首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 444 毫秒
1.
Recent regulation in Japan requires more sensitive trace analysis methods for the determination of arsenic and selenium and their oxidation states As(III) and (V), Se(IV) and (VI). The hydride generation (HG) technique is usually used in combination with AAS and ICP-AES to increase sensitivity. However, hydrochloric acid is mostly used to acidify the sample solution in HG. Isobaric interferences due to chlorine-related species cause mass spectral problems when the same solution is used for the determination of these elements by ICP-MS. In this study, different oxidation states of As and Se were determined by coupling ion chromatography (IC) to an ICP-AES instrument. An HG technique was used to introduce test samples into the ICP. Nitric acid was employed to acidify the samples for HG. The concentrations of acid and base were kept as low as possible to reduce contamination. The formation of As and Se hydrides could be achieved without HCl, if the concentrations of acid and alkaline solutions were optimized. However, HCl was necessary for additional reduction of Se(VI) to Se(IV).  相似文献   

2.
In this study a flow injection (FI) system used in conjunction with hydride generation (HG), atomic absorption spectrometry (AAS) and microwave (MW) aided pre-reduction of selenite (Se(IV)) to selenate (Se(IV)) with HCl:HBr has been developed in order to differentiate both inorganic selenium species. As full control of the MW reduction step is possible, the experimental approach allows the use of milder acidic conditions (10% v/v of HCl and HBr) than those conventionally accomplished with hydrochloric acid alone (≥50% v/v). Experimental parameters were optimized by the univariate optimization method. In either case, the linear range was from 1.0 to 30 μg l−1. The detection limits based on 3σ of the blank signal were 0.25 μg l−1 for Se(IV) and 0.30 μg l−1 for Se(VI). The reproducibility, about 3% RSD and recoveries of different amounts of Se(VI) and Se(IV) added to water and orange juice samples (97–103%) were good. The main advantage of the proposed method is that the sequential determination of Se(IV) and Se(VI) is performed at a high sampling frequency (ca. 50 samples per h) in a closed system without Se losses, and with a minimum sample waste, operator attention, and sample manipulation.  相似文献   

3.
A sensitive and non chromatographic analytical procedure for the separation of inorganic selenium species in natural water has been performed. A combination of APDC coprecipitation and determination by an absolute thin layer Energy dispersive X-ray fluorescence spectrometry method was used. The influence of various analytical parameters such as element concentration, oxidation states and pH on the recoveries of Se (IV) was examined. The presence of organic matter and bicarbonate anions, typical components in Cuban groundwater samples, was also tested. Negligible matrix effects were observed. At pH 4 a 100% recovery was found for Se (IV). The coprecipitation recovery of the oxidized selenium species (Se (VI)) was null for the selected concentration range (5–100 μg L−1). When the Se (VI) was reduced by heating the solution with 4 mol L−1 HCl, quantitative recovery was also obtained. The determination of total selenium was conducted by the application of the oxidation–reduction process and the analytical procedure for Se (IV). Se (VI) content was calculated as the difference between total selenium and Se (IV). The detection limit was 0.13 μg L−1. The relative standard deviation was lower than 3.5% for 5 μg L−1 of Se (IV). The trueness of the method was verified by using standardized hydride generation-atomic absorption spectrometry technique. The results obtained using the EDXRF technique were in good agreement with the ones determined by HG-AAS. The proposed method was applied to the determination of Se (IV) in surface water and groundwater samples.  相似文献   

4.
An on-line flow injection system has been developed for the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters by hydride generation atomic absorption spectrometry with microwave-aided heating prereduction of Se(VI) to Se(IV). The samples and the prereductant solutions (4 mol l−1 HCl for Se(IV) and 12 mol l−1 HCl for Se(VI)) which circulated in a closed-flow circuit were injected by means of a time-based injector. This mixture was displaced by a carrier solution of 1% v/v of hydrochloric acid through a PTFE coil located inside the focused microwave oven and mixed downstream with a borohydride solution to generate the hydride. The linear ranges were 0–120 and 0–100 μg l−1 of Se(IV) and Se(VI), respectively. The detection limits were 1.0 μg l−1 for Se(IV) and 1.5 μg l−1 for Se(VI). The precision (about 2.0–2.5% RSD) and recoveries (96–98% for Se(IV) and 94–98% for Se(VI)) were good. Total selenium values were also obtained by electrothermal atomic absorption spectrometry which agreed with the content of both selenium species. The sample throughput was about 50 measurements per hour. The main advantage of the method is that the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters is performed in a closed system with a minimum sample manipulation, exposure to the environment, minimum sample waste and operator attention.  相似文献   

