Kationen erfolgt kontinuierlich im Effluent mit Hilfe einer amperometrischen Mikromeßzelle. Die Trennleistung einer 125 mm langen Capillarsäule wird am System Ni2+/Co2+/Iminodiessigsäure gezeigt. Die dosierten Probemengen liegen in der Größenordnung von 5–12 g je Kation.
Summary Preparation and application of packed capillary columns (interior diameter: 0.3 mm) for analytical separations of cations in micro-scale by means of complex elution are described. The capillary columns are filled with spherical grains in the range of 25 .The detection of separated cations in the effluent is performed by means of an amperometric micro-cell.The separation efficiency of a capillary column (length: 125 mm) is shown for the system Ni2+/Co2+/iminodiacetic acid. The injected quantities of samples are in the range of 5–12 g per cation.


Herrn Dr. habil. K. Wetzel danken wir für Anregungen und Diskussionen, den Herren W. Rose und K. Rupprecht für praktische Unterstützung bei der vorliegenden Arbeit.  相似文献   

11.
Zusammenfassung Bei der Bestimmung sehr kleiner Zinngehalte ( 10–3%) in Eisen und StÄhlen ist vor der Extraktion des Zinn(IV)-jodids mit Benzol eine Abtrennung des Eisens erforderlich. Diese Abtrennung wird bei 1 m Eisen(III)-lösungen aus 10,5 n SalzsÄure mit 2,5 m Tributylphosphatlösung in Benzol durchgeführt. Dabei wird Eisen(III) zu 99,0%, Zinn dagegen nicht me\bar extrahiert. Bei der photometrischen Endbestimmung des Zinns erwies sich nach überprüfung mehrerer Verfahren die Bestimmung mit HÄmatein als die genaueste. Die relative Standardabweichung in Kontrollproben betrÄgt 1,7%.
Summary In the determination of very small tin concentrations ( 10–3%) in iron and steel it is necessary to separate iron before the extraction of tin(IV) iodide with benzene. For a 1 M iron(III) solution in 10.5 N hydrochloric acid the iron separation is carried out with a 2.5 M solution of tributylphosphate in benzene. Under these conditions iron(III) is extracted for 99% but tin is not measurably extracted. Among the numerous procedures for the photometric determination of tin, the method using haematein was found to be the most accurate. The relative standard deviation in test samples was 1.7%.
  相似文献   

12.
Summary Tin(IV), in the presence of cetyldimethylbenzylammonium chloride (CDBA), forms with Pyrogallol Red (PR) a complex SnPR-CDBA. This complex floates at the interface between hexane and aqueous medium. It dissolves in acetone and can be advantageously used for the determination of tin. The molar absorptivity is 6.5×104 l·mole–1·cm–1 at 480 nm. The method is selective when citric acid is used as masking agent. Phosphate, fluoride, EDTA, nitrite and sulphide interfere.
Zusammenfassung Zinn(IV) bildet mit Pyrogallolrot (PR) in Gegenwart von Cetyldimethylbenzylammoniumchlorid (CDBA) einen Komplex. Dieser wird flotiert, in Aceton gelöst und zur Bestimmung von Zinn verwendet. Der molare Absorptionskoeffizient bei =480 nm beträgt =6,5·104 l·mol–1 cm–1. Die Methode ist selektiv, wenn Zitrate zur Maskierung verwendet werden. Es stören Phosphat, Fluorid, ÄDTA, Nitrit und Sulfid.
  相似文献   

13.
Zusammenfassung Die magnetischen, spektralen und strukturellen Eigenschaften des gemischten Amminkomplexes [Fe(II)py 2 phen(NCS)2] werden diskutiert. Der Orbitalparamter liegt mit 11 700 cm–1 nahe der Spinpaarungsenergie für den mittleren kovalenten Fall 11 000 bis 12 000 cm–1 und erlaubt so ein Spingleichgewicht zwischen den Spektralzuständen5T21A1. Dieses Gleichgewicht wird durch magnetische Messungen bei verschiedenen Temperaturen nachgewiesen.
On the spin equilibrium5T21A1 in [Fe(II)py2phen(NCS)2]
The magnetic, spectral and structural properties of the mixed ammine [Fe(II)py 2 phen(NCS)2] are discussed. The orbital parameter of about 11 700 cm–1 near to the spin-pairing energy for the mean covalent case 11 000 to 12 000 cm–1 allows a spin equilibrium between the spectral states5T21A1, put in evidence by the magnetic measurements at different temperatures.


