首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report on a method for the extraction of the lanthanide ions La(III), Sm(III), Nd(III) and Pr(III) using a carbon-ferrite magnetic nanocomposite as a new adsorbent, and their determination via flow injection ICP-OES. The lanthanide ions were converted into their complexes with 4-(2-pyridylazo)resorcinol, and these were adsorbed onto the nanocomposite. Fractional factorial design and central composite design were applied to optimize the extraction efficiencies to result in preconcentration factors in the range of 141–246. Linear calibration plots were obtained, the limits of detection (at S/N?=?3) are between 0.5 and 10 μg?L?1, and the intra-day precisions (n?=?3) range from 3.1 to 12.8 %. The method was successfully applied to a certified reference material.
Figure
Superparamagnetic activated carbon based nanocomposite was synthesized and applied for extraction and determination of some rare earth elements in water samples  相似文献   

2.
The use of direct current arc atomic emission spectrometry (DC-arc-AES) with a CCD spectrometer for the direct determination of the trace impurities Al, Ca, Cr, Cu, Fe, Mg, Mn, Na, Ni, Si, Ti, and Zr in three well characterized boron carbide powders is described. The detection limits obtained by the procedure were found to be between 0.2 (Mg) and 25 (Na) ??g?g?1 for the above elements. Three boron carbide powder samples with trace element concentrations between 0.9 (Cu) and 934 (Si) ??g?g?1 for Al, Ca, Cr, Cu, Fe, Mg, Mn, Na, Ni, Si, Ti, and Zr ?? including the standard reference material ERM?-ED102 ?? were analyzed by DC-arc-AES. The relative standard deviations for 9 measurements when using 5.0?±?0.3?mg of the respective samples were found to vary from 6.2 to 27% for Al and Cu, respectively. The trace elements Al, Ca, Cr, Cu, Fe, Mn, Ni, Si, Ti and Zr could be determined in the standard reference material and their concentrations determined by DC-arc AES were found to be between 89 and 116% of the accepted values. Fe and Ti were determined by DC-arc AES in the three boron carbide samples as well as in Al2O3, BN, SiC, coal fly ash, graphite and obsidian rock. The correlation coefficients of the plots of the net intensities versus the accepted values over the concentration ranges from 18 to 1750 and from 6 to 8000???g?g?1 are 0.999 and 0.990 for Fe and Ti, respectively.
Figure
Coupling of DC arc to a CCD spectrometer  相似文献   

3.
Green biosynthesis of nanoparticles and their applications in sensor field is of great interest to the researchers. We report herein a simple green approach for the synthesis of silver nanoparticles (Ag-NPs) using Acacia nilotica Willd twig bark and its application for the detection of 4-nitro phenol (4-NP). The synthesized Ag-NPs were characterized by Transmission electron microscopy, X-ray diffraction and elemental analysis. The size of synthesized Ag-NPs was in the range of 10–50 nm. The Ag-NPs modified electrode shows a high sensitivity and selectivity towards the sensing of 4-NP. The fabricated modified electrode shows a low detection limit of 15 nM on the wider linear response range from 100 nM to 350 μM with the sensitivity of 2.58?±?0.05 μAμM?1 cm?2. In addition, the fabricated sensor shows good repeatability and reproducibility.
Figure
The schematic representation of the fabrication of Ag-NPs and application of 4-nitrophenol sensing  相似文献   

4.
We have investigated the use of a Gaussian beam laser for MALDI Imaging Mass Spectrometry to provide a precisely defined laser spot of 5 μm diameter on target using a commercial MALDI TOF instrument originally designed to produce a 20 μm diameter laser beam spot at its smallest setting. A Gaussian beam laser was installed in the instrument in combination with an aspheric focusing lens. This ion source produced sharp ion images at 5 μm spatial resolution with signals of high intensity as shown for images from thin tissue sections of mouse brain.
Figure
?  相似文献   

