首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A fast and simple micellar electrokinetic capillary chromatographic method was developed for the analysis of piribedil in pharmaceutical formulations. The effects of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, applied voltage and injection time were investigated. Optimum results were obtained with a 50 mM borate buffer at pH 8.0 containing 50 mM SDS by using a fused silica capillary (50 m internal diameter, 72 cm effective length). The sample was injected hydrodynamically for 4 s at 50 mbar pressure and the applied voltage was +30 kV. The detection wavelength was set at 205 nm. Diflunisal was used as an internal standard. The analysis was performed at 25 °C and the total run time was 14 min. The method was suitably validated with respect to linearity range, limit of detection and quantification, precision, accuracy, specificity and robustness. The linear calibration range was 5–100 g mL–1 and the limit of detection was determined as 1 g mL–1. The method developed was successfully applied to the determination of piribedil in pharmaceutical formulations. The results were compared with a spectrophotometric method reported in the literature and no significant difference was found statistically.  相似文献   

2.
3.
Summary Computer-assisted procedures for the one-parameter optimization of the surfactant concentration and the concentration of urea or D-glucose as modifiers in micellar electrokinetic capillary chromatography have been developed. These procedures permit a rapid optimization of one parameter on the basis of only two experiments. Predicted values are compared to empirically obtained optimum values. The influence of the modifier concentration on the critical micelle concentration of sodium dodecyl sulfate was experimentally determined in buffers commonly employed in micellar electrokinetic chromatography. The alteration of retention factors of solutes caused by the influence of urea addition on the critical micelle concentration of sodium dodecyl sulfate was calculated under the assumption of constant distribution coefficients and compared to experimentally obtained values. It was demonstrated that the addition of urea or of D-glucose does not alter the phase ratio substantially.  相似文献   

4.
Micellar electrokinetic capillary chromatography (MEKC) was performed at 25 °C and 30 kV (under a pressure of 15 mbar), using 30 mM borate buffer containing 60 mM sodium dodecysulfate (SDS) and 5% (v/v) methanol as background electrolyte (pH 9.0) to determine doxycycline. UV detection was at 350 nm. The method was shown to be specific, accurate (recovery was 100.3 ± 1.0%), linear over the tested range (correlation coefficient 0.9995) and precise (RSD <1.9%). The method was used to determine doxycycline in tablets, capsules and human urine after oral application.  相似文献   

5.
6.
Summary A sensitive and selective laser-induced luminescence detection scheme for orotic acid in urine, separated by micellar electrokinetic capillary chromatography (MEKC) has been developed. The 325 nm line from a helium cadmium laser is used to excite orotic acid, which transfers its energy to terbium. Resultant luminescence of terbium is linear with orotic acid concentration over more than 2.5 orders of magnitude. This novel and practical system enables the detection of 50 nm orotic acid in urine in less than 1.5 minutes while using only nanoliters of sample. The significant decrease in analysis time over traditional methods (spectrophotometric and chromatographic) comes from the high efficiency of MEKC. A dramatic improvement in sensitivity and selectivity over UV detection in capillary electrophoresis is achieved through the use of laser-induced lanthanide ion energy transfer luminescence detection. Finally, no sample pretreatment is needed and the method is free from any known interferences in urine.  相似文献   

7.
Summary The separation of seven analogous anabolic steroids was studied by micellar electrokinetic capillary chromatography (MECC). The retention order was found to be dependent on polarity. All of these steroids were well separated by the addition of organic modifiers to the separation buffer. Of the organic modifiers tested, 1-propanol gave the best separation, better than methanol or acetonitrile.  相似文献   

8.
Validation of analytical procedures is important for their efficient and reliable application. The International Conference on Harmonisation (ICH), Food and Drug Administration (FDA) and pharmacopoeia guidelines achieved a great deal in harmonising the definitions of the required validation characteristics. It is well known that poor reproducibility limits the practical implementation of capillary electrophoresis (CE). A precision study on four different MEKC methods was performed with 11 samples, containing seven antibiotics, by two analysts, in few days, on two capillary electrophoresis instruments. Five pharmaceutical preparations and three animal feeds were used. Precision was statistically analysed using migration time, peak area and height of each compound, as well as electroosmotic front (EOF). In 25 of 31 cases, the reproducibility of peak area, peak height and migration time was good (<5%). In most cases the reproducibility of peak area was much better than the reproducibility of peak height. The worst reproducibility that we observed was 12.7% for peak height and 7.6% for peak area.  相似文献   