5.
Absorption spectroscopic properties for various Pu oxidation states in nitric and hydrochloric acid solutions were investigated with UV-Visible spectrophotometry. As a result, it was confirmed that the intensities of the major absorption peaks had a tendency to decrease for Pu(III), Pu(IV) and Pu(VI) in HCl and HNO3 media, and the major peak positions were shifted to longer or shorter wavelengths depending on the complexforming abilities of Pu(III), Pu(IV) and Pu(VI) with the chloride or nitrate ion with increasing acid concentrations. The values of the wavelength and the molar absorptivity for the principal peaks of Pu(III), Pu(IV) and Pu(VI) in NHO3 and HCl solutions were similar to those reported in other works. The values of the molar absorptivity for the principal peaks of Pu(III), Pu(IV) and Pu(VI) in the HNO3 solution were a little higher than those in the HCl solution.  相似文献   

6.
Hydride generation (HG) coupled with AAS, ICP–AES, and AFS techniques for the speciation analysis of As, Sb, Se, and Te in environmental water samples is reviewed. Careful control of experimental conditions, offline/online sample pretreatment methods employing batch, continuous and flow-injection techniques, and cryogenic trapping of hydrides enable the determination of various species of hydride-forming elements without the use of chromatographic separation. Other non-chromatographic approaches include solvent extraction, ion exchange, and selective retention by microorganisms. Sample pretreatment, pH dependency of HG, and control of NaBH4/HCl concentration facilitate the determination of As(III), As(V), monomethylarsonate (MMA), and dimethylarsinate (DMA) species. Inorganic species of arsenic are dominant in terrestrial waters, whereas inorganic and methylated species are reported in seawater. Selenium and tellurium speciation analysis is based on the hydrides generation only from the tetravalent state. Se(IV) and Se(VI) are the inorganic selenium species mostly reported in environmental samples, whereas speciation of tellurium is rarely reported. Antimony speciation analysis is based on the slow kinetics of hydride formation from the pentavalent state and is mainly reported in seawater samples.  相似文献   

7.
The paper presents a procedure for the multi-element inorganic speciation of As(III, V), Se(IV, VI) and Sb(III, V) in natural water with GF-AAS using solid phase extraction technology. Total As(III, V), Se(IV, VI) and Sb(III, V) were determined according to the following procedure: titanium dioxide (TiO2) was used to adsorb inorganic species of As, Se and Sb in sample solution; after filtration, the solid phase was prepared to be slurry for determination. For As(III), Se(IV) and Sb(III), their inorganic species were coprecipitated with Pb-PDC, dissolved in dilute nitric acid, and then determined. The concentrations of As(V), Se(VI) and Sb(V) can be calculated by the difference of the concentrations obtained by the above determinations. For the determination of As(III), Se(IV) and Sb(III), palladium was chosen as a modifier and pyrolysis temperature was 800 °C. Optimum conditions for the coprecipitation were listed for 100 ml of sample solution: pH 3.0, 15 min of stirring time, 40.0 μg l−1 Pb(NO3)2 and 150.0 μg l−1 APDC. The proposed method was applied to the determination of trace amounts of As(III, V), Se(IV, VI) and Sb(III, V) in river water and seawater.  相似文献   

8.
The solution conditions and other parameters affecting the ammonium pyrrolidine-dithiocarbamate—methyl isobutyl ketone extraction system for graphite-furnace atomic absorption spectrometric determination of As(III), As(V), Sb(III), Sb(V), Se(IV) and Se(VI) were studied in detail. The solution conditions for the single or simultaneous extraction of As(III), Sb(III) and Se(IV) were not critical. Arsenic(V) and Se(VI) were not extracted over the entire range of pH and acidity studied. Antimony(V) was extracted only in the acidity range 0.3—1.0 M HCl. Simultaneous extraction of total arsenic and total antimony was possible after reduction of As(V) with thiosulphate. Interference studies are also reported.  相似文献   