5.
Particles were ablated from laser desorption and inlet ionization matrix thin films with a UV laser in reflection and transmission geometries. Particle size distributions were measured with a combined scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) system that measured particles in the size range from 10 nm to 20 μm. The matrixes investigated were 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CHCA), sinapic acid (SA), 2,5-dihydroxy-acetophenone (DHAP), and 2-nitrophloroglucinol (NPG). Nanoparticles with average diameters between 20 and 120 nm were observed in both transmission and reflection geometry. The particle mass distribution was significantly different in reflection and transmission geometry. In reflection geometry, approximately equal mass was distributed between particles in the 20 to 450 nm range of diameters and particles in the 450 nm to 1.5 μm diameter range. In transmission mode, the particle mass distribution was dominated by large particles in the 2 to 20 μm diameter range. Ablation of inlet ionization matrices DHAP and NPG produced particles that were 3 to 4 times smaller compared with the other matrices. The results are consistent with ion formation by nanoparticle melting and breakup or melting and breakup of the large particles through contact with heated inlet surfaces.
?  相似文献   

6.
Platinum nanoparticles (Pt-NPs) with sizes in the range from 10 to 30 nm were synthesized using protein-directed one-pot reduction. The model globular protein bovine serum albumin (BSA) was exploited as the template, and the resulting BSA/Pt-NPs were studied by transmission electron microscopy, energy dispersive X-ray spectroscopy, and resonance Rayleigh scattering spectroscopy. The modified nanoparticles display a peroxidase-like activity that was exploited in a rapid method for the colorimetric determination of hydrogen peroxide which can be detected in the 50 μM to 3 mM concentration range. The limit of detection is 7.9 μM, and the lowest concentration that can be visually detected is 200 μM.
Figure
Pt-NPs were synthesized using BSA-directed one-pot reduction and BSA/Pt-NPs composite can effectively catalyze the oxidation of TMB producing blue solution in the presence of H2O2.  相似文献   

7.
We have studied the CdTe quantum dot-induced phototransformation of 2,4-dichlorophenol (2,4-DCP) and its subsequent chemiluminescence (CL) reaction. Quantum dots (QDs) of different size and capped with thioglycolic acid were prepared and characterized by molecular spectroscopy, X-ray diffraction and transmission electron microscopy. In the presence of QDs, 2,4-DCP is photochemically transformed into a long-living light emitting precursor which can react with N-bromosuccinimide to produce CL with peak wavelengths at 475 and 550 nm. The formation of singlet oxygen during the phototransformation process was confirmed by the enhancement effect of deuterium oxide on the CL reaction and the change in the UV spectrum of a chemical trap. The CL intensity is linearly related to the concentration of 2,4-DCP in the range from 0.36 to 36 μmol L?1, and the detection limit (at 3σ) is 0.13 μmol L?1.
Figure
CdTe QDs as an alternative photosensitizer that can be applied to the phototransformation/CL detection of 2, 4-DCP.  相似文献   

8.
A biocomposite film for sensing hydrogen peroxide (HP) is described that is based on nanospheres made from hemoglobin (Hb), graphene, and zinc oxide. The composition, morphology and size of the film were studied by transmission electron microscopy. UV-vis spectroscopy revealed that the Hb entrapped in the graphene and ZnO nanosphere retains its native structure. A pair of stable and well-defined quasi-reversible redox peaks of Hb was obtained, with a formal potential of ?30 mV at pH 6.5. Hb exhibits excellent long-term bioelectrocatalytic activity towards HP. The apparent heterogeneous electron transfer rate constant is 1.0 s?1, indicating that the presence of graphene in the composite film facilitates the electron transfer between matrix and the electroactive center of Hb. The sensor responds linearly to HP in the range from 1.8 μM to 2.3 mM, with a detection limit of 0.6 μM (at S/N?=?3). The apparent Michaelis-Menten constant is 1.46 mM. The biosensor displays high sensitivity, good reproducibility, and long-term stability.
Figure
TEM images of graphene insert: graphene-ZnO nanosphere  相似文献   

9.
We describe an easy and inexpensive way to provide a highly defined Gaussian shaped laser spot on target of 5 μm diameter for imaging mass spectrometry using a commercial MALDI TOF instrument that is designed to produce a 20 μm diameter laser beam on target at its lowest setting. A 25 μm pinhole filter on a swivel arm was installed in the laser beam optics outside the vacuum ion source chamber so it is easily flipped into or out of the beam as desired by the operator. The resulting ion images at 5 μm spatial resolution are sharp since the satellite secondary laser beam maxima have been removed by the filter. Ion images are shown to demonstrate the performance and are compared with the method of oversampling to achieve higher spatial resolution when only a larger laser beam spot on target is available.
Figure
?  相似文献   

