首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Gold nanoparticles were in-situ decorated on top of a polyaniline film (GNPs–PANI) via the direct electroreduction of the adsorbed AuCl 4 - ions on a glassy carbon electrode that previously was coated with PANI by electropolymerization. The GNPs–PANI composite and the performance of the resultant sensors were investigated in some detail. The sensor was applied to the oxidation of dopamine (DA) with improved catalytic activity. Its catalytic current showed wide linear response toward dopamine ranging from 3 to 115 μM, with a low detection limit of 0.8 μM (S/N=3). In addition, the sensor exhibits easy-operation, fast response to dopamine, as well as excellent reproducibility and stability.
Gold nanoparticles decorated polyaniline (GNPs-PANI) was prepared via electrosynthesis. The GNPs-PANI composite showed good catalytic activity toward the oxidation of dopamine.  相似文献   

2.
We have prepared a fiber for solid-phase microextraction of organochlorine pesticides. A graphene-polyaniline composite was electrochemically deposited on a platinum fiber by exploiting the unique properties of polyaniline and graphene. The modified fiber displays thermal stability up to 320 °C and can be used more than 70 times. It possesses high extraction efficiency due to the high specific surface of graphene. The Pt fiber was used for the extraction and subsequent GC determination of the pesticides heptachlor, aldrin, endrin and p,p’-DDT in aqueous samples. The effects of extraction time, extraction temperature, stirring rate, salinity and headspace volume were optimized. Calibration plots are linear (with an R2 of 0.990) in the 0.2 to 250 μg L–1 concentration range, and the limits of detection are below 11 ng L–1 (at an S/N of 3). The relative standard deviations for three replicate measurements with a single fiber were <11.0 %. The recovery of the pesticides from spiked seawater samples ranged from 81 % to 112 %.
Figure
The graphene–polyaniline (G/PANI) nanocomposite was prepared by simultaneous electropolymerization of G–aniline and used as a new coating for SPME of organochlorine pesticides as model compounds. The large delocalized π-electron system of G and high extraction capability of PANI caused to produce an efficient and sensitive sorbent for SPME  相似文献   

3.
It is well accepted that the morphology of the nanomaterials has great effect on the properties and hence their applications. Therefore, morphology of materials has become a focus of research in the scientific world. The present study shows that interfacial polymerization and subsequent self-assembly provides a control over the morphology, nanorod/nanosheet, of polyaniline (PANI) films synthesized by liquid–liquid interface reaction technique and solid–liquid interface reaction technique. The synthesized PANI films and its particulate structure are characterized by using various spectroscopic techniques such as UV–visible, ATR-IR, Raman and XPS. The study confirmed the formation, the structure, the size and shape of particles and morphology of PANI by using analytical techniques namely, SAED, SEM and TEM. An important observation is that doping with HCl significantly improves the nanorod formation at the interface. The doped PANI electrode exhibits a higher area with rectangular shape in CV cycle and better cycle stability when compared with the performance of undoped PANI films. We believe that the results of these studies can give valuable leads to manoeuvre formation of PANI films with desired morphology for various applications.
Figure
Time and temperature-dependent morphology of PANI layer leading to the formation of one/two-dimensional structures namely, PANI rods/sheets, is achieved by monitoring of self-assembly of nano particulate film formed at liquid–liquid/solid–liquid interfaces  相似文献   

4.
We report on a non-enzymatic amperometric sensor for hydrogen peroxide (H2O2). It was fabricated by electrodeposition of multi-wall carbon nanotubes and polyaniline along with platinum nanoparticles on the surface of a glassy carbon electrode. The modification was probed by scanning electron microscopy and cyclic voltammetry. The resulting sensor exhibits a high sensitivity (748.4?μA·mM?1·cm?2), a wide linear range (7.0?μM–2.5?mM), a low detection limit (2.0?μM) (S/N?=?3), a short response time (>5?s), and long-term stability, and is not interfered by common species. It was successfully applied to determine H2O2 in disinfectants.
Figure
SEM images of the obtained Pt/MWCNTs-PANI composite films with large surface-to-volume ratio and biocompatibility  相似文献   