9.
Yu MQ  Liu GQ  Jin Q 《Talanta》1983,30(4):265-270
A novel procedure for determination of trace As(III) and As(V), Sb(III) and Sb(V), Se(IV) and Se(VI), Te(IV) and Te(VI) in water by atomic-absorption spectrophotometry after separation and enrichment with "thiol cotton" and hydride generation has been established. The sorption behaviour of various oxidation states of arsenic, antimony, selenium and tellurium, and the conditions of quantitative sorption and desorption of these species were studied. The procedures for reducing species from higher oxidation states were optimized. Interferences from other species and their elimination were investigated. The selectivity of the procedure for the determination of species in higher and lower oxidation states was examined. The procedure has been successfully used to determine arsenic, antimony, selenium and tellurium in water, in the range from pg ml to ng ml . The recoveries for added spikes were in the range 90-110%, with coefficients of variation in the range 3-8%  相似文献   

10.
Metal content in samples of shell of mussel Mytilus galoprovincialis was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). The efficiency of conversion of crude samples into solution by acid digestion in an open plate and in a microwave oven was examined by use of certified reference material of marine sediment and laboratory made standards of calcite and aragonite. Influence of high Ca content matrix on emission intensities of Al, Ba, Cd, Cu, Fe, Mg, Mn, Na, Ni, Pb, Sr and Zn was observed as depression of emission signal for most of the measuring elements, ranging from 0.8% to 8%. Greater values were noted at Ba and Ni emission lines. Enhancement of signals was observed for Na and Mg lines. The determination of As, Sb, Se and Sn was performed by HG/ICP-AES. The greater abundance of Sn was found in samples collected near the Al-processing industry centre. No detectable concentrations of As, Sb, and Se were found in shell samples. Results of ICP-AES metal analysis showed that samples collected near harbours, city waste or sewage outlets, and chemical industry centres indicate the certain level of contamination. It is shown that shell analysis provides useful data in determination of marine environment status.  相似文献   

11.
As a result of microbiological activity it is possible to find dimethylselenium (DMSe) and dimethyldiselenium (DMDSe) in a wide type of environmental samples, such as soils, sediments, sewage sludges and plants where methylation can take place.Selenium determination by hydride-generation (HG) techniques requires its presence as Se(IV). Consequently, inorganic speciation by hydride generation techniques is done by first determining Se(IV) and then, after reduction of Se (VI) to Se(IV), the total selenium. Therefore, the concentration of Se (VI) is evaluated as the difference between total inorganic selenium and Se(IV). In the present work it could be demonstrated that DMSe and DMDSe are forming other volatile species by reaction with sodium borohydride, applying the same reduction condition as for inorganic selenium. These species are subsequently detected by several atomic techniques (atomic absorption AAS, atomic fluorescence AFS and inductively coupled plasma-mass spectrometry ICP-MS). The error that their presence can cause in determination of inorganic selenium has been evaluated. The magnitude of this error depends on the specific analytical detector used.The coupling of pervaporation-atomic fluorescence is proposed for the identification of these species and pervaporation-gas chromatography-atomic fluorescence for their individual quantification.  相似文献   