10.
An atmospheric pressure laser desorption/ionization mass spectrometry imaging ion source has been developed that combines high spatial resolution and high mass resolution for the in situ analysis of biological tissue. The system is based on an infrared laser system working at 2.94 to 3.10 μm wavelength, employing a Nd:YAG laser-pumped optical parametrical oscillator. A Raman-shifted Nd:YAG laser system was also tested as an alternative irradiation source. A dedicated optical setup was used to focus the laser beam, coaxially with the ion optical axis and normal to the sample surface, to a spot size of 30 μm in diameter. No additional matrix was needed for laser desorption/ionization. A cooling stage was developed to reduce evaporation of physiological cell water. Ions were formed under atmospheric pressure and transferred by an extended heated capillary into the atmospheric pressure inlet of an orbital trapping mass spectrometer. Various phospholipid compounds were detected, identified, and imaged at a pixel resolution of up to 25 μm from mouse brain tissue sections. Mass accuracies of better than 2 ppm and a mass resolution of 30,000 at m/z?=?400 were achieved for these measurements.
Figure
Infrared laser desorption/ionization mass spectrometry imaging provides for direct analysis of biological tissue with a high spatial resolution of 25 μm  相似文献   

11.
Macroporous reversed-phase (mRP) chromatography was successfully used to develop an accurate and precise method for total protein in serum. The limits of detection (0.83 μg, LOD) and quantification (2.51 μg, LOQ) for the mRP method are comparable with those of the widely used micro BCA protein assay. The mRP method can be used to determine the total protein concentration across a wide dynamic range by detecting chromatographic peaks at 215 nm and 280 nm. The method has the added advantage of desalting and denaturing proteins, leading to more complete digestion by trypsin and to better LC–MS–MS identification in shotgun proteomics experiments.
Figure
Simultaneous Serum Desalting and Total Protein Determination with Macroporous Reversed-Phase Chromatography: calibration plots  相似文献   

12.
13.
We report on a fast, simple and accurate method for the determination of proline in urine samples by employing a nanostructured film of conducting polypyrrole for electrochemically controlled solid-phase microextraction, and ion mobility spectrometry (IMS) for detection. This method has the advantages of simple sample preparation and a sensitivity of IMS to proline that is higher than that for other amino acids. The calibration curve is linear in the range of 0.5–60 μg L?1 (4–521 nmol L?1), and the detection limit is 0.2 μg L?1. The electrochemical potentials for uptake and release were optimized. The method was successfully applied to the clean-up and quantitation of trace amounts of proline in urine samples.
Figure
Proline determination by electrochemically controlled solid phase microextraction coupled to ion mobility spectrometry  相似文献   

14.
We report on the amperometric determination of sulfite using screen-printed carbon electrodes (SPCEs) modified with gold and silver nanoparticles that were deposited on the electrode to improve the capabilities of detection. The electrode is fairly selective and responds to sulfite with an oxidation current (at 300 mV and pH 6) in the 9.80 to 83.33 μM concentration range. The precision in terms of repeatability and reproducibility is 14.4 % and 10.7 % in the case of SPCEs modified by gold nanoparticles. The method was applied to the determination of sulfite in drinking water, pickle juice and vinegar. Recoveries ranged from 96 % to 104 %.
Figure
Amperometric determination of sulfite using a sensor based on the immobilization gold nanoparticles on a disposable screen-printed carbon electrode  相似文献   

15.
The fluorescence quenching of quantum dots by hemoglobin has been demonstrated to depend on surface functionalization, and this property has been utilized to construct a novel fluorescent method for rapid, sensitive, and selective detection of trace hemoglobin in urine at microgram level. This method shows low interference and high selectivity for hemoglobin with a limit of detection of 4.3 μg L?1 in water and 66.1 μg L?1 in urine, which are lower than those of currently used methods in labs and clinics. Spike and recovery tests in raw, acidified, and alkalized urine samples exhibit good recovery rates for the spiked concentrations close to the limit of detection.
Figure
Fluorescence spectra and photographs of MPA-QD solution before and after the addition of Hb taken under 365-nm irradiation.  相似文献   

