首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.

In this study, the extraction of lipophilic wood extractives from dissolving pulp samples using ionic liquid–liquid extraction and a two phase hollow fibre supported liquid membrane was investigated. Ionic liquids are capable of dissolving a range of organic and polymeric compounds and are biodegradable, with a negligible vapour pressure. Pulp samples were dissolved in a suitable amount of molten 1-butyl-3-methylimidazolium chloride to give 5 % cellulose solution. Pure cellulose was regenerated by adding water and filtered off. The ionic liquid-aqueous filtrate was first extracted for lipophilic extractives using liquid–liquid extraction. Then, a two phase hollow fibre supported liquid membrane extraction of lipophilic extractives was performed to extract the derivatized compounds prior to analysis by gas chromatography mass spectrometry. The operational parameters of this sample preparation approach were optimised using sterols and fatty acid methyl esters. The variation of enrichment factors and extraction efficiency with respect to liquid membrane, extraction time, stirring speed and sample pH were observed and used to get the optimal parameters. The approach was used in the analysis of oxygen bleached dissolving pulp samples in which main compounds identified were fatty acids, sterols, fatty alcohols, steroid hydrocarbons and ketones. These compounds were similar to those obtained using molecular solvent extraction method, which indicated the absence of chemical reaction between extractives and ionic liquid used.

  相似文献   

2.
Solid-supported liquid–liquid extraction was optimized to extract the chemical warfare agents and their non-toxic analogues from water. The developed method was compared to the conventionally used liquid–liquid extraction. This method yielded high recoveries (70–80%) of non-toxic analogues of chemical warfare agents and good recoveries (65–75%) of the nerve agent sarin and Lewisite-III. The limits of detection of non-toxic analogues of CWAs, and toxic sarin and Lewisite-III, in selected ion monitoring and full scan mode, varied from 0.01 to 0.5 μg mL?1 and 0.1 to 1.0 μg mL?1 respectively.  相似文献   

3.
The less polar phase of liquid–liquid extraction systems has been studied extensively for improving metal separations; however, the role of the more polar phase has been overlooked for far too long. Herein, we investigate the extraction of metals from a variety of polar solvents and demonstrate that, the influence of polar solvents on metal extraction is so significant that extraction of many metals can be largely tuned, and the metal separations can be significantly enhanced by selecting suitable polar solvents. Furthermore, a mechanism on how the polar solvents affect metal extraction is proposed based on comprehensive characterizations. The method of using suitable polar solvents in liquid–liquid extraction paves a new and versatile way to enhance metal separations.  相似文献   

4.
An efficient, simple, and fast method based on ionic liquid dispersive liquid–liquid microextraction (IL-DLLME) followed by magnetic solid-phase extraction (MSPE) was developed as a new technique for extracting and purifying hexachlorophene (HCP) in cosmetics prior to high-performance liquid chromatography (HPLC) determination. In this method based on IL-DLLME and MSPE, 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) is used as the extraction solvent and Fe3O4 nanoparticles are used to remove hydrophobic additives in the cosmetics by physical adsorption. The main parameters affecting the efficiency of the IL-DLLME and MSPE of HCP were investigated and optimized. Under the optimum conditions, the method was linear in the range 0.5–40 µg mL?1 with a correlation coefficient (R 2) of 0.9976 and had a detection limit of 0.14 µg mL?1 at a signal-to-noise ratio (S/N) of 3. The recoveries of HCP in three cosmetic samples using the proposed method were in the range 74.5–97.7%, and the relative standard deviations (RSD, n = 5) were in the range 3.8–6.7%. The developed method was successfully applied to the determination of HCP in cosmetics.  相似文献   