12.
A method for the determination of As, Hg, Sb, Se and Sn in environmental and in geological reference materials, as acidified slurries, by flow injection (FI) coupled to a hydride generation system (HG) and detection by inductively coupled plasma mass spectrometry (ICP-MS) is proposed. The HG unit has a gas liquid separator and a drying unit for the generated vapor. The slurries were prepared by two procedures. Approximately 50 mg of the reference material, ground to a particle size ≤50 μm, was mixed with acid solutions in an ultrasonic bath. In Procedure A, the medium was a hydrochloric acid solution while in Procedure B, the medium was aqua regia plus a hydrochloric acid solution. The conditions for the slurry formation and the instrumental parameters were optimized. Harsh conditions were used in the slurry preparation in order to reduce the hydride forming analytes to their lower oxidation states, As (III), Se(IV), Sb(III) and Sn(II), before reacting with sodium tetrahydroborate. To test the accuracy, 10 certified reference materials were analyzed (four sediments, three coals, one coal fly ash and two sewage sludges), with the analyte concentrations mostly in the μg g−1 level. Good agreements with the certified values were obtained for Hg, Sb and Sn in the sediments using Procedure A and calibration against aqueous standard solutions. Using Procedure B, good results were obtained for Hg, Se and Sn in the sediment samples, for Se in the coal and coal fly ash samples and for Hg in the sewage sludge samples, also using external calibration with aqueous standard solutions. For As in sediments, coals and coal fly ash, Procedure B and the analyte addition calibration was required, indicating matrix effects. The relative standard deviations were lower than 5%, demonstrating a good precision for slurry analysis. The limits of quantification (10 times the standard deviation; n=10), in the samples, in ng g−1, were: 20 for As, 60 for Hg, 80 for Sb, 200 for Se and 90 for Sn. The method requires small amounts of reagents and reduces contamination and losses.  相似文献   

13.
In this study, thiourea (TU) was novelly developed as a reduction reagent for on-line pre-reduction of selenium(VI) before conventional hydride generation (HG) by KBH4/NaOH–HCl. After TU on-line pre-reduction, the HG efficiency of Se(VI) has been greatly improved and because even higher than that of the same amount of Se(IV) obtained in the conventional HG system. The possible pre-reduction mechanism is discussed. The detection limit (DL) of selenate reaches 10 pg mL 1 when using on-line TU pre-reduction followed by HG atomic fluorescence detection. When TU pre-reduction followed by HG is used as an interface between ion-pair high performance liquid chromatography and atomic fluorescence spectrometry, selenocystine, selenomethionine, selenite and selenate can be measured simultaneously and quantitatively. The DLs of these are 0.06, 0.08, 0.05 and 0.04 ng mL 1, respectively, and the relative standard deviations of 9 duplicate runs for all the 4 species are less than 5%. Furthermore, it was successfully applied to Se speciation analysis of cultured garlic samples, and validated by determination of total selenium and selenium species in certified reference material NIST 1946.  相似文献   

14.
Afkhami A  Madrakian T 《Talanta》2002,58(2):311-317
A simple, accurate, sensitive and selective method is described for rapid determination of ultra-trace quantities of selenium. Selenium (IV) was collected on activated carbon after reduction to elemental Se by l-ascorbic acid. The collected selenium was then determined based on its accelerating effect on the oxidation reaction of methyl orange with bromate in acidic media. Total amount of Se(IV) and Se(VI) were collected on AC after their reduction by hydrazine. Se(IV), Se(VI) and total selenium could be determined by the method. Selenium in the range 10-10 000 ng could be determined by the method. The method was used to the determination of Se(IV), Se(VI) and total selenium in natural water with satisfactory results.  相似文献   

15.
A novel method for the separation and preconcentration of Se(IV)/ Se(VI) with algae and determination by graphite furnace atomic absorption spectrometry (GFAAS) has been developed. The Se(VI) is extracted with algae from the solution containing Se(IV)/Se(VI) at pH 5.0, and the remaining Se(IV) is then preconcentrated pH 1.0. The detection limits (3σ, n = 11) of 0.16 μg L–1 for Se(IV) and 0.14 μg L–1 for Se(VI) are obtained using 40 mL of solution. At the 2.0 μg L–1 level the relative standard deviation is 2.6% for Se(IV) and 2.3% for Se(VI). The method has been applied to the determination of Se(IV)/Se(VI) in sediment and water samples. Analytical recoveries of Se(IV) and Se(VI) added to samples are ¶97 ± 5% and 102 ± 6% (95% confidence), respectively.  相似文献   