16.
We report on a small (20?×?10 mm) micromachined device for the detection of gases in micro-gas chromatography (GC). It incorporates a micro-discharge across a 20-μm gap, and a remote electrode in the micro cavity that generates an electrical signal corresponding to the photo-ionization of gaseous analytes in a stream of carrier gas. Multi-component mixtures were detected and the results compared to those obtained with a flame ionization detector. The minimum detectable limit is 350 pg.μL?1 of n-octane in air when applying a 1.4 mW discharge. The combination of wet etching of glass (as used for microfluidic channels) with a lift-off process for detector electrodes by a robust batch process results in a universal, non-destructive, and sensitive microdetector for micro-GC.
Figure
?  相似文献   

17.
We have developed an aptasensor for adenosine triphosphate (ATP) based on an electrode-supported lipid bilayer membrane. The assay is based on a conformational change that is induced after binding the target which modulates the electron transfer rate in the conductive path. The method is highly sensitive, stable, and repeatable. The detection limit for ATP is 50 nM, and the dynamic range extends to 3.2 μM, which covers the concentration range of ATP in cell lysates (from 0.1 to 1 μM). The method also holds promise in that it may be transferred to submicro- or nano-scale electrodes so to enable intracellular monitoring of ATP.
Figure
An aptasensor for adenosine triphosphate based on an electrode-supported lipid bilayer membrane in principle of target-binding induced conformational change to modulate the electron transfer rate in the conductive path.  相似文献   

18.
We report on a sensitive electrochemical sensor for dopamine (DA) based on a glassy carbon electrode that was modified with a nanocomposite containing electrochemically reduced graphene oxide (RGO) and palladium nanoparticles (Pd-NPs). The composite was characterized by scanning electron microscopy, energy dispersive spectroscopy, and electrochemical impendence spectroscopy. The electrode can oxidize DA at lower potential (234 mV vs Ag/AgCl) than electrodes modified with RGO or Pd-NPs only. The response of the sensor to DA is linear in the 1–150 μM concentration range, and the detection limit is 0.233 μM. The sensor was applied to the determination of DA in commercial DA injection solutions.
Figure
Schematic representation showing the oxidation of DA at RGO-Pd-NPs composite electrode.  相似文献   

19.
We describe an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. A 300-μm-diameter platinum disc working electrode was embedded in a titanium tube which provides an adequate holding for working electrode and acts as counter electrode. We also have designed a simplified detection cell with a guide channel for the electrode. The integrated working-counter electrode can be easily aligned to the outlet of the separation channel through the guide channel. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3). The system was further applied to the determination of chlorpromazine hydrochloride in pharmaceutical formulations. The system is believed to have potential applications in pharmaceutical analysis.
Figure
We described an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3).  相似文献   

20.
A thin film of poly(eriochrome black T) was deposited on the surface of glassy carbon electrode by cyclic voltammetry, and this system is shown to enable the sensitive determination of adenine (A) and guanine (G). Scanning electron microscopy, Fourier transform infrared spectroscopy and electrochemical impedance spectroscopy were carried out to characterize the film which exhibits excellent electrocatalytic activity toward the oxidation of A and G in 0.1 M phosphate buffer solution (pH 4.0). Square wave voltammetry reveals an oxidation peak at 1084 mV whose current is linearly related to the concentration of A in the range from 0.05 to 1.00 μM. The oxidation peak for G occurs at 788 mV, and its current is linearly related to the concentration of G in the range from 0.025 to 1.00 μM. The detection limits are 0.017 μM for A and 0.008 μM for G (at S/N?=?3), respectively. The modified electrode displays good reproducibility and selectivity for the determination of A and G. The sensor was applied to quantify A and G in fish sperm DNA with satisfactory results.
Figure
Square wave voltammograms of bare GCE (a), PEBT/GCE (b) in the presence of 1.00 μM adenine (A) and 1.00 μM guanine (G).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号