5.
《Analytical letters》2012,45(18):2871-2881
A method for determination of five herbicides (i.e., quinclorac, metsulfuron-methyl, bensulfuron-methyl, atrazine, prometryn) in soil was developed by dispersive solid-phase extraction combined with dispersive liquid–liquid microextraction and high-performance liquid chromatography. The analytes were removed from the soil by liquid partitioning with acetonitrile/5% acetic acid, purified using a octadecylsilane sorbent, and subsequently extracted before chromatographic analysis. Under the optimized conditions, the linear dynamic range was from 10.0 to 300 ng g?1 with correlation coefficients (r) between 0.9971 and 0.9985. The limits of detection were between 1.5 and 3.1 ng g?1, with relative standard deviations from 3.8% to 6.7% (n = 5). The recovery of the herbicides from soil at fortification levels of 20.0 and 100.0 ng g?1 were between 71.5% and 94.3%. The method was successfully applied to the determination of the analytes in soil.  相似文献   

6.
A flow-injection procedure for the determination of iron(III) in water is described. The procedure is based on the formation of an ion pair between the tetraphenylarsonium (Ph4As+) (TPA) or tetrabutylammonium (But4N+) (TBA) cations and the tetrathiocyanatoferrate(III) complex (TTF). This ion pair is extracted with chloroform, and the absorbance of the organic phase is measured at 503nm (for Ph4As+) or 475nm (for But4N+). Iron concentrations higher than 0.9×10–6molL–1 (50µgL–1) can be detected in the first case, with a relative standard deviation of 1.9% (n=12), a linear application rangeof between 1.34 and 54.0×10–6molL–1 (75–3015µgL–1), and a sampling frequency of 30h–1. For the ion pair with But4N+, the detection limit is 0.52×10–6molL–1 (29µgL–1), with a relative standard deviation of 1.6% and a linear application range between 0.73 and 54.0×10–6molL–1. Under the proposed working conditions, only Pd(IV), Cu(II) and Bi(III) interfere. With the application of the merging zones technique, considerable amounts of organic reagent can be saved. The TBA method was applied to the analysis of iron(III) in tap and industrial waste waters.  相似文献   

7.
《Analytical letters》2012,45(11):1787-1801
A rapid and novel two-step dispersive liquid–liquid microextraction and dispersive micro-solid phase extraction method was established for the separation and enrichment of trace cadmium, nickel, and copper in food and environmental water prior to determination by inductively coupled plasma-mass spectrometry (ICP-MS). In the first microextraction step, carbon tetrachloride was employed to extract metal-diethyldithiocarbamate chelates from aqueous solution with ultrasound. In the following step, Fe3O4 magnetic nanoparticles were added and used to collect the analytes in the organic solvent. The sample pH, type and volume of extraction solvent, mass of magnetic nanoparticles, concentration of the chelating agent, concentration of sodium chloride, and sonication time were optimized. The linear dynamic range was from 0.01 to 20 micrograms per liter with correlation coefficients between 0.9990 and 0.9992. Enrichment factors were 78, 79, and 81 for cadmium, nickel, and copper, respectively. The limits of detection for cadmium, nickel, and copper were 0.007, 0.009, and 0.017 micrograms per liter, with relative standard deviations from 1.1 to 2.6 percent. The developed method was validated by the determination of cadmium, nickel, and copper in rice and mussel certified reference materials, food, and environmental water with satisfactory results.  相似文献   

8.
In this study, an effective method of ultrasound-assisted ionic liquid based dispersive liquid–liquid microextraction (UA?IL?DLLME) coupled with HPLC was applied for extraction and determination of two antidepressant drugs: venlafaxine hydrochloride and amitriptyline hydrochloride from human plasma samples. Three ionic liquids were studied: 1-butyl-3-methyl imidazolium hexafluorophosphate, 1-hexyl-3- methyl imidazolium hexa-fluoro-phosphate, and 1-octyl-3-methyl imidazolium hexafluorophosphate [C8MIM][PF6]. Various factors affect the stages and efficiency of extraction, some of which are pH of sample solution, type and volume of ionic liquid, the time of ultrasonication, centrifuging time and rate, and the ionic strength of solution. In this research, optimum conditions were obtained as 55 μL of [C8MIM][PF6] selected as ionic liquid, pH 11, 2% NaCl, 4 min ultrasonication and 5 min centrifuging at 3500 rpm. Under the optimized conditions, the linearity was obtained in the range of 0.2 to 250 μg/L. The limits of detection were 0.5 μg/L for venlafaxine and 0.8 μg/L for amitriptyline. Pre-concentration factors were 1.3 × 103 for venlafaxine and 1.2 × 103 for amitriptyline. The UA?IL?DLLME method coupled with HPLC was successfully used for the determination of venlafaxine and amitriptyline spiked into the real samples of human plasma.  相似文献   