16.
The reliability of two solvent extraction techniques for the determination of Pu oxidation states in solution was tested with low-ionic-strength solutions and with high-Na and high-Mg brines that contained Pu concentrations sufficient for spectrophotometric analysis. One procedure only differentiates between reduced Pu [Pu(III) and Pu(IV)] and oxidized Pu [Pu(V) and Pu(VI)], whereas the second procedure was designed to differentiate between Pu(IV), Pu(V), and Pu(VI) in solution. Both procedures successfully differentiated between oxidized and reduced Pu in both dilute solutions and brines when tested with samples that contained only the Pu(IV), Pu(V), or Pu(VI) oxidation states. However, when the second solvent extraction procedure, which differentiates between Pu(V) and Pu(VI), was employed for solutions that did not contain a strong oxidant to maintain the Pu(VI) oxidation state, significant quantities of Pu(VI) were reduced to Pu(V) during extraction, indicating that accurate quantification of Pu(V) and Pu(VI) is not possible with this procedure.Work supported by the U. S. Department of Energy under Contract DE-ACO6-76RLO 1830.  相似文献   

17.
《中国化学快报》2022,33(7):3444-3450
A simple and convenient method has been developed for the pre-concentration and separation of inorganic selenium species from environmental water samples using anion exchange chromatographic column combined with high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) measurement. 75Se(IV) and 75Se(VI) were prepared and used as tracers during the experiments. The volatility of selenium during solution evaporation was investigated to establish a reliable water samples pretreatment procedure. The parameters which affect the uptake of Se(IV) and Se(VI) on Dowex1 × 8 resin was optimized and the procedure for Se(IV) and Se(VI) separation was proposed. Both Se(IV) and Se(VI) are retained on the column in natural or alkaline solution with high distribution coefficient. The successive gradient elution of pre-concentrated species of selenium with HNO3 solution allows to differentiate between them. Se(IV) and Se(VI) finally were eluted with 0.05 mol/L HNO3 and 5.0 mol/L HNO3, respectively. The proposed method has been successfully verified using the certified reference materials (CRMs) of real water samples, and spiked recoveries for real samples were 98%-104% with 5% relative standard deviations (RSDs). The developed procedure is proved to be reliable and can be used for the rapid determination of selenium species in environmental water samples.  相似文献   

18.
 Parameters for the reduction of Se(VI) to Se(IV) in HCl medium by heating in a microwave oven have been optimized. The reduction resulted to be quantitative applying 100% power, corresponding to 600 W heating for 2 min in 6 mol/L or for 3 min in 4 mol/L HCl. The behavior of selenomethionine and selenocystine under the optimized reduction conditions was studied in order to evaluate a possible interference of these selenium species in the determination of Se(VI). The final determination of Se(IV), and Se(VI) were done by hydride generation-atomic absorption spectrometry. The analytical merits of the method are reported. The method was applied to the selective determination of Se(IV), and Se(VI) in spiked river and lake water. Received: 6 December 1996/Revised: 1 April 1997/Accepted: 3 April 1997  相似文献   

19.
A novel method for the separation and preconcentration of Se(IV)/ Se(VI) with algae and determination by graphite furnace atomic absorption spectrometry (GFAAS) has been developed. The Se(VI) is extracted with algae from the solution containing Se(IV)/Se(VI) at pH 5.0, and the remaining Se(IV) is then preconcentrated pH 1.0. The detection limits (3σ, n = 11) of 0.16 μg L–1 for Se(IV) and 0.14 μg L–1 for Se(VI) are obtained using 40 mL of solution. At the 2.0 μg L–1 level the relative standard deviation is 2.6% for Se(IV) and 2.3% for Se(VI). The method has been applied to the determination of Se(IV)/Se(VI) in sediment and water samples. Analytical recoveries of Se(IV) and Se(VI) added to samples are ?97 ± 5% and 102 ± 6% (95% confidence), respectively. Received: 10 February 1999 / Revised: 21 June 1999 / /Accepted: 22 June 1999  相似文献   

20.
A simple procedure is described for reducing the chemical interference of heavy metal ions with the hydride—atomic absorption spectroscopic method for the determination of selenium. This is achieved through the formation of stable chlorocomplexes of these ions in 7.5 M HCl. Up to 30 μg Cu(II) ml-1, 500 μg Ni(II) ml-1, and 500 μg Fe(III) ml-1 do not interfere. Recoveries of selenium from standard reference samples, fortified with known interfering concentrations of heavy metals, range between 92 and 101%. The reducing property of hydrochloric acid is used to differentiate between Se(IV) and Se(VI) species.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号