首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 395 毫秒
1.
Possibilities to increase the sensitivity of stripping analysis by optimising the hydrodynamic conditions of the solution during the deposition and rest period are evaluated. Rotation rates as high as 13 000 rpm can be applied during the deposition step at a mercury film rotating disc electrode for Zn, Cd, Pb, In and Tl determinations when 10-20 mg/l of Hg(2+) for the renewal of the mercury film is added. Because of the extreme sensitivity on the properties of the mercury film in the case of Ga only 4000-5000 rpm are recommended. The highest stirring efficiencies using a magnetic stirrer are equivalent to 2500-3000 rpm when a rotating disc electrode is used. The effect of the duration of the rest period is not significant for square wave stripping voltammetry, however, analytical signals can be increased 10 and more times when potentiometric stripping analysis is applied.  相似文献   

2.
An adsorptive stripping voltammetric method for the determination of the pesticide dinoseb (2-sec.-butyl-4,6-dinitrophenol) at the mercury film electrode is described. The deposition of the mercury film on a glassy carbon disk electrode was optimized. The temperature, at which the mercury film was deposited, was demonstrated to have a strong influence on the stripping peaks, the first one being much more intense than the second. A systematic study of the variables affecting the stripping response was carried out by differential pulse voltammetry. The results obtained have been compared with those at the HMDE; a significant improvement in the sensitivity of the method developed with the MFE was observed. Using a 300 s accumulation time, the limits of determination and detection were 3.6 × 10–10 and 1.1 × 10–10 mol L–1, respectively. The effect of the presence of several herbicides on the dinoseb response was also tested. The method has been applied to the determination of the pesticide in spiked apple juice at two concentration levels: 12.0 and 1.2 g L–1 of juice.  相似文献   

3.
The equipment and procedure are described for the determination without preconcentration of several heavy metals based on d.c. anodic stripping voltammetry at a rotating ring—disc glassy carbon electrode with in situ mercury plating. During stripping of the metals deposited on the disc, the current from the reduction of the ions collected at the ring is measured. Some parameters (scan rate, thickness of the mercury film, electrode rotation and deposition time) influencing the ring collection peak current are examined experimentally. The results are compared with the theoretical considerations given by de Vries and van Dalen for anodic stripping voltammetry on a stationary mercury film electrode and by Bakanov et al. for a rotating mercury film electrode.  相似文献   

4.
An electrochemical method for the determination of trace levels of mercury based on a multi-walled carbon nanotubes (MWNT) film coated glassy carbon electrode (GCE) is described. In 0.1 mol L–1 HCl solution containing 0.02 mol L–1 KI, Hg2+ was firstly preconcentrated at the MWNT film and then reduced at –0.60 V. During the anodic potential sweep, reduced mercury was oxidized, and then a sensitive and well-defined stripping peak at about –0.20 V appeared. Under identical conditions, a MWNT film coated GCE greatly enhances the stripping peak current of mercury in contrast to a bare GCE. Low concentrations of I remarkably improve the determining sensitivity, since this increases the accumulation efficiency of Hg2+ at the MWNT film coated GCE. The stripping peak current is proportional to the concentration of Hg2+ over the range 8×10–10–5×10–7 mol L–1. The lowest detectable concentration of Hg2+ is 2×10–10 mol L–1 at 5 min accumulation. The relative standard deviation (RSD) at 1×10–8 mol L–1 Hg2+ was about 6% (n=10). By using this proposed method, Hg2+ in some water samples was determined, and the results were compared with those obtained by atomic absorption spectrometry (AAS). The two results are similar, suggesting that the MWNT-film coated GCE has great potential in practical analysis.  相似文献   