9.
This study describes an accurate, sensitive, and specific chromatographic method for the simultaneous quantitative determination of lamivudine and zidovudine in human blood plasma, using stavudine as an internal standard. The chromatographic separation was performed using a C8 column (150 × 4.6 mm, 5 μm), and ultraviolet absorbency detection at 270 nm with gradient elution. Two mobile phases were used. Phase A contained 10 mM potassium phosphate and 3% acetonitrile, whereas Phase B contained methanol. A linear gradient was used with a variability of A-B phase proportion from 98–2% to 72–28%, respectively. The drug extraction was performed with two 4 mL aliquots of ethyl acetate.  相似文献   

10.
The object of this study was to measure the liquid–liquid equilibria (LLE) data of binary mixtures containing ionic liquids and citrus essential oil. We investigated linalool as the citrus essential oil, and 1-alkyl-3-methyl-imidazolium bis(trifluoromethanesulfonyl)imide ([C n MIM]+[TFSI]?) as the ionic liquid. Firstly, the experimental apparatus and procedure for the LLE measurement of mixtures containing ionic liquids were verified by measuring the LLE of the binary mixture 1-hexyl-3-methyl-imidazolium bis(trifluoromethanesulfonyl)imide ([C6MIM]+[TFSI]?) + 1-hexanol as a reference test system recommended by Marsh et al. (Pure Appl Chem 81:781–789, 2009). Next, the LLE data for IL + linalool were obtained, and the LLE data of two binary mixtures 1-butyl-3-methyl-imidazolium bis(trifluoromethanesulfonyl)imide ([C4MIM]+[TFSI]?) or [C6MIM]+[TFSI]? + linalool were determined. The experimental LLE data were satisfactorily represented by the non-random two-liquid model.  相似文献   

11.
《Analytical letters》2012,45(9):1485-1499
A fast and reliable ultra-high performance liquid chromatography–tandem mass spectrometry method was developed for the determination of aflatoxins B1, B2, G1, and G2 in cereal. The analytes were extracted by accelerated solvent extraction with methanol/water (80:20). A polymeric solid-phase extraction column was used for sample preparation. Under optimum conditions, the analyte recoveries for samples spiked at different concentration levels in rice and maize ranged from 71.2 to 94.0%, with relative standard deviations less than 16.4%. Limits of detection (signal-to-noise ratio, 3:1) for the aflatoxins ranged from 0.25 to 0.93 ng/g. The developed method was applied to the determination of aflatoxins in ten rice and maize samples. One maize sample tested positive with an aflatoxin B1 concentration of 2.7 ng/g.  相似文献   

12.
《Analytical letters》2012,45(8):1245-1256
A comparison between molecularly imprinted solid phase extraction (MISPE) and liquid–liquid extraction (LLE) was performed for cotinine in human urine followed by gas chromatography analysis. The molecularly imprinted polymer (MIP) was synthesized via bulk methodology employing cotinine, methacrylic acid, and ethylene glycol dimethacrylate as template, functional monomer, and cross-linker, respectively. Both methods were validated with good precision and accuracy. The LLE method (limit of quantification = 10 nanograms per milliliter) was slightly more sensitive than the MISPE (limit of quantification = 15 nanograms per milliliter) procedure, but both methods were able to determine cotinine at typical concentrations in urine. An important advantage of the molecularly imprinted polymer approach was its ability to be reused up to at least 100 times. Other advantages of the MISPE include simple manipulation, low solvent consumption, and low worker exposure.  相似文献   