5.
We report on an inorganic–organic hybrid nanocomposite that represents a novel kind of fiber coating for solid-phase microextraction (SPME) of polycyclic aromatic hydrocarbons (PAHs). The material is composed of ZnO nanoparticles, polythiophene and hexagonally ordered silica, and displays good extraction capability due to its nanostructure. The nanocomposite was synthesized by an in-situ polymerization technique, and the ZnO nanoparticles were anchored to the pores in the walls. The ZnO/polythiophene/hexagonally ordered silica (ZnO/PT/SBA-15) nanocomposite was then deposited on a stainless steel wire to obtain the fiber for SPME of PAHs. Optimum conditions include an extraction temperature of 85 °C (for 30 min only), a desorption temperature of 260 °C (for 2 min), and a salt concentration (NaCl) of 20 % (w/v). The detection limits are between 8.2 and 20 pg mL?1, and the linear responses extend from 0.1 to 10 ng mL?1. The repeatability for one fiber (for n?=?5), expressed as relative standard deviation, is between 4.3 and 9.1 %. The method offers the advantage of being simple to use, rapid, and low-cost (in terms of equipment). The thermal stability of the fiber and high relative recovery (compared to conventional methods) represent additional attractive features.
Figure
We report on an inorganic–organic hybrid nanocomposite that represents a novel kind of fiber coating with thermal stability and high relative recovery for solid-phase microextraction (SPME) of polycyclic aromatic hydrocarbons (PAHs). The method is simple to use, rapid and low-cost.  相似文献   

6.
Zhao  Fangyuan  Wang  Fei  Zhao  Weining  Zhou  Jing  Liu  Yang  Zou  Lina  Ye  Baoxian 《Mikrochimica acta》2011,173(3-4):383-389
A facile, one-step and template-free method has been developed for the electrodeposition of well-dispersed platinum nanoparticles (Pt-NPs) on a glassy carbon electrode. The effects of various inorganic anions and overpotential on the morphologies and dimensions of the final products were investigated. The resulting Pt-NPs show high electrocatalytic activity towards methanol oxidation and are less easily poisoned by carbon monoxide.
Figure
In this study, we have developed a simple, environmentally benign, controllable, and template-free method for the electrodeposition of monodispersed Pt NPs on a glassy carbon electrode. The resulting Pt NPs display high catalytic activity towards methanol oxidation, and are less easily poisoned by carbon monoxide.  相似文献   

7.
We are reviewing the state of electrochemical sensing of H2O2 based on the use of metal nanoparticles. The article is divided into subsections on sensors based on nanoparticles made from Ag, Pt, Pd, Cu, bimetallic nanoparticles and other metals. Some sensors display high sensitivity, fast response, and good stability. The review is subdivided into sections on sensors based on heme proteins and on nonenzymatic sensors. We also discussed the challenges of nanoscaled sensors and their future aspects.
Figure
Sensing mechanism of (A) mediator-based enzyme biosensor, (B) mediator-less enzyme biosensor and (C) nonenzymatic sensors with metal nanoparticles for the electrocatalytic reduction toward H2O2  相似文献   

8.
We introduce a rapid and sensitive approach to study the interactions of an affinity probe with the bacterial wall. Immunoglobulin was immobilized on platinum nanoparticles, and the resulting probe nanoparticles bind to bacterial walls as confirmed by transmission electron microscopy. A MALDI-MS assay was developed that can detect ~105 cfu mL?1 of S. marcescens and E. coli. This approach enables simple, rapid and straightforward detection of bacterial proteins, with high resolution and sensitivity, and without the requirement for tedious washing/separation steps.
Figure
Antobody IgG treated Pt NPs are successfully implemented to bind the cell surfaces of target bacteria. The current bio-analytical technique allows simple, rapid and straightforward identification of bacteria. The obtained results proved that IgG modified platinum nanoparticle strategy was also capable to enhance the protein peaks with high signal intensity and resolution.  相似文献   