5.
Capabilities for heavy metal speciation of anodic stripping voltammetry (ASV) and constant-current stripping chronopotentiometry (SCP) in both mercury drop (HMDE) and mercury film rotating disk (MFE-RDE) electrodes are compared. For this purpose, the Cd(II)–glycine and Cd(II)–polymethacrylate (PMA) systems are used as models of simple labile and macromolecular labile complexes adsorbing onto the electrode, respectively. The results suggest that SCP could be a valuable alternative to the more widespread ASV in this kind of study. Concerning the electrode, the MFE-RDE is less user-friendly than the HMDE, but presents a better definition of both the hydrodynamic conditions during the deposition step and the stripping regime during the oxidation. An important interference in SCP is the dissolved oxygen, which can be minimised by combining relatively large oxidation currents and low stirring rates. Moreover, for Cd–PMA, double peaks have been observed in both ASV and SCP, which seems to be due to the lack of enough ligand excess to complex the metal ions released by the amalgam oxidation. Anyway, this problem can be minimised by optimising the rotation rate of the electrode and ensuring enough ligand excess.  相似文献   

6.
The effectiveness and accuracy of the correction for background current in subtractive anodic stripping voltammetry at rotating mercury film electrodes are discussed. The effects of different experimental parameters on the subtracted baseline are examined. Long deposition periods, at extreme potentials, result in large errors in the background correction. The incomplete background correction is attributed mainly to changes in the morphology of the working electrode. Different approaches for obtaining the subtractive stripping response are compared. Errors are reduced when subtractive differential pulse stripping is used at different convection rates, resulting in a detection limit of 2 × 10-9 M cadmium with 1-min deposition. Cadmium, lead, and zinc ions at nano molar concentrations were used as test ions.  相似文献   

7.
A rotating mercury-plated reticulated vitreous carbon (RVC) electrode is tested for square-wave anodic stripping voltammetry; RVC provides very large surface areas which are easily plated with mercury. Despite the ill-defined geometry of the electrode, the square-wave stripping peaks are very well defined; their behaviour conforms partly to known theory for square-wave stripping from mercury film electrodes. Fast analytical determinations of lead and cadmium in the μg l?1 range are facilitated by the high efficiency of the preconcentration step and the high sensitivity given by the stripping waveform.  相似文献   

8.
Screen-printed carbon electrodes were fabricated with amino acid functionality by using in situ co-deposition of mercury and cysteine. The three-electrode configuration (graphite carbon working electrode, carbon counter electrode and silver/silver chloride reference electrode) incorporating a cysteine-modified working electrode exhibited good sensitivity towards cadmium(II). Several experimental variables affecting the sensor stripping response were characterised and optimised. These include cysteine and mercury concentrations, deposition time, deposition potential and stripping current. Surface analysis was also conducted using scanning electron microscopy (SEM) in order to characterize the electrode surface during cadmium analysis. The stripping chronopotentiometric response for cadmium(II) was linear in the concentration range 0.4–800 g L–1 when a deposition time of 2 min was used. A detection limit of 0.4 g L–1 was obtained using 0.025 M Tris–HCl buffer containing 0.1 M KCl (pH 7.4) as the supporting electrolyte. The analytical utility of the cysteine-modified sensor was demonstrated by applying it to cadmium analysis in various wastewater and soil samples collected from a contaminated site and extracted using acetic acid. The results obtained using the developed electrodes agreed satisfactorily with the values achieved using atomic absorption spectrometry and inductively coupled plasma mass spectrometry analysis. These results demonstrate the feasibility of using this type of sensor for cadmium analysis.  相似文献   

9.
The effect of various instrumental parameters is investigated and optimized conditions established. The results are in accordance with the theory of differential pulse anodic stripping voltammetry. Both a hanging mercury drop electrode, and a rotating glassy carbon electrode mercury plated in situ were used. The best detection limit is obtained with the mercury film electrode, but the hanging mercury drop electrode is more reproducible. The differential pulse stripping technique is compared to linear sweep stripping, and increased sensitivity and better peak separation is demonstrated for the former technique, particularly when a hanging mercury drop electrode is used. However, the differential pulse technique will also improve the detection limit for a mercury film electrode, if the electrode has a non-ideal response with a corresponding high background current.  相似文献   