9.
The improvement and performance of a micellar electrokinetic capillary chromatography assay for cefepime in human serum and plasma with a 50 μm id fused‐silica capillary elongated from 40 to 60 cm is reported. Sample preparation with dodecylsulfate protein precipitation at pH 4.5, the pH 9.1 separation medium, and the applied voltage were as reported previously [16]. The change resulted in a significant lower current, higher resolution, and increased detection time intervals. The performance of the assay with multilevel internal calibration was assessed with calibration and control samples. Quality assurance data of a 2‐year period assessed under the new conditions demonstrated the robustness of the assay. In serum samples of patients who received both cefepime and sulfamethoxazole, cefepime could not be detected due to the inseparability of the two compounds. The presence of an interference can be recognized by an increased peak width (width > 0.2 min), the appearance of a shoulder or an unresolved double peak. The patient data gathered during a 3‐year period reveal that introduction of therapeutic drug monitoring led to a 50% reduction of the median drug level. The data suggest that therapeutic drug monitoring can help to minimize the risk of major adverse reactions and to increase drug safety on an individual basis.  相似文献   

10.
The migration characteristics of poly(4-vinylpyridine 1-oxide) (PVP-NO) in phosphate buffers of acidic pH (20 mM H3PO4 or NaH2PO4) have been studied using both free-solution capillary electrophoresis (FSCE) and MEKC. To inhibit adsorption, 250 mM o-phosphoethanolamine (2-aminoethyl dihydrogen phosphate) was used. In FSCE, PVP-NO showed a narrow peak and a broader band, both having anionic behavior. These peak and band were attributed to the free and aggregated or micellized PVP-NO forms, respectively. According to surface tension measurements, the CMC of SDS in the BGE was 1.8 and 0.48 mM in the absence and in the presence of 1000 microg/mL PVP-NO, respectively, and the association of the polymer with SDS was completed at 9.7 mM SDS. Using MEKC, a narrow peak and a broader band also appeared at SDS concentrations of ca. 1 mM, and their intensity increased with the SDS concentration. These peak and band were attributed to the formation of mixed micelles constituted by both free PVP-NO/SDS and aggregated PVP-NO/SDS, respectively. The determination of PVP-NO by FSCE in commercial additives for laundry was demonstrated.  相似文献   

11.
Pesticide analysis by micellar electrokinetic capillary chromatography   总被引:2,自引:0,他引:2  
On-capillary sample concentration using sample stacking for the improvement of detection limits for various pesticides separated by micellar electrokinetic capillary chromatography was examined. The dependence of the stacking on different parameters was investigated. An approximately 30-fold preconcentration was achieved by applying sample stacking. Employing a two-step enrichment process (solid-phase extraction combined with sample stacking), detection limits were improved and the sample volume for SPE was reduced. In addition, the total time for the analysis was considerably reduced. Detection limits were between 0.01 and 0.1 ng/ml under these enrichment conditions.  相似文献   

12.
采用胶束扫集毛细管电动色谱技术,建立了测定药物中邻苯二甲酸二甲酯(DMP)、邻苯二甲酸二乙酯(DZP)和邻苯二甲酸二丁酯(DBP)的方法。电泳缓冲体系含80 mmol/L SDS,20 mmol/L NaH2PO4(pH 2.20),5%甲醇(V/V),分离电压-18 kV,重力进样80s×15.0cm,检测波长225 nm,使用Φ50μm×62.0 cm石英毛细管,有效长度50.0 cm。讨论了磷酸盐浓度、有机改善剂、SDS浓度、分离电压、进样时间等因素的影响,并考察了胶束扫集法对DMP、DEP和DBP的富集能力。在优化条件下,线性关系良好,相关系数大于0.9986,DMP、DEP和DBP的线性范围分别为1.25~240,1.04~200和1.56~200 mg/L,检出限分别为0.26,0.26和0.39 mg/L。方法应用于肠溶片中DMP、DEP和DBP的测定,回收率在93.3%~108%之间,RSD≤5.2%。每次样品测定可在10 min内完成。  相似文献   

13.
14.
Summary Two modes of capillary electrophoresis (CE), capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC), were investigated for the separation of 12 aromatic sulphonate compounds. In CZE, although the voltage applied, the buffer concentration and the pH were optimized for effective separation of the compounds studied, under the best conditions four of the five amino compounds coeluted, as did naphthalene-1-sulphonic acid and naphthalene-2-sulphonic acid. In MEKC, sodium dodecyl sulphate (SDS) and Brij 35 were chosen as the anionic and nonionic surfactants and the effect of the concentration of micelles was examined. The effect of adding methanol as the organic modifier was also investigated with each of these micellar systems. All the analytes, including the isomers, were completely separated by use of MEKC with Brij 35 but when SDS was used only 11 compounds were separated because two amino compounds coeluted.  相似文献   