9.
An electrochemical DNA biosensor was developed that is based on a gold electrode modified with a nanocomposite membrane made from an ionic liquid, ZnO nanoparticles and chitosan. A single-stranded DNA probe was immobilized on this electrode. Acridine orange was used as the hybridization probe for monitoring the hybridization of the target DNA. The biosensor was capable of detecting target DNA in the concentration range from 1.0?×?10?C14 to 1.8?×?10?C4?mol?L-1, with a detection limit of 1.0?×?10?C15?mol?L-1. The approach towards constructing a DNA biosensor allows studies on the hybridization even with crude DNA fragments and also to analyze sample obtained from real samples. The results show that the DNA biosensor has the potential for sensitive detection of a specific sequence of the Trichoderma harzianum gene and provides a quick, sensitive and convenient method for the study of microorganisms.
Figure
Suggested interaction mechanism of modified electrode (IL/ZnO/CHIT/AuE) between immobilization and hybridization  相似文献   

10.
We have developed a 3-dimensional (3-D) electrochemical sensor for highly sensitive detection of hydrogen peroxide (H2O2). Porous 3-D carbon nanofibers (CNFs), prepared by electrospinning, served as scaffold on a glassy carbon electrode. The 3-D CNFs were functionalized with platinum nanoparticles (Pt-NPs) by in-situ gas-phase decomposition of platinum salts at high temperature. The Pt-NPs act as an electrocatalyst for the decomposition of H2O2. TEM revealed that large amounts of Pt-NPs are deposited in the electrospun CNFs electrode even without using any stabilizer or reducing reagent. The sensor was investigated by cyclic voltammetry and amperometry and displays a good response to H2O2 with a linear range between 10 μM and 15 mM (R?=?0.9994), a low detection limit (3.4 μM at a signal-to-noise ratio of 3), and a response time of 3 s. The sensor shows excellent stability and selectivity.
Figure
We report the direct growth of the Pt NPs in the 3-D CNFs via electrospinning and sequent thermal treatment. We demonstrate the use of 3-D architecture novel Pt/CNFs electrode for nonenzymatic electrochemical sensing of H2O2. The sensor shows outstanding performance in terms of detection range, detection limit, response time, stability and selectivity.  相似文献   

11.
Platinum nanoparticles were electrodeposited onto a film of dihexadecyl hydrogen phosphate deposited on a glassy carbon electrode (GCE) and modified with dispersed acetylene black. Scanning electron microscopy and electrochemical impedance spectroscopy revealed that this nanocomposite has a uniform nanostructure and a large surface area that enables fast electron-transfer kinetics. The modified GCE showed high electrocatalytic activity for the oxidation of nitric oxide (NO). Under optimal conditions, the oxidation peak current of nitric oxide is linearly related to the concentration of NO in the concentration range between 0.18 and 120?μM, and the detection limit is as low as 50?nM (at an S/N of 3). The modified electrode was successfully applied to sensing of NO as released from rat liver.
Figure
Acetylene black (AB) was dispersed with dihexadecyl hydrogen phosphate (DHP) and modified on the surface of glassy carbon electrode (GCE) to fabricate AB/GCE, after activating in NaOH solution, the AB film became more porous and loosened, then through electrodepositing Pt nanoparticles (PtNPs) on the activated AB film, PtNP/AB/GCE was obtained, which was denoted as NO electrochemical sensor.  相似文献   

12.
We report on an ultrasensitive fluorescence immunoassay for human chorionic gonadotrophin antigen (hCG). It is based on the use of silica nanoparticles coated with a copolymer (prepared from a fluorene, a phenylenediamine, and divinylbenzene; PF@SiO2) that acts as a fluorescent label for the secondary monoclonal antibody to β-hCG antigen. In parallel, Fe3O4 nanoparticles were coated with polyaniline, and these magnetic particles (Fe3O4@PANI) served as a solid support for the primary monoclonal antibody to β-hCG antigen. The PF@SiO2 exhibited strong fluorescence and good dispersibility in water. A fluorescence sandwich immunoassay was developed that enables hCG concentrations to be determined in the 0.01–100 ng·mL?1 concentration range, with a detection limit of 3 pg·mL?1.
Figure
Fluorescence detection of prepared immune reagent nano-composites using the fluorescence cell  相似文献   