10.
A procedure was developed for determining 4.0 × 10–6 to 2.6 × 10–3 M enalapril in model solutions and blood serum by anodic stripping voltammetry at a mercury film electrode.__________Translated from Zhurnal Analiticheskoi Khimii, Vol. 60, No. 5, 2005, pp. 495–498.Original Russian Text Copyright © 2005 by Gusakova, Ivanovskaya.  相似文献   

11.
Anodic stripping voltammetry at a glassy carbon disc electrode covered by a thin mercury film was adapted for use in a flow-through cell. The resulting system is characterized by extreme simplicity of set-up and operation, high sensitivity and excellent precision and stability. Its performance was tested via the determination of hydrated or labile complex ions of heavy metal ions in sea water, using short (2–10 min) deposition periods. The dependence of the stripping peak charge on metal ion concentration, length of deposition period, solution flow rate and other variables was examined and the reliability of the results obtained were evaluated under conditions resembling continuous monitoring.  相似文献   

12.
A stripping chronopotentiometric method, using a rotating gold disk electrode for mercury measurements in sea water is described. Compared with a same method using a stationary gold film electrode, this method has a eight times higher sensitivity and a detection limit of 5 ng l−1 after 10 min deposition time. Moreover, the time needed for gold plating is eliminated. Compared with other electrochemical methods capable of measuring mercury at low concentrations, the present method is more simplified with no degassing step and no need to use a medium-exchange procedure before the stripping step. These characteristics render the method easily practicable on board oceanographic vessels for ‘in situ’ measurements.  相似文献   

13.
We developed a stripping chronopotentiometric method (constant current stripping analysis, CCSA) with a mercury film electrode for selenium quantification in seawater. A sensitivity and detection limit of 222 ms ng–1 l and 4 ng l–1 (50 pM), respectively, were accomplished for a 3-min electrolysis time. Compared to the other chronopotentiometric methods available for a single selenium measurement only in natural waters, our procedure exhibits a ten times better sensitivity. It, therefore, allows one to reach the current concentration thresholds found in coastal and oceanic waters (30–200 ng l–1). Moreover, a simple change in operating conditions enables one to also quantify Se(IV), a toxic dissolved species. With respect to the other electrochemical methods of current use, our procedure is beneficial because of its ease-of-use: it needs neither degassing step, nor catalyser.  相似文献   

14.
Gold, platinum and carbon fibres with 10-μm diameter were mounted in PVC tubes and used as flow sensors in computerized potentiometric and constant-current stripping analysis for mercury, after electroplating ofa gold film onto the fibre surfaces. Compared to gold and glassy carbon disc electrodes, the fibre electrodes gare increased sensitivity and stability and were considerably simpler to handle. The gold-coated carbon fibre electrode gave a higher background than the gold fibre electrode, in both the potentiometric and constant-current stripping modes. Mercury(II) could be determined in presence of a 105-fold (molar) amount of copper(II) by constant-current stripping in media with chloride concentrations below 0.05 M. The detection limit for mercury(II) after 10 min of electrolysis was 45 ng l?1 at the 3 σ level.  相似文献   

15.
Summary An amperometric enzyme sensor composed of a mercury film electrode and an enzyme-immobilized chitosan membrane is developed. This biosensor is based on both a mercury film electrode detecting the consumption of dissolved dioxygen following enzymatic reaction, and a chitosan membrane. The latter provides an excellent permselectivity and excludes electroactive interferents. The detection range of this biosensor was 1.0×10–5–3.0×10–4 mol/l and the relative standard deviation, R.S.D. at 5.0×10–5 mol/l was 1.4% (n=3). This biosensor was applied to the direct determination of L-lactate in human serum without pretreatment.  相似文献   