Mit 3 Abbildungen

Herrn Prof. Dr.H. Nowotny gewidmet.  相似文献   

14.
Summary The conditions for the formation of a rhodium compound with tin(II) and Rhodamine 6G, in HCl medium, and their flotation with organic solvents of low polarity have been examined. The effect of the organic solvent on the flotation has been observed. The compound with Rhodamine 6G, separated and washed, is dissolved in acetone. The acetone solution is a basis of the developed sensitive and precise flotation-spectrophotometric method. The molar absorptivity in this method is 4.0×105 at 530 nm. Beer's law is obeyed in the concentration range 0.04–0.5g Rh/ml. The components molar ratios in the isolated compound were determined, and the formula [(R6G+)3Rh(SnCl3 )4]·[(R6G+)(SnCl3 )] was proposed. The effect of the other platinum metals on the determination of rhodium with Rhodamine 6G was examined.
Flotation und spektrophotometrische Bestimmung von Rhodium mit Zinn(II)cblorid und Rhodamin 6G
Zusammenfassung Die Bildung einer Rhodiumverbindung mit Sn(II) und Rhodamin 6G in salzsaurem Medium und deren Flotation mit organischen Lösungsmitteln geringer Polarität wurden untersucht. Der Einfluß des organischen Lösungsmittels auf die Flotation ist sicher. Die Verbindung mit Rhodamin 6G wurde abgetrennt, gewaschen und in Aceton gelöst. Diese Lösung bietet die Grundlage für die ausgearbeitete genaue spektrophotometrische Methode. Die molare Absorptivität beträgt 4,0×105 bei 530 nm. Im Konzentrationsbereich 0,04–0,5g Rh/ml wird das Beersche Gesetz befolgt. Die Bestimmung des Verhältnisses der Komponenten ergab als Formel [(R6G+)3Rh(SnCl3 )4]·[(R6G+)(SnCl3 )]. Der Einfluß anderer Platinmetalle auf die vorgeschlagene Bestimmungsmethode wurde untersucht.


This work was supported by Research Program MR-I-32.  相似文献   

15.
Zusammenfassung Es werden die Absorptionsspektrogramme der Trialkyle (C1-C4) der Elemente Ga, In und Sb im Wellenzahlbereich von 4000-300 cm–1 (2,5–33 Wellenlänge) gezeigt. Das große Massenverhältnis der drei in jedem der betrachteten Moleküle vorhandenen Atomarten bewirkt, daß nur eine schwache Kopplung zwischen den einzelnen Schwingungsformen besteht, wodurch die Zuordnung der Absorptionen zu den Schwingungen einzelner Atomgruppen im Molekül ermöglicht wird.Die C-H-Absorptionen sind vom Zentralatom weitgehend unabhängig und für die Art des Alkylrestes charakteristisch.Aus den Lagen der Metall-Kohlenstoff-Absorptionen ( Ga-C540 cm–1, In-C470 cm–1, Sb-C500 cm–1) lassen sich die Kraftkonstanten dieser Bindungen abschätzen. Bei den Isobutyl-Verbindungen liegen diese Absorptionen um etwa 100 cm–1 höher als bei den anderen Gliedern der Reihe, was auf eine höhere Kraftkonstante der Metall-Kohlenstoff-Bindung dieser Verbindungen zurückgeführt wird.Die Spektrogramme werden zur Prüfung der Substanzen auf Reinheit sowie Feststellung eingetretener Veränderungen herangezogen. Bei thermischer Belastung der Isopropylverbindungen tritt zwar Zersetzung der Substanzen aber keine Isomerisierung der Alkylreste ein.Den Herren Dr. R. Dötzer, Dr. F. Engelbrecht, Dr. G. Raab und Dr. E. Todt bin ich für die Bereitstellung der Substanzen und für wertvolle Diskussionen zu Dank verpflichtet. Herrn Dr. E. Golling danke ich sehr für die Überlassung Ramanspektroskopischer Daten. Mein Dank gilt ferner Fräulein E. Vierhus und Herrn W. Regelsberger für die Aufnahme und Auswertung der Spektrogramme.  相似文献   