13.
A qualitative method, involving supported liquid–liquid extraction (SLE) and ultra high pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS–MS), was developed for the rapid tentative identification of various drugs of abuse in urine. In this study, 28 drugs and metabolites were covered by the screening procedure. Before analysis, urine samples were extracted by SLE and good extraction recoveries were obtained for most investigated compounds. The UHPLC strategy was then selected for the rapid separation of amphetamines, cocaine, opiates and related compounds in urine. Using columns packed with sub-2 µm particles, analysis time was reduced down to 2 min, while maintaining acceptable performance. Finally, the detection was by tandem MS operating in the single reaction monitoring (SRM) mode. The most intense transition was selected for the different drugs and SRM dwell times set at 5 ms, to maintain sufficient data points across the narrow UHPLC peaks. The tentative identification of the drugs of interest, including amphetamines, opiates and cocaine, was based on both, retention times and mass spectrometry information. With the proposed method, limits of detection were estimated at about 1 ng mL?1 and the applicability was assessed by successfully analyzing several samples of drug abusers. Finally, this study demonstrates the potential of UHPLC coupled to tandem MS for the rapid screening of drugs of abuse in urine.  相似文献   

14.
In this work, surfactant-coated Fe3O4@decanoic acid nanoparticles was synthesized as a viable nanosorbent for coextraction of drugs with different polarities (hydrophobic, hydrophilic). To reach desirable enrichment factors, efficient clean-up and low limits of detection (LODs), the method was combined with dispersive liquid–liquid microextraction (DLLME). The coupling of these extraction methods with GC-FID detection was applied to simultaneous extraction and quantification of venlafaxine (VLF) as a hydrophilic model drug and desipramine (DESI) and clomipramine (CLO) as hydrophobic model drugs in urine samples. The effect of sample pH, nanosorbent amount, sorption time, surfactant concentration, eluent type, eluent volume, salt content, elution time in magnetic solid phase extraction step and extraction solvent and its volume along with sample pH in DLLME step were optimized. Under the selected conditions, linearity was achieved within the range of 5–5000 µg L?1. The LOD values were obtained in the range of 1.5–3.0 µg L?1 for DESI, 1.2–2.5 µg L?1 for VLF and 2.0–4.0 µg L?1 for CLO, respectively. The percent of extraction recoveries and relative standard deviations (n?=?5) were in the range of 82.4–95.9 and 6.1 for DESI, 60.5–92.8 and 6.9 for VLF and 57.2–58.0 and 5.5 for CLO, respectively. Ultimately, the applicability of the new method was successfully confirmed by the extraction and quantification of DESI, VLF and CLO from human urine samples.  相似文献   

15.
Capillary electrophoresis coupled with electrochemiluminescence detection was developed for the separation and determination of dioxopromethazine hydrochloride (DPZ) enantiomers. Performance parameters of the proposed method were evaluated. An improved separation of DPZ enantiomers could be achieved after adding boric acid to buffer. The enantiomers were completely separated with running buffer of 16.5 mM β-CD in 25 mM tris-H3PO4–40 mM H3BO3 at pH 2.5. The proposed method was successfully applied to the separation and determination of DPZ enantiomers in human urine with a liquid–liquid extraction procedure.  相似文献   