16.
The combined effects of pH, thiocyanate ion and deposition potential in the characteristics of thin mercury film electrodes plated on glassy carbon surfaces are evaluated. Charges of deposited mercury are used as an experimental parameter for the estimation of the effectiveness of the mercury deposition procedure. The sensitivity of the anodic stripping voltammetry (ASV) method for the determination of lead at in situ and at ex situ formed thin mercury films are also examined. It was concluded that, in acidic solutions (pH 2.5-5.7) and fairly negative deposition potentials, e.g. −1.3 to −1.5 V, thiocyanate ion promotes the formation of the mercury film, in respect both to the amount of deposited mercury and to the mercury deposition rate. Also, the mercury coatings produced in thiocyanate solutions are more homogeneous, as depicted by microscopic examinations. In the presence of thiocyanate there is no obvious advantage of using high concentrations of mercury and/or high deposition times for the in situ and ex situ preparation of the mercury film electrodes. The optimised thin mercury film electrode ex situ prepared in a 5.0 mM thiocyanate solution of pH 3.4 was successfully applied to the ASV determination of lead and copper in acidified seawater (pH 2). The limit of detection (3σ) was 6×10−11 M for lead and 2×10−10 M for copper for a deposition time of 5 min. Relative standard deviations (R.S.D.s) of <1.2% were obtained for determinations at the nanomolar of concentration level.  相似文献   

17.
The use of the rotating glassy carbon electrode mercury plated in situ for anodic stripping voltammetry has been investigated. The choice of electrode material is discussed. The effect of instrumental parameters on the stripping response for copper, lead and cadmium in sea water is studied, the results being in accordance with the theory of thin film electrodes. The variation in the observed sensitivity for the three metals in sea water is discussed in terms of complex-forming ligands. Lastly the performance of the film electrode is compared to that of the hanging mercury drop electrode.  相似文献   

18.
Summary The interferences caused by inorganic ions, organic anions and Triton X-100 in the determination of lead by flow injection potentiometric and voltammetric stripping analysis at a mercury film electrode were investigated. The experiments were performed in the concentration range of 1–10 mg/l Pb2+. For both methods linear calibration plots were obtained in the presence of an excess of nitrate, chloride, perchlorate and sulphate. Iodide strongly interferes due to mercury complexation.Metal ion interference caused by formation of irreversible amalgams (as in the case of codeposition of Ni, Co, Fe and Cr) is avoided by proper choice of deposition potential. No effect of water soluble reduced species, i.e. Fe(II) and Cr(II), on the stripping signals was observed. The presence of acetate, citrate and tartrate does not limit the determination of lead by potentiometric stripping analysis (PSA) but has a marked effect on anodic stripping voltammetric (ASV) signals. No influence of Triton X-100 on the determination of lead by PSA was found. In ASV 10–3% Triton X-100 diminished the peak current by 15%.

Herrn Prof. Dr. Rolf Neeb aus Anlaß seines 60. Geburtstags gewidmet  相似文献   

19.
The analytical utility of microelectrodes for stripping voltammetry is discussed from several points of view. The application of microelectrodes for microanalysis is demonstrated using a novel capillary flow injection system. Heavy metals at g l–1 concentrations have been determined in l-samples. The influence of electrode size and convection during the deposition period of anodic stripping voltammetry on the reproducibility of trace metal determination was studied for various types of electrodes. In the case of mercury film microelectrodes, the precision can be improved if the accumulation of the analyte is performed under quiescent conditions. Practical examples of stripping voltammetry with microelectrodes such as copper determination in whisky and trace metal measurements in drinking water are given.  相似文献   

20.
The optimum conditions were established for the determination of the genotoxic substance 1-(4-bromophenyl)-3,3-dimethyltriazene by differential-pulse voltammetry at a hanging mercury drop electrode in the concentration range 1 × 10–4 to 1 × 10–7 mol dm–3. The sensitivity of the determination can be improved through adsorptive accumulation of the investigated substance on the surface of the hanging mercury drop electrode: differential pulse adsorptive stripping voltammetry can be used in the concentration range 1 × 10–7 to 2 × 10–10 mol dm–3. The relative standard deviation (for ten determinations at 2 × 10–10 mol dm–3) was 7.5%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号