13.
A novel oligonucleotide delivery system that is based on oligonucleotide–nanoparticle conjugates has been described. Installed oligonucleotides were modified with the carbohydrate at the 3′ terminus, accordingly, constructed nanoparticles display clustered carbohydrates on their outer layer for the targeted delivery of oligonucleotides. The method for the construction of ligand-functionalized nanoparticle was simple and reproducible. The stability of the nanoparticles displaying clustered carbohydrates greatly increased in serum compared to nanoparticles without carbohydrates. In order to investigate the targetability of oligonucleotide–nanoparticle conjugates into primary hepatic parenchymal cells, freshly isolated rat hepatocytes were incubated with nanoparticles and the amount of internalized gold nanoparticles was evaluated by an inductively coupled plasma mass spectroscopy analysis. Nanoparticles displaying clustered carbohydrates internalized more efficiently than nanoparticles without carbohydrate modifications. In particular, the cellular uptakes of oligonucleotide-conjugated gold nanoparticle increased 1.7 ~2.0-fold by galactose modification. Competition assay revealed that clustered galactose enhanced the internalization of the nanoparticle into primary hepatic parenchymal cells by a receptor-mediated process.
Figure
A novel oligonucleotide delivery system that is based on oligonucleotide-nanoparticle conjugates has been described. Constructed nanoparticles display clustered carbohydrates on their outer layer. The stability of the nanoparticles displaying clustered carbohydrates increased in serum, and clustered galactose enhanced the internalization of the nanoparticle to hepatic parenchymal cells by a receptor-mediated process  相似文献   

14.
Colloidal crystal beads (CCBs) were fabricated by assembling monodisperse silica nanoparticles via a microfluidic device. The pore size of the CCBs was tuned by using different nanoparticles. The CCBs were then coated with cadmium telluride quantum dots and zinc(II) meso-tetraphenylporphyrin for the purpose of optical sensing. Ammonia causes the color of the sensor to change from green to red. The method has a dynamic range of 0–2500 ppm, good reversibility, and is not sensitive to humidity. The limit of detection is 7 ppm. The sensor has the advantage of a porous microcarrier structure and that pore sizes can be well controlled and thus can fulfill various demands in gas detection.
Figure
Figure SEM images of colloidal silica beads with different modified CCBs for colorimetric sensing of ammonia.  相似文献   

15.
In this study, we propose a novel micro-/nanofluidic device that can generate a chemical concentration gradient using a parallel nanochannel as gradient generator. This device is easy to fabricate, showing high reproducibility. Its main feature is the multiple-nanochannel-based gradient generator, which permits the diffusion of small molecules and tunably generates concentration gradients. The nanopattern for the nanochannels can be rapidly and easily fabricated by wrinkling a diamond-like carbon thin film which is deposited on a polydimethylsiloxane substrate; the generation of the concentration gradient can be adjusted by controlling the dimensions of the nanochannels. The developed gradient generator is embedded into a microfluidic device to study chemotaxis in the nematode Caenorhabditis elegans, which has a highly developed chemosensory system and can detect a wide variety of chemical molecules. This device shows good performance for rapid analysis of C. elegans chemotaxis under sodium chloride stimuli.
Figure
A parallel‐nanochannel‐based microfluidic device which can passively manipulate chemical concentration gradient by controlling the nanochannel geometry is employed for the analysis of Caenorhabditis elegans chemotaxis.  相似文献   

16.
We describe a new method for the separation and preconcentration of traces of Au(III) in environmental samples. Sorbents made from modified multiwalled carbon nanotubes and conducting polymers (PANI and PEDOT) were used for solid-phase extraction. The Au(III) ions are adsorbed as a result of the interaction with the electron pairs of =N- and -S- groups. Effects of pH value, flow rate and volume of sample, type, volume and concentration of eluent, and the adsorption capacity were investigated. The maximum adsorption capacity of MWCNTs/PANI and MWCNTs/PEDOT are 159 and 176?mg?g?1, and the detection limits of this method are below 0.3 and 0.5?ng?mL?1, respectively. The procedure was successfully applied to the determination of traces of Au(III) in a reference material and in environmental samples.
Figure
The multiwalled carbon nanotubes/conducting polymers (PANI and PEDOT) were used for solid-phase extraction of Au(III) ions. The Au(III) adsorbed on macromolecules chains; resulting from sharing an electron pair of = N?C and ?CS?C groups of conducting polymers with gold ions. The final results demonstrate that nanocomposites are convenient for preconcentration and determination of gold from environmental samples.  相似文献   