16.
Summary 3-Hydroxychromone reacts with tin(IV) to produce 11 complex in a weakly acidic-neutral medium. The complex exhibits intense fluorescence. A sensitive method is described for the fluorometric determination of tin(IV) with 3-hydroxychromone. The calibration graph is linear in the range of 0.4–8.0g/25 ml of tin(IV) (pH 4.5–5.0, Excitation wavelength: 365 nm, Measured total fluorescence). Chloride which generally decreases the fluorescence intensity in the fluorometric determination of tin can be tolerated at 300-mg level.
Fluorometrische Bestimmung von Zinn(IV) mit 3-Hydroxychromon
Zusammenfassung 3-Hydroxychromon reagiert mit Zinn(IV) in schwach saurem bis neutralem Medium unter Bildung eines 11-Komplexes. Dieser fluoresziert intensiv. Ein empfindliches Verfahren zur Bestimmung von Sn(IV) auf dieser Grundlage wurde ausgearbeitet. Die Eichkurve verläuft in dem Gebiet zwischen 0,4 und 8,0g Sn/25 ml bei pH 4,5, einer Wellenlänge von 365 nm und bei Messung der Gesamtfluoreszenz geradlinig. Chloride, die die Fluoreszenzintensität bei Zinnbestimmungen im allgemeinen herabsetzen, können bis zu 300 mg toleriert werden.
  相似文献   

17.
Zusammenfassung Eine schnelle spektrochemische Methode zur Bestimmung von Mikrogramm-Mengen von Silber, Blei, Zinn, Arsen, Tellur und Wismut in Eisen und Stählen wurde ausgearbeitet. Die spektrographische Analyse wird nach dem Auflösen der Probe in Salpetersäure und dem Eindampfen der Lösung zur Trockne durchgeführt. Die Methode beruht auf der Anwendung eines Siliciumdioxid-Kaliumnitrat-Puffers, der die Verdampfung der zu bestimmenden Elemente erhöht und gleichzeitig die Verdampfung des Eisens so verzögert, daß seine Störung vollständig ausgeschaltet wird. Antimon(III)-oxid dient als innerer Standard. Genauigkeit und Reproduzierbarkeit sind gut.
Spectrochemical determination of trace elements in iron and steelPart 1. Application of a buffer
A spectrochemical method has been worked out for the rapid determination of microgram quantities of silver, lead, tin arsenic, tellurium and bismuth in iron and steel. The spectrographic analysis is carried out after dissolution of the sample in nitric acid and evaporation of the solution to dryness. The method makes use of a silicon dioxide/ potassium nitrate buffer which increases the volatility of the elements to be determined and at the same time causes such a delay in the volatility of iron that its interference is fully eliminated. Antimony(III) oxide serves as an internal standard. Accuracy and precision are good.


Die in der Literatur beschriebenen Verfahren zur spektrochemischen Bestimmung von Spurenelementen in Gußeisen und Stahl beruhen auf chemischer Voranreicherung nach Auflösen in Säure. Livic u. Mosova [3] fällen die Hydroxide mit Ammoniak und dampfen die Lösung zur Trockne ein. Aus dem Trockenrückstand werden Briketts von 6 mm gepreßt, die in 2 Stufen abgebrannt werden. Zur Bestimmung der leichtflüchtigen Spurenelemente wird das Brikett anodisch geschaltet, die entstehende Schmelze wird dann zur Bestimmung der schwerflüchtigen Komponenten als Kathode geschaltet. Die Bestimmungsgrenze liegt dabei je nach Element zwischen 2 · 10–3 und 5 · 10–4%.Balfour und andere [1] bestimmen Silber, Arsen, Wismut und andere Elemente in niedrig legierten Stählen und Eisenlegierungen durch Auflösen der Probe und Zugabe von Kupfernitrat als innerer Standard mit nachfolgender Behandlung der Lösung mit Schwefelwasserstoff. Der entstehende Niederschlag wird bei 500°C geglüht, in die Bohrung einer Graphitelektrode gebracht und im Gleichstrombogen von 5 A angeregt. Zur Aufnahme der Spektren dient ein hochauflösender Spektrograph.Ein komplizierterer chemischer Bearbeitungsgang wurde für ein Aerosol-Funken-Verfahren von Répás, Sajo u. Gegus [6] vorgeschlagen. Diese Autoren bestimmen Aluminium, Arsen, Blei, Wismut und Silber in Eisen und Stahl mit Bestimmungsgrenzen zwischen 2 · 10–3 und 1 · 10–4% bei Untergrundkorrektur. Das Verfahren erfordert eine Vorabtrennung von Kieselsäure und die Extraktion des Eisens.  相似文献   

18.
    