16.
The objective of this work was to explore the feasibility of using ionic liquids (ILs), namely N-ethyl-N-methylmorpholinium dicyanamide, [EMMor][DCA], (3-hydroxypropyl)-1-methylmorpholinium dicyanamide, [N-C3OHMMor][DCA], 1-(3-hydroxypropyl)-3-methylimidazolium dicyanamide, [N-C3OHMIM][DCA], 1-(3-hydroxypropyl)pyridinium dicyanamide, [N-C3OHPy][DCA], (3-cyanopropyl)pyridinium dicyanamide, [N-C3CNPy][DCA], and (3-cyanopropyl)methylpyrrolidinium dicyanamide, [N-C3CNMPyr][DCA] for the separation of ethylbenzene and styrene. The liquid–liquid equilibrium (LLE) data in ternary systems of {IL (1)?+?styrene (2)?+?ethylbenzene (3)} at T?=?298.15 K and ambient pressure is presented for the six ILs synthesized by us. The final chromatography analysis of the composition of tie-lines has shown that the studied ILs are not found in the raffinate phase and they show interesting results on the selectivity and solute distribution ratio for styrene extraction. A comparison of different ILs is presented for the studied separation problem. It was observed that the best separation selectivities were found for [N-C3CNPy][DCA] (SAv?=?2.38) and [N-C3OHMMor][DCA] (SAv?=?2.42) in comparison with other studied ILs in this work and those presented in the literature. While the data presented here are useful from a theoretical standpoint, the possibility of applications for these ILs in technological processes is questionable because of low solute distribution ratios, especially those calculated from the masses [N-C3CNPy][DCA] (βMAv?=?0.08) and [N-C3OHMMor][DCA] (βMAv?=?0.07). The experimental tie-lines were correlated with the non-random two liquid NRTL model.  相似文献   

17.
《Analytical letters》2012,45(4):654-674
Jujube extract has a unique flavor that has been used as a common fragrance due to the volatile compounds. In this study, the volatiles of jujube extract were isolated by liquid–liquid extraction, simultaneous distillation extraction, ultrasound-assisted solvent extraction, and headspace solid-phase microextraction, and analyzed by gas chromatography–mass spectrometry. Altogether 92 compounds were identified by the four methods, of which 53 components were identified for the first time; however, only 21 compounds were identified by all these methods. The performance characteristics of the four pretreatment techniques were compared by principal component analysis which showed that the volatile compounds obtained by liquid–liquid extraction and ultrasound-assisted solvent extraction were similar both in categories and in content; whereas, the volatiles extracted by simultaneous distillation extraction, ultrasound-assisted solvent extraction, and headspace solid-phase microextraction greatly varied. The results indicated that a multi-pretreatment technique should be adopted in order to obtain the most complete information about the volatile compounds in jujube extract. The ultrasound-assisted solvent extraction method exhibited excellent repeatability and recoveries, and was very suitable for quantitative analysis. Although the recoveries and reproducibility of headspace solid-phase microextraction were inferior to the other methods, it was more sensitive than other methods.  相似文献   

18.
Summary A sensitive and selective liquid chromatographic method coupled with electrospray ionization tandem mass spectrometry (LC–ESI–MS–MS) has been developed for quantification of felodipine in human and dog plasma. Compounds were separated on a 2.0 mm × 150 mm, 5.0 m particle, C8 column with 1 m m ammonium acetate–acetonitrile, 20:80, pH 6.0, as mobile phase at a flow rate of 200 L min–1. Nifedipine was used as internal standard. Plasma samples were extracted with diethyl ether, the centrifuged upper layer was evaporated, the residue was reconstituted with mobile phase, and the reconstituted samples were injected. The analytical column lasted for at least 1000 injections. By use of multiple reaction monitoring (MRM) mode in MS–MS felodipine and nifedipine were detected without severe interference from the human or dog plasma matrix. Felodipine produced a protonated precursor ion ([M + H]+) at m/z 384 and a corresponding product ion at m/z 338. And internal standard (nifedipine) produced a protonated precursor ion ([M + H]+) at m/z 347 and a corresponding product ion at m/z 315. Detection of felodipine in human and dog plasma was accurate and precise, with a limit of quantification of 0.05 ng mL–1. The method has been successfully applied to preliminary pharmacokinetic study of felodipine in human and dog plasma.  相似文献   

19.
20.
LeiLI  FengLIU 《中国化学快报》2002,13(4):349-350
Extraction behavior of chlorpromazine hydrochloride (CPZ) and procaine hydrochloride (PCN) in the system described in the title was studied. Research shows that the extraction efficiency of CPZ can amount to 96% by twice extraction, while that of PCN is 77%. This system produces the distribution coefficients (KD) of 12.3 and 2.6 respectively for CPZ and PCN. Extraction mechanism is deduced according to ultraviolet and molecular fluorescence spectra variation of the drugs in the system studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号