17.
Block copolymers based on poly(ethylene oxide) (PEO) and poly(ethylene imine) (PEI) are efficient catalysts/templates for the formation of uniform silica nanoparticles. Addition of tetraethylorthosilicate to a solution of PEO–PEI or PEI–PEO–PEI block copolymers results in the formation of silica particles with a diameter of ca. 30 nm and narrow size distribution. The particles precipitated with the diblock copolymers can be redispersed in water after isolation as individual nanoparticles. Evidently, block copolymers based on PEO and PEI serve as excellent templates for the biomimetic and “soft” synthesis of silica nanoparticles.
Figure
TOC graphic  相似文献   

18.
A highly sensitive electrochemical sensor for determination of L-cysteine (CySH) is presented. It is based on vertically aligned multiwalled carbon nanotubes modified with Pt nanoparticles by magnetron sputtering deposition. The morphology of the nanocomposite was characterized by scanning electron microscopy, transmission electron microscopy and energy-dispersive. The electrochemistry of CySH was investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The mechanism for the electrochemical reaction of CySH at the modified electrode at different pH values is discussed. The electrode exhibits a higher electrocatalytic activity towards the oxidation of CySH than comparable other electrodes. It displays a linear dependence (R 2?=?0.9980) on the concentration of CySH in the range between 1 and 500 μM and at an applied potential of +0.45 V, a remarkably low detection limit of 0.5 μM (S/N?=?3), and an outstandingly high sensitivity of 1.42?×?103 μA?mM?1?cm?2, which is the highest value ever reported. The electrode also is highly inert towards other amino acids, creatinine and urea. The sensor was applied to the determination of CySH in urine with satisfactory recovery, thus demonstrating its potential for practical applications.
Figure
Pt nanoparticles on carbon nanotubes by sputtering deposition show high performance for L-cysteine sensing  相似文献   

19.
We describe the preparation and sensing capabilities of a bimetallic electrode consisting of copper atoms deposited on gold nanoparticles (GNPs). The electrode was obtained by first constructing a GNP template on the surface of a glassy carbon electrode by exploiting the hydrogen-bonding interactions between pyridine groups on the surface of the GNPs and the carboxy groups of poly(acrylic acid). GNPs (60?nm in diameter) were homogeneously and densely deposited in the template (as revealed by scanning electron microscopy). The electro-deposition of copper ad-atoms on GNPs occurred at an underpotential and was proven by electrochemical techniques. The presence of GNPs in the template accelerated the deposition at low potential due to its beneficial effect on the rate of electron transfer. The new electrode was studied for its response to glucose. Highly stable and reproducible catalytic activity towards glucose oxidation is observed and attributed to the synergistic catalytic effect of the copper atoms on the surface of the GNPs. The detection limit is as low as 50?nM (at a signal-to-noise ratio of 3), and the response is between 200?nM and 10?mM of glucose.
Figure
Preparation of a bimetallic electrode consisting of copper atoms deposited on gold nanoparticles (GNPs)  相似文献   

20.
We have prepared calcined silver oxide-doped zinc oxide nanoparticles (NPs) by a hydrothermal method using reducing agents in alkaline medium. The doped NPs were characterized by UV/vis, FTIR, and X-ray photoelectron spectroscopy, and by X-ray powder diffraction and field-emission scanning electron microscopy. The NPs were deposited on microchips to result in a sensor that has a fast response to methanol in the liquid phase. Features include high sensitivity, low-sample volume, reliability, reproducibility, ease of integration, long-term stability, and enhanced electrochemical responses. The calibration plot is linear (r2?=?0.9981) over the 0.25 mmolL?1 to 0.25 molL?1 methanol concentration range. The sensitivity is ~7.917 μA cm?2 mmolL?2, and the detection limit is 71.0?±?0.5 μmolL?1 at a signal-to-noise-ratio of 3.
Figure
Fabrication of highly sensitive (~7.917 μA cm?2) and selective methanol chemical sensor based on hydrothermally prepared silver oxide doped zinc oxide nanoparticles deposited tiny microchips with a detection limit as low as 71.0 μM (at an S/N of 3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