Zusammenfassung Zur extraktionsphotometrischen Zinnbestimmung in Mo-haltigen Stählen wird Zinn nach Lösen der Stahlprobe in einem Gemisch aus Schwefelsäure und Perhydrol als SnJ4 mit Benzol extrahiert, anschließend in eine wäßrige Lösung überführt und mit 3-Pyridylnuoron photometrisch bestimmt. Bei einer Einwaage von 1000 mg lassen sich noch Gehalte von 3 · 10–4% messen, ohne daß Molybdän stört. Die Standardabweichungen betrugen ± 0,001 bis ± 0,00002%.
Extractive-photometric determination of tin in Mo-containing steels with 3-pyridylfluorone
The steel sample is dissolved in a mixture of sulphuric acid and hydrogen peroxide. Tin is extracted as SnI4 with benzene and determined photometrically with 3-pyridylnuorone. 3×10–4% of Sn can still be determined in a 1000 mg sample without interference of molybdenum. Standard deviations were within the range of ± 0.001 to ± 0.00002%.


Für die Durchführung dieser Arbeit wurden dankenswerterweise Forschungsmittel aus dem ERP-Sondervermögen bereitgestellt.Dem Verbande der Chemischen Industrie und der Deutschen Forschungsgemeinschaft, die diese Arbeit unterstützt haben, danken wir bestens.  相似文献   

19.
Zusammenfassung Es wird eine Goldbestimmung an sulfidischen Erzen für den Bereich von 0,05–5 ppm bei 20 g Einwaage beschrieben. Das Gold wird durch Salpetersäurebehandlung von den übrigen Metallen getrennt, mit Salzsäure/ Salpetersäure gelöst und mit Selen als innerem Standard und Tellur als Spurenfänger mittels Zinn(II)-chlorid gefällt. Der Niederschlag wird auf ein Membranfilter aufgezogen. Die Goldbestimmung erfolgt über den Impulsratenquotienten der Gold L- und Selen K-Linien. Die störende Molybdän K-Strahlung und die Comptonstreuung werden durch ein Zirkoniumblech auf dem Röhrenfenster unterdrückt. Der Variationskoeffizient beträgt 20% für 0,2–5 ppm und 53,6% für 0,05 ppm.
Summary A method is described for the determination of gold in sulphide ores within the concentration range of 0.05–5 ppm with sample weights of 20 g. Gold is separated from the other metals by treatment with nitric acid, dissolved by hydrochloric acid, containing some nitric acid, and is finally precipitated by stannous chloride applying selenium as internal standard and tellurium as collecting agent. The precipitate is mounted on a diaphragm filter and the determination of gold is carried out by X-ray analysis suppressing the disturbing Mo K radiation and compton scattering by a zirconium sheet-metal on the X-ray tube. The pulse rate quotient of the lines Au L /Se K is a function of the concentration of gold. The variation coefficient is 20% for 0.2–5 ppm and 53.6% for 0.05 ppm.


Herrn Prof. Dr.-Ing. habil. J. Hesemann zum 65. Geburtstag gewidmet.  相似文献   

20.
Zusammenfassung Die vorgeschlagene spektrophotometrische Methode beruht auf der Reaktion von Triphenyltetrazoliumchlorid (TTC) mit dem Thiocyanatokomplex des Kobalts(II). Bleilegierungen werden in Salpetersäure gelöst, das Blei mit Natriumchlorid gefällt und durch Abfiltrieren entfernt. Das Kobalt wird mit TTC und Thiocyanat in (TT)2 [Co(CNS)4] übergeführt, mit Chloroform extrahiert und unter Verwendung eines gelben Lichtfilters photometriert.Das Beersche Gesetz ist in den Grenzen 2–100g Co erfüllt. Die Bestimmung wird in Gegenwart von Ascorbinsäure und Thiosulfat durchgeführt und durch Ag+, Fe3+, Cu2+, Ni2+, Hg2+, Mo4+ und Zn2+ nicht gestort.Der mittlere Relativfehler der Methode ist 5,60%.
The photometric determination of cobalt in lead alloys
Summary The proposed spectrophotometric method is based on the reaction of triphenyltetrazolium chloride (TTC) with the thiocyanato complex of cobalt(II). Lead alloys are dissolved in nitric acid, the lead is precipitated with sodium chloride and removed by filtration. The cobalt is converted into (TT)2 [Co(CNS)4] by means of TTC and thiocyanate, extracted with chloroform and photometrized with employment of a yellow light filter.Beer's law is valid between the limits 2–100g CO. The determination is conducted in the presence of ascorbic acid and thiosulfate and there is no interference by Ag+, Fe3+, Cu2+, Ni2+, Hg2+, Mo4+ and Zn2+.The mean relative error of the method is 5.60%.