15.
Summary There is no proportional correlation between increasing organic solvent polarity from hexane to methanol and the extractability of propolis solids by the solvents or the bactericidal action of the propolis extracts obtained. Hexane (17.7%) and chloroform (62.1%) were the poorest and the best extractants, respectively, for propolis solids. The antibiotic activity of the extracts againstStaphylococcus strains decreased in the order hexane≥ethanol>methanol. Different capillary GC profiles were obtained for persilyl derivatives of propolis extracted with hexane and methanol and for propolis collected in different Brazilian provinces, suggesting the influence of flora variability on propolis composition. Wavelength-selected DAD detection revealed MEKC to be an innovative and sensitive method for monitoring the occurrence in propolis of the flavonoids and phenolcarboxylic acids thought to be responsible for the antimicrobial activity of propolis.  相似文献   

16.
A sensitive method for simultaneous determination of six phenolic whitening agents,including arbutin, phenol,resorcinol,hydroquinone,kojic acid,and salicylic acid in cosmetics has been developed using micellar electrokinetic capillary chromatography with amperometric detection(MECC-AD).Effects of several factors,such as the pH value and concentration of running buffer,potential applied to the working electrode,separation voltage,and injection time were investigated to obtain optimum conditions for separation and detection.With a 75 cm long fused-silica capillary tube,well-defined separation of six phenolic compounds was achieved in 10mmol/L SDS/40 mmol/L H3BO3-Na2B4O7 running buffer(pH 9.0).Good linear relationship was obtained for each analyte over three orders of magnitude with correlation coefficients(r2) between 0.9985 and 0.9994,and the detection limit(S/N=3) ranged from 0.04μg/mL to 0.45μg/mL The proposed method has been successfully applied for the determination of phenolic whitening agents in real cosmetic samples with satisfactory results,providing an alternative monitoring method for cosmetics safety regulation.  相似文献   

17.
18.
A capillary electrophoretic method was developed using micellar electrokinetic capillary chromatography (MEKC) with diode-array detection to analyze simultaneously 26 beer constituents in a single procedure, including alcohols, iso-alpha-acids, amino acids, flavonoids, isoflavonoids, a vitamin, purine and pyrimidine bases. After filtration, sample components were separated with an uncoated capillary and a 25 mM sodium borate and 110 mM SDS buffer at pH 10.5. Analyses were run at 14 kV and 8 s of hydrodynamic injection with UV detection at 210 nm and 270 nm. The proposed method was successfully applied to the direct determination of beer constituents without any sample cleanup procedures.  相似文献   

19.
Wang XK  He YZ  Qian LL 《Talanta》2007,74(1):1-6
A simple and convenient method of micellar electrokinetic capillary chromatography (MEKC) using polyoxyethylene sorbitan monolaurate (Tween 20) to form single micelle and methanol as a buffer additive was introduced for the simultaneous determination of five polyphenols, including scopoletin, rutin, esculetin, chlorogenic acid and caffeic acid. A running buffer solution of pH 9.3, 20 mmol/L sodium tetraborate containing 64 mmol/L Tween 20 and 9% (v/v) methanol was adopted in the separation. Because rutin and esculetin were difficult to be separated by capillary zone electrophoresis (CZE) and SDS-based MEKC, Tween 20-based MEKC was adopted and the polyphenols were separated satisfactorily. The proposed method was used to determine the polyphenol components in the herbal medicine of Cortex fraxini. The separation mechanism of Tween 20-based MEKC for the polyphenols was discussed preliminarily.  相似文献   

20.
The use of micellar electrokinetic capillary chromatography (MECC) for the analysis of the major nucleobases, nucleosides, and nucleotides, and their chemically modified derivatives, has been developed and refined. The dimensions of the separating capillaries, the composition of the buffering systems, and the conditions used for electrophoresis were investigated in order to obtain the best performance. Particular emphasis was placed on the identification of the physiological constituents of nucleic acids and their chemically modified analogs: in vitro studies on calf thymus DNA exposed to genotoxic agents have demonstrated that adducted bases and nucleolides can be identified by MECC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号